{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:16:12Z","timestamp":1792084572953,"version":"4.4.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,8]],"date-time":"2022-07-08T00:00:00Z","timestamp":1657238400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,8]],"date-time":"2022-07-08T00:00:00Z","timestamp":1657238400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Volume expansion and vasopressors for the treatment of shock is an intensive process that requires frequent assessments and adjustments. Strict blood pressure goals in multiple physiologic states of shock (traumatic brain injury, sepsis, and hemorrhagic) have been associated with improved outcomes. The availability of continuous physiologic data is amenable to closed-loop automated critical care to improve goal-directed resuscitation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Five adult swine were anesthetized and subjected to a controlled 30% estimated total blood volume hemorrhage followed by 30\u00a0min of complete supra-celiac aortic occlusion and then autotransfusion back to euvolemia with removal of aortic balloon. The animals underwent closed-loop critical care for 255\u00a0min after removal of the endovascular aortic balloon. The closed-loop critical care algorithm used proximal aortic pressure and central venous pressure as physiologic input data. The algorithm had the option to provide programmatic control of pumps for titration of vasopressors and weight-based crystalloid boluses (5\u00a0ml\/kg) to maintain a mean arterial pressure between 60 and 70\u00a0mmHg.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>During the 255\u00a0min of critical care the animals experienced hypotension (&lt;\u200960\u00a0mmHg) 15.3% (interquartile range:\u00a08.6\u201316.9%), hypertension (&gt;\u200970\u00a0mmHg) 7.7% (interquartile range:\u00a06.7\u20139.4%), and normotension (60\u201370\u00a0mmHg) 76.9% (interquartile range:\u00a076.5\u201381.2%) of the time. Excluding the first 60\u00a0min of the critical care phase the animals experienced hypotension 1.0% (interquartile range:\u00a00.5\u20136.7%) of the time. Median intervention rate was 8.47 interventions per hour (interquartile range: 7.8\u20139.2 interventions per hour). The proportion of interventions was 61.5% (interquartile range: 61.1\u201366.7%) weight-based crystalloid boluses and 38.5% (interquartile range: 33.3\u201338.9%) titration of vasopressors.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This autonomous critical care platform uses critical care adjuncts in an ischemia\u2013reperfusion injury model, utilizing goal-directed closed-loop critical care algorithm and device actuation. This description highlights the potential for this approach to deliver nuanced critical care in the ICU environment, thereby optimizing resuscitative efforts and expanding capabilities through cognitive offloading. Future efforts will focus on optimizing this platform through comparative studies of inputs, therapies, and comparison to manual critical care.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40635-022-00459-2","type":"journal-article","created":{"date-parts":[[2022,7,7]],"date-time":"2022-07-07T23:03:32Z","timestamp":1657235012000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Closed-loop automated critical care as proof-of-concept study for resuscitation in a swine model of ischemia\u2013reperfusion injury"],"prefix":"10.1186","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5230-0767","authenticated-orcid":false,"given":"Nathan T. P.","family":"Patel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eduardo J.","family":"Goenaga-Diaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magan R.","family":"Lane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Austin Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucas P.","family":"Neff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy K.","family":"Williams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,8]]},"reference":[{"issue":"8","key":"459_CR1","doi-asserted-by":"publisher","first-page":"972.e9","DOI":"10.1016\/j.amjmed.2018.03.015","volume":"131","author":"R Butler","year":"2018","unstructured":"Butler R, Monsalve M, Thomas GW, Herman T, Segre AM, Polgreen PM, Suneja M (2018) Estimating time physicians and other health care workers spend with patients in an intensive care unit using a sensor network. Am J Med 131(8):972.e9-972.e15","journal-title":"Am J Med"},{"issue":"16","key":"459_CR2","doi-asserted-by":"publisher","first-page":"1987","DOI":"10.1001\/jama.288.16.1987","volume":"288","author":"LH Aiken","year":"2000","unstructured":"Aiken LH, Clarke SP, Sloane DM, Sochalski J, Silber JH (2000) Hospital nurse staffing and patient mortality, nurse burnout, and job dissatisfaction. JAMA 288(16):1987\u20131993","journal-title":"JAMA"},{"issue":"1","key":"459_CR3","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1001\/jamapediatrics.2018.3619","volume":"173","author":"HL Tubbs-Cooley","year":"2019","unstructured":"Tubbs-Cooley HL, Mara CA, Carle AC, Mark BA, Pickler RH (2019) Association of nurse workload with missed nursing care in the neonatal intensive care unit. JAMA Pediatr 173(1):44\u201351","journal-title":"JAMA Pediatr"},{"issue":"7","key":"459_CR4","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1542\/hpeds.2020-003509","volume":"11","author":"IR Rasooly","year":"2021","unstructured":"Rasooly IR, Kern-Goldberger AS, Xiao R, Ponnala S, Ruppel H, Luo B, Craig S, Khan A, McLoone M, Ferro D, Muthu N, Won J, Bonafide CP (2021) Physiologic monitor alarm burden and nurses\u2019 subjective workload in a Children\u2019s Hospital. Hosp Pediatr 11(7):703\u2013710","journal-title":"Hosp Pediatr"},{"key":"459_CR5","doi-asserted-by":"crossref","unstructured":"ATLS Subcommittee; American College of Surgeons\u2019 Committee on Trauma; International ATLS working group. Advanced trauma life support Advanced trauma life support (ATLS\u00ae): the ninth edition. J Trauma Acute Care Surg. 2013;74(5):1363\u20136.","DOI":"10.1097\/TA.0b013e31828b82f5"},{"issue":"2","key":"459_CR6","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1089\/neu.2006.0032","volume":"24","author":"I Butcher","year":"2007","unstructured":"Butcher I, Maas AI, Lu J, Marmarou A, Murray GD, Mushkudiani NA, McHugh GS, Steyerberg EW (2007) Prognostic value of admission blood pressure in traumatic brain injury: results from the IMPACT study. J Neurotrauma 24(2):294\u2013302","journal-title":"J Neurotrauma"},{"key":"459_CR7","unstructured":"Brain Trauma Foundation. Guidelines for the Management of Severe Traumatic Brain Injury. 4th edition. (2016). Available from: https:\/\/braintrauma.org\/uploads\/03\/12\/Guidelines_for_Management_of_Severe_TBI_4th_Edition.pdf. Accessed 14 Aug 21."},{"issue":"3","key":"459_CR8","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1097\/CCM.0000000000002255","volume":"45","author":"A Rhodes","year":"2017","unstructured":"Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, Kumar A, Sevransky JE, Sprung CL, Nunnally ME, Rochwerg B, Rubenfeld GD, Angus DC, Annane D, Beale RJ, Bellinghan GJ, Bernard GR, Chiche JD, Coopersmith C, De Backer DP, French CJ, Fujishima S, Gerlach H, Hidalgo JL, Hollenberg SM, Jones AE, Karnad DR, Kleinpell RM, Koh Y, Lisboa TC, Machado FR, Marini JJ, Marshall JC, Mazuski JE, McIntyre LA, McLean AS, Mehta S, Moreno RP, Myburgh J, Navalesi P, Nishida O, Osborn TM, Perner A, Plunkett CM, Ranieri M, Schorr CA, Seckel MA, Seymour CW, Shieh L, Shukri KA, Simpson SQ, Singer M, Thompson BT, Townsend SR, Van der Poll T, Vincent JL, Wiersinga WJ, Zimmerman JL, Dellinger RP (2017) Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. Crit Care Med 45(3):486\u2013552","journal-title":"Crit Care Med"},{"issue":"1","key":"459_CR9","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.accpm.2018.11.009","volume":"38","author":"J Rinehart","year":"2019","unstructured":"Rinehart J, Ma M, Calderon MD, Bardaji A, Hafiane R, Van der Linden P, Joosten A (2019) Blood pressure variability in surgical and intensive care patients: Is there a potential for closed-loop vasopressor administration? Anaesth Crit Care Pain Med 38(1):69\u201371","journal-title":"Anaesth Crit Care Pain Med"},{"issue":"1","key":"459_CR10","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0167840","volume":"12","author":"F Lamontagne","year":"2017","unstructured":"Lamontagne F, Cook DJ, Meade MO, Seely A, Day AG, Charbonney E, Serri K, Skrobik Y, Hebert P, St-Arnaud C, Quiroz-Martinez H, Mayette M, Heyland DK (2017) Vasopressor use for severe hypotension\u2014a multicentre prospective observational study. PLoS ONE 12(1):e0167840","journal-title":"PLoS ONE"},{"issue":"17","key":"459_CR11","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1056\/NEJMoa1312173","volume":"370","author":"P Asfar","year":"2014","unstructured":"Asfar P, Meziani F, Hamel JF, Grelon F, Megarbane B, Anguel N, Mira JP, Dequin PF, Gergaud S, Weiss N, Legay F, Le Tulzo Y, Conrad M, Robert R, Gonzalez F, Guitton C, Tamion F, Tonnelier JM, Guezennec P, Van Der Linden T, Vieillard-Baron A, Mariotte E, Pradel G, Lesieur O, Ricard JD, Herv\u00e9 F, du Cheyron D, Guerin C, Mercat A, Teboul JL, Radermacher P, SEPSISPAM Investigators (2014) High versus low blood-pressure target in patients with septic shock. N Engl J Med 370(17):1583\u20131593","journal-title":"N Engl J Med"},{"issue":"7","key":"459_CR12","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1007\/s12630-017-0877-1","volume":"64","author":"M Hylands","year":"2017","unstructured":"Hylands M, Moller MH, Asfar P, Toma A, Frenette AJ, Beaudoin N, Belley-C\u00f4t\u00e9 \u00c9, D\u2019Aragon F, Laake JH, Siemieniuk RA, Charbonney E, Lauzier F, Kwong J, Rochwerg B, Vandvik PO, Guyatt G, Lamontagne F (2017) A systematic review of vasopressor blood pressure targets in critically ill adults with hypotension. Can J Anaesth 64(7):703\u2013715","journal-title":"Can J Anaesth"},{"issue":"22","key":"459_CR13","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1016\/j.jor.2020.10.012","volume":"16","author":"M Livesey","year":"2020","unstructured":"Livesey M, Jauregui JJ, Hamaker MC, Pensy RA, Langhammer CG, Eglseder WA (2020) Management of vasopressor induced ischemia. J Orthop 16(22):497\u2013502","journal-title":"J Orthop"},{"issue":"1","key":"459_CR14","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1213\/ANE.0b013e318230e9e0","volume":"114","author":"J Rinehart","year":"2012","unstructured":"Rinehart J, Liu N, Alexander B, Cannesson M (2012) Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization? Anesth Analg 114(1):130\u2013143","journal-title":"Anesth Analg"},{"key":"459_CR15","first-page":"1949","volume":"2014","author":"R Bighamian","year":"2014","unstructured":"Bighamian R, Rubbo C, Thorsen JE, Hahn J-O, Reisner AT (2014) Is there opportunity for automated decision-support and closed-loop control in ICU patients receiving vasopressor infusion? Annu Int Conf IEEE Eng Med Biol Soc. 2014:1949\u20131952","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc."},{"issue":"3","key":"459_CR16","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1097\/ALN.0000000000002581","volume":"130","author":"A Joosten","year":"2019","unstructured":"Joosten A, Delaporte A, Alexander B, Su F, Creteur J, Vincent JL, Cannesson M, Rinehart J (2019) Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model. Anesthesiology 130(3):394\u2013403","journal-title":"Anesthesiology"},{"issue":"5 Suppl","key":"459_CR17","first-page":"S183","volume":"54","author":"NF Chaisson","year":"2003","unstructured":"Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC (2003) Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma 54(5 Suppl):S183\u2013S192","journal-title":"J Trauma"},{"issue":"1","key":"459_CR18","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1186\/s13613-018-0436-0","volume":"8","author":"N Libert","year":"2018","unstructured":"Libert N, Chenegros G, Harrois A, Baudry N, Cordurie G, Benosman R, Vicaut E, Duranteau J (2018) Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study. Ann Intensive Care 8(1):89","journal-title":"Ann Intensive Care"},{"issue":"9","key":"459_CR19","doi-asserted-by":"publisher","first-page":"2031","DOI":"10.1097\/CCM.0b013e31821cb790","volume":"39","author":"J Salinas","year":"2011","unstructured":"Salinas J, Chung KK, Mann EA, Cancio LC, Kramer GC, Serio-Melvin ML, Renz EM, Wade CE, Wolf SE (2011) Computerized decision support system improves fluid resuscitation following severe burns: an original study. Crit Care Med 39(9):2031\u20132038","journal-title":"Crit Care Med"},{"issue":"1","key":"459_CR20","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.bja.2020.08.051","volume":"126","author":"A Joosten","year":"2021","unstructured":"Joosten A, Chirnoaga D, Van der Linden P, Barvais L, Alexander B, Duranteau J, Vincent JL, Cannesson M, Rinehart J (2021) Automated closed-loop versus manually controlled norepinephrine infusion in patients undergoing intermediate- to high-risk abdominal surgery: a randomised controlled trial. Br J Anaesth 126(1):210\u2013218","journal-title":"Br J Anaesth"},{"issue":"1","key":"459_CR21","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s40635-018-0168-3","volume":"6","author":"W Klingert","year":"2018","unstructured":"Klingert W, Peter J, Thiel C, Thiel K, Rosenstiel W, Klingert K, Grasshoff C, K\u00f6nigsrainer A, Schenk M (2018) Fully automated life support: an implementation and feasibility pilot study in healthy pigs. Intensive Care Med Exp 6(1):2","journal-title":"Intensive Care Med Exp"},{"issue":"1","key":"459_CR22","first-page":"3","volume":"3","author":"TK Williams","year":"2019","unstructured":"Williams TK, Neff LP, Tibbits EM, Hoareau GL, Simon MA, Davidson AJ, Desoucy ES, Faulconer ER, Johnson MA (2019) A novel automated endovascular variable aortic control device to expand function of standard reboa catheters. J Endovasc Resuscit Trauma Manage 3(1):3\u201310","journal-title":"J Endovasc Resuscit Trauma Manage"},{"issue":"5","key":"459_CR23","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1097\/SHK.0000000000001199","volume":"51","author":"MA Johnson","year":"2019","unstructured":"Johnson MA, Tibbits EM, Hoareau GL, Simon MA, Davidson AJ, DeSoucy ES, Faulconer ER, Grayson JK, Neff LP, Williams TK (2019) Endovascular perfusion augmentation for critical care: partial aortic occlusion for treatment of severe ischemia-reperfusion shock. Shock 51(5):659\u2013666","journal-title":"Shock"},{"issue":"1","key":"459_CR24","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s13613-016-0216-7","volume":"6","author":"X Monnet","year":"2016","unstructured":"Monnet X, Marik PE, Teboul JL (2016) Prediction of fluid responsiveness: an update. Ann Intensive Care 6(1):111. https:\/\/doi.org\/10.1186\/s13613-016-0216-7","journal-title":"Ann Intensive Care"},{"issue":"9","key":"459_CR25","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1007\/s00134-015-3850-x","volume":"41","author":"M Cecconi","year":"2015","unstructured":"Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant JY, De Backer D, FENICE Investigators; ESICM Trial Group (2015) Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med 41(9):1529\u20131537","journal-title":"Intensive Care Med"},{"issue":"3","key":"459_CR26","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1097\/MCC.0000000000000937","volume":"28","author":"VK Arya","year":"2022","unstructured":"Arya VK, Al-Moustadi W, Dutta V (2022) Cardiac output monitoring\u2014invasive and noninvasive. Curr Opin Crit Care 28(3):340\u2013347","journal-title":"Curr Opin Crit Care"},{"issue":"1","key":"459_CR27","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1053\/j.jvca.2017.03.019","volume":"32","author":"E Butler","year":"2018","unstructured":"Butler E, Nguyen J, Mahendran S, Aneman A (2018) Fluid responsiveness after cardiac surgery (FRACAS): a prospective observational study using peripheral near-infrared spectroscopy. J Cardiothorac Vasc Anesth 32(1):197\u2013204","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"6","key":"459_CR28","doi-asserted-by":"publisher","first-page":"1916","DOI":"10.1213\/ANE.0000000000002329","volume":"126","author":"B Parvinian","year":"2018","unstructured":"Parvinian B, Scully C, Wiyor H, Kumar A, Weininger S (2018) Regulatory considerations for physiological closed-loop controlled medical devices used for automated critical care: food and drug administration workshop discussion topics. Anesth Analg 126(6):1916\u20131925","journal-title":"Anesth Analg"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-022-00459-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-022-00459-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-022-00459-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,7]],"date-time":"2022-07-07T23:06:49Z","timestamp":1657235209000},"score":1,"resource":{"primary":{"URL":"https:\/\/icm-experimental.springeropen.com\/articles\/10.1186\/s40635-022-00459-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,8]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["459"],"URL":"https:\/\/doi.org\/10.1186\/s40635-022-00459-2","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,8]]},"assertion":[{"value":"18 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Animal studies were approved through the Institutional Animal Care and Use Committee at Wake Forest Baptist Medical Center (A21-092).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"L.P.N., T.K.W., M.A.J. are co-founders of Certus Critical Care, Incorporated. N.T.P.P. is a paid consultant for Certus Critical Care.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"30"}}