{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T04:48:27Z","timestamp":1793249307877,"version":"4.5.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Innovation Award Amsterdam UMC","award":["2022-06"],"award-info":[{"award-number":["2022-06"]}]},{"name":"Cornelia Foundation","award":["CS 20210068"],"award-info":[{"award-number":["CS 20210068"]}]},{"name":"Emma Children's Hospital and Vermas Foundation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Obtaining a properly fitting non-invasive ventilation (NIV) mask to treat acute respiratory failure is a major challenge, especially in young children and patients with craniofacial abnormalities. Personalization of NIV masks holds promise to improve pediatric NIV efficiency. As current customization methods are relatively time consuming, this study aimed to test the air leak and surface pressure performance of personalized oronasal face masks using 3D printed soft materials. Personalized masks of three different biocompatible materials (silicone and photopolymer resin) were developed and tested on three head models of young children with abnormal facial features during preclinical bench simulation of pediatric NIV. Air leak percentages and facial surface pressures were measured and compared for each mask.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Personalized NIV masks could be successfully produced in under 12 h in a semi-automated 3D production process. During NIV simulation, overall air leak performance and applied surface pressures were acceptable, with leak percentages under 30% and average surface pressure values mostly remaining under normal capillary pressure. There was a small advantage of the masks produced with soft photopolymer resin material.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This first, proof-of-concept bench study simulating NIV in children with abnormal facial features, showed that it is possible to obtain biocompatible, personalized oronasal masks with acceptable air leak and facial surface pressure performance using a relatively short, and semi-automated production process. Further research into the clinical value and possibilities for application of personalized NIV masks in critically ill children is needed.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40635-024-00607-w","type":"journal-article","created":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T02:02:10Z","timestamp":1709258530000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Development of personalized non-invasive ventilation masks for critically ill children: a bench study"],"prefix":"10.1186","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3939-4169","authenticated-orcid":false,"given":"Rosemijne R. W. P.","family":"Pigmans","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rozalinde","family":"Klein-Blommert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica C.","family":"van Gestel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dick G.","family":"Markhorst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Hammond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pim","family":"Boomsma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Daams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia M. A.","family":"de Jong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul M.","family":"Heeman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Job B. M.","family":"van Woensel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Coen D.","family":"Dijkman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinout A.","family":"Bem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,1]]},"reference":[{"issue":"12","key":"607_CR1","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1007\/s00134-017-4920-z","volume":"43","author":"MCJ Kneyber","year":"2017","unstructured":"Kneyber MCJ, de Luca D, Calderini E, Jarreau PH, Javouhey E, Lopez-Herce J, Hammer J, Macrae D, Markhorst DG, Medina A, Pons-Odena M, Racca F, Wolf G, Biban P, Brierley J, Rimensberger PC, section Respiratory Failure of the European Society for Paediatric Neonatal Intensive Care (2017) Recommendations for mechanical ventilation of critically ill children from the Paediatric Mechanical Ventilation Consensus Conference (PEMVECC). Intensive Care Med 43(12):1764\u20131780. https:\/\/doi.org\/10.1007\/s00134-017-4920-z","journal-title":"Intensive Care Med"},{"key":"607_CR2","doi-asserted-by":"publisher","DOI":"10.23937\/2378-3516\/1410077","author":"N Barker","year":"2018","unstructured":"Barker N, Willox M, Elphick H (2018) A review of the benefits, challenges and the future for interfaces for long term non-invasive ventilation in children. Int J Respir Pulm Med. https:\/\/doi.org\/10.23937\/2378-3516\/1410077","journal-title":"Int J Respir Pulm Med"},{"issue":"9","key":"607_CR3","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1097\/PCC.0000000000003281","volume":"24","author":"G Emeriaud","year":"2023","unstructured":"Emeriaud G, Pons-Odena M, Bhalla AK, Shein SL, Killien EY, Modesto IAV, Rowan C, Baudin F, Lin JC, Gregoire G, Napolitano N, Mayordomo-Colunga J, Diaz F, Cruces P, Medina A, Smith L, Khemani RG, Pediatric Acute Respiratory Distress Syndrome Incidence Epidemiology Investigators Pediatric Acute Lung Injury Sepsis Investigators Network (2023) Noninvasive ventilation for pediatric acute respiratory distress syndrome: experience from the 2016\/2017 pediatric acute respiratory distress syndrome incidence and epidemiology prospective cohort study. Pediatr Crit Care Med 24(9):715\u2013726. https:\/\/doi.org\/10.1097\/PCC.0000000000003281","journal-title":"Pediatr Crit Care Med"},{"key":"607_CR4","doi-asserted-by":"publisher","DOI":"10.1183\/23120541.00168-2017","author":"AK Brill","year":"2018","unstructured":"Brill AK, Pickersgill R, Moghal M, Morrell MJ, Simonds AK (2018) Mask pressure effects on the nasal bridge during short-term noninvasive ventilation. ERJ Open Res. https:\/\/doi.org\/10.1183\/23120541.00168-2017","journal-title":"ERJ Open Res"},{"issue":"3","key":"607_CR5","doi-asserted-by":"publisher","first-page":"0310031","DOI":"10.1115\/1.4040187","volume":"12","author":"YY Wu","year":"2018","unstructured":"Wu YY, Acharya D, Xu C, Cheng B, Rana S, Shimada K (2018) Custom-fit three-dimensional-printed BiPAP mask to improve compliance in patients requiring long-term noninvasive ventilatory support. J Med Device 12(3):0310031\u20130310038. https:\/\/doi.org\/10.1115\/1.4040187","journal-title":"J Med Device"},{"key":"607_CR6","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2022.873426","author":"R Hovenier","year":"2022","unstructured":"Hovenier R, Goto L, Huysmans T, van Gestel M, Klein-Blommert R, Markhorst D, Dijkman C, Bem RA (2022) Reduced air leakage during non-invasive ventilation using a simple anesthetic mask with 3D-printed adaptor in an anthropometric based pediatric head-lung model. Front Pediatr. https:\/\/doi.org\/10.3389\/fped.2022.873426","journal-title":"Front Pediatr"},{"issue":"6","key":"607_CR7","doi-asserted-by":"publisher","first-page":"699","DOI":"10.4187\/respcare.05244","volume":"62","author":"KL Fedor","year":"2017","unstructured":"Fedor KL (2017) Noninvasive respiratory support in infants and children. Respir Care 62(6):699\u2013717. https:\/\/doi.org\/10.4187\/respcare.05244","journal-title":"Respir Care"},{"issue":"11","key":"607_CR8","doi-asserted-by":"publisher","first-page":"1536","DOI":"10.4187\/respcare.04036","volume":"60","author":"MO Visscher","year":"2015","unstructured":"Visscher MO, White CC, Jones JM, Cahill T, Jones DC, Pan BS (2015) Face masks for noninvasive ventilation: fit, excess skin hydration, and pressure ulcers. Respir Care 60(11):1536\u20131547. https:\/\/doi.org\/10.4187\/respcare.04036","journal-title":"Respir Care"},{"key":"607_CR9","doi-asserted-by":"publisher","DOI":"10.3390\/jpm12040604","author":"M Bockstedte","year":"2022","unstructured":"Bockstedte M, Xepapadeas AB, Spintzyk S, Poets CF, Koos B, Aretxabaleta M (2022) Development of personalized non-invasive ventilation interfaces for neonatal and pediatric application using additive manufacturing. J Pers Med. https:\/\/doi.org\/10.3390\/jpm12040604","journal-title":"J Pers Med"},{"issue":"1","key":"607_CR10","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1183\/09031936.03.00115903","volume":"23","author":"MW Elliott","year":"2004","unstructured":"Elliott MW (2004) The interface: crucial for successful noninvasive ventilation. Eur Respir J 23(1):7\u20138. https:\/\/doi.org\/10.1183\/09031936.03.00115903","journal-title":"Eur Respir J"},{"issue":"2","key":"607_CR11","doi-asserted-by":"publisher","first-page":"153","DOI":"10.4187\/respcare.01049","volume":"56","author":"DR Hess","year":"2011","unstructured":"Hess DR (2011) Patient\u2013ventilator interaction during noninvasive ventilation. Respir Care 56(2):153\u2013165. https:\/\/doi.org\/10.4187\/respcare.01049","journal-title":"Respir Care"},{"key":"607_CR12","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.26689","author":"PK Bedi","year":"2023","unstructured":"Bedi PK, DeHaan K, Ofosu D, Olmstead D, MacLean JE, Castro-Codesal M (2023) Predictors of NIV-related adverse events in children using long-term noninvasive ventilation. Pediatr Pulmonol. https:\/\/doi.org\/10.1002\/ppul.26689","journal-title":"Pediatr Pulmonol"},{"issue":"2","key":"607_CR13","doi-asserted-by":"publisher","first-page":"241","DOI":"10.4187\/respcare.02616","volume":"59","author":"J Oto","year":"2014","unstructured":"Oto J, Chenelle CT, Marchese AD, Kacmarek RM (2014) A comparison of leak compensation during pediatric noninvasive ventilation: a lung model study. Respir Care 59(2):241\u2013251. https:\/\/doi.org\/10.4187\/respcare.02616","journal-title":"Respir Care"},{"issue":"6","key":"607_CR14","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1097\/CCM.0000000000002369","volume":"45","author":"JV Morris","year":"2017","unstructured":"Morris JV, Ramnarayan P, Parslow RC, Fleming SJ (2017) Outcomes for children receiving noninvasive ventilation as the first-line mode of mechanical ventilation at intensive care admission: a propensity score-matched cohort study. Crit Care Med 45(6):1045\u20131053. https:\/\/doi.org\/10.1097\/CCM.0000000000002369","journal-title":"Crit Care Med"},{"key":"607_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.stlm.2021.100027","author":"SA Goutman","year":"2021","unstructured":"Goutman SA, Chen L, Plott JS, Vankoevering KK, Kurili A, Shih AJ, Green GE (2021) A personalized approach to non-invasive ventilation masks in amyotrophic lateral sclerosis using facial scanning and 3D-printing. Ann 3D Printed Med. https:\/\/doi.org\/10.1016\/j.stlm.2021.100027","journal-title":"Ann 3D Printed Med"},{"issue":"8","key":"607_CR16","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.4187\/respcare.05691","volume":"63","author":"M Shikama","year":"2018","unstructured":"Shikama M, Nakagami G, Noguchi H, Mori T, Sanada H (2018) Development of personalized fitting device with 3-dimensional solution for prevention of NIV oronasal mask-related pressure ulcers. Respir Care 63(8):1024\u20131032. https:\/\/doi.org\/10.4187\/respcare.05691","journal-title":"Respir Care"},{"issue":"2","key":"607_CR17","doi-asserted-by":"publisher","first-page":"516","DOI":"10.18063\/ijb.v8i2.516","volume":"8","author":"C Borras-Novell","year":"2022","unstructured":"Borras-Novell C, Causapie MG, Murcia M, Djian D, Garcia-Algar O (2022) Development of a 3D individualized mask for neonatal non-invasive ventilation. Int J Bioprint 8(2):516. https:\/\/doi.org\/10.18063\/ijb.v8i2.516","journal-title":"Int J Bioprint"},{"issue":"5","key":"607_CR18","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1080\/03091902.2020.1769759","volume":"44","author":"M Willox","year":"2020","unstructured":"Willox M, Metherall P, Jeays-Ward K, McCarthy AD, Barker N, Reed H, Elphick HE (2020) Custom-made 3D printed masks for children using non-invasive ventilation: a feasibility study of production method and testing of outcomes in adult volunteers. J Med Eng Technol 44(5):213\u2013223. https:\/\/doi.org\/10.1080\/03091902.2020.1769759","journal-title":"J Med Eng Technol"},{"key":"607_CR19","unstructured":"DINED anthropometric database (2023) TU Delft, Delft https:\/\/dined.io.tudelft.nl\/en\/ellipse\/tool Accessed 25 Sep 2023"},{"key":"607_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ergon.2019.102828","author":"L Goto","year":"2019","unstructured":"Goto L, Lee W, Molenbroek JFM, Cabo AJ, Goossens RHM (2019) Traditional and 3D scan extracted measurements of the heads and faces of Dutch children. Int J Ind Ergon. https:\/\/doi.org\/10.1016\/j.ergon.2019.102828","journal-title":"Int J Ind Ergon"},{"key":"607_CR21","unstructured":"Young JW (1966) Selected facial measurements of children for oxygen-mask design. AM Rep Apr"},{"key":"607_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2020.103649","author":"EO Bachtiar","year":"2020","unstructured":"Bachtiar EO, Erol O, Millrod M, Tao R, Gracias DH, Romer LH, Kang SH (2020) 3D printing and characterization of a soft and biostable elastomer with high flexibility and strength for biomedical applications. J Mech Behav Biomed Mater. https:\/\/doi.org\/10.1016\/j.jmbbm.2020.103649","journal-title":"J Mech Behav Biomed Mater"},{"key":"607_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.stlm.2021.100044","author":"C Guttridge","year":"2022","unstructured":"Guttridge C, Shannon A, O\u2019Sullivan A, O\u2019Sullivan KJ, O\u2019Sullivan LW (2022) Biocompatible 3D printing resins for medical applications: a review of marketed intended use, biocompatibility certification, and post-processing guidance. Ann 3D Printed Med. https:\/\/doi.org\/10.1016\/j.stlm.2021.100044","journal-title":"Ann 3D Printed Med"},{"key":"607_CR24","doi-asserted-by":"publisher","DOI":"10.1115\/1.4049981","author":"E Martelly","year":"2021","unstructured":"Martelly E, Rana S, Shimada K (2021) Design and fabrication of custom-fit BiPAP and CPAP masks using three-dimensional imaging and three-dimensional printing techniques. J Med Devices. https:\/\/doi.org\/10.1115\/1.4049981","journal-title":"J Med Devices"},{"key":"607_CR25","doi-asserted-by":"publisher","DOI":"10.1115\/1.4050201","author":"Z Ma","year":"2021","unstructured":"Ma Z, Hyde P, Drinnan M, Munguia J (2021) Custom three-dimensional-printed CPAP mask development, preliminary comfort and fit evaluation. J Med Devices. https:\/\/doi.org\/10.1115\/1.4050201","journal-title":"J Med Devices"},{"issue":"8","key":"607_CR26","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1007\/s00134-007-0713-0","volume":"33","author":"L Vignaux","year":"2007","unstructured":"Vignaux L, Tassaux D, Jolliet P (2007) Performance of noninvasive ventilation modes on ICU ventilators during pressure support: a bench model study. Intensive Care Med 33(8):1444\u20131451. https:\/\/doi.org\/10.1007\/s00134-007-0713-0","journal-title":"Intensive Care Med"},{"issue":"3","key":"607_CR27","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1183\/20734735.003414","volume":"10","author":"AK Brill","year":"2014","unstructured":"Brill AK (2014) How to avoid interface problems in acute noninvasive ventilation. Breathe 10(3):230\u2013242. https:\/\/doi.org\/10.1183\/20734735.003414","journal-title":"Breathe"},{"key":"607_CR28","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-031-28963-7_4","volume-title":"Noninvasive mechanical ventilation: theory, equipment, and clinical applications","author":"B Ferraz","year":"2023","unstructured":"Ferraz B, Gomes B, Esquinas AM (2023) Noninvasive ventilation-leaks compensation and clinical implications. In: Esquinas AM (ed) Noninvasive mechanical ventilation: theory, equipment, and clinical applications. Springer International Publishing, Cham. https:\/\/doi.org\/10.1007\/978-3-031-28963-7_4"},{"issue":"2","key":"607_CR29","doi-asserted-by":"publisher","first-page":"244","DOI":"10.4103\/0970-0358.101287","volume":"45","author":"K Agrawal","year":"2012","unstructured":"Agrawal K, Chauhan N (2012) Pressure ulcers: back to the basics. Indian J Plast Surg 45(2):244\u2013254. https:\/\/doi.org\/10.4103\/0970-0358.101287","journal-title":"Indian J Plast Surg"},{"key":"607_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2022.105272","author":"F Savoldi","year":"2022","unstructured":"Savoldi F, Svanetti L, Tsoi JKH, Gu M, Paganelli C, Genna F, Lopomo NF (2022) Experimental determination of the contact pressures produced by a nasal continuous positive airway pressure mask: a case study. J Mech Behav Biomed Mater. https:\/\/doi.org\/10.1016\/j.jmbbm.2022.105272","journal-title":"J Mech Behav Biomed Mater"},{"key":"607_CR31","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.prrv.2016.09.004","volume":"23","author":"G Mortamet","year":"2017","unstructured":"Mortamet G, Amaddeo A, Essouri S, Renolleau S, Emeriaud G, Fauroux B (2017) Interfaces for noninvasive ventilation in the acute setting in children. Paediatr Respir Rev 23:84\u201388. https:\/\/doi.org\/10.1016\/j.prrv.2016.09.004","journal-title":"Paediatr Respir Rev"},{"issue":"1","key":"607_CR32","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1007\/s00134-011-2416-9","volume":"38","author":"C Olivieri","year":"2012","unstructured":"Olivieri C, Costa R, Conti G, Navalesi P (2012) Bench studies evaluating devices for non-invasive ventilation: critical analysis and future perspectives. Intensive Care Med 38(1):160\u2013167. https:\/\/doi.org\/10.1007\/s00134-011-2416-9","journal-title":"Intensive Care Med"},{"issue":"1","key":"607_CR33","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13054-018-1947-7","volume":"22","author":"P Singer","year":"2018","unstructured":"Singer P, Rattanachaiwong S (2018) To eat or to breathe? The answer is both! Nutritional management during noninvasive ventilation. Crit Care 22(1):27. https:\/\/doi.org\/10.1186\/s13054-018-1947-7","journal-title":"Crit Care"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-024-00607-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-024-00607-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-024-00607-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T02:03:25Z","timestamp":1709258605000},"score":1,"resource":{"primary":{"URL":"https:\/\/icm-experimental.springeropen.com\/articles\/10.1186\/s40635-024-00607-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,1]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["607"],"URL":"https:\/\/doi.org\/10.1186\/s40635-024-00607-w","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,1]]},"assertion":[{"value":"17 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The 3D images used for the development of the test head models were obtained with approval of the Joint Research and Ethics Committee of the Eastman Dental Institute\/Eastman Dental Hospital Ethics Committee (JREC 00\/EO42).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21"}}