{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:23:46Z","timestamp":1792801426515,"version":"4.5.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,27]],"date-time":"2024-12-27T00:00:00Z","timestamp":1735257600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,27]],"date-time":"2024-12-27T00:00:00Z","timestamp":1735257600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100015995","name":"Nord universitet","doi-asserted-by":"publisher","award":["03210275"],"award-info":[{"award-number":["03210275"]}],"id":[{"id":"10.13039\/100015995","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100009123","name":"Norges Teknisk-Naturvitenskapelige Universitet","doi-asserted-by":"publisher","award":["70443945"],"award-info":[{"award-number":["70443945"]}],"id":[{"id":"10.13039\/100009123","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Regionale Forskningsfond","award":["324319"],"award-info":[{"award-number":["324319"]}]},{"name":"NTNU Norwegian University of Science and Technology","id":[{"id":"https:\/\/ror.org\/05xg72x27","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Identifying spontaneous circulation during cardiopulmonary resuscitation (CPR) is challenging. Current methods, which involve intermittent and time-consuming pulse checks, necessitate pauses in chest compressions. This issue is problematic in both in-hospital cardiac arrest and out-of-hospital cardiac arrest situations, where resources for identifying circulation during CPR may be limited. The fraction of chest compression plays a pivotal role in improving survival rates. To address this challenge, we evaluated a newly developed hands-free, continuous carotid Doppler system (RescueDoppler), designed to identify spontaneous circulation during chest compressions. In our study, we utilized a porcine model of cardiac arrest to investigate sequences of ventricular fibrillation, followed by defibrillation, and monitoring for the return of spontaneous circulation during chest compressions with the carotid Doppler system. We explored both manual compressions at 100 and 50 compressions per minute and mechanical compressions. To estimate the detection rate (i.e., sensitivity), we employed a logistic mixed model with animal identity as random effect.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Offline analysis of Doppler color M-mode and spectral display successfully identified spontaneous circulation during chest compressions in all compression models. Spontaneous circulation was detected in 51 of 59 sequences, yielding an expected sensitivity of 98% with a 95% confidence interval of 59% to 99%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The RescueDoppler, a continuous hands-free carotid Doppler system, demonstrates an expected sensitivity of 98% for identifying spontaneous circulation during both manual and mechanical chest compressions. Clinical studies are needed to further validate these findings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40635-024-00704-w","type":"journal-article","created":{"date-parts":[[2024,12,27]],"date-time":"2024-12-27T11:51:02Z","timestamp":1735300262000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A hands-free carotid Doppler can identify spontaneous circulation without interrupting cardiopulmonary resuscitation: an animal study"],"prefix":"10.1186","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2582-6696","authenticated-orcid":false,"given":"Bj\u00f8rn Ove","family":"Faldaas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin Stage","family":"Storm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Knut Tore","family":"Lappeg\u00e5rd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ole-Jakob","family":"How","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bent Aksel","family":"Nilsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel","family":"Kiss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eirik","family":"Skogvoll","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik Waage","family":"Nielsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans","family":"Torp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3251-9494","authenticated-orcid":false,"given":"Charlotte Bj\u00f6rk","family":"Ingul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,27]]},"reference":[{"key":"704_CR1","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.resuscitation.2021.02.010","volume":"161","author":"J Soar","year":"2021","unstructured":"Soar J, B\u00f6ttiger BW, Carli P, Couper K, Deakin CD, Dj\u00e4rv T et al (2021) European resuscitation council guidelines 2021: adult advanced life support. Resuscitation 161:115\u2013151","journal-title":"Resuscitation"},{"issue":"1","key":"704_CR2","first-page":"e8","volume":"4","author":"AK Uppiretla","year":"2020","unstructured":"Uppiretla AK, Gangalal GM, Rao S, Bosco DD, Shareef SM, Sampath V (2020) Effects of chest compression fraction on return of spontaneous circulation in patients with cardiac arrest; a brief report. Adv J Emerg Med 4(1):e8","journal-title":"Adv J Emerg Med"},{"key":"704_CR3","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.resuscitation.2020.06.016","volume":"154","author":"C Vaillancourt","year":"2020","unstructured":"Vaillancourt C, Petersen A, Meier EN, Christenson J, Menegazzi JJ, Aufderheide TP et al (2020) The impact of increased chest compression fraction on survival for out-of-hospital cardiac arrest patients with a non-shockable initial rhythm. Resuscitation 154:93\u2013100","journal-title":"Resuscitation"},{"issue":"3","key":"704_CR4","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/S0300-9572(00)00139-8","volume":"44","author":"P Moule","year":"2000","unstructured":"Moule P (2000) Checking the carotid pulse: diagnostic accuracy in students of the healthcare professions. Resuscitation 44(3):195\u2013201","journal-title":"Resuscitation"},{"issue":"2","key":"704_CR5","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/S0300-9572(96)01016-7","volume":"33","author":"B Eberle","year":"1996","unstructured":"Eberle B, Dick WF, Schneider T, Wisser G, Doetsch S, Tzanova I (1996) Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. Resuscitation 33(2):107\u2013116","journal-title":"Resuscitation"},{"issue":"6","key":"704_CR6","doi-asserted-by":"publisher","first-page":"e225","DOI":"10.1016\/j.jemermed.2020.07.005","volume":"59","author":"M Zanatta","year":"2020","unstructured":"Zanatta M, Lorenzi C, Scorpiniti M, Cianci V, Pasini R, Barchitta A (2020) Ultrasound-guided chest compressions in out-of-hospital cardiac arrests. J Emerg Med 59(6):e225\u2013e233","journal-title":"J Emerg Med"},{"issue":"2","key":"704_CR7","doi-asserted-by":"publisher","first-page":"469","DOI":"10.3390\/jcm11020469","volume":"11","author":"M Koch","year":"2022","unstructured":"Koch M, Mueller M, Warenits AM, Holzer M, Spiel A, Schnaubelt S (2022) Carotid artery ultrasound in the (peri-) arrest setting-a prospective pilot study. J Clin Med 11(2):469","journal-title":"J Clin Med"},{"issue":"9","key":"704_CR8","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1016\/j.ajem.2010.05.013","volume":"29","author":"TMMD Larabee","year":"2011","unstructured":"Larabee TMMD, Little CMDO, Raju BIP, Cohen-Solal EP, Erkamp RP, Wuthrich SMSE et al (2011) A novel hands-free carotid ultrasound detects low-flow cardiac output in a swine model of pulseless electrical activity arrest. Am J Emerg Med 29(9):1141\u20131146","journal-title":"Am J Emerg Med"},{"key":"704_CR9","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.resuscitation.2018.10.021","volume":"134","author":"JC Kucewicz","year":"2019","unstructured":"Kucewicz JC, Salcido DD, Adedipe AA, Truong K, Nichol G, Mourad PD (2019) Towards a non-invasive cardiac arrest monitor: an in vivo pilot study. Resuscitation 134:76\u201380","journal-title":"Resuscitation"},{"issue":"5","key":"704_CR10","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1053\/j.jvca.2021.01.040","volume":"35","author":"J-\u00c9S Kenny","year":"2021","unstructured":"Kenny J-\u00c9S (2021) Functional hemodynamic monitoring with a wireless ultrasound patch. J Cardiothoracic Vasc Anesthesia 35(5):1509\u20131515","journal-title":"J Cardiothoracic Vasc Anesthesia"},{"key":"704_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.resplu.2023.100412","volume":"15","author":"BO Faldaas","year":"2023","unstructured":"Faldaas BO, Nielsen EW, Storm BS, Lappeg\u00e5rd KT, How O-J, Nilsen BA et al (2023) Hands-free continuous carotid Doppler ultrasound for detection of the pulse during cardiac arrest in a porcine model. Resuscitation Plus 15:100412","journal-title":"Resuscitation Plus"},{"issue":"5","key":"704_CR12","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/j.annemergmed.2022.12.002","volume":"81","author":"RJ Gaspari","year":"2023","unstructured":"Gaspari RJ, Lindsay R, Dowd A, Gleeson T (2023) Femoral arterial Doppler use during active cardiopulmonary resuscitation. Ann Emerg Med 81(5):523\u2013531","journal-title":"Ann Emerg Med"},{"key":"704_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.resplu.2024.100583","volume":"18","author":"BO Faldaas","year":"2024","unstructured":"Faldaas BO, Nielsen EW, Storm BS, Lappeg\u00e5rd KT, Nilsen BA, Kiss G et al (2024) Real-time feedback on chest compression efficacy by hands-free carotid Doppler in a porcine model. Resuscitation Plus 18:100583","journal-title":"Resuscitation Plus"},{"issue":"2","key":"704_CR14","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1177\/1742271X17753467","volume":"26","author":"B Germanoska","year":"2018","unstructured":"Germanoska B, Coady M, Ng S, Fermanis G, Miller M (2018) The reliability of carotid ultrasound in determining the return of pulsatile flow: a pilot study. Ultrasound 26(2):118\u2013126","journal-title":"Ultrasound"},{"issue":"2","key":"704_CR15","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1007\/s10840-013-9819-1","volume":"38","author":"JC Rubenstein","year":"2013","unstructured":"Rubenstein JC, Gupta MS, Kim MH (2013) Effectiveness of VF induction with DC fibber versus conventional induction methods in patients on chronic amiodarone therapy. J Interv Card Electrophysiol 38(2):137\u2013141","journal-title":"J Interv Card Electrophysiol"},{"issue":"9","key":"704_CR16","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0105213","volume":"9","author":"TA Stenberg","year":"2014","unstructured":"Stenberg TA, Kildal AB, Sanden E, How OJ, Hagve M, Ytrehus K et al (2014) The acute phase of experimental cardiogenic shock is counteracted by microcirculatory and mitochondrial adaptations. PLoS ONE 9(9):e105213","journal-title":"PLoS ONE"},{"issue":"5","key":"704_CR17","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1080\/10903127.2019.1690605","volume":"24","author":"KA Marill","year":"2020","unstructured":"Marill KA, Menegazzi JJ, Koller AC, Sundermann ML, Salcido DD (2020) Synchronized chest compressions for pseudo-PEA: proof of concept and a synching algorithm. Prehosp Emerg Care 24(5):721\u2013729","journal-title":"Prehosp Emerg Care"},{"issue":"5","key":"704_CR18","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0155212","volume":"11","author":"J Xu","year":"2016","unstructured":"Xu J, Li C, Li Y, Walline J, Zheng L, Fu Y et al (2016) Influence of chest compressions on circulation during the peri-cardiac arrest period in porcine models. PLoS ONE 11(5):e0155212","journal-title":"PLoS ONE"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-024-00704-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-024-00704-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-024-00704-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,27]],"date-time":"2024-12-27T12:03:23Z","timestamp":1735301003000},"score":1,"resource":{"primary":{"URL":"https:\/\/icm-experimental.springeropen.com\/articles\/10.1186\/s40635-024-00704-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,27]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["704"],"URL":"https:\/\/doi.org\/10.1186\/s40635-024-00704-w","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,27]]},"assertion":[{"value":"30 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This animal study was approved by the Norwegian Animal Research Authority (FOTS-ID 25415).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Hans Torp is employed by Cimon Medical and Charlotte Bj\u00f6rk Ingul serves as a medical consultant by Cimon Medical, which owns the technology associated with RescueDoppler","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"121"}}