{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,3]],"date-time":"2025-06-03T04:08:59Z","timestamp":1748923739792,"version":"3.41.0"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T00:00:00Z","timestamp":1748822400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T00:00:00Z","timestamp":1748822400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100010100","name":"Sykehuset \u00d8stfold","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100010100","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005366","name":"University of Oslo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005366","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Oxygenator thrombosis is a potentially life-threatening complication during venovenous extracorporeal membrane oxygenation (VV ECMO). It can cause blood flow obstruction, impaired gas exchange, hematologic abnormalities, or sudden ECMO flow cessation. Early detection and timely circuit exchange is critical yet challenging. Acute clot formation necessitates immediate circuit replacement, while premature replacement risks unnecessary procedural harm and increased costs. No reliable method exists to detect early oxygenator thrombosis. Strategies include visual inspection, monitoring the pressure difference across the oxygenator (\u0394<jats:italic>P<\/jats:italic>\n              <jats:sub>oxy<\/jats:sub>), gas exchange evaluation, and blood tests. In the present animal study, we aimed to evaluate the feasibility of accelerometer-based vibration analysis as a real-time and non-invasive method for detecting oxygenator thrombosis during VV ECMO. We hypothesized that accelerometer signals would change concurrently with or precede increases in \u0394<jats:italic>P<\/jats:italic>\n              <jats:sub>oxy<\/jats:sub>.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>The study was performed on anesthetized and mechanically ventilated pigs (<jats:italic>n<\/jats:italic>\u2009=\u20097) on VV ECMO. Hemodynamic parameters, ECMO circuit pressures, and signals from an accelerometer attached to the ECMO oxygenator were continuously recorded at different pump speeds, and after anticoagulation reversal to promote thrombosis within the ECMO oxygenator.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The primary finding of this study was a significant increase in the accelerometer signal's Root Mean Squared (RMS<jats:sub>oxy<\/jats:sub>) 15\u00a0min after anticoagulation reversal, with no rpm adjustment and without corresponding changes in \u0394<jats:italic>P<\/jats:italic>\n              <jats:sub>oxy<\/jats:sub>. Variations in RMS<jats:sub>oxy<\/jats:sub> associated with high ECMO pump speed and circuit flow were discernible from those observed following anticoagulation reversal.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The present animal study demonstrates the feasibility of accelerometer-based vibration analysis as a real-time and non-invasive method for detecting vibrations associated with reversal of anticoagulation and potential oxygenator thrombosis during VV ECMO.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40635-025-00763-7","type":"journal-article","created":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T18:41:17Z","timestamp":1748889677000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accelerometer-based vibration analysis and oxygenator thrombosis in venovenous ECMO: an experimental porcine model"],"prefix":"10.1186","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-0783-6405","authenticated-orcid":false,"given":"Lars Prag","family":"Antonsen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Svein Aslak","family":"Landsverk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Per Steinar","family":"Halvorsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amrit","family":"Thiara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Didrik","family":"Lilja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naimahmed","family":"Nesaragi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Espinoza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,2]]},"reference":[{"issue":"1","key":"763_CR1","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1097\/MAT.0000000000000475","volume":"63","author":"RR Thiagarajan","year":"2017","unstructured":"Thiagarajan RR, Barbaro RP, Rycus PT, McMullan DM, Conrad SA, Fortenberry JD et al (2017) Extracorporeal life support organization registry international report 2016. Asaio J 63(1):60\u201367","journal-title":"Asaio J"},{"key":"763_CR2","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.jcrc.2017.02.014","volume":"39","author":"E Sy","year":"2017","unstructured":"Sy E, Sklar MC, Lequier L, Fan E, Kanji HD (2017) Anticoagulation practices and the prevalence of major bleeding, thromboembolic events, and mortality in venoarterial extracorporeal membrane oxygenation: a systematic review and meta-analysis. J Crit Care 39:87\u201396","journal-title":"J Crit Care"},{"issue":"2","key":"763_CR3","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1007\/s00134-021-06593-x","volume":"48","author":"JI Nunez","year":"2022","unstructured":"Nunez JI, Gosling AF, O\u2019Gara B, Kennedy KF, Rycus P, Abrams D et al (2022) Bleeding and thrombotic events in adults supported with venovenous extracorporeal membrane oxygenation: an ELSO registry analysis. Intensive Care Med 48(2):213\u2013224","journal-title":"Intensive Care Med"},{"issue":"3","key":"763_CR4","first-page":"172","volume":"15","author":"A Zangrillo","year":"2013","unstructured":"Zangrillo A, Landoni G, Biondi-Zoccai G, Greco M, Greco T, Frati G et al (2013) A meta-analysis of complications and mortality of extracorporeal membrane oxygenation. Crit Care Resusc 15(3):172\u2013178","journal-title":"Crit Care Resusc"},{"issue":"3","key":"763_CR5","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1177\/0267659115595282","volume":"31","author":"KC Pan","year":"2016","unstructured":"Pan KC, McKenzie DP, Pellegrino V, Murphy D, Butt W (2016) The meaning of a high plasma free haemoglobin: retrospective review of the prevalence of haemolysis and circuit thrombosis in an adult ECMO centre over 5 years. Perfusion 31(3):223\u2013231","journal-title":"Perfusion"},{"issue":"12","key":"763_CR6","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0112316","volume":"9","author":"M Lubnow","year":"2014","unstructured":"Lubnow M, Philipp A, Foltan M, Bull Enger T, Lunz D, Bein T et al (2014) Technical complications during veno-venous extracorporeal membrane oxygenation and their relevance predicting a system-exchange\u2013retrospective analysis of 265 cases. PLoS ONE 9(12):e112316","journal-title":"PLoS ONE"},{"issue":"4","key":"763_CR7","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1080\/09537104.2021.1961707","volume":"33","author":"TCL Kohs","year":"2022","unstructured":"Kohs TCL, Liu P, Raghunathan V, Amirsoltani R, Oakes M, McCarty OJT et al (2022) Severe thrombocytopenia in adults undergoing extracorporeal membrane oxygenation is predictive of thrombosis. Platelets 33(4):570\u2013576","journal-title":"Platelets"},{"issue":"8","key":"763_CR8","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1007\/s00134-022-06794-y","volume":"48","author":"A Mansour","year":"2022","unstructured":"Mansour A, Flecher E, Schmidt M, Rozec B, Gouin-Thibault I, Esvan M et al (2022) Bleeding and thrombotic events in patients with severe COVID-19 supported with extracorporeal membrane oxygenation: a nationwide cohort study. Intensive Care Med 48(8):1039\u20131052","journal-title":"Intensive Care Med"},{"issue":"2","key":"763_CR9","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1055\/s-0043-1772843","volume":"50","author":"J Leerson","year":"2024","unstructured":"Leerson J, Tulloh A, Lopez FT, Gregory S, Buscher H, Rosengarten G (2024) Detecting oxygenator thrombosis in ECMO: a review of current techniques and an exploration of future directions. Semin Thromb Hemost 50(2):253\u2013270","journal-title":"Semin Thromb Hemost"},{"issue":"2","key":"763_CR10","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1097\/MAT.0000000000001630","volume":"68","author":"EF Gajkowski","year":"2022","unstructured":"Gajkowski EF, Herrera G, Hatton L, Velia Antonini M, Vercaemst L, Cooley E (2022) ELSO guidelines for adult and pediatric extracorporeal membrane oxygenation circuits. Asaio J 68(2):133\u2013152","journal-title":"Asaio J"},{"issue":"3","key":"763_CR11","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1097\/MAT.0000000000001652","volume":"68","author":"ABV McMichael","year":"2022","unstructured":"McMichael ABV, Ryerson LM, Ratano D, Fan E, Faraoni D, Annich GM (2022) 2021 ELSO adult and pediatric anticoagulation guidelines. Asaio J 68(3):303\u2013310","journal-title":"Asaio J"},{"issue":"1","key":"763_CR12","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s12959-023-00452-z","volume":"21","author":"S Zeibi Shirejini","year":"2023","unstructured":"Zeibi Shirejini S, Carberry J, McQuilten ZK, Burrell AJC, Gregory SD, Hagemeyer CE (2023) Current and future strategies to monitor and manage coagulation in ECMO patients. Thromb J 21(1):11","journal-title":"Thromb J"},{"issue":"3","key":"763_CR13","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3390\/s24030740","volume":"24","author":"IU Hassan","year":"2024","unstructured":"Hassan IU, Panduru K, Walsh J (2024) An in-depth study of vibration sensors for condition monitoring. Sensors 24(3):740","journal-title":"Sensors"},{"key":"763_CR14","first-page":"12","volume":"2","author":"W Mohamedi","year":"2024","unstructured":"Mohamedi W (2024) Application of vibration analysis for medical diagnosis. Progress Med Devices 2:12\u201318","journal-title":"Progress Med Devices"},{"issue":"9","key":"763_CR15","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1097\/MAT.0000000000001654","volume":"68","author":"I Schalit","year":"2022","unstructured":"Schalit I, Espinoza A, Pettersen F-J, Skulstad H, Fosse E, Fiane AE et al (2022) Improved detection of thromboembolic complications in left ventricular assist device by novel accelerometer-based analysis. ASAIO J 68(9):1117\u20131125","journal-title":"ASAIO J"},{"issue":"8","key":"763_CR16","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/j.healun.2023.03.017","volume":"42","author":"D Lilja","year":"2023","unstructured":"Lilja D, Schalit I, Espinoza A, Fiane AE, Dahle G, Littorin-Sandbu H et al (2023) Detection of inflow obstruction in left ventricular assist devices by accelerometer: a porcine model study. J Heart Lung Transplant 42(8):1005\u20131014","journal-title":"J Heart Lung Transplant"},{"issue":"5","key":"763_CR17","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1097\/MAT.0000000000000699","volume":"64","author":"I Schalit","year":"2018","unstructured":"Schalit I, Espinoza A, Pettersen FJ, Thiara APS, Karlsen H, S\u00f8rensen G et al (2018) Accelerometer detects pump thrombosis and thromboembolic events in an in vitro HVAD circuit. Asaio J 64(5):601\u2013609","journal-title":"Asaio J"},{"issue":"1","key":"763_CR18","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1097\/MAT.0000000000000954","volume":"66","author":"I Schalit","year":"2020","unstructured":"Schalit I, Espinoza A, Pettersen FJ, Snartland S, Ringdal ML, Hoel TN et al (2020) Detection of thromboembolic events and pump thrombosis in HeartWare HVAD using accelerometer in a porcine model. Asaio J 66(1):38\u201348","journal-title":"Asaio J"},{"key":"763_CR19","doi-asserted-by":"publisher","first-page":"103917","DOI":"10.1016\/j.medengphy.2022.103917","volume":"110","author":"D Lilja","year":"2022","unstructured":"Lilja D, Schalit I, Espinoza A, Pettersen FJ, Elle OJ, Halvorsen PS (2022) Detection of inflow obstruction in left ventricular assist devices by accelerometer: an in vitro study. Med Eng Phys 110:103917","journal-title":"Med Eng Phys"},{"issue":"1","key":"763_CR20","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.healun.2023.08.022","volume":"43","author":"D Lilja","year":"2024","unstructured":"Lilja D, Schalit I, Espinoza A, Hoel TN, Larsen G, Pettersen FJ et al (2024) Extracorporeal driveline vibrations to detect left ventricular assist device thrombosis\u2014A porcine model study. J Heart Lung Transplant 43(1):111\u2013119","journal-title":"J Heart Lung Transplant"},{"issue":"1","key":"763_CR21","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s40635-024-00636-5","volume":"12","author":"LP Antonsen","year":"2024","unstructured":"Antonsen LP, Espinoza A, Halvorsen PS, Schalit I, Bergan H, Lilja D et al (2024) The impact of hypovolemia and PEEP on recirculation in venovenous ECMO: an experimental porcine model. Intensive Care Med Exp 12(1):51","journal-title":"Intensive Care Med Exp"},{"issue":"9","key":"763_CR22","doi-asserted-by":"publisher","first-page":"1769","DOI":"10.1177\/0271678X20943823","volume":"40","author":"N Percie du Sert","year":"2020","unstructured":"Percie du Sert N, Hurst V, Ahluwalia A, Alam S, Avey MT, Baker M et al (2020) The ARRIVE guidelines 2.0: updated guidelines for reporting animal research. J Cerebral Blood Flow Metab. 40(9):1769\u20131777","journal-title":"J Cerebral Blood Flow Metab."},{"key":"763_CR23","unstructured":"European Parliament CotEU. Directive 2010\/63\/EU of 22 September 2010 on the protection of animals used for scientific purposes: Official Journal of the European Union; 2010 [76\u20139]. https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/HTML\/?uri=CELEX:32010L0063. Accessed 05 Mar 25."},{"issue":"5","key":"763_CR24","first-page":"432","volume":"53","author":"PP Lelovas","year":"2014","unstructured":"Lelovas PP, Kostomitsopoulos NG, Xanthos TT (2014) A comparative anatomic and physiologic overview of the porcine heart. J Am Assoc Lab Anim Sci 53(5):432\u2013438","journal-title":"J Am Assoc Lab Anim Sci"},{"issue":"6","key":"763_CR25","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1111\/aor.12782","volume":"41","author":"G Fuchs","year":"2017","unstructured":"Fuchs G, Berg N, Eriksson A, Prahl WL (2017) Detection of thrombosis in the extracorporeal membrane oxygenation circuit by infrasound: proof of concept. Artif Organs 41(6):573\u2013579","journal-title":"Artif Organs"},{"issue":"1_suppl","key":"763_CR26","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1177\/0267659118765883","volume":"33","author":"N Krivitski","year":"2018","unstructured":"Krivitski N, Galyanov G, Cooper D, Said MM, Rivera O, Mikesell GT et al (2018) In vitro and in vivo assessment of oxygenator blood volume for the prediction of clot formation in an ECMO circuit (theory and validation). Perfusion 33(1_suppl):51\u201356","journal-title":"Perfusion"},{"issue":"2","key":"763_CR27","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1111\/aor.13343","volume":"43","author":"A Kaesler","year":"2019","unstructured":"Kaesler A, Hesselmann F, Zander MO, Schlanstein PC, Wagner G, Bruners P et al (2019) Technical indicators to evaluate the degree of large clot formation inside the membrane fiber bundle of an oxygenator in an in vitro setup. Artif Organs 43(2):159\u2013166","journal-title":"Artif Organs"},{"issue":"5 Suppl 1","key":"763_CR28","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1097\/PCC.0b013e318292dd10","volume":"14","author":"L Lequier","year":"2013","unstructured":"Lequier L, Horton SB, McMullan DM, Bartlett RH (2013) Extracorporeal membrane oxygenation circuitry. Pediatr Crit Care Med 14(5 Suppl 1):S7-12","journal-title":"Pediatr Crit Care Med"},{"issue":"6","key":"763_CR29","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1097\/MAT.0b013e318186a807","volume":"54","author":"K Lehle","year":"2008","unstructured":"Lehle K, Philipp A, Gleich O, Holzamer A, M\u00fcller T, Bein T et al (2008) Efficiency in extracorporeal membrane oxygenation\u2014cellular deposits on polymethypentene membranes increase resistance to blood flow and reduce gas exchange capacity. ASAIO J 54(6):612\u2013617","journal-title":"ASAIO J"},{"issue":"5","key":"763_CR30","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1111\/aor.12180","volume":"38","author":"K Lehle","year":"2014","unstructured":"Lehle K, Philipp A, M\u00fcller T, Schettler F, Bein T, Schmid C et al (2014) Flow dynamics of different adult ECMO systems: a clinical evaluation. Artif Organs 38(5):391\u2013398","journal-title":"Artif Organs"},{"issue":"12","key":"763_CR31","doi-asserted-by":"publisher","first-page":"3636","DOI":"10.1007\/s10439-021-02878-w","volume":"49","author":"S Sarathy","year":"2021","unstructured":"Sarathy S, Turek JW, Chu J, Badheka A, Nino MA, Raghavan ML (2021) Flow monitoring of ECMO circuit for detecting oxygenator obstructions. Ann Biomed Eng 49(12):3636\u20133646","journal-title":"Ann Biomed Eng"},{"issue":"4","key":"763_CR32","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1177\/0267659116678679","volume":"32","author":"CF Evans","year":"2017","unstructured":"Evans CF, Li T, Mishra V, Pratt DL, Mohammed ISK, Kon ZN et al (2017) Externally visible thrombus partially predicts internal thrombus deposition in extracorporeal membrane oxygenators. Perfusion 32(4):301\u2013305","journal-title":"Perfusion"},{"issue":"2","key":"763_CR33","doi-asserted-by":"publisher","first-page":"441.e7","DOI":"10.1016\/j.jcrc.2014.12.005","volume":"30","author":"M Panigada","year":"2015","unstructured":"Panigada M, L\u2019Acqua C, Passamonti SM, Mietto C, Protti A, Riva R et al (2015) Comparison between clinical indicators of transmembrane oxygenator thrombosis and multidetector computed tomographic analysis. J Crit Care 30(2):441.e7\u201313","journal-title":"J Crit Care"},{"issue":"9","key":"763_CR34","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1111\/aor.12460","volume":"39","author":"C Dornia","year":"2015","unstructured":"Dornia C, Philipp A, Bauer S, Stroszczynski C, Schreyer AG, M\u00fcller T et al (2015) D-dimers are a predictor of clot volume inside membrane oxygenators during extracorporeal membrane oxygenation. Artif Organs 39(9):782\u2013787","journal-title":"Artif Organs"},{"issue":"19","key":"763_CR35","doi-asserted-by":"publisher","first-page":"2411","DOI":"10.1016\/j.jacc.2017.09.024","volume":"70","author":"JI Weitz","year":"2017","unstructured":"Weitz JI, Fredenburgh JC, Eikelboom JW (2017) A test in context: D-dimer. J Am Coll Cardiol 70(19):2411\u20132420","journal-title":"J Am Coll Cardiol"},{"issue":"7","key":"763_CR36","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1055\/s-0032-1326782","volume":"38","author":"SM Bates","year":"2012","unstructured":"Bates SM (2012) D-dimer assays in diagnosis and management of thrombotic and bleeding disorders. Semin Thromb Hemost 38(7):673\u2013682","journal-title":"Semin Thromb Hemost"},{"issue":"3","key":"763_CR37","doi-asserted-by":"publisher","first-page":"473.e1","DOI":"10.1016\/j.jcrc.2013.12.008","volume":"29","author":"M Lubnow","year":"2014","unstructured":"Lubnow M, Philipp A, Dornia C, Schroll S, Bein T, Creutzenberg M et al (2014) D-dimers as an early marker for oxygenator exchange in extracorporeal membrane oxygenation. J Crit Care 29(3):473.e1\u20135","journal-title":"J Crit Care"},{"issue":"1","key":"763_CR38","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1186\/s13054-017-1788-9","volume":"21","author":"MR Passmore","year":"2017","unstructured":"Passmore MR, Fung YL, Simonova G, Foley SR, Diab SD, Dunster KR et al (2017) Evidence of altered haemostasis in an ovine model of venovenous extracorporeal membrane oxygenation support. Crit Care 21(1):191","journal-title":"Crit Care"},{"issue":"Pt 6","key":"763_CR39","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1258\/0004563042466884","volume":"41","author":"GD Lowe","year":"2004","unstructured":"Lowe GD, Rumley A, Mackie IJ (2004) Plasma fibrinogen. Ann Clin Biochem 41(Pt 6):430\u2013440","journal-title":"Ann Clin Biochem"},{"issue":"1","key":"763_CR40","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.jcrc.2015.09.010","volume":"31","author":"M Di Nardo","year":"2016","unstructured":"Di Nardo M, Merli P, Cecchetti C, Pasotti E, Bertaina A, Locatelli F (2016) Progressive increase in D-dimer levels during extracorporeal membrane oxygenation can predict membrane oxygenator failure in children given hematopoietic stem cell transplantation? J Crit Care 31(1):262\u2013263","journal-title":"J Crit Care"},{"issue":"6","key":"763_CR41","first-page":"612","volume":"85","author":"RL Gauer","year":"2012","unstructured":"Gauer RL, Braun MM (2012) Thrombocytopenia. Am Fam Physician 85(6):612\u2013622","journal-title":"Am Fam Physician"},{"issue":"4","key":"763_CR42","doi-asserted-by":"publisher","first-page":"e175","DOI":"10.1097\/PCC.0000000000000101","volume":"15","author":"K Irby","year":"2014","unstructured":"Irby K, Swearingen C, Byrnes J, Bryant J, Prodhan P, Fiser R (2014) Unfractionated heparin activity measured by anti-factor Xa levels is associated with the need for extracorporeal membrane oxygenation circuit\/membrane oxygenator change: a retrospective pediatric study. Pediatr Crit Care Med 15(4):e175\u2013e182","journal-title":"Pediatr Crit Care Med"},{"issue":"6","key":"763_CR43","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1002\/j.1875-9114.2011.01049.x","volume":"32","author":"JW Vandiver","year":"2012","unstructured":"Vandiver JW, Vondracek TG (2012) Antifactor Xa levels versus activated partial thromboplastin time for monitoring unfractionated heparin. Pharmacotherapy 32(6):546\u2013558","journal-title":"Pharmacotherapy"},{"issue":"6","key":"763_CR44","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1164\/rccm.201609-1945OC","volume":"196","author":"HJ Dalton","year":"2017","unstructured":"Dalton HJ, Reeder R, Garcia-Filion P, Holubkov R, Berg RA, Zuppa A et al (2017) Factors associated with bleeding and thrombosis in children receiving extracorporeal membrane oxygenation. Am J Respir Crit Care Med 196(6):762\u2013771","journal-title":"Am J Respir Crit Care Med"},{"issue":"3","key":"763_CR45","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1051\/ject\/201850149","volume":"50","author":"N Henderson","year":"2018","unstructured":"Henderson N, Sullivan JE, Myers J, Wells T, Calhoun A, Berkenbosch J et al (2018) Use of thromboelastography to predict thrombotic complications in pediatric and neonatal extracorporeal membranous oxygenation. J Extra Corpor Technol 50(3):149\u2013154","journal-title":"J Extra Corpor Technol"},{"issue":"8","key":"763_CR46","doi-asserted-by":"publisher","first-page":"3325","DOI":"10.21037\/jtd.2019.08.44","volume":"11","author":"E Colman","year":"2019","unstructured":"Colman E, Yin EB, Laine G, Chatterjee S, Saatee S, Herlihy JP et al (2019) Evaluation of a heparin monitoring protocol for extracorporeal membrane oxygenation and review of the literature. J Thorac Dis 11(8):3325\u20133335","journal-title":"J Thorac Dis"},{"issue":"1","key":"763_CR47","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s13613-017-0352-8","volume":"8","author":"M Panigada","year":"2018","unstructured":"Panigada M, Iapichino GE, Brioni M, Panarello G, Protti A, Grasselli G et al (2018) Thromboelastography-based anticoagulation management during extracorporeal membrane oxygenation: a safety and feasibility pilot study. Ann Intensive Care 8(1):7","journal-title":"Ann Intensive Care"},{"issue":"2","key":"763_CR48","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1051\/ject\/201951061","volume":"51","author":"R Basken","year":"2019","unstructured":"Basken R, Cosgrove R, Malo J, Romero A, Patanwala A, Finger J et al (2019) Predictors of oxygenator exchange in patients receiving extracorporeal membrane oxygenation. J Extra Corpor Technol 51(2):61\u201366","journal-title":"J Extra Corpor Technol"},{"issue":"5","key":"763_CR49","doi-asserted-by":"publisher","DOI":"10.1002\/rth2.12553","volume":"5","author":"JG Drop","year":"2021","unstructured":"Drop JG, Erdem \u00d6, Wildschut ED, van Rosmalen J, de Maat MPM, Kuiper JW et al (2021) Use of rotational thromboelastometry to predict hemostatic complications in pediatric patients undergoing extracorporeal membrane oxygenation: a retrospective cohort study. Res Pract Thromb Haemost 5(5):e12553","journal-title":"Res Pract Thromb Haemost"},{"issue":"4","key":"763_CR50","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1097\/MAT.0000000000000538","volume":"63","author":"A Badheka","year":"2017","unstructured":"Badheka A, Stucker SE, Turek JW, Raghavan ML (2017) Efficacy of flow monitoring during ECMO. Asaio j 63(4):496\u2013500","journal-title":"Asaio j"},{"issue":"7","key":"763_CR51","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1177\/0267659119833233","volume":"34","author":"A Montalti","year":"2019","unstructured":"Montalti A, Belliato M, Gelsomino S, Nalon S, Matteucci F, Parise O et al (2019) Continuous monitoring of membrane lung carbon dioxide removal during ECMO: experimental testing of a new volumetric capnometer. Perfusion 34(7):538\u2013543","journal-title":"Perfusion"},{"issue":"10","key":"763_CR52","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1111\/aor.13999","volume":"45","author":"H Sakurai","year":"2021","unstructured":"Sakurai H, Fujiwara T, Ohuchi K, Hijikata W, Inoue Y, Seki H et al (2021) Novel application of indocyanine green fluorescence imaging for real-time detection of thrombus in a membrane oxygenator. Artif Organs 45(10):1173\u20131182","journal-title":"Artif Organs"},{"issue":"2","key":"763_CR53","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1007\/s13239-021-00579-y","volume":"13","author":"A Kaesler","year":"2022","unstructured":"Kaesler A, Rudawski FL, Zander MO, Hesselmann F, Pinar I, Schmitz-Rode T et al (2022) In-vitro visualization of thrombus growth in artificial lungs using real-time X-ray imaging: a feasibility study. Cardiovasc Eng Technol 13(2):318\u2013330","journal-title":"Cardiovasc Eng Technol"},{"issue":"8","key":"763_CR54","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1177\/0391398820978656","volume":"44","author":"N Morita","year":"2021","unstructured":"Morita N, Sakota D, Oota-Ishigaki A, Kosaka R, Maruyama O, Nishida M et al (2021) Real-time, non-invasive thrombus detection in an extracorporeal circuit using micro-optical thrombus sensors. Int J Artif Organs 44(8):565\u2013573","journal-title":"Int J Artif Organs"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-025-00763-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-025-00763-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-025-00763-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T20:02:09Z","timestamp":1748894529000},"score":1,"resource":{"primary":{"URL":"https:\/\/icm-experimental.springeropen.com\/articles\/10.1186\/s40635-025-00763-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,2]]},"references-count":54,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["763"],"URL":"https:\/\/doi.org\/10.1186\/s40635-025-00763-7","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,2]]},"assertion":[{"value":"7 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The experimental protocol (trial registration number 24306 and 28798) was approved by the Norwegian National Animal Research Authority and were performed in accordance with European legislation. (European Parliament CotEU. Directive 2010\/63\/EU of 22 September 2010 on the protection of animals used for scientific purposes: Official Journal of the European Union; 2010 [76\u20139]. Available from:  EN\/ TXT\/HTML\/?uri\u2009=\u2009CELEX:32010L0063.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"SH and AE are shareholders in Cardiaccs AS. The other authors declare no other competing interests related to this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"55"}}