{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:27:43Z","timestamp":1787023663212,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:00:00Z","timestamp":1787011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:00:00Z","timestamp":1787011200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Mechanical power (MP) quantifies the energy transferred from the ventilator to the respiratory system and is increasingly linked to outcomes in invasively ventilated critically ill patients. Limiting MP may support lung-protective ventilation by integrating key determinants of ventilator-induced lung injury. While geometric MP, derived from pressure\u2013volume loops, is considered the reference standard, it is not readily available at the bedside. Therefore, simplified equations are commonly used, although their agreement remains uncertain. This study evaluates the agreement of previously proposed equations to estimate inspiratory MP compared with a geometric reference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>494 paired values of geometric and estimated MP were collected, in 38 passively ventilated patients during closed-loop ventilation and during conventional ventilation. The median geometric MP was 17.0 [12.3\u201321.5] J\/min. Correlation between geometric and estimated MP ranged from strong to very strong. Agreement between geometric and estimated MP was good, though bias and limits of agreement varied across the different equations. ROC analysis showed excellent discrimination for most equations across all tested cutoffs, with discrimination gradually declining at higher MP levels.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In passively ventilated critically ill patients, estimated MP showed strong to very strong correlations with the geometric reference. ROC analysis confirmed excellent discrimination, but Bland\u2013Altman analysis revealed considerable variability, suggesting potential limitations in using these equations interchangeably in clinical or research settings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study registration<\/jats:title>\n                    <jats:p>INTELLiPOWER was registered at clinicaltrials.gov (study identifier NCT04827927).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40635-026-00956-8","type":"journal-article","created":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:09:03Z","timestamp":1787022543000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Discrepancies between estimated and geometrically derived mechanical power in invasively ventilated patients \u2013 insights from a randomized clinical trial"],"prefix":"10.1186","volume":"14","author":[{"given":"Simon Corrado","family":"Serafini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Willem H. J.","family":"Geerts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ary Serpa","family":"Neto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie S.","family":"List","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"von D\u00fcring","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edda","family":"Tschernko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"B\u00fchler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guido","family":"Mazzinari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederique","family":"Paulus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus J.","family":"Schultz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9569-2462","authenticated-orcid":false,"given":"Laura A.","family":"Buiteman\u2013Kruizinga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"for the INTELLiPOWER collaborative investigators","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rik J.A.","family":"Appel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda","family":"van den Berg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marjolein C.W.M.","family":"Bierlee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ben H.","family":"de Boer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danique","family":"Boezaart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 A.","family":"Boots","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michela","family":"Botta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bibi","family":"Bosman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"B\u00fchler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura A.","family":"Buiteman\u2013Kruizinga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kim\u2013Jana","family":"Fehlbier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin L.","family":"Goossen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anastasia A.","family":"Guseva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pim L.J.","family":"van der Heiden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Coby","family":"Hoekstra\u2013Kapitein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eva\u2013Maria","family":"Kleinert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans","family":"Last","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias D.","family":"van Leijsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie S.","family":"List","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marieke","family":"Luttmer\u2013Laven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederique","family":"Paulus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lotte","family":"Remmerswaal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yvonne Schriel","family":"van den Berg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus J.","family":"Schultz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ary Serpa","family":"Neto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jante S.","family":"Sinnige","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anissa M.","family":"Tsonas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia","family":"van Velzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"Vermeulen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Wendel Garcia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,18]]},"reference":[{"issue":"10","key":"956_CR1","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1007\/s00134-016-4505-2","volume":"42","author":"L Gattinoni","year":"2016","unstructured":"Gattinoni L, Tonetti T, Cressoni M, Cadringher P, Herrmann P, Moerer O et al (2016) Ventilator-related causes of lung injury: the mechanical power. Intensive Care Med 42(10):1567\u20131575","journal-title":"Intensive Care Med"},{"issue":"9","key":"956_CR2","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1007\/s00134-019-05636-8","volume":"45","author":"T Becher","year":"2019","unstructured":"Becher T, van der Staay M, Schadler D, Frerichs I, Weiler N (2019) Calculation of mechanical power for pressure-controlled ventilation. Intensive Care Med 45(9):1321\u20131323","journal-title":"Intensive Care Med"},{"issue":"1","key":"956_CR3","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1186\/s13054-016-1556-2","volume":"20","author":"C Guerin","year":"2016","unstructured":"Guerin C, Papazian L, Reignier J, Ayzac L, Loundou A, Forel JM (2016) Effect of driving pressure on mortality in ARDS patients during lung protective mechanical ventilation in two randomized controlled trials. Crit Care 20(1):384","journal-title":"Crit Care"},{"issue":"3","key":"956_CR4","volume":"7","author":"JWM Snoep","year":"2025","unstructured":"Snoep JWM, Rietveld PJ, van der Velde-Quist F, de Jonge E, Schoe A (2025) Mechanical power in pressure-controlled ventilation: a simple and reliable bedside method. Crit Care Explor 7(3):e1224","journal-title":"Crit Care Explor"},{"key":"956_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrc.2024.154902","volume":"85","author":"S von During","year":"2025","unstructured":"von During S, Parhar KKS, Adhikari NKJ, Urner M, Kim SJ, Munshi L et al (2025) Understanding ventilator-induced lung injury: the role of mechanical power. J Crit Care 85:154902","journal-title":"J Crit Care"},{"issue":"1","key":"956_CR6","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1186\/s40635-019-0276-8","volume":"7","author":"L Giosa","year":"2019","unstructured":"Giosa L, Busana M, Pasticci I, Bonifazi M, Macri MM, Romitti F et al (2019) Mechanical power at a glance: a simple surrogate for volume-controlled ventilation. Intensive Care Med Exp 7(1):61","journal-title":"Intensive Care Med Exp"},{"issue":"10","key":"956_CR7","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1007\/s00134-019-05698-8","volume":"45","author":"S van der Meijden","year":"2019","unstructured":"van der Meijden S, Molenaar M, Somhorst P, Schoe A (2019) Calculating mechanical power for pressure-controlled ventilation. Intensive Care Med 45(10):1495\u20131497","journal-title":"Intensive Care Med"},{"issue":"1","key":"956_CR8","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s40635-022-00448-5","volume":"10","author":"CA Trinkle","year":"2022","unstructured":"Trinkle CA, Broaddus RN, Sturgill JL, Waters CM, Morris PE (2022) Simple, accurate calculation of mechanical power in pressure controlled ventilation (PCV). Intensive Care Med Exp 10(1):22","journal-title":"Intensive Care Med Exp"},{"issue":"1","key":"956_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-020-02963-x","volume":"24","author":"S Coppola","year":"2020","unstructured":"Coppola S, Caccioppola A, Froio S, Formenti P, De Giorgis V, Galanti V et al (2020) Effect of mechanical power on intensive care mortality in ARDS patients. Crit Care 24(1):246","journal-title":"Crit Care"},{"issue":"3","key":"956_CR10","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1164\/rccm.202009-3467OC","volume":"204","author":"ELV Costa","year":"2021","unstructured":"Costa ELV, Slutsky AS, Brochard LJ, Brower R, Serpa-Neto A, Cavalcanti AB et al (2021) Ventilatory variables and mechanical power in patients with acute respiratory distress syndrome. Am J Respir Crit Care Med 204(3):303\u2013311","journal-title":"Am J Respir Crit Care Med"},{"key":"956_CR11","doi-asserted-by":"crossref","unstructured":"Serpa Neto A DR, Johnson AEW, Bos LD, Amorim P, et al. Mechanical power of ventilation is associated with mortality in critically ill patients: an analysis of patients in two observational cohorts. Intensive Care Med Exp. 2018;7.","DOI":"10.1007\/s00134-018-5375-6"},{"issue":"9","key":"956_CR12","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/S2213-2600(20)30325-8","volume":"8","author":"M Urner","year":"2020","unstructured":"Urner M, Juni P, Hansen B, Wettstein MS, Ferguson ND, Fan E (2020) Time-varying intensity of mechanical ventilation and mortality in patients with acute respiratory failure: a registry-based, prospective cohort study. Lancet Respir Med 8(9):905\u2013913","journal-title":"Lancet Respir Med"},{"issue":"1","key":"956_CR13","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1097\/EJA.0000000000001778","volume":"40","author":"DMP van Meenen","year":"2023","unstructured":"van Meenen DMP, Algera AG, Schuijt MTU, Simonis FD, van der Hoeven SM, Neto AS et al (2023) Effect of mechanical power on mortality in invasively ventilated ICU patients without the acute respiratory distress syndrome: An analysis of three randomised clinical trials. Eur J Anaesthesiol 40(1):21\u201328","journal-title":"Eur J Anaesthesiol"},{"key":"956_CR14","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.00742-2025","author":"E Rezoagli","year":"2026","unstructured":"Rezoagli E, Laffey JG, Madotto F, Protti A, Pham T, Pesenti A et al (2026) Prognostic value of disease severity and mechanical ventilation intensity in acute respiratory distress syndrome: analysis of the LUNG SAFE cohort. Eur Respir J. https:\/\/doi.org\/10.1183\/13993003.00742-2025","journal-title":"Eur Respir J"},{"issue":"1","key":"956_CR15","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-020-03116-w","volume":"24","author":"D Chiumello","year":"2020","unstructured":"Chiumello D, Gotti M, Guanziroli M, Formenti P, Umbrello M, Pasticci I et al (2020) Bedside calculation of mechanical power during volume- and pressure-controlled mechanical ventilation. Crit Care 24(1):417","journal-title":"Crit Care"},{"issue":"6","key":"956_CR16","doi-asserted-by":"publisher","first-page":"3237","DOI":"10.21037\/jtd-22-1409","volume":"15","author":"H Zheng","year":"2023","unstructured":"Zheng H, Xu Z, Zhou J, Lin Z, Wang Y, He W et al (2023) The accuracy of simplified calculation of mechanical power: a simulation study. J Thorac Dis 15(6):3237\u20133244","journal-title":"J Thorac Dis"},{"issue":"1","key":"956_CR17","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1378\/chest.89.1.56","volume":"89","author":"JJ Marini","year":"1986","unstructured":"Marini JJ, Rodriguez RM, Lamb V (1986) Bedside estimation of the inspiratory work of breathing during mechanical ventilation. Chest 89(1):56\u201363","journal-title":"Chest"},{"issue":"5","key":"956_CR18","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1007\/s00134-019-05521-4","volume":"45","author":"B Louis","year":"2019","unstructured":"Louis B, Guerin C (2019) Comparison of geometric and algebraic methods to determine mechanical power in patients with acute respiratory distress syndrome. Intensive Care Med 45(5):738\u2013740","journal-title":"Intensive Care Med"},{"issue":"7","key":"956_CR19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0307155","volume":"19","author":"LA Buiteman-Kruizinga","year":"2024","unstructured":"Buiteman-Kruizinga LA, Serpa Neto A, Botta M, List SS, de Boer BH, van Velzen P et al (2024) Effect of automated versus conventional ventilation on mechanical power of ventilation-A randomized crossover clinical trial. PLoS One 19(7):e0307155","journal-title":"PLoS One"},{"key":"956_CR20","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10225409","author":"LA Buiteman-Kruizinga","year":"2021","unstructured":"Buiteman-Kruizinga LA, Mkadmi HE, Serpa Neto A, Kruizinga MD, Botta M, Schultz MJ et al (2021) Effect of INTELLiVENT-ASV versus conventional ventilation on ventilation intensity in patients with COVID-19 ARDS-an observational study. J Clin Med. https:\/\/doi.org\/10.3390\/jcm10225409","journal-title":"J Clin Med"},{"issue":"5","key":"956_CR21","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1097\/ALN.0000000000001056","volume":"124","author":"M Cressoni","year":"2016","unstructured":"Cressoni M, Gotti M, Chiurazzi C, Massari D, Algieri I, Amini M et al (2016) Mechanical power and development of ventilator-induced lung injury. Anesthesiology 124(5):1100\u20131108","journal-title":"Anesthesiology"},{"issue":"3","key":"956_CR22","doi-asserted-by":"publisher","first-page":"349","DOI":"10.4187\/respcare.11280","volume":"69","author":"A Santarisi","year":"2024","unstructured":"Santarisi A, Suleiman A, Talmor DS, Goodspeed V, Schaefer MS, Baedorf Kassis EN (2024) Simplified mechanical power calculation in patients receiving pressure-regulated, volume-targeted hybrid modes of ventilation. Respir Care 69(3):349\u2013353","journal-title":"Respir Care"},{"issue":"7","key":"956_CR23","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1164\/rccm.202307-1292VP","volume":"209","author":"JHT Bates","year":"2024","unstructured":"Bates JHT, Kaczka DW, Kollisch-Singule M, Nieman GF, Gaver DP 3rd (2024) Mechanical power and ventilator-induced lung injury: what does physics have to say? Am J Respir Crit Care Med 209(7):787\u2013788","journal-title":"Am J Respir Crit Care Med"},{"issue":"5","key":"956_CR24","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.1152\/japplphysiol.00426.2022","volume":"133","author":"M Busana","year":"1985","unstructured":"Busana M, Zinnato C, Romitti F, Palumbo M, Gattarello S, Sonzogni A et al (1985) Energy dissipation during expiration and ventilator-induced lung injury: an experimental animal study. J Appl Physiol 133(5):1212\u20131219","journal-title":"J Appl Physiol"},{"issue":"4","key":"956_CR25","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1007\/s00134-023-06991-3","volume":"49","author":"L Gattinoni","year":"2023","unstructured":"Gattinoni L, Collino F, Camporota L (2023) Mechanical power: meaning, uses and limitations. Intensive Care Med 49(4):465\u2013467","journal-title":"Intensive Care Med"},{"issue":"7","key":"956_CR26","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1164\/rccm.201908-1545CI","volume":"201","author":"JJ Marini","year":"2020","unstructured":"Marini JJ, Rocco PRM, Gattinoni L (2020) Static and dynamic contributors to ventilator-induced lung injury in clinical practice. Pressure, energy, and power. Am J Respir Crit Care Med 201(7):767\u2013774","journal-title":"Am J Respir Crit Care Med"},{"issue":"1","key":"956_CR27","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1186\/s13054-023-04406-9","volume":"27","author":"JJ Marini","year":"2023","unstructured":"Marini JJ, Thornton LT, Rocco PRM, Gattinoni L, Crooke PS (2023) Practical assessment of risk of VILI from ventilating power: a conceptual model. Crit Care 27(1):157","journal-title":"Crit Care"},{"issue":"29","key":"956_CR28","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000016531","volume":"98","author":"Y Xie","year":"2019","unstructured":"Xie Y, Wang Y, Liu K, Li X (2019) Correlation analysis between mechanical power, transforming growth factor-beta1, and connective tissue growth factor levels in acute respiratory distress syndrome patients and their clinical significance in pulmonary structural remodeling. Medicine (Baltimore) 98(29):e16531","journal-title":"Medicine (Baltimore)"},{"issue":"10","key":"956_CR29","doi-asserted-by":"publisher","first-page":"1184","DOI":"10.1177\/08850666211024139","volume":"36","author":"PD Wendel Garcia","year":"2021","unstructured":"Wendel Garcia PD, Hofmaenner DA, Brugger SD, Acevedo CT, Bartussek J, Camen G et al (2021) Closed-loop versus conventional mechanical ventilation in COVID-19 ARDS. J Intensive Care Med 36(10):1184\u20131193","journal-title":"J Intensive Care Med"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-026-00956-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-026-00956-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-026-00956-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:09:06Z","timestamp":1787022546000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40635-026-00956-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,18]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["956"],"URL":"https:\/\/doi.org\/10.1186\/s40635-026-00956-8","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,18]]},"assertion":[{"value":"21 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was approved by the institutional review board of the AMC (2020_317#B2021122) and the Cantonal Ethics Commission Zurich (Swissethics, 2023\u2013D0012). Written informed consent was obtained from legal representatives of all patients prior to inclusion and randomization.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"107"}}