{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:44:50Z","timestamp":1792788290924,"version":"4.5.0"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","id":[{"id":"https:\/\/ror.org\/00f7hpc57","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The endotracheal tube resistance dominates the total airway resistance in most intubated patients. Mucus deposition and biofilm formation can rapidly increase tube resistance and thereby contribute to serious ventilatory impairments, including dynamic hyperinflation, intrinsic PEEP build-up, added work of breathing, and patient-ventilator asynchrony. During controlled mechanical ventilation, an increased tube resistance can be inferred from the difference between peak and plateau pressure, but this approach fails during pressure-supported spontaneous breathing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We present a method that estimates the linear and nonlinear components of tube resistance from naturally occurring airway pressure and flow fluctuations at the airway opening, without a tracheal pressure sensor and without imposed forced oscillations. This is achieved by solving the equation of motion using band-pass filtered airway pressure and flow signals. Band-pass filtering isolates the relevant resistive and inertive pressure losses across the tube by removing slow contributions from muscle pressure and lung elastance as well as high-frequency noise.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Across different ventilation modes, ventilator settings, tube diameters, filters, and breathing patterns, the method recovers both linear and nonlinear tube resistance parameters with &lt;\u200910% error and &lt;\u20092% bias. The method can also track progressive tube obstruction on a breath-by-breath basis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Continuous estimation of the endotracheal tube resistance from naturally occurring, ventilator-induced airway pressure and flow fluctuations enables breath-by-breath detection of tube obstruction and provides the parameters required for automatic tube resistance compensation during spontaneous breathing. This approach may improve patient safety, reduce patient-ventilator asynchrony, and facilitate weaning.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40635-026-00982-6","type":"journal-article","created":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T09:45:32Z","timestamp":1790675132000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Continuous monitoring of endotracheal tube obstructions using naturally occurring pressure and flow oscillations"],"prefix":"10.1186","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1737-0465","authenticated-orcid":false,"given":"Ben","family":"Fabry","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Kuster","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland C. E.","family":"Francis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,29]]},"reference":[{"issue":"1","key":"982_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1164\/ajrccm\/140.1.10","volume":"140","author":"PE Wright","year":"1989","unstructured":"Wright PE, Marini JJ, Bernard GR (1989) In vitro versus in vivo comparison of endotracheal tube airflow resistance. Am Rev Respir Dis 140(1):10\u201316. https:\/\/doi.org\/10.1164\/ajrccm\/140.1.10","journal-title":"Am Rev Respir Dis"},{"issue":"1","key":"982_CR2","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1183\/09031936.95.08010114","volume":"8","author":"J Guttmann","year":"1995","unstructured":"Guttmann J, Eberhard L, Fabry B, Bertschmann W, Zeravik J, Adolph M, Eckart J, Wolff G (1995) Time constant\/volume relationship of passive expiration in mechanically ventilated ARDS patients. Eur Respir J 8(1):114\u2013120. https:\/\/doi.org\/10.1183\/09031936.95.08010114","journal-title":"Eur Respir J"},{"key":"982_CR3","doi-asserted-by":"crossref","unstructured":"Rohrer F (1915) Der Str\u00f6mungswiderstand in den menschlichen Atemwegen und der Einfluss der unregelm\u00e4ssigen Verzweigung des Bronchialsystems auf den Atmungsverlauf in verschiedenen Lungenbezirken. Pfl\u00fcger\u2019s Archiv f\u00fcr die gesamte Physiologie des Menschen und der Tiere. 162:225\u2013299","DOI":"10.1007\/BF01681259"},{"issue":"5","key":"982_CR4","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1007\/s001340050371","volume":"23","author":"B Fabry","year":"1997","unstructured":"Fabry B, Haberthur C, Zappe D, Guttmann J, Kuhlen R, Stocker R (1997) Breathing pattern and additional work of breathing in spontaneously breathing patients with different ventilatory demands during inspiratory pressure support and automatic tube compensation. Intensive Care Med 23(5):545\u2013552. https:\/\/doi.org\/10.1007\/s001340050371","journal-title":"Intensive Care Med"},{"issue":"5","key":"982_CR5","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1378\/chest.107.5.1387","volume":"107","author":"B Fabry","year":"1995","unstructured":"Fabry B, Guttmann J, Eberhard L, Bauer T, Haberthur C, Wolff G (1995) An analysis of desynchronization between the spontaneously breathing patient and ventilator during inspiratory pressure support. Chest 107(5):1387\u20131394. https:\/\/doi.org\/10.1378\/chest.107.5.1387","journal-title":"Chest"},{"issue":"4","key":"982_CR6","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1378\/chest.08-1938","volume":"136","author":"AM Wilson","year":"2009","unstructured":"Wilson AM, Gray DM, Thomas JG (2009) Increases in endotracheal tube resistance are unpredictable relative to duration of intubation. Chest 136(4):1006\u20131013. https:\/\/doi.org\/10.1378\/chest.08-1938","journal-title":"Chest"},{"key":"982_CR7","doi-asserted-by":"publisher","unstructured":"King GG, Bates J, Berger KI, Calverley P, de Melo PL, Dellaca RL, Farre R, Hall GL, Ioan I, Irvin CG et al (2020) Technical standards for respiratory oscillometry. Eur Respir J 55(2). https:\/\/doi.org\/10.1183\/13993003.00753-2019","DOI":"10.1183\/13993003.00753-2019"},{"issue":"3","key":"982_CR8","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1097\/00000542-199309000-00014","volume":"79","author":"J Guttmann","year":"1993","unstructured":"Guttmann J, Eberhard L, Fabry B, Bertschmann W, Wolff G (1993) Continuous calculation of intratracheal pressure in tracheally intubated patients. Anesthesiology 79(3):503\u2013513. https:\/\/doi.org\/10.1097\/00000542-199309000-00014","journal-title":"Anesthesiology"},{"issue":"1","key":"982_CR9","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1186\/s40635-025-00846-5","volume":"13","author":"B Fabry","year":"2025","unstructured":"Fabry B, Bonakdar N, Kuster C, Bartl J, Krischke F, Francis R (2025) Prediction and prevention of ventilation impairments during bronchoscopy. Intensive Care Med Exp 13(1):130. https:\/\/doi.org\/10.1186\/s40635-025-00846-5","journal-title":"Intensive Care Med Exp"},{"key":"982_CR10","unstructured":"Fabry B, Bonakdar N, Kuster C (2024) Ventilator and method for controlling a Ventilator. World Intellectual Property Organization. https:\/\/patentscope.wipo.int\/search\/en\/detail.jsf?docId=WO2024052339 WO2024052339A1"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-026-00982-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-026-00982-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-026-00982-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T09:45:34Z","timestamp":1790675134000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40635-026-00982-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,29]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["982"],"URL":"https:\/\/doi.org\/10.1186\/s40635-026-00982-6","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,29]]},"assertion":[{"value":"5 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study did not involve human participants, data, or identifiable images.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors have seen and approved the manuscript.","order":2,"name":"Ethics","label":"Author approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. This study did not involve human participants, data, or identifiable images.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"BF and CK are the inventors of a pending patent application (PCT\/EP2023\/074318; WO2024052339A1) related to the prototype ventilator described. BF is the inventor of a pending patent application (EP26160568.7) related to the method described. RF declares no competing interests.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"129"}}