{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:46:47Z","timestamp":1791827207170,"version":"4.3.4"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T00:00:00Z","timestamp":1791763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T00:00:00Z","timestamp":1791763200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["ICMx"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Change in the corrected flow time of the common carotid artery (ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      ) during a preload challenge (PC) is a surrogate for stroke volume change (SV\n                      <jats:sub>\u0394<\/jats:sub>\n                      ) to infer preload responsiveness (P\n                      <jats:sub>R<\/jats:sub>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This is a retrospective cohort study comprising patients with suspected sepsis in a large, publicly funded, academic emergency department; no patient health information is linked to the Doppler assessments. Carotid Doppler spectrograms from a wireless, wearable critical care Doppler ultrasound system are analyzed for ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      during a PC (either infusion of 300 mL of crystalloid over 3\u00a0min or a Trendelenburg maneuver). The primary objectives of this study are to describe the proportion of P\n                      <jats:sub>R<\/jats:sub>\n                      patients by previously described ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      thresholds (i.e., both 4 and 7 ms ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      ), describe time-to-peak (TTP) ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      , and evaluate the ability of baseline ccFT to detect ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      during PC, using both the equations of Wodey and Bazett. Comparisons of related outcomes were adjusted for multiple comparisons using the Holm procedure, baseline ccFT discrimination was quantified using area under the receiver operating characteristic curve, and TTP was estimated using patient-level bootstrap resampling. Threshold-agnostic ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      trajectories were additionally explored using unsupervised k-means clustering of patient-level temporal responses for both correction equations.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A PC was attempted in 4367 patients and an adequate ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      was collected from 4,128 patients (95%). In total, 982,937 Doppler cardiac cycles are included. The median ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      was 7.3 milliseconds (ms). 51.9% of patients had a ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      \u2265 7 ms, while 68.6% had a ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      \u2265 4 ms by the equation of Wodey. For Bazett, these fractions were 61.2% and 73.5%, respectively. For patients identified as P\n                      <jats:sub>R<\/jats:sub>\n                      based upon either a 4 ms or 7 ms ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      threshold, the time-to-peak ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      was 27.5\u00a0s for both equations. Baseline absolute ccFT did not discriminate P\n                      <jats:sub>R<\/jats:sub>\n                      from P\n                      <jats:sub>UR<\/jats:sub>\n                      patients under both correction formulae (AUROC 0.56\u20130.57).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      To our knowledge this is the largest reported dataset of ED patients with suspected sepsis receiving P\n                      <jats:sub>R<\/jats:sub>\n                      assessments by Doppler ultrasound, comprising nearly 1\u00a0million Doppler cardiac cycles obtained from over 4100 ED patients. Both 7 ms and 4 ms ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      thresholds described clinically-accepted rates of P\n                      <jats:sub>R<\/jats:sub>\n                      . The TTP was roughly 30\u00a0s into PC and baseline ccFT did not accurately detect ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      during PC. Finally, a hypothesis-generating analysis identified four distinct ccFT\n                      <jats:sub>\u0394<\/jats:sub>\n                      trajectories during PC which may represent unique preload response patterns during P\n                      <jats:sub>R<\/jats:sub>\n                      testing.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40635-026-00987-1","type":"journal-article","created":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:06:36Z","timestamp":1791824796000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The effect of preload on Doppler systolic time in a large emergency department cohort with suspected sepsis"],"prefix":"10.1186","volume":"14","author":[{"given":"Sarah","family":"Atwi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jared","family":"Nunnally","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristen","family":"Ugale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"So Mi","family":"Ko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaclyn","family":"Bond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimberly","family":"Boozer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raymond J.","family":"Bautista","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catalina","family":"Torres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Sedillo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Lachner-Piza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tracy","family":"Savery","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melissa","family":"Hebscher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph K.","family":"Eibl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3654-1146","authenticated-orcid":false,"given":"Jon-Emile S.","family":"Kenny","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Korbin","family":"Haycock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,12]]},"reference":[{"issue":"1","key":"987_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/s13089-025-00414-8","volume":"17","author":"J-ES Kenny","year":"2025","unstructured":"Kenny J-ES (2025) A framework for flow time measured by Doppler ultrasound. Ultrasound J 17(1):10","journal-title":"Ultrasound J"},{"issue":"4","key":"987_CR2","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.ultrasmedbio.2023.12.013","volume":"50","author":"J van Houte","year":"2024","unstructured":"van Houte J, Eerdekens R, Manning F, Te Pas M, Houterman S, Wijnbergen I, Montenij L, Tonino P, Bouwman A (2024) Is the Corrected Carotid Flow Time a Clinically Acceptable Surrogate Hemodynamic Parameter for the Left Ventricular Ejection Time? Ultrasound Med Biol 50(4):528\u2013535","journal-title":"Ultrasound Med Biol"},{"key":"987_CR3","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.1097\/CCM.0000000000003356","volume":"11","author":"I Barjaktarevic","year":"2018","unstructured":"Barjaktarevic I, Toppen WE, Hu S, Montoya EA, Ong S, Buhr R, David IJ, Wang T, Rezayat T, Chang SY (2018) Ultrasound Assessment of the Change in Carotid Corrected Flow Time in Fluid Responsiveness in Undifferentiated Shock. Crit Care Med 11:1040\u20131046","journal-title":"Crit Care Med"},{"key":"987_CR4","doi-asserted-by":"publisher","first-page":"100138","DOI":"10.1016\/j.chstcc.2025.100138","volume":"3","author":"JS Kenny","year":"2025","unstructured":"Kenny JS, Clarke G, Atwi S, Kerrebijn I, Savery T, Knott M, Munding CE, Elfarnawany M, Eibl AE, Eibl JK et al (2025) Carotid Artery Corrected Flow Time Measured by Wearable Doppler Ultrasound Detects Stroke Volume Change Measured by Trans-Esophageal Echocardiography Following Coronary Artery Bypass Grafting. CHEST Crit Care 3:100138","journal-title":"CHEST Crit Care"},{"key":"987_CR5","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1007\/s10877-025-01375-y","volume":"40","author":"Y Yang","year":"2025","unstructured":"Yang Y, Li M, Yang C, Shi Z, Wu H, Chen G, Chen L (2025) Comparison of the change in carotid corrected flow time and stroke volume variation for assessing volume responsiveness in general anesthesia patients: a prospective, observational study. J Clin Monit Comput 40:429\u2013438","journal-title":"J Clin Monit Comput"},{"issue":"9","key":"987_CR6","doi-asserted-by":"publisher","first-page":"e1303","DOI":"10.1097\/CCE.0000000000001303","volume":"7","author":"J Wang","year":"2025","unstructured":"Wang J, Blake LM, Orozco N, Fiorini K, McChesney C, Slessarev M, Prager R, Leligdowicz A, Sharif S, Lewis K et al (2025) Dynamic Measures of Fluid Responsiveness to Guide Resuscitation in Patients With Sepsis and Septic Shock: A Systematic Review and Meta-Analysis. Crit Care Explorations 7(9):e1303","journal-title":"Crit Care Explorations"},{"issue":"3","key":"987_CR7","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1007\/s10877-024-01255-x","volume":"39","author":"A Messina","year":"2025","unstructured":"Messina A, Grieco DL, Alicino V, Matronola GM, Brunati A, Antonelli M, Chew MS, Cecconi M (2025) Assessing fluid responsiveness by using functional hemodynamic tests in critically ill patients: a narrative review and a profile-based clinical guide. J Clin Monit Comput 39(3):481\u2013493","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"987_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-021-87116-y","volume":"11","author":"J-\u00c9 Kenny","year":"2021","unstructured":"Kenny J-\u00c9, Munding CE, Eibl JK, Eibl AM, Long BF, Boyes A, Yin J, Verrecchia P, Parrotta M, Gatzke R (2021) A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery. Sci Rep 11(1):1\u201311","journal-title":"Sci Rep"},{"issue":"1","key":"987_CR9","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s40560-023-00655-6","volume":"11","author":"JS Kenny","year":"2023","unstructured":"Kenny JS, Gibbs SO, Johnston D, Yang Z, Hofer LM, Elfarnawany M, Eibl JK, Johnson A, Buecker AJ, Lau VC et al (2023) The time cost of physiologically ineffective intravenous fluids in the emergency department: an observational pilot study employing wearable Doppler ultrasound. J Intensive Care 11(1):7","journal-title":"J Intensive Care"},{"key":"987_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fmedt.2021.676995","volume":"3","author":"J-\u00c9 Kenny","year":"2021","unstructured":"Kenny J-\u00c9, Barjaktarevic I, Mackenzie DC, Rola P, Haycock K, Eibl AM, Eibl JK (2021) Inferring the Frank\u2013Starling Curve From Simultaneous Venous and Arterial Doppler: Measurements From a Wireless, Wearable Ultrasound Patch. Front Med Technol 3:1\u20137","journal-title":"Front Med Technol"},{"issue":"1","key":"987_CR11","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13089-023-00330-9","volume":"15","author":"JS Kenny","year":"2023","unstructured":"Kenny JS, Gibbs SO, Eibl JK, Eibl AM, Yang Z, Johnston D, Munding CE, Elfarnawany M, Lau VC, Kemp BO et al (2023) Simultaneous venous-arterial Doppler during preload augmentation: illustrating the Doppler Starling curve. Ultrasound J 15(1):32","journal-title":"Ultrasound J"},{"issue":"7","key":"987_CR12","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1177\/08850666231224396","volume":"39","author":"JS Kenny","year":"2024","unstructured":"Kenny JS, Prager R, Rola P, Haycock K, Gibbs SO, Johnston DH, Horner C, Eibl JK, Lau VC, Kemp BO (2024) Simultaneous venous-arterial Doppler ultrasound during early fluid resuscitation to characterize a novel Doppler starling curve: a prospective observational pilot study. J Intensive Care Med 39(7):628\u2013635","journal-title":"J Intensive Care Med"},{"issue":"3","key":"987_CR13","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1002\/ajum.12388","volume":"27","author":"JS Kenny","year":"2024","unstructured":"Kenny JS, Rola P (2024) Optimising flow without congestion using the venous-arterial Doppler enhanced resuscitation framework. Australas J Ultrasound Med 27(3):193\u2013196","journal-title":"Australas J Ultrasound Med"},{"key":"987_CR14","doi-asserted-by":"publisher","first-page":"205031212412903","DOI":"10.1177\/20503121241290378","volume":"12","author":"J Nunnally","year":"2024","unstructured":"Nunnally J, Ko SM, Ugale K, Lowe T, Bond J, Kenny J-ES, Fargo RA, Haycock K (2024) A nursing-led sepsis response team guiding resuscitation with point-of-care ultrasound: A review and model for improving bundle compliance while individualizing sepsis care. SAGE Open Med 12:20503121241290378","journal-title":"SAGE Open Med"},{"issue":"1","key":"987_CR15","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/s42399-026-02318-7","volume":"8","author":"CS Kaufman","year":"2026","unstructured":"Kaufman CS, Wu D, Eibl JK, Kenny J-ES (2026) Ultrasonographic Measures of Safe and Fluid Effective Resuscitation (SaFER): Incorporating the VExUS and VTI into Protocolized Care. SN Compr Clin Med 8(1):73","journal-title":"SN Compr Clin Med"},{"issue":"4","key":"987_CR16","doi-asserted-by":"publisher","first-page":"S134","DOI":"10.1016\/j.annemergmed.2017.07.409","volume":"70","author":"N Selden","year":"2017","unstructured":"Selden N, Skaggs H, Lowe T, Haycock K, Dinh V (2017) 338 Assessing the Utility of Nursing-Performed Point-of-Care Ultrasound as a Guide to Fluid Resuscitation of Septic Patients in the Emergency Department. Ann Emerg Med 70(4):S134","journal-title":"Ann Emerg Med"},{"issue":"6","key":"987_CR17","first-page":"e40519","volume":"15","author":"S Kalam","year":"2023","unstructured":"Kalam S, Selden N, Haycock K, Lowe T, Skaggs H, Dinh VA (2023) Evaluating the Effect of Nursing-Performed Point-of-Care Ultrasound on Septic Emergency Department Patients. Cureus 15(6):e40519","journal-title":"Cureus"},{"issue":"1","key":"987_CR18","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3390\/medsci10010012","volume":"10","author":"J-ES Kenny","year":"2022","unstructured":"Kenny J-ES (2022) Assessing Fluid Intolerance with Doppler Ultrasonography: A Physiological Framework. Med Sci 10(1):12","journal-title":"Med Sci"},{"key":"987_CR19","doi-asserted-by":"publisher","first-page":"154070","DOI":"10.1016\/j.jcrc.2022.154070","volume":"71","author":"E Kattan","year":"2022","unstructured":"Kattan E, Castro R, Miralles-Aguiar F, Hern\u00e1ndez G, Rola P (2022) The emerging concept of fluid tolerance: A position paper. J Crit Care 71:154070","journal-title":"J Crit Care"},{"issue":"1","key":"987_CR20","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/SHK.0000000000002487","volume":"63","author":"J-ES Kenny","year":"2025","unstructured":"Kenny J-ES, CORRECTING THE CAROTID FLOW TIME WITH THE FORMULA OF BAZETT (2025) MIND THE UNITS. Shock 63(1):176\u2013177","journal-title":"Shock"},{"issue":"1","key":"987_CR21","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1186\/s13054-019-2545-z","volume":"23","author":"A Messina","year":"2019","unstructured":"Messina A, Dell\u2019Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, Saderi L, Sotgiu G, Antonelli M, Cecconi M (2019) Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care 23(1):264","journal-title":"Crit Care"},{"issue":"3","key":"987_CR22","first-page":"236","volume":"128","author":"R Barth\u00e9l\u00e9my","year":"2021","unstructured":"Barth\u00e9l\u00e9my R, Kindermans M, Delval P, Collet M, Gaugain S, Cecconi M, Mebazaa A, Chousterman BG (2021) Accuracy of cumulative volumes of fluid challenge to assess fluid responsiveness in critically ill patients with acute circulatory failure: a pharmacodynamic approach. Br J Anaesth 128(3):236\u2013243","journal-title":"Br J Anaesth"},{"issue":"12","key":"987_CR23","doi-asserted-by":"publisher","first-page":"799","DOI":"10.21037\/atm.2019.12.14","volume":"8","author":"A Minini","year":"2020","unstructured":"Minini A, Abraham P, Malbrain M (2020) Predicting fluid responsiveness with the passive leg raising test: don\u2019t be fooled by intra-abdominal hypertension! Ann Transl Med 8(12):799","journal-title":"Ann Transl Med"},{"issue":"7","key":"987_CR24","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1001\/jama.2019.0071","volume":"321","author":"G Hern\u00e1ndez","year":"2019","unstructured":"Hern\u00e1ndez G, Ospina-Tasc\u00f3n GA, Damiani LP, Estenssoro E, Dubin A, Hurtado J, Friedman G, Castro R, Alegr\u00eda L, Teboul J-L (2019) Effect of a resuscitation strategy targeting peripheral perfusion status vs serum lactate levels on 28-day mortality among patients with septic shock: the ANDROMEDA-SHOCK randomized clinical trial. JAMA 321(7):654\u2013664","journal-title":"JAMA"},{"issue":"1","key":"987_CR25","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s13054-020-2732-y","volume":"24","author":"E Kattan","year":"2020","unstructured":"Kattan E, Ospina-Tasc\u00f3n GA, Teboul J-L, Castro R, Cecconi M, Ferri G, Bakker J, Hern\u00e1ndez G, Investigators A-S (2020) Systematic assessment of fluid responsiveness during early septic shock resuscitation: secondary analysis of the ANDROMEDA-SHOCK trial. Crit Care 24(1):23","journal-title":"Crit Care"},{"issue":"22","key":"987_CR26","doi-asserted-by":"publisher","first-page":"1988","DOI":"10.1001\/jama.2025.20402","volume":"334","author":"P Reanimation","year":"2025","unstructured":"The ANDROMEDA-SHOCK-2 Investigators for the ANDROMEDA Research Network SSoA, Reanimation P, Therapy, Network LAIC (2025) Personalized Hemodynamic Resuscitation Targeting Capillary Refill Time in Early Septic Shock: The ANDROMEDA-SHOCK-2 Randomized Clinical Trial. JAMA 334(22):1988\u20131999","journal-title":"JAMA"},{"issue":"5","key":"987_CR27","doi-asserted-by":"publisher","first-page":"1402","DOI":"10.1097\/01.CCM.0000215453.11735.06","volume":"34","author":"X Monnet","year":"2006","unstructured":"Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul J-L (2006) Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 34(5):1402\u20131407","journal-title":"Crit Care Med"},{"issue":"6","key":"987_CR28","doi-asserted-by":"publisher","first-page":"e192","DOI":"10.1016\/j.bja.2023.09.016","volume":"131","author":"I Kerrebijn","year":"2023","unstructured":"Kerrebijn I, Atwi S, Horner C, Elfarnawany M, Eibl AM, Eibl JK, Taylor JL, Kim CH, Johnson BD, Kenny JS (2023) Correlation between changing carotid artery corrected flow time and ascending aortic Doppler flow velocity. Br J Anaesth 131(6):e192\u2013e195","journal-title":"Br J Anaesth"},{"issue":"3","key":"987_CR29","doi-asserted-by":"publisher","first-page":"183","DOI":"10.4097\/kja.22385","volume":"76","author":"D Singla","year":"2023","unstructured":"Singla D, Gupta B, Varshney P, Mangla M, Walikar BN, Jamir T (2023) Role of carotid corrected flow time and peak velocity variation in predicting fluid responsiveness: a systematic review and meta-analysis. Korean J Anesthesiol 76(3):183\u2013193","journal-title":"Korean J Anesthesiol"},{"issue":"3","key":"987_CR30","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1016\/j.bja.2017.12.047","volume":"121","author":"D-H Kim","year":"2018","unstructured":"Kim D-H, Shin S, Kim N, Choi T, Choi S, Choi Y (2018) Carotid ultrasound measurements for assessing fluid responsiveness in spontaneously breathing patients: corrected flow time and respirophasic variation in blood flow peak velocity. Br J Anaesth 121(3):541\u2013549","journal-title":"Br J Anaesth"},{"issue":"12","key":"987_CR31","doi-asserted-by":"publisher","first-page":"2676","DOI":"10.3390\/jcm10122676","volume":"10","author":"S Jung","year":"2021","unstructured":"Jung S, Kim J, Na S, Nam WS, Kim D-H (2021) Ability of Carotid Corrected Flow Time to Predict Fluid Responsiveness in Patients Mechanically Ventilated Using Low Tidal Volume after Surgery. J Clin Med 10(12):2676","journal-title":"J Clin Med"},{"issue":"6","key":"987_CR32","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1213\/ANE.0000000000006820","volume":"138","author":"AC Lipszyc","year":"2024","unstructured":"Lipszyc AC, Walker SCD, Beech AP, Wilding H, Akhlaghi H (2024) Predicting Fluid Responsiveness Using Carotid Ultrasound in Mechanically Ventilated Patients: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Anesth Analg 138(6):1174\u20131186","journal-title":"Anesth Analg"},{"issue":"1","key":"987_CR33","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1097\/SHK.0000000000001959","volume":"58","author":"H Wang","year":"2022","unstructured":"Wang H, Chen W, Cheng H, Liu C, Yao W, Ding F, Wang Y, Chen Y (2022) Value Of Corrected Flow Time In Common Carotid Artery In Predicting Volume Responsiveness Under Mechanical Ventilation. Shock 58(1):28\u201333","journal-title":"Shock"},{"issue":"4","key":"987_CR34","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1097\/CCM.0000000000002851","volume":"46","author":"SJ Beesley","year":"2018","unstructured":"Beesley SJ, Weber G, Sarge T, Nikravan S, Grissom CK, Lanspa MJ, Shahul S, Brown SM (2018) Septic Cardiomyopathy. Crit Care Med 46(4):625\u2013634","journal-title":"Crit Care Med"},{"issue":"2","key":"987_CR35","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1007\/s00134-025-07782-8","volume":"51","author":"A Messina","year":"2025","unstructured":"Messina A, Vieillard\u2013Baron A (2025) How we could use critical care echocardiography in the assessment of and management of cardiovascular phenotypes in septic shock: the good, the bad, and the ugly profiles. Intensive Care Med 51(2):397\u2013400","journal-title":"Intensive Care Med"},{"issue":"1","key":"987_CR36","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1002\/jcu.23838","volume":"53","author":"I Cheong","year":"2025","unstructured":"Cheong I, Merlo PM, Tamagnone FM (2025) Correlation between corrected carotid flow time and left ventricular outflow tract velocity-time integral using a novel technique. J Clin Ultrasound 53(1):97\u2013102","journal-title":"J Clin Ultrasound"},{"issue":"1","key":"987_CR37","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1186\/s13054-024-05171-z","volume":"28","author":"J-ES Kenny","year":"2024","unstructured":"Kenny J-ES (2024) Passive leg raising uncovers venous congestion: dynamic fluid intolerance and the Doppler Starling curve. Crit Care 28(1):388","journal-title":"Crit Care"},{"issue":"4","key":"987_CR38","doi-asserted-by":"publisher","first-page":"1069","DOI":"10.1007\/s10877-021-00736-7","volume":"36","author":"A Kimura","year":"2021","unstructured":"Kimura A, Suehiro K, Juri T, Tanaka K, Mori T (2021) Changes in corrected carotid flow time induced by recruitment maneuver predict fluid responsiveness in patients undergoing general anesthesia. J Clin Monit Comput 36(4):1069\u20131077","journal-title":"J Clin Monit Comput"},{"issue":"2","key":"987_CR39","doi-asserted-by":"publisher","first-page":"212","DOI":"10.24908\/pocus.v8i2.16545","volume":"8","author":"T Jelic","year":"2023","unstructured":"Jelic T, Chenkin J (2023) Carotid Flow Time Compared with Invasive Monitoring as a Predictor of Volume Responsiveness in ICU patients. Pocus j 8(2):212\u2013216","journal-title":"Pocus j"},{"issue":"2","key":"987_CR40","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.amjms.2017.09.006","volume":"355","author":"B Jalil","year":"2017","unstructured":"Jalil B, Thompson P, Cavallazzi R, Marik P, Mann J, El Kersh K, Guardiola J, Saad M (2017) Comparing Changes in Carotid Flow Time and Stroke Volume Induced by Passive Leg Raising. Am J Med Sci 355(2):168\u2013173","journal-title":"Am J Med Sci"},{"key":"987_CR41","doi-asserted-by":"crossref","unstructured":"Suehiro K (2026) Carotid flow time: a new surrogate for fluid responsiveness? J Anesth (online ahead of print)","DOI":"10.1007\/s00540-026-03713-z"},{"key":"987_CR42","doi-asserted-by":"publisher","first-page":"100036","DOI":"10.1016\/j.aicoj.2026.100036","volume":"16","author":"R Castro","year":"2026","unstructured":"Castro R, Kattan E, Melo P, Amthauer M, Hernandez G (2026) The time course of fluid responsiveness. Ann Intensiv Care 16:100036","journal-title":"Ann Intensiv Care"},{"issue":"20","key":"987_CR43","doi-asserted-by":"publisher","first-page":"2248","DOI":"10.1001\/jama.2011.1615","volume":"306","author":"AJ Walkey","year":"2011","unstructured":"Walkey AJ, Wiener RS, Ghobrial JM, Curtis LH, Benjamin EJ (2011) Incident Stroke and Mortality Associated With New-Onset Atrial Fibrillation in Patients Hospitalized With Severe Sepsis. JAMA 306(20):2248\u20132254","journal-title":"JAMA"}],"container-title":["Intensive Care Medicine Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-026-00987-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40635-026-00987-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40635-026-00987-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:06:38Z","timestamp":1791824798000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40635-026-00987-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,12]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["987"],"URL":"https:\/\/doi.org\/10.1186\/s40635-026-00987-1","relation":{},"ISSN":["2197-425X"],"issn-type":[{"value":"2197-425X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,12]]},"assertion":[{"value":"30 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol (Pro00085445) was approved by the Advarra Institutional Review Board on May 24th, 2026, with a determination of exemption from Investigational Device Exemption (IDE) regulations and a waiver of patient informed consent to analyze de-identified data.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol (Pro00085445) was approved by the Advarra Institutional Review Board on May 24th, 2026, with a determination of exemption from Investigational Device Exemption (IDE) regulations and a waiver of patient informed consent to analyze de-identified data.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"SA, DLP, TS, MH, JKE, JESK and work for Flosonics Medical, a start-up building the wireless, wearable critical care ultrasound system.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"135"}}