{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T22:04:29Z","timestamp":1778364269303,"version":"3.51.4"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T00:00:00Z","timestamp":1647388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T00:00:00Z","timestamp":1647388800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cancer Imaging"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>To compare image quality, lesion detection and patient comfort of 3T prostate MRI using a combined rigid two-channel phased-array endorectal coil and an external phased-array coil (ERC-PAC) compared to external PAC acquisition in the same patients.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Thirty three men (mean age 65.3y) with suspected (<jats:italic>n<\/jats:italic>\u2009=\u200915) or biopsy-proven prostate cancer (PCa, <jats:italic>n<\/jats:italic>\u2009=\u200918) were prospectively enrolled in this exploratory study. 3T\u00a0prostate MRI including T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) was performed using an ERC-PAC versus PAC alone, in random order. Image quality, lesion detection and characterization (biparametric PI-RADSv2.1) were evaluated by 2 independent observers. Estimated signal-to-noise ratio (eSNR) was measured in identified lesions and the peripheral zone (PZ). Patient comfort was assessed using a questionnaire. Data were compared between sequences and acquisitions. Inter\/intra-observer agreement for PI-RADS scores was evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Twenty four prostate lesions (22 PCa) were identified in 20\/33 men. Superior image quality was found for ERC-PAC compared to PAC for T2WI for one observer (Obs.1, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.03) and high b-value DWI for both observers (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). The sensitivity of PI-RADS for lesion detection for ERC-PAC and PAC acquisitions was 79.2 and 75% for Obs.1, and 79.1 and 66.7%, for Obs.2, without significant difference for each observer (McNemar <jats:italic>p<\/jats:italic>-values \u22650.08). Inter\u2212\/intra-observer agreement for PI-RADS scores was moderate-to-substantial (kappa\u2009=\u20090.52\u20130.84). Higher eSNR was observed for lesions and PZ for T2WI and PZ for DWI using ERC-PAC (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.013). Most patients (21\/33) reported discomfort at ERC insertion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Despite improved image quality and eSNR using the rigid ERC-PAC combination, no significant improvement in lesion detection was observed, therefore not supporting the routine use of ERC for prostate MRI.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40644-022-00453-7","type":"journal-article","created":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T10:05:55Z","timestamp":1647425155000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Prostate MRI using a rigid two-channel phased-array endorectal coil: comparison with phased array coil acquisition at 3\u2009T"],"prefix":"10.1186","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4713-6453","authenticated-orcid":false,"given":"Sara","family":"Lewis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aasrith","family":"Ganti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pamela","family":"Argiriadi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ally","family":"Rosen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefanie","family":"Hectors","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sahar","family":"Semaan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steve","family":"Peti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maxwell","family":"Segall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kezia","family":"George","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vaneela","family":"Jaikaran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Villa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Kestenbaum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas","family":"Voutsinas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Doucette","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashutosh","family":"Tewari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ardeshir R.","family":"Rastinehad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bachir","family":"Taouli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,3,16]]},"reference":[{"issue":"2","key":"453_CR1","doi-asserted-by":"publisher","first-page":"343","DOI":"10.2214\/AJR.13.11046","volume":"202","author":"M de Rooij","year":"2014","unstructured":"de Rooij M, Hamoen EH, Futterer JJ, Barentsz JO, Rovers MM. Accuracy of multiparametric MRI for prostate cancer detection: a meta-analysis. AJR Am J Roentgenol. 2014;202(2):343\u201351.","journal-title":"AJR Am J Roentgenol"},{"issue":"14","key":"453_CR2","doi-asserted-by":"publisher","first-page":"3705","DOI":"10.1158\/1078-0432.CCR-14-0044","volume":"20","author":"OF Donati","year":"2014","unstructured":"Donati OF, Afaq A, Vargas HA, Mazaheri Y, Zheng J, Moskowitz CS, et al. Prostate MRI: evaluating tumor volume and apparent diffusion coefficient as surrogate biomarkers for predicting tumor Gleason score. Clin Cancer Res. 2014;20(14):3705\u201311.","journal-title":"Clin Cancer Res"},{"issue":"2","key":"453_CR3","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jacr.2013.05.006","volume":"11","author":"JL Leake","year":"2014","unstructured":"Leake JL, Hardman R, Ojili V, Thompson I, Shanbhogue A, Hernandez J, et al. Prostate MRI: access to and current practice of prostate MRI in the United States. J Am Coll Radiol. 2014;11(2):156\u201360.","journal-title":"J Am Coll Radiol"},{"issue":"1","key":"453_CR4","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.eururo.2015.08.052","volume":"69","author":"JC Weinreb","year":"2016","unstructured":"Weinreb JC, Barentsz JO, Choyke PL, Cornud F, Haider MA, Macura KJ, et al. PI-RADS prostate imaging - reporting and data system: 2015, version 2. Eur Urol. 2016;69(1):16\u201340.","journal-title":"Eur Urol"},{"key":"453_CR5","doi-asserted-by":"crossref","unstructured":"Engels RRM, Israel B, Padhani AR, Barentsz JO. Multiparametric magnetic resonance imaging for the detection of clinically significant prostate cancer: what urologists need to know. part 1: acquisition. Eur Urol.\u00a02020;77(4):457\u201368.","DOI":"10.1016\/j.eururo.2019.09.021"},{"issue":"6","key":"453_CR6","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1002\/jmri.24317","volume":"39","author":"B Turkbey","year":"2014","unstructured":"Turkbey B, Merino MJ, Gallardo EC, Shah V, Aras O, Bernardo M, et al. Comparison of endorectal coil and nonendorectal coil T2W and diffusion-weighted MRI at 3 tesla for localizing prostate cancer: correlation with whole-mount histopathology. J Magn Reson Imaging. 2014;39(6):1443\u20138.","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"453_CR7","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1148\/radiol.2441060425","volume":"244","author":"SW Heijmink","year":"2007","unstructured":"Heijmink SW, Futterer JJ, Hambrock T, Takahashi S, Scheenen TW, Huisman HJ, et al. Prostate cancer: body-array versus endorectal coil MR imaging at 3 T--comparison of image quality, localization, and staging performance. Radiology. 2007;244(1):184\u201395.","journal-title":"Radiology"},{"issue":"11","key":"453_CR8","doi-asserted-by":"publisher","first-page":"2218","DOI":"10.1007\/s00261-016-0819-3","volume":"41","author":"BK Barth","year":"2016","unstructured":"Barth BK, Cornelius A, Nanz D, Eberli D, Donati OF. Comparison of image quality and patient discomfort in prostate MRI: pelvic phased array coil vs. endorectal coil. Abdom Radiol (NY). 2016;41(11):2218\u201326.","journal-title":"Abdom Radiol (NY)"},{"issue":"6","key":"453_CR9","doi-asserted-by":"publisher","first-page":"1075","DOI":"10.1016\/j.ejrad.2016.03.014","volume":"85","author":"AD Baur","year":"2016","unstructured":"Baur AD, Daqqaq T, Wagner M, Maxeiner A, Huppertz A, Renz D, et al. T2- and diffusion-weighted magnetic resonance imaging at 3T for the detection of prostate cancer with and without endorectal coil: an intraindividual comparison of image quality and diagnostic performance. Eur J Radiol. 2016;85(6):1075\u201384.","journal-title":"Eur J Radiol"},{"issue":"6","key":"453_CR10","doi-asserted-by":"publisher","first-page":"255 e7","DOI":"10.1016\/j.urolonc.2016.02.009","volume":"34","author":"DN Costa","year":"2016","unstructured":"Costa DN, Yuan Q, Xi Y, Rofsky NM, Lenkinski RE, Lotan Y, et al. Comparison of prostate cancer detection at 3-T MRI with and without an endorectal coil: a prospective, paired-patient study. Urol Oncol. 2016;34(6):255 e7\u2013e13.","journal-title":"Urol Oncol"},{"key":"453_CR11","doi-asserted-by":"publisher","first-page":"550","DOI":"10.3349\/ymj.2012.53.3.550","volume":"53","author":"BSKT Kim","year":"2012","unstructured":"Kim BSKT, Kwon TG, Yoo ES. Comparison of pelvic phased-Array versus Endorectal coil magnetic resonance imaging at 3 tesla for local staging of prostate Cancer. Yonsei Med J. 2012;53:550\u20136.","journal-title":"Yonsei Med J"},{"key":"453_CR12","doi-asserted-by":"crossref","unstructured":"Ullrich T, Kohli MD, Ohliger MA, Magudia K, Arora SS, Barrett T, et al. Quality comparison of 3 tesla multiparametric MRI of the prostate using a flexible surface receiver coil versus conventional surface coil plus endorectal coil setup. Abdom Radiol (NY). 2020;45(12):4260\u201370.","DOI":"10.1007\/s00261-020-02641-0"},{"issue":"1","key":"453_CR13","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1002\/mrm.25099","volume":"73","author":"M Rata","year":"2015","unstructured":"Rata M, Birlea V, Murillo A, Paquet C, Cotton F, Salomir R. Endoluminal MR-guided ultrasonic applicator embedding cylindrical phased-array transducers and opposed-solenoid detection coil. Magn Resonan Med. 2015;73(1):417\u201326.","journal-title":"Magn Resonan Med"},{"issue":"6","key":"453_CR14","doi-asserted-by":"publisher","first-page":"1279","DOI":"10.1002\/jmri.25099","volume":"43","author":"MA Erturk","year":"2016","unstructured":"Erturk MA, Tian J, Van de Moortele PF, Adriany G, Metzger GJ. Development and evaluation of a multichannel endorectal RF coil for prostate MRI at 7T in combination with an external surface array. J Magn Resonan Imaging. 2016;43(6):1279\u201387.","journal-title":"J Magn Resonan Imaging."},{"issue":"2","key":"453_CR15","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1148\/radiol.13130811","volume":"270","author":"MA Haider","year":"2014","unstructured":"Haider MA, Krieger A, Elliott C, Da Rosa MR, Milot L. Prostate imaging: evaluation of a reusable two-channel endorectal receiver coil for MR imaging at 1.5 T. Radiology. 2014;270(2):556\u201365.","journal-title":"Radiology"},{"issue":"2","key":"453_CR16","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.brachy.2017.09.014","volume":"17","author":"GV Martin","year":"2018","unstructured":"Martin GV, Kudchadker RJ, Bruno TL, Frank SJ, Wang J. Comparison of prostate distortion by inflatable and rigid endorectal MRI coils in permanent prostate brachytherapy imaging. Brachytherapy. 2018;17(2):298\u2013305.","journal-title":"Brachytherapy"},{"issue":"4","key":"453_CR17","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1007\/s11934-016-0589-z","volume":"17","author":"M Kongnyuy","year":"2016","unstructured":"Kongnyuy M, George AK, Rastinehad AR, Pinto PA. Magnetic resonance imaging-ultrasound fusion-guided prostate biopsy: review of technology, techniques, and outcomes. Curr Urol Rep. 2016;17(4):32.","journal-title":"Curr Urol Rep"},{"key":"453_CR18","unstructured":"MR Prostate Imaging Reporting and Data System version 2.0. http:\/\/www.acr.org\/Quality-Safety\/Resources\/PIRADS\/.2015."},{"issue":"6","key":"453_CR19","doi-asserted-by":"publisher","first-page":"1767","DOI":"10.1002\/jmri.25705","volume":"46","author":"I Corcuera-Solano","year":"2017","unstructured":"Corcuera-Solano I, Wagner M, Hectors S, Lewis S, Titelbaum N, Stemmer A, et al. DWI of the prostate: comparison of a faster diagonal acquisition to standard three-scan trace acquisition. J Magn Reson Imaging. 2017;46(6):1767\u201375.","journal-title":"J Magn Reson Imaging"},{"key":"453_CR20","doi-asserted-by":"publisher","unstructured":"Turkbey B, Rosenkrantz AB, Haider MA, et al. Prostate Imaging Reporting and Data\u00a0System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2. Eur Urol.\u00a02019;76(3):340\u201351. https:\/\/doi.org\/10.1016\/j.eururo.2019.02.033.","DOI":"10.1016\/j.eururo.2019.02.033"},{"issue":"3","key":"453_CR21","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1148\/radiol.2453062151","volume":"245","author":"JT Heverhagen","year":"2007","unstructured":"Heverhagen JT. Noise measurement and estimation in MR imaging experiments. Radiology. 2007;245(3):638\u20139.","journal-title":"Radiology"},{"issue":"10","key":"453_CR22","doi-asserted-by":"publisher","first-page":"e515","DOI":"10.1016\/j.ejrad.2013.04.041","volume":"82","author":"Y Mazaheri","year":"2013","unstructured":"Mazaheri Y, Vargas HA, Nyman G, Shukla-Dave A, Akin O, Hricak H. Diffusion-weighted MRI of the prostate at 3.0 T: comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI-the impact of SNR on ADC measurement. Eur J Radiol. 2013;82(10):e515\u201320.","journal-title":"Eur J Radiol"},{"key":"453_CR23","doi-asserted-by":"publisher","first-page":"40640","DOI":"10.1038\/srep40640","volume":"7","author":"J Gawlitza","year":"2017","unstructured":"Gawlitza J, Reiss-Zimmermann M, Thormer G, Schaudinn A, Linder N, Garnov N, et al. Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate. Sci Rep. 2017;7:40640.","journal-title":"Sci Rep"},{"issue":"2","key":"453_CR24","doi-asserted-by":"publisher","first-page":"369","DOI":"10.2214\/AJR.17.18946","volume":"211","author":"XK Niu","year":"2018","unstructured":"Niu XK, Chen XH, Chen ZF, Chen L, Li J, Peng T. Diagnostic performance of Biparametric MRI for detection of prostate Cancer: a systematic review and Meta-analysis. AJR Am J Roentgenol. 2018;211(2):369\u201378.","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"453_CR25","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1002\/jmri.1880060514","volume":"6","author":"NM deSouza","year":"1996","unstructured":"deSouza NM, Gilderdale DJ, Puni R, Coutts GA, Young IR. A solid reusable endorectal receiver coil for magnetic resonance imaging of the prostate: design, use, and comparison with an inflatable endorectal coil. J Magn Resonan Imaging. 1996;6(5):801\u20134.","journal-title":"J Magn Resonan Imaging"},{"issue":"2","key":"453_CR26","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1002\/jmri.24179","volume":"39","author":"DK Powell","year":"2014","unstructured":"Powell DK, Kodsi KL, Levin G, Yim A, Nicholson D, Kagen AC. Comparison of comfort and image quality with two endorectal coils in MRI of the prostate. J Magn Resonan Imaging. 2014;39(2):419\u201326.","journal-title":"J Magn Resonan Imaging"}],"container-title":["Cancer Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40644-022-00453-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40644-022-00453-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40644-022-00453-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T10:15:10Z","timestamp":1647425710000},"score":1,"resource":{"primary":{"URL":"https:\/\/cancerimagingjournal.biomedcentral.com\/articles\/10.1186\/s40644-022-00453-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,16]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["453"],"URL":"https:\/\/doi.org\/10.1186\/s40644-022-00453-7","relation":{},"ISSN":["1470-7330"],"issn-type":[{"value":"1470-7330","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,16]]},"assertion":[{"value":"6 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 March 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"IRB approval was obtained for this prospective study. Informed consent was obtained from each subject.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"AR has a research agreement with Phillips. None of the other authors has any relevant disclosure.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15"}}