{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T04:03:40Z","timestamp":1746763420071,"version":"3.40.5"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T00:00:00Z","timestamp":1746662400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T00:00:00Z","timestamp":1746662400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cancer Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>To evaluate the effectiveness of a simple positioning aid device in neck CT scans for the diagnosis of thyroid cancer, with a focus on its influence on image quality and diagnostic accuracy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A randomized controlled trial was conducted involving 180 patients with suspected thyroid cancer. Participants were randomly assigned to two groups: the device-assisted positioning group (Group A) and the traditional positioning group (Group B). A total of 147 patients who underwent enhanced neck CT scans and subsequent surgical pathological biopsies were included in the final analysis. Image quality and thyroid disease diagnoses were independently assessed by two experienced radiologists, with a unified consensus for the final conclusions. Objective imaging parameters and subjective ratings were used to evaluate image quality. Pathological findings served as the gold standard to compare the diagnostic accuracy of the two groups for thyroid malignancy, capsular invasion, and lymph node metastasis. Additionally, radiation doses in both groups were compared.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A total of 147 patients were included in the analysis, with 72 patients in Group A and 75 in Group B. The baseline characteristics of the two groups were similar (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). Group A demonstrated significantly superior image quality compared to Group B, with shorter length of artifacts (LA), lower proportion of affected thyroid (PA), and lower artifact index (AI). Subjective assessments also favored Group A, showing better ratings for regional artifacts and overall image quality. In terms of diagnostic accuracy, Group A outperformed Group B in detecting thyroid cancer (AUC: 0.852 vs. 0.676, <jats:italic>P<\/jats:italic>\u2009=\u20090.021). For the right thyroid lobe, Group A had significantly better diagnostic performance (AUC: 0.897 vs. 0.746, <jats:italic>P<\/jats:italic>\u2009=\u20090.016). Group A also showed superior performance in diagnosing capsular invasion (AUC: 0.861 vs. 0.721, <jats:italic>P<\/jats:italic>\u2009=\u20090.037), with similar results observed for both the left and right thyroid lobes. There was no significant difference between the groups in diagnosing lymph node metastasis. Furthermore, thyroid region radiation doses (CTDIvol and SSDE) were significantly lower in Group A compared to Group B.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The use of a positioning aid device significantly improves CT image quality, enhancing diagnostic accuracy for malignant thyroid lesions and capsular invasion, while also reducing radiation exposure.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40644-025-00878-w","type":"journal-article","created":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T12:11:28Z","timestamp":1746706288000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The impact of a simple positioning aid device on the diagnostic performance of thyroid cancer in CT scans: a randomized controlled trial"],"prefix":"10.1186","volume":"25","author":[{"given":"Wei-Hua","family":"Lin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui-Juan","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wen-Cong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qing-Wen","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rui-Gang","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fu-Rong","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong-Yi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zheng-Han","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hai-Tao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui-Huang","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui-Jun","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,5,8]]},"reference":[{"issue":"1","key":"878_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1089\/thy.2015.0020","volume":"26","author":"BR Haugen","year":"2016","unstructured":"Haugen BR, Alexander EK, Bible KC, et al. 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American thyroid association guidelines task force on thyroid nodules and differentiated thyroid Cancer. Thyroid. 2016;26(1):1\u2013133.","journal-title":"Thyroid"},{"issue":"1","key":"878_CR2","doi-asserted-by":"publisher","first-page":"25","DOI":"10.14366\/usg.15027","volume":"35","author":"G Russ","year":"2016","unstructured":"Russ G. Risk stratification of thyroid nodules on ultrasonography with the French TI-RADS: description and reflections. Ultrasonography. 2016;35(1):25\u201338.","journal-title":"Ultrasonography"},{"issue":"9","key":"878_CR3","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1001\/jama.2018.0898","volume":"319","author":"C Durante","year":"2018","unstructured":"Durante C, Grani G, Lamartina L, et al. The diagnosis and management of thyroid nodules: A review. JAMA. 2018;319(9):914\u201324.","journal-title":"JAMA"},{"issue":"1","key":"878_CR4","doi-asserted-by":"publisher","first-page":"154","DOI":"10.3174\/ajnr.A4967","volume":"38","author":"CH Suh","year":"2017","unstructured":"Suh CH, Baek JH, Choi YJ, Lee JH. Performance of CT in the preoperative diagnosis of cervical lymph node metastasis in patients with papillary thyroid cancer: A systematic review and Meta-Analysis. AJNR Am J Neuroradiol. 2017;38(1):154\u201361.","journal-title":"AJNR Am J Neuroradiol"},{"issue":"3","key":"878_CR5","doi-asserted-by":"publisher","first-page":"236","DOI":"10.3390\/diagnostics14030236","volume":"14","author":"O G\u0105siorowski","year":"2024","unstructured":"G\u0105siorowski O, Leszczy\u0144ski J, Kaszczewska J, et al. Comparison of Fine-Needle aspiration cytopathology with histopathological examination of the thyroid gland in patients undergoing elective thyroid surgery: do we still need Fine-Needle aspiration cytopathology? Diagnostics (Basel). 2024;14(3):236.","journal-title":"Diagnostics (Basel)"},{"issue":"1","key":"878_CR6","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12880-022-00809-2","volume":"22","author":"Y Tong","year":"2022","unstructured":"Tong Y, Zhang J, Wei Y, et al. Ultrasound-based radiomics analysis for preoperative prediction of central and lateral cervical lymph node metastasis in papillary thyroid carcinoma: a multi-institutional study. BMC Med Imaging. 2022;22(1):82.","journal-title":"BMC Med Imaging"},{"issue":"3","key":"878_CR7","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1089\/thy.2020.0944","volume":"31","author":"KC Bible","year":"2021","unstructured":"Bible KC, Kebebew E, Brierley J, et al. 2021 American thyroid association guidelines for management of patients with anaplastic thyroid Cancer. Thyroid. 2021;31(3):337\u201386.","journal-title":"Thyroid"},{"issue":"1","key":"878_CR8","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1186\/s12885-023-11721-5","volume":"23","author":"B Wei","year":"2023","unstructured":"Wei B, Yao J, Peng C, Zhao S, et al. Clinical features and imaging examination assessment of cervical lymph nodes for thyroid carcinoma. BMC Cancer. 2023;23(1):1225.","journal-title":"BMC Cancer"},{"key":"878_CR9","doi-asserted-by":"publisher","first-page":"1224191","DOI":"10.3389\/fendo.2023.1224191","volume":"14","author":"H Zhao","year":"2023","unstructured":"Zhao H, Zheng C, Zhang H, et al. Diagnosis of thyroid disease using deep convolutional neural network models applied to thyroid scintigraphy images: a multicenter study. Front Endocrinol (Lausanne). 2023;14:1224191.","journal-title":"Front Endocrinol (Lausanne)"},{"key":"878_CR10","doi-asserted-by":"crossref","unstructured":"Wu JH, Zeng W, Wu RG, et al. Comparison of ultrasonography and CT for determining the preoperative benign or malignant nature of thyroid nodules: diagnostic performance according to calcification. Technol Cancer Res Treat. 2020;19:1533033820948183.","DOI":"10.1177\/1533033820948183"},{"key":"878_CR11","doi-asserted-by":"publisher","first-page":"828259","DOI":"10.3389\/fonc.2022.828259","volume":"12","author":"H Xu","year":"2022","unstructured":"Xu H, Wang X, Guan C, et al. Value of Whole-Thyroid CT-Based radiomics in predicting benign and malignant thyroid nodules. Front Oncol. 2022;12:828259.","journal-title":"Front Oncol"},{"issue":"1","key":"878_CR12","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1148\/radiol.14140481","volume":"275","author":"X Liu","year":"2015","unstructured":"Liu X, Ouyang D, Li H, et al. Papillary thyroid cancer: dual-energy spectral CT quantitative parameters for preoperative diagnosis of metastasis to the cervical lymph nodes. Radiology. 2015;275(1):167\u201376.","journal-title":"Radiology"},{"issue":"8","key":"878_CR13","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1007\/s00330-006-0168-7","volume":"16","author":"S Wirth","year":"2006","unstructured":"Wirth S, Meindl T, Treitl M, et al. Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT. Eur Radiol. 2006;16(8):1757\u201362.","journal-title":"Eur Radiol"},{"issue":"2","key":"878_CR14","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.radi.2024.02.004","volume":"30","author":"Y Nishiyama","year":"2024","unstructured":"Nishiyama Y, Yabuuchi K, Nishiyama Y, et al. Crossed Raised arm position improves the flow of contrast medium in torso contrast-enhanced computed tomography. Radiography (Lond). 2024;30(2):681\u20137.","journal-title":"Radiography (Lond)"},{"issue":"6","key":"878_CR15","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/j.ejrad.2012.12.024","volume":"82","author":"ST Feng","year":"2013","unstructured":"Feng ST, Wang M, Gao Z, et al. The influence of upper limb position on the effect of a contrast agent in chest CT enhancement. Eur J Radiol. 2013;82(6):1023\u20137.","journal-title":"Eur J Radiol"},{"issue":"4","key":"878_CR16","doi-asserted-by":"publisher","first-page":"782","DOI":"10.3174\/ajnr.A5054","volume":"38","author":"JE Park","year":"2017","unstructured":"Park JE, Lee JH, Ryu KH, et al. Improved diagnostic accuracy using arterial phase CT for lateral cervical lymph node metastasis from papillary thyroid Cancer. AJNR Am J Neuroradiol. 2017;38(4):782\u20138.","journal-title":"AJNR Am J Neuroradiol"},{"issue":"3","key":"878_CR17","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1097\/RLI.0000000000000525","volume":"54","author":"B Martens","year":"2019","unstructured":"Martens B, Hendriks BMF, Eijsvoogel NG, et al. Individually body Weight-Adapted contrast media application in computed tomography imaging of the liver at 90 kVp. Invest Radiol. 2019;54(3):177\u201382.","journal-title":"Invest Radiol"},{"key":"878_CR18","unstructured":"Tian, Zhaorong, et al. Application of spectral CT virtual plain scan combined with multi-model iterative reconstruction algorithm in thyroid image quality and radiation dose [in Chinese]. Chin J Med Imaging. 2022;30(2):129\u201333."},{"issue":"6","key":"878_CR19","doi-asserted-by":"publisher","first-page":"2525","DOI":"10.1007\/s00330-017-5215-z","volume":"28","author":"SM Lee","year":"2018","unstructured":"Lee SM, Kim SH, Ahn SJ, et al. Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of KeV settings and its added value for Crohn\u2019s disease. Eur Radiol. 2018;28(6):2525\u201334.","journal-title":"Eur Radiol"},{"issue":"5","key":"878_CR20","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1530\/EJE-12-0936","volume":"168","author":"G Russ","year":"2013","unstructured":"Russ G, et al. Prospective evaluation of thyroid imaging reporting and data system on 4550 nodules with and without elastography. Eur J Endocrinol. 2013;168(5):649\u201355.","journal-title":"Eur J Endocrinol"},{"key":"878_CR21","doi-asserted-by":"crossref","unstructured":"Tessler FN, Middleton WD, Grant EG, et al. ACR thyroid imaging, reporting and data system (TI-RADS): white paper of the ACR TI-RADS committee. J Am Coll Radiol. 2017;14(5):587\u201395.","DOI":"10.1016\/j.jacr.2017.01.046"},{"key":"878_CR22","unstructured":"American Association of Physicists in Medicine (AAPM). AAPM Report no. 204: sizespecific dose estimates (SSDE) in pediatric and adult body CT examinations. AAPM website. www.aapm.org\/pubs\/reports\/RPT_204.pdf. Published 2011. Accessed October 30, 2018."},{"issue":"3","key":"878_CR23","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.nic.2017.04.004","volume":"27","author":"E Liao","year":"2017","unstructured":"Liao E, Srinivasan A. Applications of Dual-Energy computed tomography for artifact reduction in the head, neck, and spine. Neuroimaging Clin N Am. 2017;27(3):489\u201397.","journal-title":"Neuroimaging Clin N Am"},{"key":"878_CR24","doi-asserted-by":"crossref","unstructured":"Jin W, Ma Y, Han D, et al. Joint application of hybrid iterative reconstruction and adaptive filters on neck-and-shoulder CT imaging: a clinical evaluation. J Appl Clin Med Phys. 2022;23(12):e13797.","DOI":"10.1002\/acm2.13797"},{"issue":"2","key":"878_CR25","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.nic.2022.01.001","volume":"32","author":"EL Marshall","year":"2022","unstructured":"Marshall EL, Ginat DT, Sammet S. Computed tomography imaging artifacts in the head and neck region: pitfalls and solutions. Neuroimaging Clin N Am. 2022;32(2):271\u20137.","journal-title":"Neuroimaging Clin N Am"},{"issue":"1","key":"878_CR26","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.ejrad.2015.11.008","volume":"85","author":"YJ Choi","year":"2016","unstructured":"Choi YJ, Lee JH, Cho WY, et al. Effect of an arm traction device on image quality and radiation exposure during neck computed tomography. Eur J Radiol. 2016;85(1):68\u201372.","journal-title":"Eur J Radiol"},{"issue":"29","key":"878_CR27","doi-asserted-by":"publisher","first-page":"e26633","DOI":"10.1097\/MD.0000000000026633","volume":"100","author":"JH Park","year":"2021","unstructured":"Park JH, Lee HJ, Lee SH, et al. Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial. Med (Baltim). 2021;100(29):e26633.","journal-title":"Med (Baltim)"},{"issue":"7","key":"878_CR28","doi-asserted-by":"publisher","first-page":"E179","DOI":"10.1097\/01.brs.0000157475.47514.75","volume":"30","author":"N Morishima","year":"2005","unstructured":"Morishima N, Ohota K, Miura Y. The influences of Halo-vest fixation and cervical hyperextension on swallowing in healthy volunteers. Spine (Phila Pa 1976). 2005;30(7):E179\u201382.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"878_CR29","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/1916-0216-43-9","volume":"43","author":"LA Badenduck","year":"2014","unstructured":"Badenduck LA, Matthews TW, McDonough A, et al. Fiber-optic endoscopic evaluation of swallowing to assess swallowing outcomes as a function of head position in a normal population. J Otolaryngol Head Neck Surg. 2014;43(1):9.","journal-title":"J Otolaryngol Head Neck Surg"},{"issue":"1","key":"878_CR30","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1186\/s12903-022-02329-5","volume":"22","author":"Y Ihara","year":"2022","unstructured":"Ihara Y, Kato H, Tashimo Y, et al. Changes in oral function, swallowing function, and quality of life in patients with head and neck cancer: a prospective cohort study. BMC Oral Health. 2022;22(1):293.","journal-title":"BMC Oral Health"}],"container-title":["Cancer Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40644-025-00878-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40644-025-00878-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40644-025-00878-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T12:11:30Z","timestamp":1746706290000},"score":1,"resource":{"primary":{"URL":"https:\/\/cancerimagingjournal.biomedcentral.com\/articles\/10.1186\/s40644-025-00878-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,8]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["878"],"URL":"https:\/\/doi.org\/10.1186\/s40644-025-00878-w","relation":{},"ISSN":["1470-7330"],"issn-type":[{"value":"1470-7330","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,8]]},"assertion":[{"value":"3 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The present study was approved by the ethics committee of Zhangzhou Affiliated Hospital of Fujian Medical University, and adhered to the tenets of the Declaration of Helsinki. Informed consent to participate was obtained from all of the participants in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"60"}}