{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T06:00:19Z","timestamp":1777010419820,"version":"3.51.4"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,2,13]],"date-time":"2016-02-13T00:00:00Z","timestamp":1455321600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["SA 669\/9-1"],"award-info":[{"award-number":["SA 669\/9-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1186\/s40658-016-0139-2","type":"journal-article","created":{"date-parts":[[2016,2,12]],"date-time":"2016-02-12T20:46:19Z","timestamp":1455309979000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Fully automated calculation of image-derived input function in simultaneous PET\/MRI in a sheep model"],"prefix":"10.1186","volume":"3","author":[{"given":"Thies H.","family":"Jochimsen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vilia","family":"Zeisig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica","family":"Schulz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Werner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marianne","family":"Patt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00f6rg","family":"Patt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antje Y.","family":"Dreyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes","family":"Boltze","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henryk","family":"Barthel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osama","family":"Sabri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Sattler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,2,13]]},"reference":[{"key":"139_CR1","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/00004647-199807000-00002","volume":"18","author":"K Chen","year":"1998","unstructured":"Chen K, Bandy D, Reiman E, Huang SC, Lawson M, Feng D, et al.Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography 18F-fluoro-2-deoxyglucose, the patlak method, and an image-derived input function. J Cereb Blood Flow Metab. 1998; 18:716\u201323.","journal-title":"J Cereb Blood Flow Metab"},{"key":"139_CR2","first-page":"1666","volume":"40","author":"LM Wahl","year":"1999","unstructured":"Wahl LM, Asselin MC, Nahmias C. Regions of interest in the venous sinuses as input functions for quantitative PET. J Nucl Med. 1999; 40:1666\u201375.","journal-title":"J Nucl Med"},{"key":"139_CR3","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/S0303-2647(03)00112-6","volume":"71","author":"H Guo","year":"2003","unstructured":"Guo H, Renauta R, Chenb K, Reiman E. Clustering huge data sets for parametric PET imaging. BioSystems. 2003; 71:81\u201392.","journal-title":"BioSystems"},{"key":"139_CR4","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1007\/s00259-003-1412-x","volume":"31","author":"YH Fang","year":"2004","unstructured":"Fang YH, Kao T, Liu RS, Wu LC. Estimating the input function non-invasively for FDG-PET quantification with multiple linear regression analysis: simulation and verification with in vivo data. Eur J Nucl Med Mol Imag. 2004; 31:692\u2013702.","journal-title":"Eur J Nucl Med Mol Imag"},{"key":"139_CR5","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.neuroimage.2003.09.058","volume":"21","author":"M Liptrot","year":"2004","unstructured":"Liptrot M, Adams KH, Martiny L, Pinborg LH, Lonsdale MN, Olsen NV, et al.Cluster analysis in kinetic modelling of the brain: a noninvasive alternative to arterial sampling. NeuroImage. 2004; 21:483\u201393.","journal-title":"NeuroImage"},{"key":"139_CR6","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1109\/TBME.2004.840193","volume":"52","author":"M Naganawa","year":"2005","unstructured":"Naganawa M, Kimura Y, Ishii K, Oda K, Ishiwata K, Matani A. Extraction of a plasma time-activity curve from dynamic brain PET images based on independent component analysis. IEEE Trans Biomed Engin. 2005; 52:201\u201310.","journal-title":"IEEE Trans Biomed Engin"},{"key":"139_CR7","doi-asserted-by":"crossref","first-page":"606","DOI":"10.2967\/jnumed.107.047613","volume":"49","author":"Y-HD Fang","year":"2008","unstructured":"Fang Y-HD, Muzic Jr. RF. Spillover and partial-volume correction for image-derived input functions for small-animal 18F-FDG PET studies. J Nucl Med. 2008; 49:606\u201314.","journal-title":"J Nucl Med"},{"key":"139_CR8","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.neuroimage.2007.10.022","volume":"39","author":"JEM Mourik","year":"2008","unstructured":"Mourik JEM, Lubberink M, Klumpers UM, Comans EF, Lammertsma AA, Boellaard R. Partial volume corrected image derived input functions for dynamic PET brain studies: methodology and validation for 11C-flumazenil. NeuroImage. 2008; 39:1041\u201350.","journal-title":"NeuroImage"},{"key":"139_CR9","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1007\/s11307-009-0273-5","volume":"12","author":"Y Su","year":"2010","unstructured":"Su Y, Shoghi KI. Single-input-dual-output modeling of image-based input function estimation. Mol Imag Biol. 2010; 12:286\u201394.","journal-title":"Mol Imag Biol"},{"key":"139_CR10","doi-asserted-by":"crossref","first-page":"89101","DOI":"10.1371\/journal.pone.0089101","volume":"9","author":"CH Lyoo","year":"2014","unstructured":"Lyoo CH, Zanotti-Fregonara P, Zoghbi SS, Liow JS, Xu R, Pike VW, et al.Image-derived input function derived from a supervised clustering algorithm: methodology and validation in a clinical protocol using [11C](R)-rolipram. PLoS ONE. 2014; 9:89101.","journal-title":"PLoS ONE"},{"key":"139_CR11","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/MNM.0000000000000231","volume":"36","author":"U Simon\u010di\u010d","year":"2015","unstructured":"Simon\u010di\u010d U, Zanotti-Fregonara P. Image-derived input function with factor analysis and a-priori information. Nucl Med Comm. 2015; 36:187\u201393.","journal-title":"Nucl Med Comm"},{"key":"139_CR12","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1097\/00004728-199711000-00012","volume":"21","author":"JE Litton","year":"1997","unstructured":"Litton JE. Input function in PET brain studies using MR-defined arteries. J Comp Asst Tomogr. 1997; 21:907\u20139.","journal-title":"J Comp Asst Tomogr"},{"key":"139_CR13","doi-asserted-by":"crossref","first-page":"1903","DOI":"10.1088\/0031-9155\/58\/6\/1903","volume":"58","author":"EK Fung","year":"2013","unstructured":"Fung EK, Carson RE. Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines. Phys Med Biol. 2013; 58:1903\u201323.","journal-title":"Phys Med Biol"},{"key":"139_CR14","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.nima.2012.08.030","volume":"702","author":"N da Silva","year":"2013","unstructured":"da Silva N, Herzog H, Weirich C, Tellmann L, Kops ER, Hautzel H, et al.Image-derived input function obtained in a 3TMR-brainPET. Nucl Instr Meth Phys Res A. 2013; 702:22\u20135.","journal-title":"Nucl Instr Meth Phys Res A"},{"key":"139_CR15","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1038\/jcbfm.2012.143","volume":"33","author":"Y Su","year":"2013","unstructured":"Su Y, Arbelaez AM, Benzinger TLS, Snyder AZ, Vlassenko AG, Mintunand MA, et al.Noninvasive estimation of the arterial input function in positron emission tomography imaging of cerebral blood flow. J Cereb Blood Flow Metab. 2013; 33:115\u201321.","journal-title":"J Cereb Blood Flow Metab"},{"key":"139_CR16","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1007\/s00259-010-1443-z","volume":"37","author":"E Croteau","year":"2010","unstructured":"Croteau E, Lavall\u00e9e E, Labbe SM, Hubert L, Pifferi F, Rousseau JA, et al.Image-derived input function in dynamic human PET\/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain. Eur J Nucl Med Mol Imag. 2010; 37:1539\u201350.","journal-title":"Eur J Nucl Med Mol Imag"},{"key":"139_CR17","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.jmr.2004.05.021","volume":"170","author":"TH Jochimsen","year":"2004","unstructured":"Jochimsen TH, von Mengershausen M. ODIN\u2014object-oriented development interface for NMR. J Magn Reson. 2004; 170:67\u201378.","journal-title":"J Magn Reson"},{"key":"139_CR18","doi-asserted-by":"crossref","first-page":"1951","DOI":"10.1038\/jcbfm.2008.89","volume":"28","author":"J Boltze","year":"2008","unstructured":"Boltze J, F\u00f6rschler A, Nitzsche B, Waldmin D, Hoffmann A, Boltze CM, et al.Permanent middle cerebral artery occlusion in sheep: a novel large animal model of focal cerebral ischemia. J Cereb Blood Flow Metab. 2008; 28:1951\u201364.","journal-title":"J Cereb Blood Flow Metab"},{"key":"139_CR19","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1038\/jcbfm.2015.158","volume":"35","author":"P Werner","year":"2015","unstructured":"Werner P, Saur D, Zeisig V, Ettrich B, Patt M, Sattler B, et al.Simultaneous PET\/MRI in stroke: a case series. J Cereb Blood Flow Metab. 2015; 35:1421\u20135.","journal-title":"J Cereb Blood Flow Metab"},{"key":"139_CR20","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1109\/10.918601","volume":"48","author":"C Toumoulin","year":"2001","unstructured":"Toumoulin C, Boldak C, Dillenseger JL, Coatrieux JL, Rolland Y. Fast detection and characterization of vessels in very large data sets using geometrical moments. IEEE Trans Biomed Engin. 2001; 48:604\u20136.","journal-title":"IEEE Trans Biomed Engin"},{"key":"139_CR21","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s11548-006-0005-0","volume":"1","author":"M Hern\u00e1ndez Hoyos","year":"2006","unstructured":"Hern\u00e1ndez Hoyos M, Or\u0142owski P, Piatkowska-Janko E, Bogorodzki P, Orkisz M. Vascular centerline extraction in 3D MR angiograms for phase contrast MRI blood flow measurement. Int J Comp Asst Radiol Surg. 2006; 1:51\u201361.","journal-title":"Int J Comp Asst Radiol Surg"},{"key":"139_CR22","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1007\/s10334-012-0347-2","volume":"26","author":"B Sattler","year":"2013","unstructured":"Sattler B, Jochimsen T, Barthel H, Sommerfeld K, Stumpp P, Hoffmann KT, et al.Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET\/MR-imaging system in an integrated research and clinical setting. Magn Reson Mat Phys Biol Med. 2013; 26:159\u201371.","journal-title":"Magn Reson Mat Phys Biol Med"},{"key":"139_CR23","doi-asserted-by":"crossref","first-page":"3217","DOI":"10.1088\/0031-9155\/53\/12\/010","volume":"53","author":"FHP van Velden","year":"2008","unstructured":"van Velden FHP, Kloet RW, van Berckel BNM, Wolfensberger SPA, Lammertsma AA, Boellaard R. Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for high-resolution research tomograph studies: effects of randoms estimation methods. Phys Med Biol. 2008; 53:3217\u201330.","journal-title":"Phys Med Biol"},{"key":"139_CR24","first-page":"904","volume":"39","author":"OG Rousset","year":"1998","unstructured":"Rousset OG, Ma Y, Evans AC. Correction for partial volume effects in PET: principle and validation. J Nucl Med. 1998; 39:904\u201311.","journal-title":"J Nucl Med"},{"key":"139_CR25","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1038\/jcbfm.1984.4","volume":"4","author":"NM Alpert","year":"1984","unstructured":"Alpert NM, Eriksson L, Chang JY, Bergstrom M, Litton JE, Correia JA, et al.Strategy for the measurement of regional cerebral blood flow using short-lived tracers and emission tomography. J Cereb Blood Flow Metab. 1984; 4:28\u201334.","journal-title":"J Cereb Blood Flow Metab"},{"key":"139_CR26","first-page":"1069","volume":"30","author":"E Meyer","year":"1989","unstructured":"Meyer E. Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H2-15O autoradiographic method and dynamic PET. J Nucl Med. 1989; 30:1069\u201378.","journal-title":"J Nucl Med"},{"key":"139_CR27","first-page":"130","volume":"1496","author":"AF Frangi","year":"1998","unstructured":"Frangi AF, Niessen WJ, Vincken KL, Viergever MA. Multiscale vessel enhancement filtering. Proc Med Imag Comp Comp Asst Interv (MICCAI). 1998; 1496:130\u20137.","journal-title":"Proc Med Imag Comp Comp Asst Interv (MICCAI)"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-016-0139-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s40658-016-0139-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-016-0139-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,3,26]],"date-time":"2019-03-26T12:08:07Z","timestamp":1553602087000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.ejnmmiphys.com\/content\/3\/1\/2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,13]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["139"],"URL":"https:\/\/doi.org\/10.1186\/s40658-016-0139-2","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,2,13]]},"article-number":"2"}}