{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T10:17:55Z","timestamp":1785838675103,"version":"3.56.0"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,14]],"date-time":"2022-09-14T00:00:00Z","timestamp":1663113600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,9,14]],"date-time":"2022-09-14T00:00:00Z","timestamp":1663113600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The total-body positron emission tomography (PET) scanner provides an unprecedented opportunity to scan the whole body simultaneously, thanks to its long axial field of view and ultrahigh temporal resolution. To fully utilize this potential in clinical settings, a dynamic scan would be necessary to obtain the desired kinetic information from scan data. However, in a long dynamic acquisition, patient movement can degrade image quality and quantification accuracy.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this work, we demonstrated a motion correction framework and  its importance in dynamic total-body FDG PET imaging. Dynamic FDG scans from 12 subjects acquired on a uEXPLORER PET\/CT were included. In these subjects, 7 are healthy subjects and 5 are those with tumors in the thorax and abdomen. All scans were contaminated by motion to some degree, and for each the list-mode data were reconstructed into 1-min frames. The dynamic frames were aligned to a reference position by sequentially registering each frame to its previous neighboring frame. We parametrized the motion fields in-between frames as diffeomorphism, which can map the shape change of the object smoothly and continuously in time and space. Diffeomorphic representations of motion fields were derived by registering neighboring frames using large deformation diffeomorphic metric matching. When all pairwise registrations were completed, the motion field at each frame was obtained by concatenating the successive motion fields and transforming that frame into the reference position. The proposed correction method was labeled SyN-seq. The method that was performed similarly, but aligned each frame to a designated middle frame, was labeled as SyN-mid. Instead of SyN, the method that performed the sequential affine registration was labeled as Aff-seq. The original uncorrected images were labeled as NMC. Qualitative and quantitative analyses were performed to compare the performance of the proposed method with that of other correction methods and uncorrected images.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The results indicated that visual improvement was achieved after correction of the SUV images for the motion present period, especially in the brain and abdomen. For subjects with tumors, the average improvement in tumor SUVmean was 5.35\u2009\u00b1\u20094.92% (<jats:italic>P<\/jats:italic>\u2009=\u20090.047), with a maximum improvement of 12.89%. An overall quality improvement in quantitative K<jats:sub>i<\/jats:sub> images was also observed after correction; however, such improvement was less obvious in K<jats:sub>1<\/jats:sub> images. Sampled time\u2013activity curves in the cerebral and kidney cortex were less affected by the motion after applying the proposed correction. Mutual information and dice coefficient relative to the reference also demonstrated that SyN-seq improved the alignment between frames over non-corrected images (<jats:italic>P<\/jats:italic>\u2009=\u20090.003 and <jats:italic>P<\/jats:italic>\u2009=\u20090.011). Moreover, the proposed correction successfully reduced the inter-subject variability in K<jats:sub>i<\/jats:sub> quantifications (11.8% lower in sampled organs). Subjective assessment by experienced radiologists demonstrated consistent results for both SUV images and K<jats:sub>i<\/jats:sub> images.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>To conclude, motion correction is important for image quality in dynamic total-body PET imaging. We demonstrated a correction framework that can effectively reduce the effect of random body movements on dynamic images and their associated quantification. The proposed correction framework can potentially benefit applications that require total-body assessment, such as imaging the brain-gut axis and systemic diseases.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40658-022-00493-9","type":"journal-article","created":{"date-parts":[[2022,9,14]],"date-time":"2022-09-14T19:03:43Z","timestamp":1663182223000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Motion correction and its impact on quantification in dynamic total-body 18F-fluorodeoxyglucose PET"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6734-6837","authenticated-orcid":false,"given":"Tao","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaping","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangfang","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nan","family":"Meng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongzhao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaochen","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenguo","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Debin","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaojie","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhanli","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hairong","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongfeng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meiyun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,9,14]]},"reference":[{"key":"493_CR1","doi-asserted-by":"publisher","first-page":"06RM01","DOI":"10.1088\/1361-6560\/abd4f7","volume":"66","author":"SR Meikle","year":"2021","unstructured":"Meikle SR, Sossi V, Roncali E, et al. Quantitative PET in the 2020s: a roadmap. Phys Med Biol. 2021;66:06RM01.","journal-title":"Phys Med Biol"},{"key":"493_CR2","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.ejmp.2018.08.006","volume":"53","author":"FA Kotasidis","year":"2018","unstructured":"Kotasidis FA, Angelis GI, Anton-Rodriguez JM, Zaidi H. Robustness of post-reconstruction and direct kinetic parameter estimates under rigid head motion in dynamic brain PET imaging. Phys Medica. 2018;53:40\u201355.","journal-title":"Phys Medica"},{"key":"493_CR3","first-page":"1059","volume":"46","author":"H Herzog","year":"2005","unstructured":"Herzog H, Tellmann L, Fulton R, Stangier I, Kops ER, Bente K, Boy C, Hurlemann R, Pietrzyk U. Motion artifact reduction on parametric PET images of neuroreceptor binding. J Nucl Med. 2005;46:1059\u201365.","journal-title":"J Nucl Med"},{"key":"493_CR4","doi-asserted-by":"publisher","first-page":"210","DOI":"10.2967\/jnumed.109.063701","volume":"51","author":"M Wardak","year":"2010","unstructured":"Wardak M, Wong K-P, Shao W, Dahlbom M, Kepe V, Satyamurthy N, Small GW, Barrio JR, Huang S-C. Movement correction method for human brain PET images: application to quantitative analysis of dynamic 18F-FDDNP scans. J Nucl Med. 2010;51:210\u20138.","journal-title":"J Nucl Med"},{"key":"493_CR5","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.1073\/pnas.1917379117","volume":"117","author":"X Zhang","year":"2020","unstructured":"Zhang X, Cherry SR, Xie Z, Shi H, Badawi RD, Qi J. Subsecond total-body imaging using ultrasensitive positron emission tomography. Proc Natl Acad Sci U S A. 2020;117:2265\u20137.","journal-title":"Proc Natl Acad Sci U S A"},{"key":"493_CR6","doi-asserted-by":"publisher","first-page":"861","DOI":"10.2967\/jnumed.120.250597","volume":"62","author":"BA Spencer","year":"2021","unstructured":"Spencer BA, Berg E, Schmall JP, et al. Performance evaluation of the uEXPLORER total-body PET\/CT scanner based on NEMA NU 2\u20132018 with additional tests to characterize PET scanners with a long axial field of view. J Nucl Med. 2021;62:861\u201370.","journal-title":"J Nucl Med"},{"key":"493_CR7","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1007\/s00259-020-05007-2","volume":"48","author":"AH Dias","year":"2021","unstructured":"Dias AH, Pedersen MF, Danielsen H, Munk OL, Gormsen LC. Clinical feasibility and impact of fully automated multiparametric PET imaging using direct Patlak reconstruction: evaluation of 103 dynamic whole-body 18F-FDG PET\/CT scans. Eur J Nucl Med Mol Imaging. 2021;48:837\u201350.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"493_CR8","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1016\/j.cpet.2021.06.009","volume":"16","author":"Y Wang","year":"2021","unstructured":"Wang Y, Li E, Cherry SR, Wang G. Total-body PET kinetic modeling and potential opportunities using deep learning. PET Clin. 2021;16:613\u201325.","journal-title":"PET Clin"},{"issue":"8","key":"493_CR9","first-page":"2498","volume":"49","author":"G Liu","year":"2021","unstructured":"Liu G, Yu H, Shi D, Hu P, Hu Y, Tan H, Zhang Y, Yin H, Shi H. Short-time total-body dynamic PET imaging performance in quantifying the kinetic metrics of 18F-FDG in healthy volunteers. Eur J Nucl Med Mol Imaging. 2021;49(8):2498.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"4","key":"493_CR10","doi-asserted-by":"publisher","first-page":"622","DOI":"10.2967\/jnumed.120.261651","volume":"63","author":"Y Wu","year":"2021","unstructured":"Wu Y, Feng T, Zhao Y, Xu T, Fu F, Huang Z, Meng N, Li H, Shao F, Wang M. Whole-body parametric imaging of FDG PET using uEXPLORER with reduced scan time. J Nucl Med. 2021;63(4):622.","journal-title":"J Nucl Med"},{"key":"493_CR11","doi-asserted-by":"publisher","first-page":"18TR02","DOI":"10.1088\/1361-6560\/ac093b","volume":"66","author":"AZ Kyme","year":"2021","unstructured":"Kyme AZ, Fulton RR. Motion estimation and correction in SPECT. PET and CT Phys Med Biol. 2021;66:18TR02.","journal-title":"PET and CT. Phys Med Biol."},{"key":"493_CR12","doi-asserted-by":"publisher","first-page":"846","DOI":"10.2967\/jnumed.115.171728","volume":"58","author":"C Kolbitsch","year":"2017","unstructured":"Kolbitsch C, Davies-Venn C, Schaeffter T, Marsden P, Kellman P, Evers R, Peressutti D, Bluemke DA, Ahlman MA, Hansen M. Cardiac and respiratory motion correction for simultaneous cardiac PET\/MR. J Nucl Med. 2017;58:846\u201352.","journal-title":"J Nucl Med"},{"key":"493_CR13","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaea97","volume":"63","author":"PM Robson","year":"2018","unstructured":"Robson PM, Trivieri MG, Karakatsanis NA, Padilla M, Abgral R, Dweck MR, Kovacic JC, Fayad ZA. Correction of respiratory and cardiac motion in cardiac PET\/MR using MR-based motion modeling. Phys Med Biol. 2018;63: 225011.","journal-title":"Phys Med Biol"},{"key":"493_CR14","doi-asserted-by":"publisher","first-page":"1084","DOI":"10.2967\/jnumed.115.167676","volume":"57","author":"Y Yu","year":"2016","unstructured":"Yu Y, Chan C, Ma T, Liu Y, Gallezot J-D, Naganawa M, Kelada OJ, Germino M, Sinusas AJ, Carson RE, Liu C. Event-by-event continuous respiratory motion correction for dynamic PET imaging. J Nucl Med. 2016;57:1084\u201390.","journal-title":"J Nucl Med"},{"key":"493_CR15","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1007\/s11886-017-0825-2","volume":"19","author":"M Rubeaux","year":"2017","unstructured":"Rubeaux M, Doris MK, Alessio A, Slomka PJ. Enhancing cardiac PET by motion correction techniques. Curr Cardiol Rep. 2017;19:14\u20137.","journal-title":"Curr Cardiol Rep"},{"issue":"3","key":"493_CR16","first-page":"1","volume":"27","author":"JW Bellinge","year":"2019","unstructured":"Bellinge JW, Majeed K, Carr SS, Jones J, Hong I, Francis RJ, Schultz CJ. Coronary artery 18F-NaF PET analysis with the use of an elastic motion correction software. J Nucl Cardiol. 2019;27(3):1\u20139.","journal-title":"J Nucl Cardiol"},{"key":"493_CR17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab39c2","volume":"64","author":"Y Petibon","year":"2019","unstructured":"Petibon Y, Sun T, Han PK, Ma C, El FG, Ouyang J. MR-based cardiac and respiratory motion correction of PET: Application to static and dynamic cardiac 18F-FDG imaging. Phys Med Biol. 2019;64: 195009.","journal-title":"Phys Med Biol"},{"key":"493_CR18","doi-asserted-by":"publisher","first-page":"1829","DOI":"10.1118\/1.4943565","volume":"43","author":"C Hunter","year":"2016","unstructured":"Hunter C, Klein R, Beanlands RS, Dekemp RA. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging. Med Phys. 2016;43:1829\u201340.","journal-title":"Med Phys"},{"key":"493_CR19","doi-asserted-by":"publisher","first-page":"1697","DOI":"10.1002\/mp.13419","volume":"46","author":"CRRN Hunter","year":"2019","unstructured":"Hunter CRRN, Klein R, Alessio AM, deKemp RA. Patient body motion correction for dynamic cardiac PET-CT by attenuation-emission alignment according to projection consistency conditions. Med Phys. 2019;46:1697\u2013706.","journal-title":"Med Phys"},{"key":"493_CR20","doi-asserted-by":"publisher","first-page":"4898","DOI":"10.1002\/mp.13815","volume":"46","author":"T Sun","year":"2019","unstructured":"Sun T, Petibon Y, Han PK, Ma C, Kim SJW, Alpert NM, El Fakhri G, Ouyang J. Body motion detection and correction in cardiac PET: phantom and human studies. Med Phys. 2019;46:4898\u2013906.","journal-title":"Med Phys"},{"key":"493_CR21","doi-asserted-by":"publisher","first-page":"1761","DOI":"10.2967\/jnumed.117.206375","volume":"59","author":"A Reilhac","year":"2018","unstructured":"Reilhac A, Merida I, Irace Z, Stephenson MC, Weekes AA, Chen C, Totman JJ, Townsend DW, Fayad H, Costes N. Development of a dedicated rebinner with rigid motion correction for the mMR PET\/MR Scanner, and Validation in a large cohort of 11C-PIB Scans. J Nucl Med. 2018;59:1761\u20137.","journal-title":"J Nucl Med"},{"key":"493_CR22","doi-asserted-by":"publisher","first-page":"871","DOI":"10.2967\/jnumed.120.248856","volume":"62","author":"LK Shiyam Sundar","year":"2021","unstructured":"Shiyam Sundar LK, Iommi D, Muzik O, Chalampalakis Z, Klebermass E-M, Hienert M, Rischka L, Lanzenberger R, Hahn A, Pataraia E, Traub-Weidinger T, Hummel J, Beyer T. Conditional generative adversarial networks aided motion correction of dynamic 18F-FDG PET brain studies. J Nucl Med. 2021;62:871\u20139.","journal-title":"J Nucl Med"},{"key":"493_CR23","doi-asserted-by":"publisher","first-page":"3025","DOI":"10.1118\/1.3589136","volume":"38","author":"B Gu\u00e9rin","year":"2011","unstructured":"Gu\u00e9rin B, Cho S, Chun SY, Zhu X, Alpert NM, El Fakhri G, Reese T, Catana C. Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging. Med Phys. 2011;38:3025\u201338.","journal-title":"Med Phys"},{"key":"493_CR24","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.2967\/jnumed.111.092353","volume":"53","author":"SY Chun","year":"2012","unstructured":"Chun SY, Reese TG, Ouyang J, Guerin B, Catana C, Zhu X, Alpert NM, El Fakhri G. MRI-based nonrigid motion correction in simultaneous PET\/MRI. J Nucl Med. 2012;53:1284\u201391.","journal-title":"J Nucl Med"},{"key":"493_CR25","doi-asserted-by":"publisher","first-page":"082304","DOI":"10.1118\/1.4890095","volume":"41","author":"C Kolbitsch","year":"2014","unstructured":"Kolbitsch C, Prieto C, Tsoumpas C, Schaeffter T. A 3D MR-acquisition scheme for nonrigid bulk motion correction in simultaneous PET-MR. Med Phys. 2014;41:082304.","journal-title":"Med Phys"},{"key":"493_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1475-925X-13-S1-S2","volume":"13","author":"M Fieseler","year":"2014","unstructured":"Fieseler M, Gigengack F, Jiang X, Sch\u00e4fers KP. Motion correction of whole-body PET data with a joint PET-MRI registration functional. Biomed Eng Online. 2014;13:1\u20139.","journal-title":"Biomed Eng Online"},{"key":"493_CR27","first-page":"1","volume":"59","author":"J Bec","year":"2018","unstructured":"Bec J, Henry D, Kyme A, Fulton R, Badawi RD, Cherry SR. Optical motion tracking for use with the EXPLORER total-body PET scanner. J Nucl Med. 2018;59:1\u20135.","journal-title":"J Nucl Med"},{"issue":"6","key":"493_CR28","doi-asserted-by":"publisher","first-page":"1997","DOI":"10.1007\/s00259-021-05623-6","volume":"49","author":"H Sari","year":"2022","unstructured":"Sari H, Mingels C, Alberts I, et al. First results on kinetic modelling and parametric imaging of dynamic 18F-FDG datasets from a long axial FOV PET scanner in oncological patients. Eur J Nucl Med Mol Imaging. 2022;49(6):1997.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"493_CR29","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1007\/s002590050258","volume":"25","author":"JLR Andersson","year":"1998","unstructured":"Andersson JLR. How to obtain high-accuracy image registration: application to movement correction of dynamic positron emission tomography data. Eur J Nucl Med. 1998;25:575\u201386.","journal-title":"Eur J Nucl Med"},{"key":"493_CR30","doi-asserted-by":"publisher","first-page":"3172","DOI":"10.1007\/s00259-020-05134-w","volume":"48","author":"Y Zhou","year":"2021","unstructured":"Zhou Y, Flores S, Mansor S, Hornbeck RC, Tu Z, Perlmutter JS, Ances B, Morris JC, Gropler RJ, Benzinger TLS. Spatially constrained kinetic modeling with dual reference tissues improves 18F-flortaucipir PET in studies of Alzheimer disease. Eur J Nucl Med Mol Imaging. 2021;48:3172\u201386.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"493_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fninf.2014.00044","volume":"8","author":"BB Avants","year":"2014","unstructured":"Avants BB, Tustison NJ, Stauffer M, Song G, Wu B, Gee JC. The insight toolkit image registration framework. Front Neuroinform. 2014;8:1\u201313.","journal-title":"Front Neuroinform"},{"key":"493_CR32","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.media.2007.06.004","volume":"12","author":"BB Avants","year":"2008","unstructured":"Avants BB, Epstein CL, Grossman M, Gee JC. Symmetric diffeomorphic image registration with cross-correlation: evaluating automated labeling of elderly and neurodegenerative brain. Med Image Anal. 2008;12:26\u201341.","journal-title":"Med Image Anal"},{"key":"493_CR33","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1007\/978-3-540-85990-1_117","volume":"5242","author":"JM Peyrat","year":"2008","unstructured":"Peyrat JM, Delingette H, Sermesant M, Pennec X, Xu C, Ayache N. Registration of 4D time-series of cardiac images with multichannel diffeomorphic demons. Lect Notes Comput Sci. 2008;5242:972\u20139.","journal-title":"Lect Notes Comput Sci"},{"key":"493_CR34","doi-asserted-by":"publisher","first-page":"9685","DOI":"10.1073\/pnas.0503892102","volume":"102","author":"MI Miller","year":"2005","unstructured":"Miller MI, Beg MF, Ceritoglu C, Stark C. Increasing the power of functional maps of the medial temporal lobe by using large deformation diffeomorphic metric mapping. Proc Natl Acad Sci U S A. 2005;102:9685\u201390.","journal-title":"Proc Natl Acad Sci U S A"},{"key":"493_CR35","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.mri.2021.10.004","volume":"85","author":"C Munoz","year":"2022","unstructured":"Munoz C, Qi H, Cruz G, K\u00fcstner T, Botnar RM, Prieto C. Self-supervised learning-based diffeomorphic non-rigid motion estimation for fast motion-compensated coronary MR angiography. Magn Reson Imaging. 2022;85:10\u20138.","journal-title":"Magn Reson Imaging"},{"key":"493_CR36","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1007\/BF01589118","volume":"45","author":"MJD Powell","year":"1989","unstructured":"Powell MJD. A tolerant algorithm for linearly constrained optimization calculations. Math Program. 1989;45:547\u201366.","journal-title":"Math Program"},{"key":"493_CR37","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1038\/jcbfm.1984.89","volume":"4","author":"G Blomqvist","year":"1984","unstructured":"Blomqvist G. On the construction of functional maps in positron emission tomography. J Cereb Blood Flow Metab. 1984;4:629\u201332.","journal-title":"J Cereb Blood Flow Metab"},{"key":"493_CR38","doi-asserted-by":"crossref","unstructured":"Sun T, Wang Z, Wu Y, Gu F, Li X, Bai Y, Shen C, Hu Z, Liang D, Liu X, Zheng H, Yang Y, El Fakhri G, Zhou Y, Wang M. Identifying the individual metabolic abnormities from a systemic perspective using whole-body PET imaging. Eur J Nucl Med Mol Imaging.\u00a02022;49(8):2994\u20133004.","DOI":"10.1007\/s00259-022-05832-7"},{"key":"493_CR39","doi-asserted-by":"publisher","first-page":"261","DOI":"10.2967\/jnumed.114.146787","volume":"56","author":"S Furst","year":"2015","unstructured":"Furst S, Grimm R, Hong I, Souvatzoglou M, Casey ME, Schwaiger M, Nekolla SG, Ziegler SI. Motion correction strategies for integrated PET\/MR. J Nucl Med. 2015;56:261\u20139.","journal-title":"J Nucl Med"},{"key":"493_CR40","unstructured":"Hong I, Jones J, Casey M. Elastic motion correction for cardiac PET studies. IEEE Nucl Sci Symp Conf Rec. 2013:2\u20134."},{"key":"493_CR41","doi-asserted-by":"crossref","unstructured":"Feng T, Zhao Y, Shi H, Zhang X, Wang G, Badawi RD, Price PM, Cherry SR, JONES T. Total-Body Quantitative Parametric Imaging of Early Kinetics of FDG. J Nucl Med. 2021;62:738\u2013744.","DOI":"10.2967\/jnumed.119.238113"},{"key":"493_CR42","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac4a8f","volume":"67","author":"T Sun","year":"2022","unstructured":"Sun T, Wu Y, Bai Y, Wang Z, Shen C, Wang W, Li C, Hu Z, Liang D, Liu X, Zheng H, Yang Y, Wang M. An iterative image-based inter-frame motion compensation method for dynamic brain PET imaging. Phys Med Biol. 2022;67: 035012.","journal-title":"Phys Med Biol"},{"key":"493_CR43","doi-asserted-by":"crossref","unstructured":"Mok TCW, Chung ACS. Fast symmetric diffeomorphic image registration with convolutional neural networks. Proc IEEE Comput Soc Conf Comput Vis Pattern Recognit. 2020:4643\u20134652.","DOI":"10.1109\/CVPR42600.2020.00470"},{"key":"493_CR44","doi-asserted-by":"publisher","first-page":"102524","DOI":"10.1016\/j.media.2022.102524","volume":"80","author":"X Guo","year":"2022","unstructured":"Guo X, Zhou B, Pigg D, Spottiswoode B, Casey ME, Liu C, Dvornek NC. Unsupervised inter-frame motion correction for whole-body dynamic PET using convolutional long short-term memory in a convolutional neural network. Med Image Anal. 2022;80:102524.","journal-title":"Med Image Anal"},{"key":"493_CR45","first-page":"46","volume":"2","author":"T Sun","year":"2012","unstructured":"Sun T, Mok GSP. Techniques for respiration-induced artifacts reductions in thoracic PET\/CT. Quant Imaging Med Surg. 2012;2:46\u201352.","journal-title":"Quant Imaging Med Surg"},{"key":"493_CR46","doi-asserted-by":"publisher","first-page":"1496","DOI":"10.1016\/j.neuroimage.2009.05.052","volume":"47","author":"N Costes","year":"2009","unstructured":"Costes N, Dagher A, Larcher K, Evans AC, Collins DL, Reilhac A. Motion correction of multi-frame PET data in neuroreceptor mapping: simulation based validation. Neuroimage. 2009;47:1496\u2013505.","journal-title":"Neuroimage"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-022-00493-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-022-00493-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-022-00493-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,14]],"date-time":"2022-09-14T20:14:01Z","timestamp":1663186441000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-022-00493-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,14]]},"references-count":46,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["493"],"URL":"https:\/\/doi.org\/10.1186\/s40658-022-00493-9","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,14]]},"assertion":[{"value":"12 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. All scans were approved by the Ethics Committee of Henan Provincial People\u2019s Hospital and the People\u2019s Hospital of Zhengzhou (IRB2020123). Informed consent was obtained from all individual participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors agree to publish the paper.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no conflict of interests to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"62"}}