{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T10:45:40Z","timestamp":1791542740298,"version":"4.3.4"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,29]],"date-time":"2024-01-29T00:00:00Z","timestamp":1706486400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,29]],"date-time":"2024-01-29T00:00:00Z","timestamp":1706486400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100014419","name":"EIT Health","doi-asserted-by":"publisher","award":["19037"],"award-info":[{"award-number":["19037"]}],"id":[{"id":"10.13039\/100014419","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014419","name":"EIT Health","doi-asserted-by":"publisher","award":["20648"],"award-info":[{"award-number":["20648"]}],"id":[{"id":"10.13039\/100014419","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014419","name":"EIT Health","doi-asserted-by":"publisher","award":["210995"],"award-info":[{"award-number":["210995"]}],"id":[{"id":"10.13039\/100014419","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Positron emission tomography\u2013magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65\u00a0s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Ten patients being treated with ano-rectal radiotherapy received a <jats:inline-formula><jats:alternatives><jats:tex-math>$$^{18}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mmultiscripts>\n                      <mml:mrow\/>\n                      <mml:mrow\/>\n                      <mml:mn>18<\/mml:mn>\n                    <\/mml:mmultiscripts>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired <jats:italic>t<\/jats:italic> tests with a significance level corrected for multiple testing of <jats:inline-formula><jats:alternatives><jats:tex-math>$$p \\le 0.05\/7 = 0.007$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>\u2264<\/mml:mo>\n                      <mml:mn>0.05<\/mml:mn>\n                      <mml:mo>\/<\/mml:mo>\n                      <mml:mn>7<\/mml:mn>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>0.007<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>. Equivalence margins of <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\pm 3.5\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mo>\u00b1<\/mml:mo>\n                      <mml:mn>3.5<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> were used.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Mean whole-image SUV differences were \u22120.02% (sCTAC) compared to \u22123.0% (MRAC), with larger differences in the bone regions (\u22120.5% to \u221216.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\ge 0.987$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mo>\u2265<\/mml:mo>\n                      <mml:mn>0.987<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>. However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in <jats:inline-formula><jats:alternatives><jats:tex-math>$${\\mathrm {SUV}}_{\\max}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:msub>\n                      <mml:mi>SUV<\/mml:mi>\n                      <mml:mo>max<\/mml:mo>\n                    <\/mml:msub>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> were <jats:inline-formula><jats:alternatives><jats:tex-math>$$1.0 \\pm 0.8\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mn>1.0<\/mml:mn>\n                      <mml:mo>\u00b1<\/mml:mo>\n                      <mml:mn>0.8<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> (\u00b1 standard error, sCTAC) and <jats:inline-formula><jats:alternatives><jats:tex-math>$$-4.6 \\pm 0.9\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mo>-<\/mml:mo>\n                      <mml:mn>4.6<\/mml:mn>\n                      <mml:mo>\u00b1<\/mml:mo>\n                      <mml:mn>0.9<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> (MRAC), and <jats:inline-formula><jats:alternatives><jats:tex-math>$$1.0 \\pm 0.7\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mn>1.0<\/mml:mn>\n                      <mml:mo>\u00b1<\/mml:mo>\n                      <mml:mn>0.7<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> (sCTAC) and <jats:inline-formula><jats:alternatives><jats:tex-math>$$-4.3 \\pm 0.8\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mo>-<\/mml:mo>\n                      <mml:mn>4.3<\/mml:mn>\n                      <mml:mo>\u00b1<\/mml:mo>\n                      <mml:mn>0.8<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> (MRAC) in <jats:inline-formula><jats:alternatives><jats:tex-math>$${\\mathrm {SUV}}_{\\rm mean}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:msub>\n                      <mml:mi>SUV<\/mml:mi>\n                      <mml:mi>mean<\/mml:mi>\n                    <\/mml:msub>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>. The sCTAC was statistically equivalent to CTAC within a <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\pm 3.5\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mo>\u00b1<\/mml:mo>\n                      <mml:mn>3.5<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> equivalence margin for <jats:inline-formula><jats:alternatives><jats:tex-math>$${\\mathrm {SUV}}_{\\max}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:msub>\n                      <mml:mi>SUV<\/mml:mi>\n                      <mml:mo>max<\/mml:mo>\n                    <\/mml:msub>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> and <jats:inline-formula><jats:alternatives><jats:tex-math>$${\\mathrm {SUV}}_{\\rm mean}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:msub>\n                      <mml:mi>SUV<\/mml:mi>\n                      <mml:mi>mean<\/mml:mi>\n                    <\/mml:msub>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> (<jats:inline-formula><jats:alternatives><jats:tex-math>$$p = 0.007$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>0.007<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> and <jats:inline-formula><jats:alternatives><jats:tex-math>$$p = 0.002$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>0.002<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>), whereas the MRAC was not (<jats:inline-formula><jats:alternatives><jats:tex-math>$$p = 0.88$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>0.88<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> and <jats:inline-formula><jats:alternatives><jats:tex-math>$$p = 0.83$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>p<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>0.83<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40\u00a0s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40658-024-00617-3","type":"journal-article","created":{"date-parts":[[2024,1,29]],"date-time":"2024-01-29T04:42:11Z","timestamp":1706503331000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis"],"prefix":"10.1186","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0748-0791","authenticated-orcid":false,"given":"Jonathan J.","family":"Wyatt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep","family":"Kaushik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Cozzini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel A.","family":"Pearson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Petrides","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Wiesinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hazel M.","family":"McCallum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ross J.","family":"Maxwell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,29]]},"reference":[{"issue":"7","key":"617_CR1","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1007\/s00259-016-3307-7","volume":"43","author":"S Leibfarth","year":"2016","unstructured":"Leibfarth S, Simoncic U, M\u00f6nnich D, Welz S, Schmidt H, Schwenzer N, Zips D, Thorwarth D. Analysis of pairwise correlations in multi-parametric PET\/MR data for biological tumor characterization and treatment individualization strategies. Eur J Nucl Med Mol Imaging. 2016;43(7):1199\u2013208.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"4","key":"617_CR2","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1007\/s00259-020-05036-x","volume":"48","author":"OA Catalano","year":"2021","unstructured":"Catalano OA, Lee SI, Parente C, Cauley C, Furtado FS, Striar R, Soricelli A, Salvatore M, Li Y, Umutlu L, Ca\u00f1amaque LG, Groshar D, Mahmood U, Blaszkowsky LS, Ryan DP, Clark JW, Wo J, Hong TS, Kunitake H, Bordeianou L, Berger D, Ricciardi R, Rosen B. Improving staging of rectal cancer in the pelvis: the role of PET\/MRI. Eur J Nucl Med Mol Imaging. 2021;48(4):1235\u201345. https:\/\/doi.org\/10.1007\/s00259-020-05036-x.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"11","key":"617_CR3","doi-asserted-by":"publisher","first-page":"2260","DOI":"10.1007\/s00259-019-04449-7","volume":"46","author":"BJ Amorim","year":"2019","unstructured":"Amorim BJ, Hong TS, Blaszkowsky LS, Ferrone CR, Berger DL, Bordeianou LG, Ricciardi R, Clark JW, Ryan DP, Wo JY, Qadan M, Vangel M, Umutlu L, Groshar D, Ca\u00f1amaques LG, Gervais DA, Mahmood U, Rosen BR, Catalano OA. Clinical impact of PET\/MR in treated colorectal cancer patients. Eur J Nucl Med Mol Imaging. 2019;46(11):2260\u20139. https:\/\/doi.org\/10.1007\/s00259-019-04449-7.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"617_CR4","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.critrevonc.2019.03.008","volume":"139","author":"A Fiorentino","year":"2019","unstructured":"Fiorentino A, Laudicella R, Ciurlia E, Annunziata S, Lancellotta V, Mapelli P, Tuscano C, Caobelli F, Evangelista L, Marino L, Quartuccio N, Fiore M, Borghetti P, Chiaravalloti A, Ricci M, Desideri I, Alongi P. Positron emission tomography with computed tomography imaging (PET\/CT) for the radiotherapy planning definition of the biological target volume: PART 2. Crit Rev Oncol Hematol. 2019;139:117\u201324. https:\/\/doi.org\/10.1016\/j.critrevonc.2019.03.008.","journal-title":"Crit Rev Oncol Hematol"},{"issue":"4","key":"617_CR5","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1016\/j.ijrobp.2020.06.013","volume":"108","author":"AM Couwenberg","year":"2020","unstructured":"Couwenberg AM, Burbach JPM, Berbee M, Lacle MM, Arensman R, Raicu MG, Wessels FJ, Verdult J, Roodhart J, Reerink O, Hoendervangers S, Buijsen J, Grabsch HI, Pronk A, Consten ECJ, Smits AB, Heikens JT, Appelt AL, van Grevenstein WMU, Verkooijen HM, Intven MPW. Efficacy of dose-escalated chemoradiation on complete tumor response in patients with locally advanced rectal cancer (RECTAL-BOOST): a phase 2 randomized controlled trial. Int J Radiat Oncol Biol Phys. 2020;108(4):1008\u201318. https:\/\/doi.org\/10.1016\/j.ijrobp.2020.06.013.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"617_CR6","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1186\/s13014-017-0883-z","volume":"12","author":"E Rusten","year":"2017","unstructured":"Rusten E, Rekstad BL, Undseth C, Al-Haidari G, Hanekamp B, Hernes E, Hellebust TP, Malinen E, Guren MG. Target volume delineation of anal cancer based on magnetic resonance imaging or positron emission tomography. Radiat Oncol. 2017;12(1):147. https:\/\/doi.org\/10.1186\/s13014-017-0883-z.","journal-title":"Radiat Oncol"},{"issue":"2","key":"617_CR7","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1016\/j.ijrobp.2009.01.065","volume":"74","author":"M Karlsson","year":"2009","unstructured":"Karlsson M, Karlsson MG, Nyholm T, Amies C, Zackrisson B. Dedicated magnetic resonance imaging in the radiotherapy clinic. Int J Radiat Oncol Biol Phys. 2009;74(2):644\u201351.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"617_CR8","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s13014-016-0747-y","volume":"12","author":"JM Edmund","year":"2017","unstructured":"Edmund JM, Nyholm T. A review of substitute CT generation for MRI-only radiation therapy. Radiat Oncol. 2017;12(1):28.","journal-title":"Radiat Oncol"},{"issue":"4","key":"617_CR9","doi-asserted-by":"publisher","first-page":"520","DOI":"10.2967\/jnumed.108.054726","volume":"50","author":"A Martinez-M\u00f6ller","year":"2009","unstructured":"Martinez-M\u00f6ller A, Souvatzoglou M, Delso G, Bundschuh RA, Chefd\u2019hotel C, Ziegler SI, Navab N, Schwaiger M, Nekolla SG. Tissue classification as a potential approach for attenuation correction in whole-body PET\/MRI: evaluation with PET\/CT data. J Nucl Med. 2009;50(4):520\u20136. https:\/\/doi.org\/10.2967\/jnumed.108.054726.","journal-title":"J Nucl Med"},{"issue":"5","key":"617_CR10","doi-asserted-by":"publisher","first-page":"852","DOI":"10.2967\/jnumed.117.198051","volume":"59","author":"AP Leynes","year":"2018","unstructured":"Leynes AP, Yang J, Wiesinger F, Kaushik SS, Shanbhag DD, Seo Y, Hope TA, Larson PEZ. Zero-echo-time and dixon deep pseudo-CT (ZeDD CT): direct generation of pseudo-CT images for pelvic PET\/MRI attenuation correction using deep convolutional neural networks with multiparametric MRI. J Nucl Med. 2018;59(5):852\u20138. https:\/\/doi.org\/10.2967\/jnumed.117.198051.","journal-title":"J Nucl Med"},{"issue":"1","key":"617_CR11","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ijrobp.2017.08.043","volume":"100","author":"E Johnstone","year":"2018","unstructured":"Johnstone E, Wyatt JJ, Henry AM, Short SC, Sebag-Montefiore D, Murray L, Kelly CG, McCallum HM, Speight R. A systematic review of synthetic Computed Tomography generation methodologies for use in Magnetic Resonance Imaging\u2014only radiation therapy. Int J Radiat Oncol Biol Phys. 2018;100(1):199\u2013217.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"8","key":"617_CR12","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1080\/0284186X.2021.1936164","volume":"60","author":"S Ahangari","year":"2021","unstructured":"Ahangari S, Hansen NL, Olin AB, N\u00f8ttrup TJ, Ryssel H, Berthelsen AK, L\u00f6fgren J, Loft A, Vogelius IR, Schnack T, Jakoby B, Kjaer A, Andersen FL, Fischer BM, Hansen AE. Toward PET\/MRI as one-stop shop for radiotherapy planning in cervical cancer patients. Acta Oncol. 2021;60(8):1045\u201353. https:\/\/doi.org\/10.1080\/0284186X.2021.1936164.","journal-title":"Acta Oncol"},{"issue":"1","key":"617_CR13","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1186\/s40658-020-00336-5","volume":"7","author":"E Wallst\u00e9n","year":"2020","unstructured":"Wallst\u00e9n E, Axelsson J, Jonsson J, Karlsson CT, Nyholm T, Larsson A. Improved PET\/MRI attenuation correction in the pelvic region using a statistical decomposition method on T2-weighted images. Eur J Nucl Med Mol Imaging Phys. 2020;7(1):68. https:\/\/doi.org\/10.1186\/s40658-020-00336-5.","journal-title":"Eur J Nucl Med Mol Imaging Phys"},{"issue":"1","key":"617_CR14","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s40658-023-00569-0","volume":"10","author":"G Krokos","year":"2023","unstructured":"Krokos G, MacKewn J, Dunn J, Marsden P. A review of PET attenuation correction methods for PET-MR. EJNMMI Phys. 2023;10(1):52. https:\/\/doi.org\/10.1186\/s40658-023-00569-0.","journal-title":"EJNMMI Phys"},{"issue":"3","key":"617_CR15","doi-asserted-by":"publisher","first-page":"138","DOI":"10.18383\/j.tom.2018.00016","volume":"4","author":"TJ Bradshaw","year":"2018","unstructured":"Bradshaw TJ, Zhao G, Jang H, Liu F, McMillan AB. Feasibility of deep learning-based PET\/MR attenuation correction in the pelvis using only diagnostic MR images. Tomography. 2018;4(3):138\u201347. https:\/\/doi.org\/10.18383\/j.tom.2018.00016.","journal-title":"Tomography"},{"key":"617_CR16","doi-asserted-by":"crossref","unstructured":"Abrahamsen BS, Knudtsen IS, Eikenes L, Bathen TF, Elschot M. Pelvic PET\/MR attenuation correction in the image space using deep learning. Front Oncol 2023;13.","DOI":"10.3389\/fonc.2023.1220009"},{"issue":"1","key":"617_CR17","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00259-020-04816-9","volume":"48","author":"A Pozaruk","year":"2021","unstructured":"Pozaruk A, Pawar K, Li S, Carey A, Cheng J, Sudarshan VP, Cholewa M, Grummet J, Chen Z, Egan G. Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging. Eur J Nucl Med Mol Imaging. 2021;48(1):9\u201320. https:\/\/doi.org\/10.1007\/s00259-020-04816-9.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"617_CR18","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.radonc.2023.109692","volume":"184","author":"JJ Wyatt","year":"2023","unstructured":"Wyatt JJ, Kaushik S, Cozzini C, Pearson C, Petit S, Capala M, Hernandez-Tamames JA, Hidegh\u00e9ty K, Maxwell RJ, Wiesinger F, McCallum HM. Comprehensive dose evaluation of a Deep Learning based synthetic computed tomography algorithm for pelvic magnetic resonance-only radiotherapy. Radiother Oncol. 2023;184:10. https:\/\/doi.org\/10.1016\/j.radonc.2023.109692.","journal-title":"Radiother Oncol"},{"issue":"2","key":"617_CR19","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1007\/s11606-010-1513-8","volume":"26","author":"E Walker","year":"2011","unstructured":"Walker E, Nowacki AS. Understanding equivalence and noninferiority testing. J Gen Intern Med. 2011;26(2):192\u20136. https:\/\/doi.org\/10.1007\/s11606-010-1513-8.","journal-title":"J Gen Intern Med"},{"key":"617_CR20","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.phro.2018.09.002","volume":"7","author":"M Maspero","year":"2018","unstructured":"Maspero M, Tyyger MD, Tijssen RHN, Seevinck PR, Intven MPW, van den Berg CAT. Feasibility of magnetic resonance imaging-only rectum radiotherapy with a commercial synthetic computed tomography generation solution. Phys Imaging Radiat Oncol. 2018;7:58\u201364. https:\/\/doi.org\/10.1016\/j.phro.2018.09.002.","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"4","key":"617_CR21","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1002\/mrm.27134","volume":"80","author":"F Wiesinger","year":"2018","unstructured":"Wiesinger F, Bylund M, Yang J, Kaushik S, Shanbhag D, Ahn S, Jonsson JH, Lundman JA, Hope T, Nyholm T, Larson P, Cozzini C. Zero TE-based pseudo-CT image conversion in the head and its application in PET\/MR attenuation correction and MR-guided radiation therapy planning. Magn Reson Med. 2018;80(4):1440\u201351. https:\/\/doi.org\/10.1002\/mrm.27134.","journal-title":"Magn Reson Med"},{"issue":"1","key":"617_CR22","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1002\/mrm.27928","volume":"83","author":"M Engstr\u00f6m","year":"2020","unstructured":"Engstr\u00f6m M, McKinnon G, Cozzini C, Wiesinger F. In-phase zero TE musculoskeletal imaging. Magn Reson Med. 2020;83(1):195\u2013202. https:\/\/doi.org\/10.1002\/mrm.27928.","journal-title":"Magn Reson Med"},{"key":"617_CR23","unstructured":"Lebel R\u00a0M. Performance characterization of a novel deep learning-based MR image reconstruction pipeline, arXiv:2008.06559 [cs, eess] Aug. 2020. arXiv:2008.06559."},{"key":"617_CR24","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.phro.2022.03.003","volume":"22","author":"JJ Wyatt","year":"2022","unstructured":"Wyatt JJ, McCallum HM, Maxwell RJ. Developing quality assurance tests for simultaneous Positron Emission Tomography\u2014Magnetic Resonance imaging for radiotherapy planning. Phys Imaging Radiat Oncol. 2022;22:28\u201335. https:\/\/doi.org\/10.1016\/j.phro.2022.03.003.","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"19","key":"617_CR25","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acefa3","volume":"68","author":"SS Kaushik","year":"2023","unstructured":"Kaushik SS, Bylund M, Cozzini C, Shanbhag D, Petit SF, Wyatt JJ, Menzel MI, Pirkl C, Mehta B, Chauhan V, Chandrasekharan K, Jonsson J, Nyholm T, Wiesinger F, Menze B. Region of interest focused MRI to synthetic CT translation using regression and segmentation multi-task network. Phys Med Biol. 2023;68(19): 195003. https:\/\/doi.org\/10.1088\/1361-6560\/acefa3.","journal-title":"Phys Med Biol"},{"issue":"3","key":"617_CR26","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abce1c","volume":"66","author":"JJ Wyatt","year":"2021","unstructured":"Wyatt JJ, Howell E, Lohezic M, McCallum HM, Maxwell RJ. Evaluating the image quality of combined positron emission tomography-magnetic resonance images acquired in the pelvic radiotherapy position. Phys Med Biol. 2021;66(3): 035018. https:\/\/doi.org\/10.1088\/1361-6560\/abce1c.","journal-title":"Phys Med Biol"},{"key":"617_CR27","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14193","author":"JJ Wyatt","year":"2023","unstructured":"Wyatt JJ, Petrides G, Pearson RA, McCallum HM, Maxwell RJ. Impact of attenuation correction of radiotherapy hardware for positron emission tomography-magnetic resonance in ano-rectal radiotherapy patients. J Appl Clin Med Phys. 2023. https:\/\/doi.org\/10.1002\/acm2.14193.","journal-title":"J Appl Clin Med Phys"},{"issue":"10","key":"617_CR28","doi-asserted-by":"publisher","first-page":"4349","DOI":"10.1118\/1.3213099","volume":"36","author":"E Day","year":"2009","unstructured":"Day E, Betler J, Parda D, Reitz B, Kirichenko A, Mohammadi S, Miften M. A region growing method for tumor volume segmentation on PET images for rectal and anal cancer patients. Med Phys. 2009;36(10):4349\u201358. https:\/\/doi.org\/10.1118\/1.3213099.","journal-title":"Med Phys"},{"key":"617_CR29","doi-asserted-by":"publisher","first-page":"S837","DOI":"10.1016\/S0167-8140(15)41525-7","volume":"115","author":"T Nyholm","year":"2015","unstructured":"Nyholm T, Berglund M, Brynolfsson P, Jonsson J. EP-1533: ICE-Studio\u2014an Interactive visual research tool for image analysis. Radiother Oncol. 2015;115:S837. https:\/\/doi.org\/10.1016\/S0167-8140(15)41525-7.","journal-title":"Radiother Oncol"},{"issue":"2","key":"617_CR30","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1198\/tast.2009.0029","volume":"63","author":"C Lauzon","year":"2009","unstructured":"Lauzon C, Caffo B. Easy multiplicity control in equivalence testing using two one-sided tests. Am Stat. 2009;63(2):147\u201354. https:\/\/doi.org\/10.1198\/tast.2009.0029.","journal-title":"Am Stat"},{"issue":"4","key":"617_CR31","doi-asserted-by":"publisher","first-page":"523","DOI":"10.2967\/jnumed.116.186353","volume":"58","author":"MA Lodge","year":"2017","unstructured":"Lodge MA. Repeatability of SUV in Oncologic 18F-FDG PET. J Nucl Med. 2017;58(4):523\u201332. https:\/\/doi.org\/10.2967\/jnumed.116.186353.","journal-title":"J Nucl Med"},{"issue":"3","key":"617_CR32","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.radonc.2011.12.016","volume":"102","author":"J Buijsen","year":"2012","unstructured":"Buijsen J, van den Bogaard J, van der Weide H, Engelsman S, van Stiphout R, Janssen M, Beets G, Beets-Tan R, Lambin P, Lammering G. FDG\u2013PET\u2013CT reduces the interobserver variability in rectal tumor delineation. Radiother Oncol. 2012;102(3):371\u20136. https:\/\/doi.org\/10.1016\/j.radonc.2011.12.016.","journal-title":"Radiother Oncol"},{"issue":"7048","key":"617_CR33","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1136\/bmj.313.7048.36","volume":"313","author":"B Jones","year":"1996","unstructured":"Jones B, Jarvis P, Lewis J, Ebbutt A. Trials to assess equivalence: the importance of rigorous methods. Br Med J. 1996;313(7048):36.","journal-title":"Br Med J"},{"issue":"5","key":"617_CR34","doi-asserted-by":"publisher","first-page":"701","DOI":"10.2967\/jnumed.111.095299","volume":"53","author":"AJ de Langen","year":"2012","unstructured":"de Langen AJ, Vincent A, Velasquez LM, van Tinteren H, Boellaard R, Shankar LK, Boers M, Smit EF, Stroobants S, Weber WA, Hoekstra OS. Repeatability of 18F-FDG uptake measurements in tumors: a metaanalysis. J Nucl Med. 2012;53(5):701\u20138. https:\/\/doi.org\/10.2967\/jnumed.111.095299.","journal-title":"J Nucl Med"},{"issue":"10","key":"617_CR35","doi-asserted-by":"publisher","first-page":"1646","DOI":"10.2967\/jnumed.109.063347","volume":"50","author":"LM Velasquez","year":"2009","unstructured":"Velasquez LM, Boellaard R, Kollia G, Hayes W, Hoekstra OS, Lammertsma AA, Galbraith SM. Repeatability of 18F-FDG PET in a multicenter phase I study of patients with advanced gastrointestinal malignancies. J Nucl Med. 2009;50(10):1646\u201354. https:\/\/doi.org\/10.2967\/jnumed.109.063347.","journal-title":"J Nucl Med"},{"key":"617_CR36","doi-asserted-by":"publisher","first-page":"153601211878931","DOI":"10.1177\/1536012118789314","volume":"17","author":"MS Shandiz","year":"2018","unstructured":"Shandiz MS, Rad HS, Ghafarian P, Yaghoubi K, Ay MR. Capturing bone signal in MRI of pelvis, as a large FOV Region, using TWIST sequence and generating a 5-class attenuation map for prostate PET\/MRI imaging. Mol Imaging. 2018;17:1536012118789314. https:\/\/doi.org\/10.1177\/1536012118789314.","journal-title":"Mol Imaging"},{"key":"617_CR37","volume":"444","author":"D Thwaites","year":"2013","unstructured":"Thwaites D. Accuracy required and achievable in radiotherapy dosimetry: have modern technology and techniques changed our views? J Phys: Conf Ser. 2013;444: 012006.","journal-title":"J Phys: Conf Ser"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-024-00617-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-024-00617-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-024-00617-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,23]],"date-time":"2024-07-23T10:21:24Z","timestamp":1721730084000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-024-00617-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,29]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["617"],"URL":"https:\/\/doi.org\/10.1186\/s40658-024-00617-3","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,29]]},"assertion":[{"value":"28 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the NHS Health Research Authority London - Dulwich Research Ethics Committee (reference 20\/LO\/0583). All patients gave informed consent prior to participating in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"JW declares receiving an honorarium from GE Healthcare for speaking in a radiation oncology webinar series. HM declares receiving an honorarium from GE Healthcare for giving an oral presentation at European Society of Radiotherapy and Oncology annual conference. SK, CC and FW are employees of GE Healthcare who manufactured the scanner. GP declares receiving fees from GE Healthcare for reporting DaTSCANs and honoraria for DaTSCAN education presentations. None of these impacted the study analysis or the results presented.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10"}}