{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T08:59:19Z","timestamp":1780045159294,"version":"3.53.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T00:00:00Z","timestamp":1724371200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T00:00:00Z","timestamp":1724371200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"DOI":"10.1186\/s40658-024-00676-6","type":"journal-article","created":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T20:15:45Z","timestamp":1724444145000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["From SPECT\/CT towards absolute quantification? - the case of unilateral condylar hyperplasia of the mandible"],"prefix":"10.1186","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4194-0974","authenticated-orcid":false,"given":"Stijn","family":"De Schepper","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4617-9013","authenticated-orcid":false,"given":"Gopinath","family":"Gnanasegaran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wouter","family":"De Vos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0395-3002","authenticated-orcid":false,"given":"Elke","family":"Van de Casteele","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1793-3822","authenticated-orcid":false,"given":"John C.","family":"Dickson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0320-9075","authenticated-orcid":false,"given":"Tim","family":"Van den Wyngaert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,23]]},"reference":[{"issue":"8","key":"676_CR1","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1016\/j.bjoms.2018.07.017","volume":"56","author":"JA Higginson","year":"2018","unstructured":"Higginson JA, Bartram AC, Banks RJ, Keith DJW. Condylar hyperplasia: current thinking. Br J Oral Maxillofac Surg. 2018;56(8):655\u201362.","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"3","key":"676_CR2","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1038\/s41432-023-00927-y","volume":"24","author":"R ElNaghy","year":"2023","unstructured":"ElNaghy R, Hasanin M. Impact of malocclusions on oral health-related quality of life among adolescents. Evid Based Dent. 2023;24(3):140\u20131.","journal-title":"Evid Based Dent"},{"issue":"9","key":"676_CR3","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1007\/s00259-016-3415-4","volume":"43","author":"T Van den Wyngaert","year":"2016","unstructured":"Van den Wyngaert T, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, Mohan HK, et al. The EANM practice guidelines for bone scintigraphy. Eur J Nucl Med Mol Imaging. 2016;43(9):1723\u201338.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"1","key":"676_CR4","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.ijom.2010.09.015","volume":"40","author":"CP Saridin","year":"2011","unstructured":"Saridin CP, Raijmakers PG, Tuinzing DB, Becking AG. Bone scintigraphy as a diagnostic method in unilateral hyperactivity of the mandibular condyles: a review and meta-analysis of the literature. Int J Oral Maxillofac Surg. 2011;40(1):11\u20137.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"9","key":"676_CR5","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1016\/j.ijom.2009.04.019","volume":"38","author":"CP Saridin","year":"2009","unstructured":"Saridin CP, Raijmakers PG, Al Shamma S, Tuinzing DB, Becking AG. Comparison of different analytical methods used for analyzing SPECT scans of patients with unilateral condylar hyperactivity. Int J Oral Maxillofac Surg. 2009;38(9):942\u20136.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"10","key":"676_CR6","doi-asserted-by":"publisher","first-page":"1990","DOI":"10.1007\/s00259-019-04404-6","volume":"46","author":"O Israel","year":"2019","unstructured":"Israel O, Pellet O, Biassoni L, De Palma D, Estrada-Lobato E, Gnanasegaran G, et al. Two decades of SPECT\/CT - the coming of age of a technology: an updated review of literature evidence. Eur J Nucl Med Mol Imaging. 2019;46(10):1990\u20132012.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"11","key":"676_CR7","doi-asserted-by":"publisher","first-page":"1742","DOI":"10.2967\/jnumed.117.205567","volume":"59","author":"T Van den Wyngaert","year":"2018","unstructured":"Van den Wyngaert T, Palli SR, Imhoff RJ, Hirschmann MT. Cost-effectiveness of bone SPECT\/CT in painful total knee arthroplasty. J Nucl Med. 2018;59(11):1742\u201350.","journal-title":"J Nucl Med"},{"issue":"4","key":"676_CR8","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1016\/j.ijom.2017.09.008","volume":"47","author":"BH Chan","year":"2018","unstructured":"Chan BH, Leung YY. SPECT bone scintigraphy for the assessment of condylar growth activity in mandibular asymmetry: is it accurate? Int J Oral Maxillofac Surg. 2018;47(4):470\u20139.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"12","key":"676_CR9","doi-asserted-by":"publisher","first-page":"1607","DOI":"10.1016\/j.ijom.2016.07.002","volume":"45","author":"H Rushinek","year":"2016","unstructured":"Rushinek H, Tabib R, Fleissig Y, Klein M, Tshori S. Evaluation of three analysis methods for (99m)tc MDP SPECT scintigraphy in the diagnosis of unilateral condylar hyperplasia. Int J Oral Maxillofac Surg. 2016;45(12):1607\u201313.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"2","key":"676_CR10","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ijom.2022.08.002","volume":"52","author":"LHE Karssemakers","year":"2023","unstructured":"Karssemakers LHE, Nolte JW, Rehmann C, Raijmakers PG, Becking AG. Diagnostic performance of SPECT-CT imaging in unilateral condylar hyperplasia. Int J Oral Maxillofac Surg. 2023;52(2):199\u2013204.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"8","key":"676_CR11","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.2967\/jnumed.111.100123","volume":"53","author":"YK Dewaraja","year":"2012","unstructured":"Dewaraja YK, Frey EC, Sgouros G, Brill AB, Roberson P, Zanzonico PB, et al. MIRD pamphlet 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy. J Nucl Med. 2012;53(8):1310\u201325.","journal-title":"J Nucl Med"},{"issue":"2","key":"676_CR12","doi-asserted-by":"publisher","first-page":"129","DOI":"10.23736\/S1824-4785.19.03204-7","volume":"63","author":"S De Schepper","year":"2019","unstructured":"De Schepper S, Ritt P, Van den Wyngaert T, Kuwert T. Quantitative radionuclide imaging of bone metastases. Q J Nucl Med Mol Imaging. 2019;63(2):129\u201335.","journal-title":"Q J Nucl Med Mol Imaging"},{"issue":"4","key":"676_CR13","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1007\/s00259-022-06028-9","volume":"50","author":"JC Dickson","year":"2023","unstructured":"Dickson JC, Armstrong IS, Gabina PM, Denis-Bacelar AM, Krizsan AK, Gear JM, et al. EANM practice guideline for quantitative SPECT-CT. Eur J Nucl Med Mol Imaging. 2023;50(4):980\u201395.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"2","key":"676_CR14","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1109\/TMI.2012.2225441","volume":"32","author":"SY Chun","year":"2013","unstructured":"Chun SY, Fessler JA, Dewaraja YK. Correction for collimator-detector response in SPECT using point spread function template. IEEE Trans Med Imaging. 2013;32(2):295\u2013305.","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"676_CR15","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1186\/s40658-021-00394-3","volume":"8","author":"C Chiesa","year":"2021","unstructured":"Chiesa C, Sjogreen-Gleisner K, Walrand S, Strigari L, Flux G, Gear J, et al. EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres. EJNMMI Phys. 2021;8(1):77.","journal-title":"EJNMMI Phys"},{"issue":"6","key":"676_CR16","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1007\/s00259-022-05727-7","volume":"49","author":"K Sjogreen Gleisner","year":"2022","unstructured":"Sjogreen Gleisner K, Chouin N, Gabina PM, Cicone F, Gnesin S, Stokke C, et al. EANM dosimetry committee recommendations for dosimetry of 177Lu-labelled somatostatin-receptor- and PSMA-targeting ligands. Eur J Nucl Med Mol Imaging. 2022;49(6):1778\u2013809.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"676_CR17","doi-asserted-by":"crossref","unstructured":"De Schepper S, Gnanasegaran G, Dickson JC, Van den Wyngaert T. Absolute quantification in diagnostic SPECT\/CT: the Phantom Premise. Diagnostics (Basel). 2021;11(12).","DOI":"10.3390\/diagnostics11122333"},{"issue":"1","key":"676_CR18","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s40658-016-0151-6","volume":"3","author":"JI Gear","year":"2016","unstructured":"Gear JI, Cummings C, Craig AJ, Divoli A, Long CD, Tapner M, et al. Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT. EJNMMI Phys. 2016;3(1):17.","journal-title":"EJNMMI Phys"},{"issue":"12","key":"676_CR19","doi-asserted-by":"publisher","first-page":"1998","DOI":"10.2967\/jnumed.116.178046","volume":"57","author":"J Tran-Gia","year":"2016","unstructured":"Tran-Gia J, Schlogl S, Lassmann M. Design and fabrication of kidney phantoms for Internal Radiation Dosimetry using 3D Printing Technology. J Nucl Med. 2016;57(12):1998\u20132005.","journal-title":"J Nucl Med"},{"issue":"4","key":"676_CR20","doi-asserted-by":"publisher","first-page":"616","DOI":"10.2967\/jnumed.117.200170","volume":"59","author":"J Tran-Gia","year":"2018","unstructured":"Tran-Gia J, Lassmann M. Optimizing image quantification for (177)Lu SPECT\/CT based on a 3D printed 2-Compartment kidney Phantom. J Nucl Med. 2018;59(4):616\u201324.","journal-title":"J Nucl Med"},{"issue":"2","key":"676_CR21","doi-asserted-by":"publisher","first-page":"143","DOI":"10.2967\/jnmt.120.253534","volume":"49","author":"M Fukami","year":"2021","unstructured":"Fukami M, Matsutomo N, Yamamoto T. Optimization of number of iterations as a Reconstruction parameter in bone SPECT imaging using a novel thoracic spine Phantom. J Nucl Med Technol. 2021;49(2):143\u20139.","journal-title":"J Nucl Med Technol"},{"issue":"1","key":"676_CR22","doi-asserted-by":"publisher","first-page":"8242","DOI":"10.1038\/s41598-020-64803-w","volume":"10","author":"A Carass","year":"2020","unstructured":"Carass A, Roy S, Gherman A, Reinhold JC, Jesson A, Arbel T, et al. Evaluating White Matter Lesion segmentations with Refined Sorensen-Dice analysis. Sci Rep. 2020;10(1):8242.","journal-title":"Sci Rep"},{"issue":"3","key":"676_CR23","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1109\/23.596985","volume":"44","author":"V Dreuille Od, Strijckmans","year":"1997","unstructured":"Dreuille Od, Strijckmans V, Ameida P, Loc\u2019h C, Bendriem B. Bone equivalent liquid solution to assess accuracy of transmission measurements in SPECT and PET. IEEE Trans Nucl Sci. 1997;44(3):1186\u201390.","journal-title":"IEEE Trans Nucl Sci"},{"key":"676_CR24","volume-title":"Chapter 20 clinical measurement. An introduction to Medical statistics","author":"M Bland","year":"2015","unstructured":"Bland M. Chapter 20 clinical measurement. An introduction to Medical statistics. Fourth Edition ed: Oxford University Press; 2015."},{"issue":"21","key":"676_CR25","doi-asserted-by":"publisher","first-page":"R119","DOI":"10.1088\/0031-9155\/57\/21\/R119","volume":"57","author":"K Erlandsson","year":"2012","unstructured":"Erlandsson K, Buvat I, Pretorius PH, Thomas BA, Hutton BF. A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys Med Biol. 2012;57(21):R119\u201359.","journal-title":"Phys Med Biol"},{"issue":"22","key":"676_CR26","doi-asserted-by":"publisher","first-page":"7975","DOI":"10.1088\/0031-9155\/61\/22\/7975","volume":"61","author":"BA Thomas","year":"2016","unstructured":"Thomas BA, Cuplov V, Bousse A, Mendes A, Thielemans K, Hutton BF, et al. PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography. Phys Med Biol. 2016;61(22):7975\u201393.","journal-title":"Phys Med Biol"},{"issue":"13","key":"676_CR27","doi-asserted-by":"publisher","first-page":"2456","DOI":"10.1007\/s00259-018-4136-7","volume":"45","author":"JI Gear","year":"2018","unstructured":"Gear JI, Cox MG, Gustafsson J, Gleisner KS, Murray I, Glatting G, et al. EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations. Eur J Nucl Med Mol Imaging. 2018;45(13):2456\u201374.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"676_CR28","doi-asserted-by":"crossref","unstructured":"Lopez DF, Rios Borras V, Munoz JM, Cardenas-Perilla R, Almeida LE. SPECT\/CT correlation in the diagnosis of unilateral Condilar Hyperplasia. Diagnostics (Basel). 2021;11(3).","DOI":"10.3390\/diagnostics11030477"},{"key":"676_CR29","volume-title":"Chapter 13 the analysis of cross-tabulations. An introduction to Medical statistics","author":"M Bland","year":"2015","unstructured":"Bland M. Chapter 13 the analysis of cross-tabulations. An introduction to Medical statistics. Fourth Edition ed: Oxford University Press; 2015."},{"issue":"3","key":"676_CR30","doi-asserted-by":"publisher","first-page":"297","DOI":"10.2307\/1932409","volume":"26","author":"LR Dice","year":"1945","unstructured":"Dice LR. Measures of the Amount of Ecologic Association between Species. Ecology. 1945;26(3):297\u2013302.","journal-title":"Ecology"},{"issue":"3","key":"676_CR31","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.3390\/app11031028","volume":"11","author":"T-H Kim","year":"2021","unstructured":"Kim T-H, Lee D-Y, Jung S-K. Comparison of Trabecular Bone Mineral Density Measurement Using Hounsfield Unit and Trabecular microstructure in Orthodontic patients using Cone-Beam Computed Tomography. Appl Sci. 2021;11(3):1028.","journal-title":"Appl Sci"},{"issue":"1","key":"676_CR32","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/S0278-2391(82)80010-4","volume":"40","author":"LB Kaban","year":"1982","unstructured":"Kaban LB, Cisneros GJ, Heyman S, Treves S. Assessment of mandibular growth by skeletal scintigraphy. J Oral Maxillofac Surg. 1982;40(1):18\u201322.","journal-title":"J Oral Maxillofac Surg"},{"issue":"1","key":"676_CR33","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/s40658-021-00397-0","volume":"8","author":"J Tran-Gia","year":"2021","unstructured":"Tran-Gia J, Denis-Bacelar AM, Ferreira KM, Robinson AP, Calvert N, Fenwick AJ, et al. A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT\/CT imaging performed within the MRTDosimetry project. EJNMMI Phys. 2021;8(1):55.","journal-title":"EJNMMI Phys"},{"issue":"Suppl 1","key":"676_CR34","first-page":"S681","volume":"50","author":"J Leube","year":"2023","unstructured":"Leube J, Gustafsson J, Lassmann MSR, Tran-Gia M. The art of Juggling: on the infuence of Sphere Positioning on Recovery coefcients determined using an IEC-NEMA Phantom. Eur J Nucl Med Mol Imaging. 2023;50(Suppl 1):S681.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"9","key":"676_CR35","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.2967\/jnumed.119.236943","volume":"61","author":"T Van den Wyngaert","year":"2020","unstructured":"Van den Wyngaert T, Elvas F, De Schepper S, Kennedy JA, Israel O. SPECT\/CT: standing on the Shoulders of Giants, it is time to Reach for the Sky! J Nucl Med. 2020;61(9):1284\u201391.","journal-title":"J Nucl Med"},{"issue":"1","key":"676_CR36","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s40658-019-0268-5","volume":"6","author":"SMB Peters","year":"2019","unstructured":"Peters SMB, van der Werf NR, Segbers M, van Velden FHP, Wierts R, Blokland K, et al. Towards standardization of absolute SPECT\/CT quantification: a multi-center and multi-vendor phantom study. EJNMMI Phys. 2019;6(1):29.","journal-title":"EJNMMI Phys"},{"issue":"1","key":"676_CR37","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s40658-020-0278-3","volume":"7","author":"SMB Peters","year":"2020","unstructured":"Peters SMB, Meyer Viol SL, van der Werf NR, de Jong N, van Velden FHP, Meeuwis A, et al. Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT\/CT systems. EJNMMI Phys. 2020;7(1):9.","journal-title":"EJNMMI Phys"},{"issue":"1","key":"676_CR38","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s40658-024-00627-1","volume":"11","author":"V Nuttens","year":"2024","unstructured":"Nuttens V, Schramm G, D\u2019Asseler Y, Koole M. Comparison of a 3D CZT and conventional SPECT\/CT system for quantitative Lu-177 SPECT imaging. EJNMMI Phys. 2024;11(1):29.","journal-title":"EJNMMI Phys"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-024-00676-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-024-00676-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-024-00676-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T20:20:11Z","timestamp":1724444411000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-024-00676-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,23]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["676"],"URL":"https:\/\/doi.org\/10.1186\/s40658-024-00676-6","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,23]]},"assertion":[{"value":"26 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the ethics committee of the Antwerp University Hospital (N\u00b0: 5640).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"74"}}