{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T23:40:09Z","timestamp":1793922009354,"version":"4.8.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T00:00:00Z","timestamp":1743552000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T00:00:00Z","timestamp":1743552000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82171978"],"award-info":[{"award-number":["82171978"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81971647"],"award-info":[{"award-number":["81971647"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"DOI":"10.1186\/s40658-025-00739-2","type":"journal-article","created":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T13:00:11Z","timestamp":1743598811000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Impact of a deep progressive reconstruction algorithm on low-dose or fast-scan PET image quality and Deauville score in patients with lymphoma"],"prefix":"10.1186","volume":"12","author":[{"given":"Wenli","family":"Qiao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taisong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongyuan","family":"Yi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuebing","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Xi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Runze","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Xing","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8867-7985","authenticated-orcid":false,"given":"Jinhua","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,2]]},"reference":[{"issue":"4","key":"739_CR1","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1109\/42.363108","volume":"13","author":"HM Hudson","year":"1994","unstructured":"Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13(4):601\u20139. https:\/\/doi.org\/10.1109\/42.363108.","journal-title":"IEEE Trans Med Imaging"},{"issue":"6","key":"739_CR2","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1088\/0031-9155\/54\/6\/020","volume":"54","author":"N Grotus","year":"2009","unstructured":"Grotus N, Reader AJ, Stute S, Rosenwald JC, Giraud P, Buvat I. Fully 4D list-mode reconstruction applied to respiratory-gated PET scans. Phys Med Biol. 2009;54(6):1705\u201321. https:\/\/doi.org\/10.1088\/0031-9155\/54\/6\/020.","journal-title":"Phys Med Biol"},{"issue":"2","key":"739_CR3","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1055\/s-0038-1625413","volume":"46","author":"G Rizzo","year":"2007","unstructured":"Rizzo G, Castiglioni I, Russo G, Tana MG, Dell\u2019Acqua F, Gilardi MC, et al. Using deconvolution to improve PET spatial resolution in OSEM iterative reconstruction. Methods Inf Med. 2007;46(2):231\u20135.","journal-title":"Methods Inf Med"},{"issue":"1","key":"739_CR4","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1109\/TBME.2020.3042907","volume":"69","author":"N Xie","year":"2022","unstructured":"Xie N, Gong K, Guo N, Qin Z, Wu Z, Liu H, et al. Penalized-likelihood PET image reconstruction using 3D structural convolutional sparse coding. IEEE Trans Biomed Eng. 2022;69(1):4\u201314. https:\/\/doi.org\/10.1109\/TBME.2020.3042907.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"7","key":"739_CR5","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1007\/s00259-023-06134-2","volume":"50","author":"W Ruan","year":"2023","unstructured":"Ruan W, Qin C, Liu F, Pi R, Gai Y, Liu Q, et al. Q.Clear reconstruction for reducing the scanning time for (68) Ga-DOTA-FAPI-04 PET\/MR imaging. Eur J Nucl Med Mol Imaging. 2023;50(7):1851\u201360. https:\/\/doi.org\/10.1007\/s00259-023-06134-2.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"1","key":"739_CR6","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1186\/s13550-020-00690-6","volume":"10","author":"M Wyrzykowski","year":"2020","unstructured":"Wyrzykowski M, Siminiak N, Kazmierczak M, Ruchala M, Czepczynski R. Impact of the Q.Clear reconstruction algorithm on the interpretation of PET\/CT images in patients with lymphoma. EJNMMI Res. 2020;10(1):99. https:\/\/doi.org\/10.1186\/s13550-020-00690-6.","journal-title":"EJNMMI Res"},{"issue":"8","key":"739_CR7","first-page":"1326","volume":"47","author":"YS Jhanwar","year":"2006","unstructured":"Jhanwar YS, Straus DJ. The role of PET in lymphoma. J Nucl Med. 2006;47(8):1326\u201334.","journal-title":"J Nucl Med"},{"issue":"8","key":"739_CR8","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1080\/10428190903040048","volume":"50","author":"M Meignan","year":"2009","unstructured":"Meignan M, Gallamini A, Meignan M, Gallamini A, Haioun C. Report on the first international workshop on interim-PET-scan in lymphoma. Leuk Lymphoma. 2009;50(8):1257\u201360. https:\/\/doi.org\/10.1080\/10428190903040048.","journal-title":"Leuk Lymphoma"},{"issue":"27","key":"739_CR9","doi-asserted-by":"publisher","first-page":"3048","DOI":"10.1200\/JCO.2013.53.5229","volume":"32","author":"SF Barrington","year":"2014","unstructured":"Barrington SF, Mikhaeel NG, Kostakoglu L, Meignan M, Hutchings M, M\u00fceller SP, Schwartz LH, Zucca E, Fisher RI, Trotman J, Hoekstra OS. Role of imaging in the staging and response assessment of lymphoma: consensus of the international conference on malignant lymphomas imaging working group. J Clin Oncol Off J Am Soc Clin Oncol. 2014;32(27):3048\u201358. https:\/\/doi.org\/10.1200\/JCO.2013.53.5229.","journal-title":"J Clin Oncol Off J Am Soc Clin Oncol"},{"issue":"1","key":"739_CR10","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s13550-022-00887-x","volume":"12","author":"AH Dias","year":"2022","unstructured":"Dias AH, Schleyer P, Vendelbo MH, Hjorthaug K, Gormsen LC, Munk OL. Clinical feasibility and impact of data-driven respiratory motion compensation studied in 200 whole-body (18)F-FDG PET\/CT scans. EJNMMI Res. 2022;12(1):16. https:\/\/doi.org\/10.1186\/s13550-022-00887-x.","journal-title":"EJNMMI Res"},{"issue":"10","key":"739_CR11","doi-asserted-by":"publisher","first-page":"105016","DOI":"10.1088\/1361-6560\/abfb17","volume":"66","author":"Y Lv","year":"2021","unstructured":"Lv Y, Xi C. PET image reconstruction with deep progressive learning. Phys Med Biol. 2021;66(10):105016. https:\/\/doi.org\/10.1088\/1361-6560\/abfb17.","journal-title":"Phys Med Biol"},{"issue":"1","key":"739_CR12","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s40658-022-00431-9","volume":"9","author":"Y Xing","year":"2022","unstructured":"Xing Y, Qiao W, Wang T, Wang Y, Li C, Lv Y, et al. Deep learning-assisted PET imaging achieves fast scan\/low-dose examination. EJNMMI Phys. 2022;9(1):7. https:\/\/doi.org\/10.1186\/s40658-022-00431-9.","journal-title":"EJNMMI Phys"},{"issue":"1","key":"739_CR13","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s40658-022-00508-5","volume":"9","author":"T Wang","year":"2022","unstructured":"Wang T, Qiao W, Wang Y, Wang J, Lv Y, Dong Y, et al. Deep progressive learning achieves whole-body low-dose (18)F-FDG PET imaging. EJNMMI Phys. 2022;9(1):82. https:\/\/doi.org\/10.1186\/s40658-022-00508-5.","journal-title":"EJNMMI Phys"},{"issue":"5","key":"739_CR14","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1007\/s00259-022-06078-z","volume":"50","author":"C Qi","year":"2023","unstructured":"Qi C, Wang S, Yu H, Zhang Y, Hu P, Tan H, et al. An artificial intelligence-driven image quality assessment system for whole-body [(18)F]FDG PET\/CT. Eur J Nucl Med Mol Imaging. 2023;50(5):1318\u201328. https:\/\/doi.org\/10.1007\/s00259-022-06078-z.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"6","key":"739_CR15","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1007\/s00259-017-3914-y","volume":"45","author":"T Salomon","year":"2018","unstructured":"Salomon T, Nganoa C, Gac AC, Fruchart C, Damaj G, Aide N, et al. Assessment of alteration in liver (18)F-FDG uptake due to steatosis in lymphoma patients and its impact on the Deauville score. Eur J Nucl Med Mol Imaging. 2018;45(6):941\u201350. https:\/\/doi.org\/10.1007\/s00259-017-3914-y.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"2","key":"739_CR16","doi-asserted-by":"publisher","first-page":"325","DOI":"10.2214\/AJR.19.22705","volume":"215","author":"H Tan","year":"2020","unstructured":"Tan H, Gu Y, Yu H, Hu P, Zhang Y, Mao W, et al. Total-body PET\/CT: current applications and future perspectives. AJR Am J Roentgenol. 2020;215(2):325\u201337. https:\/\/doi.org\/10.2214\/AJR.19.22705.","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"739_CR17","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1007\/s00259-017-3893-z","volume":"45","author":"SF Barrington","year":"2018","unstructured":"Barrington SF, Sulkin T, Forbes A, Johnson PWM. All that glitters is not gold - new reconstruction methods using Deauville criteria for patient reporting. Eur J Nucl Med Mol Imaging. 2018;45(2):316\u20137. https:\/\/doi.org\/10.1007\/s00259-017-3893-z.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"2","key":"739_CR18","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1007\/s00259-014-2961-x","volume":"42","author":"R Boellaard","year":"2015","unstructured":"Boellaard R, Delgado-Bolton R, Oyen WJ, Giammarile F, Tatsch K, Eschner W, et al. FDG PET\/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015;42(2):328\u201354. https:\/\/doi.org\/10.1007\/s00259-014-2961-x.","journal-title":"Eur J Nucl Med Mol Imaging"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00739-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-025-00739-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00739-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T13:00:16Z","timestamp":1743598816000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-025-00739-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,2]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["739"],"URL":"https:\/\/doi.org\/10.1186\/s40658-025-00739-2","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,2]]},"assertion":[{"value":"8 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The clinical institutional review board approved this study. The patients signed a written informed consent form.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"All authors are consent for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"33"}}