{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T22:44:31Z","timestamp":1789598671677,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T00:00:00Z","timestamp":1750291200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T00:00:00Z","timestamp":1750291200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"DOI":"10.1186\/s40658-025-00770-3","type":"journal-article","created":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T03:55:57Z","timestamp":1750305357000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["PET\/CT acquisition and processing protocols in the Netherlands"],"prefix":"10.1186","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5651-5116","authenticated-orcid":false,"given":"Dennis B. M.","family":"Dieckens","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pepijn","family":"van Horssen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8391-0349","authenticated-orcid":false,"given":"Koen A. J.","family":"van Gils","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0395-7476","authenticated-orcid":false,"given":"Arjon J.","family":"van Lange","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8675-8987","authenticated-orcid":false,"given":"Oleksandra V.","family":"Ivashchenko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6293-8956","authenticated-orcid":false,"given":"Wouter J. H.","family":"Veldkamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1237-2891","authenticated-orcid":false,"given":"Adriaan A.","family":"Lammertsma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niels C.","family":"Veltman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,19]]},"reference":[{"issue":"2","key":"770_CR1","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1007\/s00259-014-2961-x","volume":"42","author":"R Boellaard","year":"2015","unstructured":"Boellaard R, Delgado-Bolton R, Oyen WJ, Giammarile F, Tatsch K, Eschner W, Verzijlbergen FJ, Barrington SF, Pike LC, Weber WA, Stroobants S, Delbeke D, Donohoe KJ, Holbrook S, Graham MM, Testanera G, Hoekstra OS, Zijlstra J, Visser E, Hoekstra CJ, Pruim J, Willemsen A, Arends B, Kotzerke J, Bockisch A, Beyer T, Chiti A, Krause BJ. European Association of Nuclear Medicine (EANM). FDG PET\/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015;42(2):328\u201354. https:\/\/doi.org\/10.1007\/s00259-014-2961-x.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"770_CR2","doi-asserted-by":"publisher","first-page":"145","DOI":"10.2967\/jnumed.114.148056","volume":"56","author":"JJ Sunderland","year":"2015","unstructured":"Sunderland JJ, Christian PE. Quantitative PET\/CT scanner performance characterization based upon the society of nuclear medicine and molecular imaging clinical trials network oncology clinical simulator phantom. J Nucl Med. 2015;56:145\u201352. https:\/\/doi.org\/10.2967\/jnumed.114.148056.","journal-title":"J Nucl Med"},{"key":"770_CR3","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1148\/radiol.2019191882","volume":"294","author":"PE Kinahan","year":"2020","unstructured":"Kinahan PE, Perlman ES, Sunderland JJ, Subramaniam R, Wollenweber SD, Turkington TG, et al. The QIBA Profile for FDG PET\/CT as an imaging biomarker measuring response to cancer therapy. Radiology. 2020;294:647\u201357. https:\/\/doi.org\/10.1148\/radiol.2019191882.","journal-title":"Radiology"},{"key":"770_CR4","doi-asserted-by":"publisher","first-page":"102506","DOI":"10.1016\/j.ejmp.2022.11.010","volume":"105","author":"R Matheoud","year":"2023","unstructured":"Matheoud R, Boellaard R, Pike L, Ptacek J, Reyn\u00e9s-Llompart G, Soret M, Vandenberghe S, Zorz A, Julyan P, Rausch I, Sattler B, Manuel SG, Tosi G, Dalianis K, Almeida PMD, Fabbri C, Gawel J, Hadjitheodorou P, Kotzasarlidou M, Viana Miranda Lima T, O\u2019Doherty J, Skovorodko K, Sutov D, Taher A, Valenti M, Vanzi E. EFOMP\u2019s protocol quality controls in PET\/CT and PET\/MR. Phys Med. 2023;105:102506. https:\/\/doi.org\/10.1016\/j.ejmp.2022.11.010.","journal-title":"Phys Med"},{"issue":"7","key":"770_CR5","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1007\/s12149-014-0849-2","volume":"28","author":"H Fukukita","year":"2014","unstructured":"Fukukita H, Suzuki K, Matsumoto K, Terauchi T, Daisaki H, Ikari Y, Shimada N, Senda M. Japanese guideline for the oncology FDG-PET\/CT data acquisition protocol: synopsis of Version 2.0. Ann Nucl Med. 2014;28(7):693\u2013705. https:\/\/doi.org\/10.1007\/s12149-014-0849-2.","journal-title":"Ann Nucl Med"},{"issue":"7","key":"770_CR6","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.2967\/jnumed.118.215418","volume":"60","author":"J van Sluis","year":"2019","unstructured":"van Sluis J, de Jong J, Schaar J, Noordzij W, van Snick P, Dierckx R, Borra R, Willemsen A, Boellaard R. Performance characteristics of the digital biograph vision PET\/CT system. J Nucl Med. 2019;60(7):1031\u20136. https:\/\/doi.org\/10.2967\/jnumed.118.215418.","journal-title":"J Nucl Med"},{"issue":"11","key":"770_CR7","doi-asserted-by":"publisher","first-page":"4498","DOI":"10.1007\/s00330-017-4859-z","volume":"27","author":"I Shiri","year":"2017","unstructured":"Shiri I, Rahmim A, Ghaffarian P, Geramifar P, Abdollahi H, Bitarafan-Rajabi A. The impact of image reconstruction settings on 18F-FDG PET radiomic features: multi-scanner phantom and patient studies. Eur Radiol. 2017;27(11):4498\u2013509. https:\/\/doi.org\/10.1007\/s00330-017-4859-z.","journal-title":"Eur Radiol"},{"key":"770_CR8","unstructured":"Eberl S, Fulton R, Mohamed A, Verschuer A, Fulham M. Comparison of 3 ring and 4 ring Biograph TruePoint PET\/CT Systems JNM. 2008;49(supplement 1):409P"},{"issue":"1","key":"770_CR9","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s40658-015-0132-1","volume":"2","author":"I Rausch","year":"2015","unstructured":"Rausch I, Cal-Gonz\u00e1lez J, Dapra D, Gallowitsch HJ, Lind P, Beyer T, Minear G. Performance evaluation of the Biograph mCT Flow PET\/CT system according to the NEMA NU2-2012 standard. EJNMMI Phys. 2015;2(1):26. https:\/\/doi.org\/10.1186\/s40658-015-0132-1.","journal-title":"EJNMMI Phys"},{"issue":"8","key":"770_CR10","doi-asserted-by":"publisher","first-page":"2375","DOI":"10.1088\/0031-9155\/56\/8\/004","volume":"56","author":"BW Jakoby","year":"2011","unstructured":"Jakoby BW, Bercier Y, Conti M, Casey ME, Bendriem B, Townsend DW. Physical and clinical performance of the mCT time-of-flight PET\/CT scanner. Phys Med Biol. 2011;56(8):2375\u201389. https:\/\/doi.org\/10.1088\/0031-9155\/56\/8\/004.","journal-title":"Phys Med Biol"},{"issue":"1","key":"770_CR11","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/s40658-020-00323-w","volume":"7","author":"T Carlier","year":"2020","unstructured":"Carlier T, Ferrer L, Conti M, Bodet-Milin C, Rousseau C, Bercier Y, Bendriem B, Kraeber-Bod\u00e9r\u00e9 F. From a PMT-based to a SiPM-based PET system: a study to define matched acquisition\/reconstruction parameters and NEMA performance of the Biograph Vision 450. EJNMMI Phys. 2020;7(1):55. https:\/\/doi.org\/10.1186\/s40658-020-00323-w.","journal-title":"EJNMMI Phys"},{"issue":"4","key":"770_CR12","doi-asserted-by":"publisher","first-page":"561","DOI":"10.2967\/jnumed.118.215541","volume":"60","author":"I Rausch","year":"2019","unstructured":"Rausch I, Ruiz A, Valverde-Pascual I, Cal-Gonz\u00e1lez J, Beyer T, Carrio I. Performance evaluation of the Vereos PET\/CT system according to the NEMA NU2-2012 Standard. J Nucl Med. 2019;60(4):561\u20137. https:\/\/doi.org\/10.2967\/jnumed.118.215541.","journal-title":"J Nucl Med"},{"issue":"3","key":"770_CR13","first-page":"471","volume":"48","author":"S Surti","year":"2007","unstructured":"Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS. Performance of Philips Gemini TF PET\/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med. 2007;48(3):471\u201380 (PMID: 17332626).","journal-title":"J Nucl Med"},{"issue":"14","key":"770_CR14","doi-asserted-by":"publisher","first-page":"3843","DOI":"10.1088\/0031-9155\/59\/14\/3843","volume":"59","author":"JA Kolthammer","year":"2014","unstructured":"Kolthammer JA, Su KH, Grover A, Narayanan M, Jordan DW, Muzic RF. Performance evaluation of the Ingenuity TF PET\/CT scanner with a focus on high count-rate conditions. Phys Med Biol. 2014;59(14):3843\u201359. https:\/\/doi.org\/10.1088\/0031-9155\/59\/14\/3843.","journal-title":"Phys Med Biol"},{"issue":"1","key":"770_CR15","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40658-020-0271-x","volume":"7","author":"A Chicheportiche","year":"2020","unstructured":"Chicheportiche A, Marciano R, Orevi M. Comparison of NEMA characterizations for Discovery MI and Discovery MI-DR TOF PET\/CT systems at different sites and with other commercial PET\/CT systems. EJNMMI Phys. 2020;7(1):4. https:\/\/doi.org\/10.1186\/s40658-020-0271-x.","journal-title":"EJNMMI Phys"},{"issue":"7","key":"770_CR16","doi-asserted-by":"publisher","first-page":"3025","DOI":"10.1002\/mp.13576","volume":"46","author":"T Pan","year":"2019","unstructured":"Pan T, Einstein SA, Kappadath SC, Grogg KS, Lois Gomez C, Alessio AM, Hunter WC, El Fakhri G, Kinahan PE, Mawlawi OR. Performance evaluation of the 5-Ring GE Discovery MI PET\/CT system using the national electrical manufacturers association NU 2\u20132012 Standard. Med Phys. 2019;46(7):3025\u201333. https:\/\/doi.org\/10.1002\/mp.13576.","journal-title":"Med Phys"},{"key":"770_CR17","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.ejmp.2017.09.124.Sharma","volume":"42","author":"K Wagatsuma","year":"2017","unstructured":"Wagatsuma K, Miwa K, Sakata M, Oda K, Ono H, Kameyama M, Toyohara J, Ishii K. Comparison between new-generation SiPM-based and conventional PMT-based TOF-PET\/CT. Phys Med. 2017;42:203\u201310. https:\/\/doi.org\/10.1016\/j.ejmp.2017.09.124.Sharma.","journal-title":"Phys Med"},{"key":"770_CR18","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s40658-019-0244-0","volume":"6","author":"D Vandendriessche","year":"2019","unstructured":"Vandendriessche D, Uribe J, Bertin H, et al. Performance characteristics of silicon photomultiplier based 15-cm AFOV TOF PET\/CT. EJNMMI Phys. 2019;6:8. https:\/\/doi.org\/10.1186\/s40658-019-0244-0.","journal-title":"EJNMMI Phys"},{"key":"770_CR19","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40658-020-0271-x","volume":"7","author":"A Chicheportiche","year":"2020","unstructured":"Chicheportiche A, Marciano R, Orevi M. Comparison of NEMA characterizations for Discovery MI and Discovery MI-DR TOF PET\/CT systems at different sites and with other commercial PET\/CT systems. EJNMMI Phys. 2020;7:4. https:\/\/doi.org\/10.1186\/s40658-020-0271-x.","journal-title":"EJNMMI Phys"},{"issue":"1","key":"770_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/oxfordjournals.rpd.a006705","volume":"98","author":"D Delacroix","year":"2002","unstructured":"Delacroix D, Guerre JP, Leblanc P, Hickman C. Radionuclide and radiation protection data handbook 2002. Radiat Prot Dosimetry. 2002;98(1):1\u2013168. https:\/\/doi.org\/10.1093\/oxfordjournals.rpd.a006705.","journal-title":"Radiat Prot Dosimetry"},{"key":"770_CR21","doi-asserted-by":"publisher","DOI":"10.1186\/s13550-019-0540-7","author":"M Hohberg","year":"2019","unstructured":"Hohberg M, Kobe C, Krapf P, T\u00e4ger P, Hammes J, Dietlein F, Zlatopolskiy BD, Endepols H, Wild M, Neubauer S, Heidenreich A, Neumaier B, Drzezga A, Dietlein M. Biodistribution and radiation dosimetry of [18F]-JK-PSMA-7 as a novel prostate-specific membrane antigen-specific ligand for PET\/CT imaging of prostate cancer. EJNMMI Res. 2019. https:\/\/doi.org\/10.1186\/s13550-019-0540-7.","journal-title":"EJNMMI Res"},{"issue":"12","key":"770_CR22","doi-asserted-by":"publisher","first-page":"1736","DOI":"10.2967\/jnumed.118.225250","volume":"60","author":"S Piron","year":"2019","unstructured":"Piron S, De Man K, Van Laeken N, D\u2019Asseler Y, Bacher K, Kersemans K, Ost P, Decaestecker K, Deseyne P, Fonteyne V, Lumen N, Achten E, Brans B, De Vos F. Radiation dosimetry and biodistribution of 18F-PSMA-11 for PET imaging of prostate cancer. J Nucl Med. 2019;60(12):1736\u201342. https:\/\/doi.org\/10.2967\/jnumed.118.225250.","journal-title":"J Nucl Med"},{"key":"770_CR23","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/2197-7364-1-12","volume":"1","author":"JM Rogasch","year":"2014","unstructured":"Rogasch JM, Hofheinz F, Lougovski A, et al. The influence of different signal-to-background ratios on spatial resolution and F18-FDG-PET quantification using point spread function and time-of-flight reconstruction. EJNMMI Phys. 2014;1:12. https:\/\/doi.org\/10.1186\/2197-7364-1-12.","journal-title":"EJNMMI Phys"},{"issue":"1","key":"770_CR24","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.remnie.2012.11.012","volume":"32","author":"JM Mart\u00ed-Climent","year":"2013","unstructured":"Mart\u00ed-Climent JM, Prieto E, Dom\u00ednguez-Prado I, Garc\u00eda-Velloso MJ, Rodr\u00edguez-Fraile M, Arbizu J, Vigil C, Caicedo C, Pe\u00f1uelas I, Richter JA. Contribution of time of flight and point spread function modeling to the performance characteristics of the PET\/CT Biograph mCT scanner. Rev Esp Med Nucl Imagen Mol. 2013;32(1):13\u201321. https:\/\/doi.org\/10.1016\/j.remnie.2012.11.012.","journal-title":"Rev Esp Med Nucl Imagen Mol"},{"key":"770_CR25","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s40658-019-0251-1","volume":"6","author":"SK \u00d8en","year":"2019","unstructured":"\u00d8en SK, Aasheim LB, Eikenes L, et al. Image quality and detectability in Siemens Biograph PET\/MRI and PET\/CT systems\u2014a phantom study. EJNMMI Phys. 2019;6:16. https:\/\/doi.org\/10.1186\/s40658-019-0251-1.","journal-title":"EJNMMI Phys"},{"issue":"3","key":"770_CR26","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1109\/TNS.2016.2518177","volume":"63","author":"AM Morey","year":"2016","unstructured":"Morey AM, Noo F, Kadrmas DJ. Effect of using 2 mm voxels on observer performance for PET lesion detection. IEEE Trans Nucl Sci. 2016;63(3):1359\u201366. https:\/\/doi.org\/10.1109\/TNS.2016.2518177.","journal-title":"IEEE Trans Nucl Sci"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00770-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-025-00770-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00770-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T03:55:59Z","timestamp":1750305359000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-025-00770-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,19]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["770"],"URL":"https:\/\/doi.org\/10.1186\/s40658-025-00770-3","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,19]]},"assertion":[{"value":"22 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"57"}}