{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T11:23:23Z","timestamp":1767612203256,"version":"3.44.0"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T00:00:00Z","timestamp":1753833600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T00:00:00Z","timestamp":1753833600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Simultaneous PET\/MR imaging enables precise anatomical localization and PET quantification by reducing PET-to-MR misalignments. However, involuntary motion during scans may still cause misalignment and quantification imprecision. Current mutual information (MI)-based co-registration methods do not account for the tissue-specific uptake patterns of PET and therefore could result in suboptimal alignment. To address this, we proposed a novel image co-registration method, namely the tracer characteristic-based co-registration (TCBC) method, which takes advantage of specific PET uptake patterns within a selected anatomical region to improve the image alignment and PET quantification.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>TCBC was evaluated using simulation and in vivo <jats:sup>18<\/jats:sup>F-Florbetapir PET\/MR data from the OASIS-3 dataset. In simulations, TCBC demonstrated superior alignment accuracy with lower root mean square error and higher R-squared values compared to the conventional MI-based co-registration from FreeSurfer in recovering the simulated patient motion. In the retrospective human study, we evaluated the detectability of age-related amyloid burden in healthy controls under different co-registration methods as a demonstrative use case. TCBC significantly enhanced the detectability of age-related amyloid burden with stronger correlations across all five regions of evaluation, such as the medial orbitofrontal cortex (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), precuneus (<jats:italic>p<\/jats:italic>\u2009=\u20090.004), and early amyloid-\u03b2 composite (<jats:italic>p<\/jats:italic>\u2009=\u20090.002), compared to FSMC (<jats:italic>p<\/jats:italic>\u2009=\u20090.004, 0.007, and 0.006, respectively) and uncorrected (<jats:italic>p<\/jats:italic>\u2009=\u20090.378, 0.023, and 0.039, respectively) methods. Bootstrap analyses also confirmed TCBC\u2019s robustness in smaller samples, yielding tighter confidence intervals and lower means of p-values, such as 0.032 (95% CI: 0.029\u20130.035) in the precuneus and 0.008 (CI: 0.007\u20130.010) in the medial orbitofrontal cortex, outperforming FSMC (<jats:italic>p<\/jats:italic>\u2009=\u20090.046 with CI: 0.042\u20130.049, and <jats:italic>p<\/jats:italic>\u2009=\u20090.040 with CI: 0.036\u20130.044, respectively).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The TCBC method reduces image misalignment, improves PET quantification, and may have a good potential for being applied to both research and clinical studies with simultaneous brain PET\/MR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Clinical trial number<\/jats:title>\n            <jats:p>Not applicable.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40658-025-00789-6","type":"journal-article","created":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:23:30Z","timestamp":1753874610000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Motion correction of simultaneous brain PET\/MR images based on tracer uptake characteristics"],"prefix":"10.1186","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-4657-4926","authenticated-orcid":false,"given":"Sheng-Chieh","family":"Chiu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6088-3173","authenticated-orcid":false,"given":"Jose Angelo U.","family":"Perucho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1039-7983","authenticated-orcid":false,"given":"Yu-Hua Dean","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,30]]},"reference":[{"key":"789_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13550-018-0371-y","volume":"8","author":"A Firouzian","year":"2018","unstructured":"Firouzian A, Whittington A, Searle GE, Koychev I, Zamboni G, Lovestone S, et al. Imaging A\u03b2 and Tau in early stage alzheimer\u2019s disease with [18F] AV45 and [18F] AV1451. EJNMMI Res. 2018;8:1\u20139.","journal-title":"EJNMMI Res"},{"key":"789_CR2","first-page":"1059","volume":"46","author":"H Herzog","year":"2005","unstructured":"Herzog H, Tellmann L, Fulton R, Stangier I, Kops ER, Bente K, et al. Motion artifact reduction on parametric PET images of neuroreceptor binding. J Nucl Med. 2005;46:1059\u201365.","journal-title":"J Nucl Med"},{"key":"789_CR3","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.neuroimage.2013.12.061","volume":"91","author":"C Huang","year":"2014","unstructured":"Huang C, Ackerman JL, Petibon Y, Normandin MD, Brady TJ, El Fakhri G, et al. Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET\u2013MR: Phantom and non-human primate studies. NeuroImage. 2014;91:129\u201337.","journal-title":"NeuroImage"},{"doi-asserted-by":"crossref","unstructured":"Dupont P. A role of PET\/MR imaging in dementia? Elsevier; 2021. pp. 296\u2013302.","key":"789_CR4","DOI":"10.1053\/j.semnuclmed.2021.01.003"},{"key":"789_CR5","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1088\/0031-9155\/48\/8\/301","volume":"48","author":"PM Bloomfield","year":"2003","unstructured":"Bloomfield PM, Spinks TJ, Reed J, Schnorr L, Westrip AM, Livieratos L, et al. The design and implementation of a motion correction scheme for neurological PET. Phys Med Biol. 2003;48:959.","journal-title":"Phys Med Biol"},{"key":"789_CR6","doi-asserted-by":"publisher","first-page":"154","DOI":"10.2967\/jnumed.110.079343","volume":"52","author":"C Catana","year":"2011","unstructured":"Catana C, Benner T, van der Kouwe A, Byars L, Hamm M, Chonde DB, et al. MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner. J Nucl Med. 2011;52:154\u201361.","journal-title":"J Nucl Med"},{"doi-asserted-by":"crossref","unstructured":"Dinelle K, Blinder S, Cheng J-C, Lidstone S, Buckley K, Ruth TJ, et al. Investigation of subject motion encountered during a typical positron emission tomography scan. IEEE; 2006. pp. 3283\u20137.","key":"789_CR7","DOI":"10.1109\/NSSMIC.2006.353709"},{"key":"789_CR8","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1109\/TRPMS.2018.2878978","volume":"3","author":"MG Spangler-Bickell","year":"2018","unstructured":"Spangler-Bickell MG, Khalighi MM, Hoo C, DiGiacomo PS, Maclaren J, Aksoy M, et al. Rigid motion correction for brain PET\/MR imaging using optical tracking. IEEE Trans Radiation Plasma Med Sci. 2018;3:498\u2013503.","journal-title":"IEEE Trans Radiation Plasma Med Sci"},{"key":"789_CR9","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1109\/TNS.2002.998691","volume":"49","author":"RR Fulton","year":"2002","unstructured":"Fulton RR, Meikle SR, Eberl S, Pfeiffer J, Constable CJ. Correction for head movements in positron emission tomography using an optical motion-tracking system. IEEE Trans Nucl Sci. 2002;49:116\u201323.","journal-title":"IEEE Trans Nucl Sci"},{"key":"789_CR10","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1109\/42.563664","volume":"16","author":"F Maes","year":"1997","unstructured":"Maes F, Collignon A, Vandermeulen D, Marchal G, Suetens P. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imaging. 1997;16:187\u201398.","journal-title":"IEEE Trans Med Imaging"},{"key":"789_CR11","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1118\/1.598130","volume":"24","author":"C Studholme","year":"1997","unstructured":"Studholme C, Hill DL, Hawkes DJ. Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. Med Phys. 1997;24:25\u201335.","journal-title":"Med Phys"},{"doi-asserted-by":"crossref","unstructured":"Monti S, Cavaliere C, Covello M, Nicolai E, Salvatore M, Aiello M. An evaluation of the benefits of simultaneous acquisition on PET\/MR coregistration in head\/neck imaging. Journal of healthcare engineering. 2017;2017.","key":"789_CR12","DOI":"10.1155\/2017\/2634389"},{"key":"789_CR13","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1109\/TMI.2003.815867","volume":"22","author":"JP Pluim","year":"2003","unstructured":"Pluim JP, Maintz JA, Viergever MA. Mutual-information-based registration of medical images: a survey. IEEE Trans Med Imaging. 2003;22:986\u20131004.","journal-title":"IEEE Trans Med Imaging"},{"key":"789_CR14","doi-asserted-by":"publisher","first-page":"198","DOI":"10.2967\/jnumed.108.057984","volume":"50","author":"MT Fodero-Tavoletti","year":"2009","unstructured":"Fodero-Tavoletti MT, Rowe CC, McLean CA, Leone L, Li Q-X, Masters CL, et al. Characterization of PiB binding to white matter in alzheimer disease and other dementias. J Nucl Med. 2009;50:198\u2013204.","journal-title":"J Nucl Med"},{"doi-asserted-by":"crossref","unstructured":"Pluim JP, Maintz J, Viergever MA. Image registration by maximization of combined mutual information and gradient information. Springer; 2000. pp. 452\u201361.","key":"789_CR15","DOI":"10.1007\/978-3-540-40899-4_46"},{"key":"789_CR16","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1109\/TIP.2014.2387019","volume":"24","author":"J Woo","year":"2014","unstructured":"Woo J, Stone M, Prince JL. Multimodal registration via mutual information incorporating geometric and Spatial context. IEEE Trans Image Process. 2014;24:757\u201369.","journal-title":"IEEE Trans Image Process"},{"key":"789_CR17","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1016\/j.neuroimage.2016.02.042","volume":"132","author":"DN Greve","year":"2016","unstructured":"Greve DN, Salat DH, Bowen SL, Izquierdo-Garcia D, Schultz AP, Catana C, et al. Different partial volume correction methods lead to different conclusions: an 18F-FDG-PET study of aging. NeuroImage. 2016;132:334\u201343.","journal-title":"NeuroImage"},{"key":"789_CR18","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/S0031-3203(98)00091-0","volume":"32","author":"C Studholme","year":"1999","unstructured":"Studholme C, Hill DL, Hawkes DJ. An overlap invariant entropy measure of 3D medical image alignment. Pattern Recogn. 1999;32:71\u201386.","journal-title":"Pattern Recogn"},{"doi-asserted-by":"crossref","unstructured":"LaMontagne PJ, Benzinger TL, Morris JC, Keefe S, Hornbeck R, Xiong C et al. OASIS-3: longitudinal neuroimaging, clinical, and cognitive dataset for normal aging and Alzheimer disease. MedRxiv. 2019.","key":"789_CR19","DOI":"10.1101\/2019.12.13.19014902"},{"key":"789_CR20","doi-asserted-by":"publisher","first-page":"913","DOI":"10.2967\/jnumed.109.069088","volume":"51","author":"DF Wong","year":"2010","unstructured":"Wong DF, Rosenberg PB, Zhou Y, Kumar A, Raymont V, Ravert HT, et al. In vivo imaging of amyloid deposition in alzheimer disease using the radioligand 18F-AV-45 (flobetapir F 18). J Nucl Med. 2010;51:913\u201320.","journal-title":"J Nucl Med"},{"key":"789_CR21","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.neuroimage.2014.11.058","volume":"107","author":"Y Su","year":"2015","unstructured":"Su Y, Blazey TM, Snyder AZ, Raichle ME, Marcus DS, Ances BM, et al. Partial volume correction in quantitative amyloid imaging. NeuroImage. 2015;107:55\u201364.","journal-title":"NeuroImage"},{"key":"789_CR22","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1137\/S1052623496303470","volume":"9","author":"JC Lagarias","year":"1998","unstructured":"Lagarias JC, Reeds JA, Wright MH, Wright PE. Convergence properties of the Nelder\u2013Mead simplex method in low dimensions. SIAM J Optim. 1998;9:112\u201347.","journal-title":"SIAM J Optim"},{"key":"789_CR23","doi-asserted-by":"publisher","first-page":"2412","DOI":"10.1212\/WNL.43.11.2412-a","volume":"43","author":"JC Morris","year":"1993","unstructured":"Morris JC. The clinical dementia rating (CDR): current version and scoring rules. Neurology. 1993;43:2412\u20134.","journal-title":"Neurology"},{"key":"789_CR24","doi-asserted-by":"publisher","first-page":"1887","DOI":"10.2967\/jnumed.109.065284","volume":"50","author":"SR Choi","year":"2009","unstructured":"Choi SR, Golding G, Zhuang Z, Zhang W, Lim N, Hefti F, et al. Preclinical properties of 18F-AV-45: a PET agent for A\u03b2 plaques in the brain. J Nucl Med. 2009;50:1887\u201394.","journal-title":"J Nucl Med"},{"key":"789_CR25","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1016\/j.neuroimage.2012.01.021","volume":"62","author":"B Fischl","year":"2012","unstructured":"Fischl B. FreeSurfer Neuroimage. 2012;62:774\u201381.","journal-title":"FreeSurfer Neuroimage"},{"key":"789_CR26","doi-asserted-by":"publisher","first-page":"175","DOI":"10.2967\/jnmt.115.156679","volume":"43","author":"L Trembath","year":"2015","unstructured":"Trembath L, Newell M, Devous MD. Technical considerations in brain amyloid PET imaging with 18F-Florbetapir. J Nucl Med Technol. 2015;43:175\u201384.","journal-title":"J Nucl Med Technol"},{"key":"789_CR27","doi-asserted-by":"publisher","first-page":"1914","DOI":"10.2967\/jnumed.111.092726","volume":"52","author":"G Delso","year":"2011","unstructured":"Delso G, F\u00fcrst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, et al. Performance measurements of the Siemens mMR integrated Whole-Body PET\/MR scanner. J Nucl Med. 2011;52:1914\u201322.","journal-title":"J Nucl Med"},{"key":"789_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.neurobiolaging.2012.04.017","volume":"34","author":"AS Fleisher","year":"2013","unstructured":"Fleisher AS, Chen K, Liu X, Ayutyanont N, Roontiva A, Thiyyagura P, et al. Apolipoprotein E \u03b54 and age effects on Florbetapir positron emission tomography in healthy aging and alzheimer disease. Neurobiol Aging. 2013;34:1\u201312.","journal-title":"Neurobiol Aging"},{"key":"789_CR29","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1007\/s11910-009-0051-4","volume":"9","author":"DA Wolk","year":"2009","unstructured":"Wolk DA, Klunk WE. Update on amyloid imaging: from healthy aging to alzheimer\u2019s disease. Curr Neurol Neurosci Rep. 2009;9:345.","journal-title":"Curr Neurol Neurosci Rep"},{"key":"789_CR30","doi-asserted-by":"publisher","first-page":"291","DOI":"10.3233\/JAD-200162","volume":"76","author":"P Chatterjee","year":"2020","unstructured":"Chatterjee P, Mohammadi M, Goozee K, Shah TM, Sohrabi HR, Dias CB, et al. Serum Hepcidin levels in cognitively normal older adults with high neocortical Amyloid-\u03b2 load. J Alzheimer\u2019s Disease. 2020;76:291\u2013301.","journal-title":"J Alzheimer\u2019s Disease"},{"key":"789_CR31","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1038\/s41467-017-01150-x","volume":"8","author":"S Palmqvist","year":"2017","unstructured":"Palmqvist S, Sch\u00f6ll M, Strandberg O, Mattsson N, Stomrud E, Zetterberg H, et al. Earliest accumulation of \u03b2-amyloid occurs within the default-mode network and concurrently affects brain connectivity. Nat Commun. 2017;8:1214.","journal-title":"Nat Commun"},{"key":"789_CR32","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1212\/WNL.0b013e318245d295","volume":"78","author":"K Rodrigue","year":"2012","unstructured":"Rodrigue K, Kennedy K, Devous Sr M, Rieck J, Hebrank A, Diaz-Arrastia R, et al. \u03b2-Amyloid burden in healthy aging: regional distribution and cognitive consequences. Neurology. 2012;78:387\u201395.","journal-title":"Neurology"},{"key":"789_CR33","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1001\/jama.2010.2008","volume":"305","author":"CM Clark","year":"2011","unstructured":"Clark CM, Schneider JA, Bedell BJ, Beach TG, Bilker WB, Mintun MA, et al. Use of florbetapir-PET for imaging \u03b2-amyloid pathology. JAMA. 2011;305:275\u201383.","journal-title":"JAMA"},{"key":"789_CR34","doi-asserted-by":"publisher","first-page":"378","DOI":"10.2967\/jnumed.111.090340","volume":"53","author":"AD Joshi","year":"2012","unstructured":"Joshi AD, Pontecorvo MJ, Clark CM, Carpenter AP, Jennings DL, Sadowsky CH, et al. Performance characteristics of amyloid PET with Florbetapir F 18 in patients with alzheimer\u2019s disease and cognitively normal subjects. J Nucl Med. 2012;53:378\u201384.","journal-title":"J Nucl Med"},{"key":"789_CR35","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.jalz.2015.05.001","volume":"11","author":"WJ Jagust","year":"2015","unstructured":"Jagust WJ, Landau SM, Koeppe RA, Reiman EM, Chen K, Mathis CA, et al. The alzheimer\u2019s disease neuroimaging initiative 2 PET core: 2015. Alzheimers Dement. 2015;11:757\u201371.","journal-title":"Alzheimers Dement"},{"key":"789_CR36","doi-asserted-by":"publisher","first-page":"567","DOI":"10.2967\/jnumed.114.148981","volume":"56","author":"SM Landau","year":"2015","unstructured":"Landau SM, Fero A, Baker SL, Koeppe R, Mintun M, Chen K, et al. Measurement of longitudinal \u03b2-amyloid change with 18F-florbetapir PET and standardized uptake value ratios. J Nucl Med. 2015;56:567\u201374.","journal-title":"J Nucl Med"},{"key":"789_CR37","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1016\/j.jalz.2017.02.009","volume":"13","author":"AS Fleisher","year":"2017","unstructured":"Fleisher AS, Joshi AD, Sundell KL, Chen Y-F, Kollack-Walker S, Lu M, et al. Use of white matter reference regions for detection of change in Florbetapir positron emission tomography from completed phase 3 Solanezumab trials. Alzheimer\u2019s Dement. 2017;13:1117\u201324.","journal-title":"Alzheimer\u2019s Dement"},{"key":"789_CR38","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.2967\/jnumed.117.204271","volume":"59","author":"VJ Lowe","year":"2018","unstructured":"Lowe VJ, Lundt ES, Senjem ML, Schwarz CG, Min H-K, Przybelski SA, et al. White matter reference region in PET studies of 11\u00a0C-Pittsburgh compound B uptake: effects of age and amyloid-\u03b2 deposition. J Nucl Med. 2018;59:1583\u20139.","journal-title":"J Nucl Med"},{"doi-asserted-by":"crossref","unstructured":"Efron B. Bootstrap methods: another look at the jackknife. Breakthroughs in statistics: methodology and distribution. Springer; 1992. pp. 569\u201393.","key":"789_CR39","DOI":"10.1007\/978-1-4612-4380-9_41"},{"key":"789_CR40","doi-asserted-by":"publisher","first-page":"e601","DOI":"10.1212\/WNL.0000000000006875","volume":"92","author":"R Ossenkoppele","year":"2019","unstructured":"Ossenkoppele R, Smith R, Ohlsson T, Strandberg O, Mattsson N, Insel PS, et al. Associations between tau, A\u03b2, and cortical thickness with cognition in alzheimer disease. Neurology. 2019;92:e601\u201312.","journal-title":"Neurology"},{"key":"789_CR41","doi-asserted-by":"publisher","first-page":"041910","DOI":"10.1118\/1.4868457","volume":"41","author":"C Huang","year":"2014","unstructured":"Huang C, Ackerman JL, Petibon Y, Brady TJ, El Fakhri G, Ouyang J. MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET\u2010MR: Phantom study. Med Phys. 2014;41:041910.","journal-title":"Med Phys"},{"key":"789_CR42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40658-014-0106-8","volume":"2","author":"SH Keller","year":"2015","unstructured":"Keller SH, Hansen C, Hansen C, Andersen FL, Ladefoged C, Svarer C, et al. Motion correction in simultaneous PET\/MR brain imaging using sparsely sampled MR navigators: a clinically feasible tool. EJNMMI Phys. 2015;2:1\u20137.","journal-title":"EJNMMI Phys"},{"key":"789_CR43","doi-asserted-by":"publisher","first-page":"e0272768","DOI":"10.1371\/journal.pone.0272768","volume":"17","author":"TR Tumpa","year":"2022","unstructured":"Tumpa TR, Acuff SN, Gregor J, Bradley Y, Fu Y, Osborne DR. Data-driven head motion correction for PET using time-of-flight and positron emission particle tracking techniques. PLoS ONE. 2022;17:e0272768.","journal-title":"PLoS ONE"},{"key":"789_CR44","doi-asserted-by":"publisher","first-page":"S72","DOI":"10.1016\/j.jalz.2012.10.007","volume":"9","author":"KA Johnson","year":"2013","unstructured":"Johnson KA, Sperling RA, Gidicsin CM, Carmasin JS, Maye JE, Coleman RE, et al. Florbetapir (F18-AV-45) PET to assess amyloid burden in alzheimer\u2019s disease dementia, mild cognitive impairment, and normal aging. Alzheimer\u2019s Dement. 2013;9:S72\u201383.","journal-title":"Alzheimer\u2019s Dement"},{"key":"789_CR45","doi-asserted-by":"publisher","first-page":"1094","DOI":"10.1016\/j.neuroimage.2013.08.020","volume":"84","author":"P Cumming","year":"2014","unstructured":"Cumming P. PET neuroimaging: the white elephant packs his trunk? NeuroImage. 2014;84:1094\u2013100.","journal-title":"NeuroImage"},{"key":"789_CR46","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/s13195-021-00933-1","volume":"14","author":"AM Pietroboni","year":"2022","unstructured":"Pietroboni AM, Colombi A, Carandini T, Sacchi L, Fenoglio C, Marotta G, et al. Amyloid PET imaging and dementias: potential applications in detecting and quantifying early white matter damage. Alzheimer\u2019s Res Therapy. 2022;14:33.","journal-title":"Alzheimer\u2019s Res Therapy"},{"key":"789_CR47","doi-asserted-by":"publisher","first-page":"2854","DOI":"10.1093\/cercor\/bhu080","volume":"25","author":"K Blackmon","year":"2015","unstructured":"Blackmon K, Kuzniecky R, Barr WB, Snuderl M, Doyle W, Devinsky O, et al. Cortical gray\u2013white matter blurring and cognitive morbidity in focal cortical dysplasia. Cereb Cortex. 2015;25:2854\u201362.","journal-title":"Cereb Cortex"},{"key":"789_CR48","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.cpet.2013.10.006","volume":"9","author":"V Berti","year":"2014","unstructured":"Berti V, Mosconi L, Pupi A. Brain: normal variations and benign findings in fluorodeoxyglucose-PET\/computed tomography imaging. PET Clin. 2014;9:129\u201340.","journal-title":"PET Clin"},{"key":"789_CR49","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1145\/358669.358692","volume":"24","author":"MA Fischler","year":"1981","unstructured":"Fischler MA, Bolles RC. Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM. 1981;24:381\u201395.","journal-title":"Commun ACM"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00789-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-025-00789-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00789-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T09:02:36Z","timestamp":1757322156000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-025-00789-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,30]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["789"],"URL":"https:\/\/doi.org\/10.1186\/s40658-025-00789-6","relation":{},"ISSN":["2197-7364"],"issn-type":[{"type":"electronic","value":"2197-7364"}],"subject":[],"published":{"date-parts":[[2025,7,30]]},"assertion":[{"value":"15 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"75"}}