{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T11:39:26Z","timestamp":1787312366481,"version":"build-2736575974"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T00:00:00Z","timestamp":1759190400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T00:00:00Z","timestamp":1759190400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Misregistration between CT and PET can result in mis-localization and inaccurate quantification of the tracer uptake in PET. Data-driven gated (DDG) CT can correct registration and quantification but requires a radiation dose of 1.3 mSv and 1\u00a0min of acquisition time. AI registration (AIR) does not require an additional CT and has been validated to improve registration and reduce the \u2018banana\u2019 misregistration artifacts around the diaphragm. We aimed to compare a validated AIR and DDG CT in registration and quantification of avid thoracic lesions misregistered in DDG PET scans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Thirty PET\/CT patient data (23 with\n                      <jats:sup>18<\/jats:sup>\n                      F-FDG, 4 with\n                      <jats:sup>68<\/jats:sup>\n                      Ga-Dotatate, and 3 with\n                      <jats:sup>18<\/jats:sup>\n                      F-PSMA piflufolastat) with at least one misregistered avid lesion in the thorax were recruited. Patient studies were conducted using DDG CT to correct misregistration with DDG PET data of the phases 30 to 80% on GE Discovery MI PET\/CT scanners. Non-attenuation correction DDG PET and misregistered CT were input to AIR and the AIR-corrected CT data were output to register and quantify the DDG PET data. Registration and quantification of lesion SUV\n                      <jats:sub>max<\/jats:sub>\n                      and signal-to-background ratio (SBR) of the lesion SUV\n                      <jats:sub>max<\/jats:sub>\n                      to the 2-cm background mean SUV were compared for each of the 51 avid lesions.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      DDG CT outperformed AIR in misregistration correction and quantification of avid thoracic lesions (1.16\u2009\u00b1\u20090.45\u00a0cm). Most lesions (46\/51, 90%) showed improved registration from DDG CT relative to AIR, with 10% (5\/51) being similar between AIR and DDG CT. The lesions in the baseline CT were an average of 2.06\u2009\u00b1\u20091.0\u00a0cm from their corresponding lesions in the DDG CT, while those in the AIR CT were an average of 0.97\u2009\u00b1\u20090.54\u00a0cm away. AIR significantly improved lesion registration compared to the baseline CT (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.0001). SUV\n                      <jats:sub>max<\/jats:sub>\n                      increased by 18.1\u2009\u00b1\u200915.3% with AIR, but a statistically significantly larger increase of 34.4\u2009\u00b1\u200925.4% was observed with DDG CT (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.0001). A statistically significant increase in SBR was also observed, rising from 10.5\u2009\u00b1\u200912.1% of AIR to 21.1\u2009\u00b1\u200920.5% of DDG CT (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.0001). Many registration improvements by AIR were still left with misregistration. AIR could mis-localize a lymph node to the lung parenchyma or the ribs, and could also mis-localize a lung nodule to the left atrium. AIR could also distort the rib cage and the circular shape of the aorta cross section.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>DDG CT outperformed AIR in both localization and quantification of the thoracic avid lesions. AIR improved registration of the misregistered PET\/CT. Registered lymph nodes could be falsely misregistered by AIR. AIR-induced distortion of the rib cage can also negatively impact image quality. Further research on AIR\u2019s accuracy in modeling true patient respiratory motion without introducing new misregistration or anatomical distortion is warranted.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40658-025-00797-6","type":"journal-article","created":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T12:21:12Z","timestamp":1759234872000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Improving data-driven gated (DDG) PET and CT registration in thoracic lesions: a comparison of AI registration and DDG CT"],"prefix":"10.1186","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8511-3746","authenticated-orcid":false,"given":"Tinsu","family":"Pan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. Allan","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dershan","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,30]]},"reference":[{"key":"797_CR1","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s40134-013-0016-x","volume":"1","author":"J Czernin","year":"2013","unstructured":"Czernin J, Allen-Auerbach M, Nathanson D, Herrmann K. PET\/CT in oncology: current status and perspectives. Curr Radiol Rep. 2013;1:177\u201390. https:\/\/doi.org\/10.1007\/s40134-013-0016-x","journal-title":"Curr Radiol Rep"},{"key":"797_CR2","first-page":"1481","volume":"46","author":"T Pan","year":"2005","unstructured":"Pan T, Mawlawi O, Nehmeh SA, Erdi YE, Luo D, Liu HH, et al. Attenuation correction of PET images with respiration-averaged CT images in PET\/CT. J Nucl Med. 2005;46:1481\u20137.","journal-title":"J Nucl Med"},{"key":"797_CR3","doi-asserted-by":"publisher","first-page":"3148","DOI":"10.1088\/0031-9155\/61\/8\/3148","volume":"61","author":"BF Holman","year":"2016","unstructured":"Holman BF, Cuplov V, Hutton BF, Groves AM, Thielemans K. The effect of respiratory induced density variations on non-TOF PET quantitation in the lung. Phys Med Biol. 2016;61:3148\u201363. https:\/\/doi.org\/10.1088\/0031-9155\/61\/8\/3148","journal-title":"Phys Med Biol"},{"key":"797_CR4","doi-asserted-by":"publisher","first-page":"4955","DOI":"10.1118\/1.2986145","volume":"35","author":"T Pan","year":"2008","unstructured":"Pan T, Mawlawi O. PET\/CT in radiation oncology. Med Phys. 2008;35:4955\u201366. https:\/\/doi.org\/10.1118\/1.2986145","journal-title":"Med Phys"},{"key":"797_CR5","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.2967\/jnumed.107.039792","volume":"48","author":"KL Gould","year":"2007","unstructured":"Gould KL, Pan T, Loghin C, Johnson NP, Guha A, Sdringola S. Frequent diagnostic errors in cardiac PET\/CT due to misregistration of CT Attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections. J Nucl Med. 2007;48:1112\u201321. https:\/\/doi.org\/10.2967\/jnumed.107.039792","journal-title":"J Nucl Med"},{"key":"797_CR6","doi-asserted-by":"publisher","first-page":"3931","DOI":"10.1118\/1.2349843","volume":"33","author":"T Pan","year":"2006","unstructured":"Pan T, Mawlawi O, Luo D, Liu HH, Chi PC, Mar MV, et al. Attenuation correction of PET cardiac data with low-dose average CT in PET\/CT. Med Phys. 2006;33:3931\u20138. https:\/\/doi.org\/10.1118\/1.2349843","journal-title":"Med Phys"},{"key":"797_CR7","doi-asserted-by":"publisher","first-page":"1678","DOI":"10.2967\/jnumed.120.242248","volume":"61","author":"MD Walker","year":"2020","unstructured":"Walker MD, Morgan AJ, Bradley KM, McGowan DR. Data-Driven respiratory gating outperforms Device-Based gating for clinical (18)F-FDG PET\/CT. J Nucl Med. 2020;61:1678\u201383. https:\/\/doi.org\/10.2967\/jnumed.120.242248","journal-title":"J Nucl Med"},{"key":"797_CR8","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00259-001-0710-4","volume":"29","author":"GW Goerres","year":"2002","unstructured":"Goerres GW, Kamel E, Heidelberg TN, Schwitter MR, Burger C, von Schulthess GK. PET-CT image co-registration in the thorax: influence of respiration. Eur J Nucl Med Mol Imaging. 2002;29:351\u201360. https:\/\/doi.org\/10.1007\/s00259-001-0710-4","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"797_CR9","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.cmpb.2008.06.014","volume":"92","author":"J Daouk","year":"2008","unstructured":"Daouk J, Fin L, Bailly P, Meyer ME. Improved Attenuation correction via appropriate selection of respiratory-correlated PET data. Comput Methods Programs Biomed. 2008;92:90\u20138. https:\/\/doi.org\/10.1016\/j.cmpb.2008.06.014","journal-title":"Comput Methods Programs Biomed"},{"key":"797_CR10","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-024-07032-x","author":"AH Dias","year":"2024","unstructured":"Dias AH, Schaefferkoetter J, Madsen JR, Barkholt TO, Vendelbo MH, Rodell AB, et al. Validation and clinical impact of motion-free PET imaging using data-driven respiratory gating and elastic PET-CT registration. Eur J Nucl Med Mol Imaging. 2024. https:\/\/doi.org\/10.1007\/s00259-024-07032-x","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"797_CR11","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1007\/s12149-020-01574-4","volume":"35","author":"SY Kang","year":"2021","unstructured":"Kang SY, Moon BS, Kim HO, Yoon HJ, Kim BS. The impact of data-driven respiratory gating in clinical F-18 FDG PET\/CT: comparison of free breathing and deep-expiration breath-hold CT protocol. Ann Nucl Med. 2021;35:328\u201337. https:\/\/doi.org\/10.1007\/s12149-020-01574-4","journal-title":"Ann Nucl Med"},{"key":"797_CR12","doi-asserted-by":"publisher","first-page":"3597","DOI":"10.1002\/mp.15620","volume":"49","author":"T Pan","year":"2022","unstructured":"Pan T, Thomas MA, Luo D. Data-driven gated CT: an automated respiratory gating method to enable data-driven gated PET\/CT. Med Phys. 2022;49:3597\u2013611. https:\/\/doi.org\/10.1002\/mp.15620","journal-title":"Med Phys"},{"key":"797_CR13","doi-asserted-by":"publisher","first-page":"1638","DOI":"10.1016\/j.ijrobp.2020.11.014","volume":"109","author":"T Pan","year":"2021","unstructured":"Pan T, Lu Y, Thomas MA, Liao Z, Luo D. New Data-Driven gated PET\/CT free of misregistration artifacts. Int J Radiat Oncol Biol Phys. 2021;109:1638\u201346. https:\/\/doi.org\/10.1016\/j.ijrobp.2020.11.014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"797_CR14","doi-asserted-by":"publisher","first-page":"1047215","DOI":"10.3389\/fonc.2022.1047215","volume":"12","author":"J Zou","year":"2022","unstructured":"Zou J, Gao B, Song Y, Qin J. A review of deep learning-based deformable medical image registration. Front Oncol. 2022;12:1047215. https:\/\/doi.org\/10.3389\/fonc.2022.1047215","journal-title":"Front Oncol"},{"key":"797_CR15","doi-asserted-by":"publisher","first-page":"2292","DOI":"10.1007\/s00259-023-06181-9","volume":"50","author":"J Schaefferkoetter","year":"2023","unstructured":"Schaefferkoetter J, Shah V, Hayden C, Prior JO, Zuehlsdorff S. Deep learning for improving PET\/CT Attenuation correction by elastic registration of anatomical data. Eur J Nucl Med Mol Imaging. 2023;50:2292\u2013304. https:\/\/doi.org\/10.1007\/s00259-023-06181-9","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"797_CR16","doi-asserted-by":"publisher","first-page":"1626","DOI":"10.1002\/mp.16958","volume":"51","author":"P Sun","year":"2024","unstructured":"Sun P, Thomas MA, Luo D, Pan T. Correcting CT misregistration in data-driven gated (DDG) PET with PET self-gating and deformable image registration. Med Phys. 2024;51:1626\u201336. https:\/\/doi.org\/10.1002\/mp.16958","journal-title":"Med Phys"},{"key":"797_CR17","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1186\/s40658-024-00644-0","volume":"11","author":"EL Cook","year":"2024","unstructured":"Cook EL, Su K-H, Higgins GS, Johnsen R, Bouhnik J-P, McGowan DR. Data-driven gating (DDG)-based motion match for improved CTAC registration. EJNMMI Phys. 2024;11:42. https:\/\/doi.org\/10.1186\/s40658-024-00644-0","journal-title":"EJNMMI Phys"},{"key":"797_CR18","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/978-3-030-00919-9_7","volume-title":"Machine learning in medical imaging","author":"X Cao","year":"2018","unstructured":"Cao X, Yang J, Wang L, Xue Z, Wang Q, Shen D. Deep learning based Inter-modality image registration supervised by Intra-modality similarity. In: Shi Y, Suk H-I, Liu M, editors. Machine learning in medical imaging. Cham: Springer International Publishing; 2018. pp. 55\u201363."},{"key":"797_CR19","doi-asserted-by":"crossref","unstructured":"Sun L, Zhang S, Deformable. MRI-Ultrasound registration using 3D convolutional neural network. POCUS\/BIVPCS\/CuRIOUS\/CPM@MICCAI; 2018.","DOI":"10.1007\/978-3-030-01045-4_18"},{"key":"797_CR20","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1016\/j.acra.2024.09.044","volume":"32","author":"JH Chamberlin","year":"2025","unstructured":"Chamberlin JH, Schaefferkoetter J, Hamill J, Kabakus IM, Horn KP, O\u2019Doherty J, et al. Clinical pilot of a deep learning elastic registration algorithm to improve misregistration artifact and image quality on routine oncologic PET\/CT. Acad Radiol. 2025;32:1015\u201325. https:\/\/doi.org\/10.1016\/j.acra.2024.09.044","journal-title":"Acad Radiol"},{"key":"797_CR21","doi-asserted-by":"publisher","first-page":"3025","DOI":"10.1002\/mp.13576","volume":"46","author":"T Pan","year":"2019","unstructured":"Pan T, Einstein SA, Kappadath SC, Grogg KS, Lois Gomez C, Alessio AM, et al. Performance evaluation of the 5-Ring GE discovery MI PET\/CT system using the National electrical manufacturers association NU 2-2012 standard. Med Phys. 2019;46:3025\u201333. https:\/\/doi.org\/10.1002\/mp.13576","journal-title":"Med Phys"},{"key":"797_CR22","doi-asserted-by":"publisher","first-page":"2238","DOI":"10.1111\/jgs.12580","volume":"61","author":"A Rodriguez-Molinero","year":"2013","unstructured":"Rodriguez-Molinero A, Narvaiza L, Ruiz J, Galvez-Barron C. Normal respiratory rate and peripheral blood oxygen saturation in the elderly population. J Am Geriatr Soc. 2013;61:2238\u201340. https:\/\/doi.org\/10.1111\/jgs.12580","journal-title":"J Am Geriatr Soc"},{"key":"797_CR23","doi-asserted-by":"publisher","first-page":"308","DOI":"10.2214\/AJR.04.1740","volume":"186","author":"O Mawlawi","year":"2006","unstructured":"Mawlawi O, Erasmus JJ, Munden RF, Pan T, Knight AE, Macapinlac HA, et al. Quantifying the effect of IV contrast media on integrated PET\/CT: clinical evaluation. AJR Am J Roentgenol. 2006;186:308\u201319. https:\/\/doi.org\/10.2214\/AJR.04.1740","journal-title":"AJR Am J Roentgenol"},{"key":"797_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00259-024-06838-z","volume":"51","author":"T Pan","year":"2024","unstructured":"Pan T, Luo D. Misregistration correction of 650 PET\/CT scans with data-driven gated CT (Abstract: EP-0678). Eur J Nucl Med Mol Imaging. 2024;51:1\u20131026. https:\/\/doi.org\/10.1007\/s00259-024-06838-z","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"797_CR25","doi-asserted-by":"publisher","first-page":"2408","DOI":"10.1002\/mp.14106","volume":"47","author":"R Werner","year":"2020","unstructured":"Werner R, Sentker T, Madesta F, Schwarz A, Vornehm M, Gauer T, et al. Intelligent 4D CT sequence scanning (i4DCT): first scanner prototype implementation and Phantom measurements of automated breathing signal-guided 4D CT. Med Phys. 2020;47:2408\u201312. https:\/\/doi.org\/10.1002\/mp.14106","journal-title":"Med Phys"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00797-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-025-00797-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-025-00797-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T12:21:13Z","timestamp":1759234873000},"score":1,"resource":{"primary":{"URL":"https:\/\/ejnmmiphys.springeropen.com\/articles\/10.1186\/s40658-025-00797-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,30]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["797"],"URL":"https:\/\/doi.org\/10.1186\/s40658-025-00797-6","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,30]]},"assertion":[{"value":"19 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research was supported in part by R01HL157273-02 and R01-EB034692-01A1. The views expressed are solely those of the authors and do not reflect those of the National Institutes of Health, MD Anderson Cancer Center, or Washington University School of Medicine.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclaimer"}},{"value":"Tinsu Pan is a consultant for Bracco Medical Systems, LLC. The other authors have no relevant financial or non-financial interests to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of the University of Texas, M.D. Anderson Cancer Center under the Institution Review Board (IRB) # 2021\u2009\u2212\u20090999.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"No informed consent was obtained as the data were collected in a standard patient care procedure and were analyzed retrospectively.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"No informed consent was obtained for the publication of the patient data as the data were stripped of the patient information according to the IRB.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}],"article-number":"87"}}