{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T00:13:42Z","timestamp":1773274422367,"version":"3.50.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T00:00:00Z","timestamp":1770422400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T00:00:00Z","timestamp":1773187200000},"content-version":"vor","delay-in-days":32,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"DOI":"10.1186\/s40658-026-00834-y","type":"journal-article","created":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T10:25:09Z","timestamp":1770459909000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Systematic parameter mapping for Wavelet-Based scatter correction in SPECT: clinical perception versus quantitative metrics"],"prefix":"10.1186","volume":"13","author":[{"given":"Shabnam","family":"Oloomi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amirhossein","family":"Fathabadi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,7]]},"reference":[{"key":"834_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics14131431","volume":"14","author":"Y Bouchareb","year":"2024","unstructured":"Bouchareb Y, AlSaadi A, Zabah J, Jain A, Al-Jabri A, Phiri P, et al. Technological advances in SPECT and SPECT\/CT imaging. Diagnostics. 2024;14:1431.","journal-title":"Diagnostics"},{"key":"834_CR2","doi-asserted-by":"crossref","unstructured":"Xia Y, Chen Z, Zhang L, Xing Y, Gao H. ComptoNet: an end-to-end deep learning framework for scatter estimation in multi-source stationary CT. arXiv preprint https:\/\/arxiv.org\/abs\/2501.09986. 2025.","DOI":"10.1088\/1361-6560\/adebd7"},{"key":"834_CR3","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/18\/10\/P10009","volume":"18","author":"M Can","year":"2023","unstructured":"Can M, Karadeniz I, \u0103apa Kaya G, Ertay T. A study on energy window-based scatter correction methods in 99mTc and 123I imaging. J Instrum. 2023;18:P10009.","journal-title":"J Instrum"},{"key":"834_CR4","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0269542","volume":"17","author":"K Miwa","year":"2022","unstructured":"Miwa K, Nemoto R, Masuko H, Yamao T, Kobayashi R, Miyaji N, et al. Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT\/CT imaging. PLoS ONE. 2022;17:e0269542.","journal-title":"PLoS ONE"},{"key":"834_CR5","doi-asserted-by":"publisher","first-page":"5503","DOI":"10.1118\/1.4962469","volume":"43","author":"P Prior","year":"2016","unstructured":"Prior P, Timmins R, Petryk J, Strydhorst J, Duan Y, Wei L, et al. A modified TEW approach to scatter correction for In\u2010111 and Tc\u201099m dual\u2010isotope small\u2010animal SPECT. Med Phys. 2016;43:5503\u201313.","journal-title":"Med Phys"},{"key":"834_CR6","doi-asserted-by":"publisher","first-page":"R85","DOI":"10.1088\/0031-9155\/56\/14\/R01","volume":"56","author":"BF Hutton","year":"2011","unstructured":"Hutton BF, Buvat I, Beekman FJ. Review and current status of SPECT scatter correction. Phys Med Biol. 2011;56:R85.","journal-title":"Phys Med Biol"},{"key":"834_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/nano15020117","volume":"15","author":"JC Chow","year":"2025","unstructured":"Chow JC. Monte Carlo simulations in nanomedicine: advancing cancer imaging and therapy. Nanomaterials. 2025;15:117.","journal-title":"Nanomaterials"},{"key":"834_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-025-00733-8","volume":"12","author":"LE Westlund Gotby","year":"2025","unstructured":"Westlund Gotby LE, Stella M, Van Speybroeck CD, Lobeek D, van Velden FH, Stam MK, et al. Towards harmonized holmium-166 SPECT image quality for dosimetry: a multi-center, multi-vendor study. EJNMMI Phys. 2025;12:24.","journal-title":"EJNMMI Phys"},{"key":"834_CR9","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1097\/MNM.0000000000000079","volume":"35","author":"R De Nijs","year":"2014","unstructured":"De Nijs R, Lagerburg V, Klausen TL, Holm S. Improving quantitative dosimetry in 177Lu-DOTATATE SPECT by energy window-based scatter corrections. Nucl Med Commun. 2014;35:522\u201333.","journal-title":"Nucl Med Commun"},{"key":"834_CR10","first-page":"19","volume":"21","author":"MH Saffar","year":"2013","unstructured":"Saffar MH, Oloomi S, Knoll P, Taleshi H. A new approach to scatter correction in SPECT images based on Klein_Nishina equation. Iran J Nucl Med. 2013;21:19\u201325.","journal-title":"Iran J Nucl Med"},{"key":"834_CR11","doi-asserted-by":"publisher","first-page":"2036","DOI":"10.1109\/TNS.2015.2448673","volume":"62","author":"LC Johnson","year":"2015","unstructured":"Johnson LC, Ovchinnikov O, Shokouhi S, Peterson TE. Development of a germanium small-animal SPECT system. IEEE Trans Nucl Sci. 2015;62:2036\u201342.","journal-title":"IEEE Trans Nucl Sci"},{"key":"834_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2018.09.065","volume":"954","author":"E Wulf","year":"2020","unstructured":"Wulf E, Hou W, De Geronimo G, Roberts J, Boggs S, Phlips B. Front-end ASIC for germanium strip detectors. Nucl Instrum Methods Phys Res A. 2020;954:161230.","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"834_CR13","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1002\/ima.22034","volume":"23","author":"J Wen","year":"2013","unstructured":"Wen J, Li Y, Wang W. Wavelet\u2010based denoising and its impact on analytical SPECT reconstruction with nonuniform attenuation compensation. Int J Imaging Syst Technol. 2013;23:36\u201343.","journal-title":"Int J Imaging Syst Technol"},{"key":"834_CR14","doi-asserted-by":"publisher","first-page":"49","DOI":"10.6009\/jjrt.2013_JSRT_69.1.49","volume":"69","author":"N Matsutomo","year":"2013","unstructured":"Matsutomo N, Onishi H, Nagaki A, Kinda A. Fundamental evaluation of wavelet transform based noise reduction using soft threshold method in single photon emission computed tomography image. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2013;69:49\u201357.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"834_CR15","doi-asserted-by":"publisher","first-page":"59","DOI":"10.18502\/fbt.v11i2.15335","volume":"5","author":"M Saeidikia","year":"2024","unstructured":"Saeidikia M, Seyedarabi H, Mahmoudian B, Islamian JP. Improvement of basal ganglia detectability in brain single photon emission computerized tomography by wavelet transformation in image processing domain: a XCAT Phantom study. Front Biomed Technol. 2024;5:59\u201389. https:\/\/doi.org\/10.18502\/fbt.v11i2.15335.","journal-title":"Front Biomed Technol."},{"key":"834_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.acha.2024.101724","volume":"75","author":"R Morel","year":"2025","unstructured":"Morel R, Rochette G, Leonarduzzi R, Bouchaud J-P, Mallat S. Scale dependencies and self-similar models with wavelet scattering spectra. Appl Comput Harmon Anal. 2025;75:101724.","journal-title":"Appl Comput Harmon Anal"},{"key":"834_CR17","doi-asserted-by":"publisher","first-page":"4762","DOI":"10.1118\/1.3480506","volume":"37","author":"J Wen","year":"2010","unstructured":"Wen J, Kong L. A wavelet\u2010based SPECT reconstruction algorithm for nonuniformly attenuated Radon transform. Med Phys. 2010;37:4762\u20137.","journal-title":"Med Phys"},{"key":"834_CR18","doi-asserted-by":"publisher","first-page":"189","DOI":"10.4103\/0971-6203.121197","volume":"38","author":"MN Asl","year":"2013","unstructured":"Asl MN, Sadremomtaz A, Bitarafan-Rajabi A. Evaluation of six scatter correction methods based on spectral analysis in 99mTc SPECT imaging using SIMIND Monte Carlo simulation. J Med Phys. 2013;38:189\u201397.","journal-title":"J Med Phys"},{"key":"834_CR19","first-page":"881","volume":"131","author":"A Houimli","year":"2022","unstructured":"Houimli A, Mhamed I, Letaief B, Ben-Sellem D. Fast and accurate thoracic SPECT image reconstruction. Comput Model Eng Sci. 2022;131:881\u2013904.","journal-title":"Comput Model Eng Sci"},{"key":"834_CR20","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-023-00598-9","volume":"10","author":"Y Jia","year":"2023","unstructured":"Jia Y, Li Z, Akhavanallaf A, Fessler JA, Dewaraja YK. 90Y SPECT scatter estimation and voxel dosimetry in radioembolization using a unified deep learning framework. EJNMMI Phys. 2023;10:82.","journal-title":"EJNMMI Phys"},{"key":"834_CR21","first-page":"20669","volume":"34","author":"W Ha","year":"2021","unstructured":"Ha W, Singh C, Lanusse F, Upadhyayula S, Yu B. Adaptive wavelet distillation from neural networks through interpretations. Adv Neural Inf Process Syst. 2021;34:20669\u201382.","journal-title":"Adv Neural Inf Process Syst"},{"key":"834_CR22","doi-asserted-by":"publisher","first-page":"2956","DOI":"10.1007\/s00259-020-04840-9","volume":"47","author":"H Xiang","year":"2020","unstructured":"Xiang H, Lim H, Fessler JA, Dewaraja YK. A deep neural network for fast and accurate scatter estimation in quantitative SPECT\/CT under challenging scatter conditions. Eur J Nucl Med Mol Imaging. 2020;47:2956\u201367.","journal-title":"Eur J Nucl Med Mol Imaging"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-026-00834-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00834-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00834-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T09:46:31Z","timestamp":1773222391000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40658-026-00834-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,7]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["834"],"URL":"https:\/\/doi.org\/10.1186\/s40658-026-00834-y","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,7]]},"assertion":[{"value":"16 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"23"}}