{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T22:34:09Z","timestamp":1787610849368,"version":"build-2736575974"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T00:00:00Z","timestamp":1784073600000},"content-version":"vor","delay-in-days":55,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"DOI":"10.1186\/s40658-026-00876-2","type":"journal-article","created":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T12:55:02Z","timestamp":1779368102000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Acquisition time\/dose reduction in pediatric PET imaging using patch-based deep learning"],"prefix":"10.1186","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7466-7025","authenticated-orcid":false,"given":"Chenyang","family":"Han","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1431-4054","authenticated-orcid":false,"given":"Andrew T.","family":"Trout","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-5391-4521","authenticated-orcid":false,"given":"Andi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6794-9200","authenticated-orcid":false,"given":"Joseph G.","family":"Meier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8772-4770","authenticated-orcid":false,"given":"Vinicius P. V.","family":"Alves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"MacLean","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6624-6140","authenticated-orcid":false,"given":"Nadeen","family":"Abu Ata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1986-447X","authenticated-orcid":false,"given":"Yinan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0477-8624","authenticated-orcid":false,"given":"Susan E.","family":"Sharp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8793-6607","authenticated-orcid":false,"given":"Christopher G.","family":"Anton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8961-138X","authenticated-orcid":false,"given":"Jing","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,21]]},"reference":[{"key":"876_CR1","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1007\/s00247-003-1112-5","volume":"34","author":"BL Shulkin","year":"2004","unstructured":"Shulkin BL. PET imaging in pediatric oncology. Pediatr Radiol. 2004;34:199\u2013204. https:\/\/doi.org\/10.1007\/s00247-003-1112-5.","journal-title":"Pediatr Radiol"},{"key":"876_CR2","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1053\/j.semnuclmed.2007.04.001","volume":"37","author":"H Jadvar","year":"2007","unstructured":"Jadvar H, Connolly LP, Fahey FH, Shulkin BL. PET and PET\/CT in pediatric oncology. Semin Nucl Med. 2007;37:316\u201331. https:\/\/doi.org\/10.1053\/j.semnuclmed.2007.04.001.","journal-title":"Semin Nucl Med"},{"key":"876_CR3","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1007\/s00247-010-1794-4","volume":"40","author":"MJ Gelfand","year":"2010","unstructured":"Gelfand MJ, Sharp SE, Treves ST, Fahey FH, Parisi MT, Alessio AM. Estimated cumulative radiation dose from PET\/CT in children with malignancies. Pediatr Radiol. 2010;40:1712\u20133. https:\/\/doi.org\/10.1007\/s00247-010-1794-4.","journal-title":"Pediatr Radiol"},{"key":"876_CR4","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1007\/s00247-016-3720-x","volume":"47","author":"B Johnsen","year":"2017","unstructured":"Johnsen B, Fasmer KE, Boye K, Rosendahl K, Trovik C, Biermann M, et al. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005\u20132012. Pediatr Radiol. 2017;47:82\u20138. https:\/\/doi.org\/10.1007\/s00247-016-3720-x.","journal-title":"Pediatr Radiol"},{"key":"876_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2020.109412","volume":"168","author":"M Alkhorayef","year":"2021","unstructured":"Alkhorayef M. Effective radiation doses in pediatric PET\/CT examinations: pilot study. Appl Radiat Isot. 2021;168:109412. https:\/\/doi.org\/10.1016\/j.apradiso.2020.109412.","journal-title":"Appl Radiat Isot"},{"key":"876_CR6","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph13111057","volume":"13","author":"KR Kutanzi","year":"2016","unstructured":"Kutanzi KR, Lumen A, Koturbash I, Miousse IR. Pediatric exposures to ionizing radiation: carcinogenic considerations. Int J Environ Res Public Health. 2016;13:1057. https:\/\/doi.org\/10.3390\/ijerph13111057.","journal-title":"Int J Environ Res Public Health"},{"key":"876_CR7","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1053\/j.semnuclmed.2017.01.002","volume":"47","author":"MT Parisi","year":"2017","unstructured":"Parisi MT, Bermo MS, Alessio AM, Sharp SE, Gelfand MJ, Shulkin BL. Optimization of pediatric PET\/CT. Semin Nucl Med. 2017;47:258\u201374. https:\/\/doi.org\/10.1053\/j.semnuclmed.2017.01.002.","journal-title":"Semin Nucl Med"},{"key":"876_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s41824-021-00096-0","volume":"5","author":"C Hornnes","year":"2021","unstructured":"Hornnes C, Loft A, H\u00f8jgaard L, Andersen FL. The effect of reduced scan time on response assessment FDG-PET\/CT imaging using Deauville score in patients with lymphoma. Eur J Hybrid Imaging. 2021;5:2. https:\/\/doi.org\/10.1186\/s41824-021-00096-0.","journal-title":"Eur J Hybrid Imaging"},{"key":"876_CR9","doi-asserted-by":"publisher","first-page":"1962","DOI":"10.2967\/jnumed.121.263626","volume":"63","author":"M Reichkendler","year":"2022","unstructured":"Reichkendler M, Andersen FL, Borgwardt L, Nygaard U, Albrecht-Beste E, Andersen KF, et al. A long axial field of view enables PET\/CT in toddler without sedation. J Nucl Med. 2022;63:1962\u20131962. https:\/\/doi.org\/10.2967\/jnumed.121.263626.","journal-title":"J Nucl Med"},{"key":"876_CR10","doi-asserted-by":"publisher","first-page":"952","DOI":"10.2214\/AJR.22.27894","volume":"219","author":"VPV Alves","year":"2022","unstructured":"Alves VPV, Brady S, Ata NA, Li Y, MacLean J, Zhang B, et al. Simulated reduced-count whole-body FDG PET: evaluation in children and young adults imaged on a digital PET scanner. AJR Am J Roentgenol. 2022;219:952\u201361. https:\/\/doi.org\/10.2214\/AJR.22.27894.","journal-title":"AJR Am J Roentgenol"},{"key":"876_CR11","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1109\/TRPMS.2023.3349194","volume":"8","author":"A Bousse","year":"2024","unstructured":"Bousse A, Kandarpa VSS, Shi K, Gong K, Lee JS, Liu C, et al. A review on low-dose emission tomography post-reconstruction denoising with neural network approaches. IEEE Trans Radiat Plasma Med Sci. 2024;8:333\u201347. https:\/\/doi.org\/10.1109\/TRPMS.2023.3349194.","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"876_CR12","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.neucom.2017.06.048","volume":"267","author":"L Xiang","year":"2017","unstructured":"Xiang L, Qiao Y, Nie D, An L, Lin W, Wang Q, et al. Deep auto-context convolutional neural networks for standard-dose PET image estimation from low-dose PET\/MRI. Neurocomputing. 2017;267:406\u201316. https:\/\/doi.org\/10.1016\/j.neucom.2017.06.048.","journal-title":"Neurocomputing"},{"key":"876_CR13","doi-asserted-by":"publisher","first-page":"3555","DOI":"10.1002\/mp.13626","volume":"46","author":"J Ouyang","year":"2019","unstructured":"Ouyang J, Chen KT, Gong E, Pauly J, Zaharchuk G. Ultra-low-dose PET reconstruction using generative adversarial network with feature matching and task-specific perceptual loss. Med Phys. 2019;46:3555\u201364. https:\/\/doi.org\/10.1002\/mp.13626.","journal-title":"Med Phys"},{"key":"876_CR14","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1109\/TRPMS.2018.2877644","volume":"3","author":"K Gong","year":"2019","unstructured":"Gong K, Guan J, Liu C-C, Qi J. PET image denoising using a deep neural network through fine tuning. IEEE Trans Radiat Plasma Med Sci. 2019;3:153\u201361. https:\/\/doi.org\/10.1109\/TRPMS.2018.2877644.","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"876_CR15","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1007\/s00259-023-06417-8","volume":"51","author":"K Gong","year":"2024","unstructured":"Gong K, Johnson K, El Fakhri G, Li Q, Pan T. PET image denoising based on denoising diffusion probabilistic model. Eur J Nucl Med Mol Imaging. 2024;51:358\u201368. https:\/\/doi.org\/10.1007\/s00259-023-06417-8.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"876_CR16","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1007\/s00247-018-4277-7","volume":"49","author":"MM Moore","year":"2019","unstructured":"Moore MM, Slonimsky E, Long AD, Sze RW, Iyer RS. Machine learning concepts, concerns and opportunities for a pediatric radiologist. Pediatr Radiol. 2019;49:509\u201316. https:\/\/doi.org\/10.1007\/s00247-018-4277-7.","journal-title":"Pediatr Radiol"},{"key":"876_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinimag.2024.110093","volume":"107","author":"P Debnath","year":"2024","unstructured":"Debnath P, Trout AT. Patient factors affecting 18F FDG uptake in children. Clin Imaging. 2024;107:110093. https:\/\/doi.org\/10.1016\/j.clinimag.2024.110093.","journal-title":"Clin Imaging"},{"key":"876_CR18","doi-asserted-by":"publisher","first-page":"5830","DOI":"10.1002\/mp.15867","volume":"49","author":"J Liu","year":"2022","unstructured":"Liu J, Ren S, Wang R, Mirian N, Tsai Y-J, Kulon M, et al. Virtual high-count PET image generation using a deep learning method. Med Phys. 2022;49:5830\u201340. https:\/\/doi.org\/10.1002\/mp.15867.","journal-title":"Med Phys"},{"key":"876_CR19","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/s00259-023-06422-x","volume":"51","author":"Z Huang","year":"2023","unstructured":"Huang Z, Li W, Wu Y, Guo N, Yang L, Zhang N, et al. Short-axis PET image quality improvement based on a uEXPLORER total-body PET system through deep learning. Eur J Nucl Med Mol Imaging. 2023;51:27\u201339. https:\/\/doi.org\/10.1007\/s00259-023-06422-x.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"876_CR20","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.220246","volume":"5","author":"Y- R (Joyce) Wang","year":"2023","unstructured":"Wang Y- R (Joyce), Qu L, Sheybani ND, Luo X, Wang J, Hawk KE, et al. AI transformers for radiation dose reduction in serial whole-body PET scans. Radiology AI. 2023;5:e220246. https:\/\/doi.org\/10.1148\/ryai.220246.","journal-title":"Radiology AI"},{"key":"876_CR21","doi-asserted-by":"publisher","DOI":"10.1186\/s13640-017-0203-4","volume":"2017","author":"MH Alkinani","year":"2017","unstructured":"Alkinani MH, El-Sakka MR. Patch-based models and algorithms for image denoising: a comparative review between patch-based images denoising methods for additive noise reduction. EURASIP J Image Video Process. 2017;2017:58. https:\/\/doi.org\/10.1186\/s13640-017-0203-4.","journal-title":"EURASIP J Image Video Process"},{"key":"876_CR22","doi-asserted-by":"publisher","first-page":"2484","DOI":"10.1364\/OPTCON.497110","volume":"2","author":"F Nawreen","year":"2023","unstructured":"Nawreen F, Halder KK, Tahtali M, Anavatti SG. Stabilization of turbulence-degraded video using patch-based reference frame. Opt Continuum. 2023;2:2484\u201399. https:\/\/doi.org\/10.1364\/OPTCON.497110.","journal-title":"Opt Continuum"},{"key":"876_CR23","doi-asserted-by":"publisher","first-page":"1765","DOI":"10.1007\/s11548-016-1434-z","volume":"11","author":"D Karimi","year":"2016","unstructured":"Karimi D, Ward RK. Patch-based models and algorithms for image processing: a review of the basic principles and methods, and their application in computed tomography. Int J CARS. 2016;11:1765\u201377. https:\/\/doi.org\/10.1007\/s11548-016-1434-z.","journal-title":"Int J CARS"},{"key":"876_CR24","doi-asserted-by":"publisher","first-page":"1340","DOI":"10.1002\/mrm.26205","volume":"77","author":"J Klosowski","year":"2017","unstructured":"Klosowski J, Frahm J. Image denoising for real-time MRI. Magn Reson Med. 2017;77:1340\u201352. https:\/\/doi.org\/10.1002\/mrm.26205.","journal-title":"Magn Reson Med"},{"key":"876_CR25","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.cam.2017.01.022","volume":"329","author":"R Hao","year":"2018","unstructured":"Hao R, Su Z. A patch-based low-rank tensor approximation model for multiframe image denoising. J Comput Appl Math. 2018;329:125\u201333. https:\/\/doi.org\/10.1016\/j.cam.2017.01.022.","journal-title":"J Comput Appl Math"},{"key":"876_CR26","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1109\/TMI.2018.2803681","volume":"37","author":"B Yang","year":"2018","unstructured":"Yang B, Ying L, Tang J. Artificial neural network enhanced Bayesian PET image reconstruction. IEEE Trans Med Imaging. 2018;37:1297\u2013309. https:\/\/doi.org\/10.1109\/TMI.2018.2803681.","journal-title":"IEEE Trans Med Imaging"},{"key":"876_CR27","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab8687","volume":"65","author":"X Wang","year":"2020","unstructured":"Wang X, Yang B, Moody JB, Tang J. Improved myocardial perfusion PET imaging using artificial neural networks. Phys Med Biol. 2020;65:145010. https:\/\/doi.org\/10.1088\/1361-6560\/ab8687.","journal-title":"Phys Med Biol"},{"key":"876_CR28","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad0535","volume":"68","author":"A Li","year":"2023","unstructured":"Li A, Yang B, Naganawa M, Fontaine K, Toyonaga T, Carson RE, et al. Dose reduction in dynamic synaptic vesicle glycoprotein 2A PET imaging using artificial neural networks. Phys Med Biol. 2023;68:245006. https:\/\/doi.org\/10.1088\/1361-6560\/ad0535.","journal-title":"Phys Med Biol"},{"key":"876_CR29","doi-asserted-by":"publisher","first-page":"99","DOI":"10.2967\/jnumed.120.254110","volume":"62","author":"R Vali","year":"2021","unstructured":"Vali R, Alessio A, Balza R, Borgwardt L, Bar-Sever Z, Czachowski M, et al. SNMMI procedure standard\/EANM practice guideline on pediatric 18F-FDG PET\/CT for oncology 1.0. J Nucl Med. 2021;62:99\u2013110. https:\/\/doi.org\/10.2967\/jnumed.120.254110.","journal-title":"J Nucl Med"},{"key":"876_CR30","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-023-00527-w","volume":"10","author":"K Miwa","year":"2023","unstructured":"Miwa K, Yoshii T, Wagatsuma K, Nezu S, Kamitaka Y, Yamao T, et al. Impact of \u03b3 factor in the penalty function of Bayesian penalized likelihood reconstruction (Q.Clear) to achieve high-resolution PET images. EJNMMI Phys. 2023;10:4. https:\/\/doi.org\/10.1186\/s40658-023-00527-w.","journal-title":"EJNMMI Phys"},{"key":"876_CR31","unstructured":"National Electrical Manufacturers Association. NEMA standards publication NU 2\u20132018: performance measurements of positron emission tomographs (PET). Rosslyn; 2018."},{"key":"876_CR32","doi-asserted-by":"publisher","first-page":"8","DOI":"10.2214\/AJR.14.13022","volume":"204","author":"AS Phelps","year":"2015","unstructured":"Phelps AS, Naeger DM, Courtier JL, Lambert JW, Marcovici PA, Villanueva-Meyer JE, et al. Pairwise comparison versus Likert scale for biomedical image assessment. AJR Am J Roentgenol. 2015;204:8\u201314. https:\/\/doi.org\/10.2214\/AJR.14.13022.","journal-title":"AJR Am J Roentgenol"},{"key":"876_CR33","doi-asserted-by":"publisher","first-page":"2026","DOI":"10.1109\/78.533723","volume":"44","author":"AO Hero","year":"1996","unstructured":"Hero AO, Fessler JA, Usman M. Exploring estimator bias-variance tradeoffs using the uniform CR bound. IEEE Trans Signal Process. 1996;44:2026\u201341. https:\/\/doi.org\/10.1109\/78.533723.","journal-title":"IEEE Trans Signal Process"},{"key":"876_CR34","first-page":"109","volume":"62","author":"Q Liu","year":"2021","unstructured":"Liu Q, Liu H, Niloufar M, Ren S, Liu C. The impact of noise level mismatch between training and testing images for deep learning-based PET denoising. Journal of Nuclear Medicine. Soc Nuclear Med. 2021;62:109\u2013109.","journal-title":"Soc Nuclear Med"},{"key":"876_CR35","volume-title":"Regression modeling strategies","author":"H Frank","year":"2015","unstructured":"Frank H. Regression modeling strategies. 2nd ed. Berlin: Springer; 2015.","edition":"2"},{"key":"876_CR36","doi-asserted-by":"publisher","first-page":"3736","DOI":"10.1109\/TIP.2006.881969","volume":"15","author":"M Elad","year":"2006","unstructured":"Elad M, Aharon M. Image denoising via sparse and redundant representations over learned dictionaries. IEEE Trans Image Process. 2006;15:3736\u201345. https:\/\/doi.org\/10.1109\/TIP.2006.881969.","journal-title":"IEEE Trans Image Process"},{"key":"876_CR37","doi-asserted-by":"publisher","first-page":"2405","DOI":"10.1007\/s00259-020-05167-1","volume":"48","author":"A Sanaat","year":"2021","unstructured":"Sanaat A, Shiri I, Arabi H, Mainta I, Nkoulou R, Zaidi H. Deep learning-assisted ultra-fast\/low-dose whole-body PET\/CT imaging. Eur J Nucl Med Mol Imaging. 2021;48:2405\u201315. https:\/\/doi.org\/10.1007\/s00259-020-05167-1.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"876_CR38","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-022-00431-9","volume":"9","author":"Y Xing","year":"2022","unstructured":"Xing Y, Qiao W, Wang T, Wang Y, Li C, Lv Y, et al. Deep learning-assisted PET imaging achieves fast scan\/low-dose examination. EJNMMI Phys. 2022;9:7. https:\/\/doi.org\/10.1186\/s40658-022-00431-9.","journal-title":"EJNMMI Phys"},{"key":"876_CR39","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-023-00605-z","volume":"11","author":"Q Zhang","year":"2024","unstructured":"Zhang Q, Hu Y, Zhou C, Zhao Y, Zhang N, Zhou Y, et al. Reducing pediatric total-body PET\/CT imaging scan time with multimodal artificial intelligence technology. EJNMMI Phys. 2024;11:1. https:\/\/doi.org\/10.1186\/s40658-023-00605-z.","journal-title":"EJNMMI Phys"},{"key":"876_CR40","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-023-00607-x","volume":"11","author":"H Yang","year":"2024","unstructured":"Yang H, Chen S, Qi M, Chen W, Kong Q, Zhang J, et al. Investigation of PET image quality with acquisition time\/bed and enhancement of lesion quantification accuracy through deep progressive learning. EJNMMI Phys. 2024;11:7. https:\/\/doi.org\/10.1186\/s40658-023-00607-x.","journal-title":"EJNMMI Phys"},{"key":"876_CR41","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.2020200137","volume":"3","author":"J Yang","year":"2021","unstructured":"Yang J, Sohn JH, Behr SC, Gullberg GT, Seo Y. CT-less direct correction of attenuation and scatter in the image space using deep learning for whole-body FDG PET: potential benefits and pitfalls. Radiol Artif Intell. 2021;3:e200137. https:\/\/doi.org\/10.1148\/ryai.2020200137.","journal-title":"Radiol Artif Intell"},{"key":"876_CR42","doi-asserted-by":"publisher","DOI":"10.1186\/s12885-022-09993-4","volume":"22","author":"P Fragoso Costa","year":"2022","unstructured":"Fragoso Costa P, Jentzen W, Brahmer A, Mavroeidi I-A, Zarrad F, Umutlu L, et al. Phantom-based acquisition time and image reconstruction parameter optimisation for oncologic FDG PET\/CT examinations using a digital system. BMC Cancer. 2022;22:899. https:\/\/doi.org\/10.1186\/s12885-022-09993-4.","journal-title":"BMC Cancer"},{"key":"876_CR43","doi-asserted-by":"publisher","first-page":"21","DOI":"10.2967\/jnmt.114.147215","volume":"43","author":"D Koopman","year":"2015","unstructured":"Koopman D, van Dalen JA, Lagerweij MCM, Arkies H, de Boer J, Oostdijk AHJ, et al. Improving the detection of small lesions using a state-of-the-art time-of-flight PET\/CT system and small-voxel reconstructions. J Nucl Med Technol. 2015;43:21\u20137. https:\/\/doi.org\/10.2967\/jnmt.114.147215.","journal-title":"J Nucl Med Technol"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-026-00876-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00876-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00876-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T01:43:13Z","timestamp":1784079793000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40658-026-00876-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,21]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["876"],"URL":"https:\/\/doi.org\/10.1186\/s40658-026-00876-2","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,21]]},"assertion":[{"value":"30 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was conducted in accordance with the principles of the Declaration of Helsinki. Ethics approval was granted by the Institutional Review Board of Cincinnati Children\u2019s Hospital Medical Center. A waiver of the need to document written informed consent from all participants was obtained.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"AT previously consulted for GE HealthCare, and that engagement has now concluded. AT is also a co-investigator on a research study that has received grant support from GE HealthCare. Both roles are related to PET imaging. No fiduciary responsibility to GE HealthCare. The other authors have no relevant financial or non-financial interests to disclose.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"75"}}