{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T09:20:43Z","timestamp":1780392043388,"version":"3.54.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T00:00:00Z","timestamp":1776643200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:00:00Z","timestamp":1780358400000},"content-version":"vor","delay-in-days":43,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009232","name":"University of Debrecen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009232","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      Unilateral condylar hyperplasia (UCH) is a rare mandibular growth disorder in which accurate assessment of condylar metabolic activity is essential for surgical decision-making. Quantitative\n                      <jats:sup>99m<\/jats:sup>\n                      Tc-methylene diphosphonate (MDP) SPECT\/CT is commonly used for this purpose; however, CT-based attenuation correction (CTAC) increases radiation exposure and may be affected by registration errors. Artificial intelligence (AI)-generated synthetic CT (SyCT) has been proposed as a CT-independent alternative. This study aimed to evaluate the agreement between SyCT-based attenuation correction (SyCTAC) and conventional CTAC in quantitative SPECT imaging of UCH.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This retrospective study included 14 patients with UCH who underwent\n                      <jats:sup>99m<\/jats:sup>\n                      Tc-MDP SPECT\/CT. SPECT images were reconstructed with identical parameters using either CTAC or AI-generated SyCTAC. Spherical volumes of interest were placed over both mandibular condyles and the clivus, and maximum and mean standardized uptake values were measured. Relative uptake fractions normalized to the summed condylar activity were calculated for the affected side, while condylar uptake normalized to the clivus was evaluated for both sides. Agreement between CTAC- and SyCTAC-derived indices was assessed using Bland\u2013Altman analysis and linear mixed-effects models.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Visual evaluation revealed no relevant differences in image quality between the two reconstructions. Relative uptake fractions normalized to the summed condylar activity showed good agreement between methods. Clivus-normalized ratios demonstrated a small positive bias.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>AI-generated SyCT provides attenuation correction comparable to CTAC for clinically relevant relative condylar uptake assessment in UCH, supporting its use as a low-radiation alternative for quantitative mandibular SPECT imaging.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40658-026-00879-z","type":"journal-article","created":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T17:38:39Z","timestamp":1776706719000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["AI-based synthetic CT attenuation correction enables reliable quantitative SPECT in unilateral condylar hyperplasia"],"prefix":"10.1186","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-8412-0203","authenticated-orcid":false,"given":"Anna Rebeka","family":"Kov\u00e1cs","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enik\u0151 Fanni","family":"Juh\u00e1sz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9397-2870","authenticated-orcid":false,"given":"P\u00e9ter","family":"Czina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c1d\u00e1m","family":"Budai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5797-9625","authenticated-orcid":false,"given":"J\u00f3zsef","family":"Varga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Borb\u00e1la","family":"Husztik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7163-5228","authenticated-orcid":false,"given":"\u00c1kos","family":"Kov\u00e1cs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melinda","family":"Szolikov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00f3bert","family":"Boda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kincs\u0151 S\u00e1ra","family":"Kov\u00e1cs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ildik\u00f3","family":"Garai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0608-7704","authenticated-orcid":false,"given":"S\u00e1ndor Krist\u00f3f","family":"Barna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,20]]},"reference":[{"key":"879_CR1","doi-asserted-by":"publisher","unstructured":"Lin Z, Xue Q, Lin R, Yao S, Miao W. Reference values of mandibular condylar growth activity: a study of SUVmax with quantitative bone SPECT\/CT. Nucl Med Commun. 2022;43:152\u2013158. https:\/\/doi.org\/10.1097\/MNM.0000000000001507.","DOI":"10.1097\/MNM.0000000000001507"},{"key":"879_CR2","doi-asserted-by":"publisher","unstructured":"Olate S, Ravelo V, Alister JP, Netto HD, Haidar ZS, Sacco R. Early treatment of unilateral condylar hyperplasia in adolescents: preliminary results. J Clin Med. 2023;12:3408. https:\/\/doi.org\/10.3390\/jcm12103408.","DOI":"10.3390\/jcm12103408"},{"key":"879_CR3","doi-asserted-by":"publisher","first-page":"102129","DOI":"10.1016\/j.jormas.2024.102129","volume":"126","author":"E Ergezen","year":"2025","unstructured":"Ergezen E, Salyut A, Akdeniz SS, \u00c7ubuk S. Characterizing the unseen: clinical and radiographic perspectives on unilateral condylar hyperplasia. J Stomatol Oral Maxillofac Surg. 2025;126:102129. https:\/\/doi.org\/10.1016\/j.jormas.2024.102129.","journal-title":"J Stomatol Oral Maxillofac Surg"},{"key":"879_CR4","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ijom.2022.08.002","volume":"52","author":"LHE Karssemakers","year":"2023","unstructured":"Karssemakers LHE, Nolte JW, Rehmann C, Raijmakers PG, Becking AG. Diagnostic performance of SPECT\u2013CT imaging in unilateral condylar hyperplasia. Int J Oral Maxillofac Surg. 2023;52:199\u2013204. https:\/\/doi.org\/10.1016\/j.ijom.2022.08.002.","journal-title":"Int J Oral Maxillofac Surg"},{"key":"879_CR5","doi-asserted-by":"publisher","unstructured":"Anzola LK, Venegas N, Jaramillo MC, Moreno S, Hinojosa M, Amador E, et al. Diagnostic efficacy of bone SPECT techniques in differentiating unilateral and bilateral condylar hyperplasia. Diagnostics. 2024;14:2548. https:\/\/doi.org\/10.3390\/diagnostics14222548.","DOI":"10.3390\/diagnostics14222548"},{"key":"879_CR6","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1007\/s00259-022-06028-9","volume":"50","author":"JC Dickson","year":"2023","unstructured":"Dickson JC, Armstrong IS, Gabi\u00f1a PM, Denis-Bacelar AM, Krizsan AK, Gear JM, et al. EANM practice guideline for quantitative SPECT-CT. Eur J Nucl Med Mol Imaging. 2023;50:980\u201395. https:\/\/doi.org\/10.1007\/s00259-022-06028-9.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"879_CR7","doi-asserted-by":"publisher","unstructured":"Apostolopoulos ID, Papandrianos N\u0399, Papageorgiou EI, Apostolopoulos DJ. A review on SPECT myocardial perfusion imaging attenuation correction using deep learning. Appl Sci. 2025;15:11287. https:\/\/doi.org\/10.3390\/app152011287.","DOI":"10.3390\/app152011287"},{"key":"879_CR8","doi-asserted-by":"publisher","first-page":"5578","DOI":"10.1007\/s00330-024-10647-1","volume":"34","author":"W Li","year":"2024","unstructured":"Li W, Huang Z, Chen Z, Jiang Y, Zhou C, Zhang X, et al. Learning CT-free attenuation-corrected total-body PET images through deep learning. Eur Radiol. 2024;34:5578\u201387. https:\/\/doi.org\/10.1007\/s00330-024-10647-1.","journal-title":"Eur Radiol"},{"key":"879_CR9","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.jmir.2021.10.008","volume":"53","author":"N Ben-Rejeb","year":"2022","unstructured":"Ben-Rejeb N, Ben-Sellem D. Estimation of additional dosimetry from low-dose CT scan to 99mTc-HMDP SPECT\/CT. J Med Imaging Radiat Sci. 2022;53:87\u201392. https:\/\/doi.org\/10.1016\/j.jmir.2021.10.008.","journal-title":"J Med Imaging Radiat Sci"},{"key":"879_CR10","doi-asserted-by":"publisher","unstructured":"Mendon\u00e7a RP, Estrela C, Bueno MR, Carvalho TCASG, Estrela LRA, Chilvarquer I. Principles of radiological protection and application of ALARA, ALADA, and ALADAIP: a critical review. Braz Oral Res. 2025;39:e14. https:\/\/doi.org\/10.1590\/1807-3107bor-2025.vol39.014.","DOI":"10.1590\/1807-3107bor-2025.vol39.014"},{"key":"879_CR11","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.radi.2024.11.002","volume":"31","author":"M Miyai","year":"2025","unstructured":"Miyai M, Fukui R, Nakashima M, Hasegawa D, Goto S. Accuracy of deep learning-based attenuation correction in 99mTc-GSA SPECT\/CT hepatic imaging. Radiography. 2025;31:112\u20137. https:\/\/doi.org\/10.1016\/j.radi.2024.11.002.","journal-title":"Radiography"},{"key":"879_CR12","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1186\/s40658-024-00686-4","volume":"11","author":"K Kwon","year":"2024","unstructured":"Kwon K, Oh D, Kim JH, Yoo J, Lee WW. Deep-learning-based attenuation map generation in kidney single photon emission computed tomography. EJNMMI Phys. 2024;11:84. https:\/\/doi.org\/10.1186\/s40658-024-00686-4.","journal-title":"EJNMMI Phys"},{"key":"879_CR13","doi-asserted-by":"publisher","unstructured":"Lassmann M, Treves ST, Group F the EPDHW. Paediatric radiopharmaceutical administration: harmonization of the 2007 EANM paediatric dosage card (version 1.5.2008) and the 2010 North American consensus guidelines. Eur J Nucl Med Mol Imaging. 2014;41:1036\u201341. https:\/\/doi.org\/10.1007\/s00259-014-2731-9","DOI":"10.1007\/s00259-014-2731-9"},{"key":"879_CR14","doi-asserted-by":"publisher","first-page":"167003","DOI":"10.1016\/j.nima.2022.167003","volume":"1039","author":"A Kovacs","year":"2022","unstructured":"Kovacs A, Bukki T, Legradi G, Meszaros NJ, Kovacs GZ, Prajczer P, et al. Robustness analysis of denoising neural networks for bone scintigraphy. Nucl Instrum Methods Phys Res A. 2022;1039:167003. https:\/\/doi.org\/10.1016\/j.nima.2022.167003.","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"879_CR15","doi-asserted-by":"publisher","unstructured":"Csikos C, Barna S, Kov\u00e1cs \u00c1, Czina P, Budai \u00c1, Szolikov\u00e1 M, et al. AI-based noise-reduction filter for whole-body planar bone scintigraphy reliably improves low-count images. Diagnostics. 2024;14:2686. https:\/\/doi.org\/10.3390\/diagnostics14232686.","DOI":"10.3390\/diagnostics14232686"},{"key":"879_CR16","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s40658-023-00541-y","volume":"10","author":"AK Krizsan","year":"2023","unstructured":"Krizsan AK, Kukuts K, Al-Muhanna W, Szoboszlai Z, Balazs L, Szabo B, et al. Performance evaluation of a novel multi-pinhole collimator on triple-NaI-detector SPECT\/CT for dedicated myocardial imaging. EJNMMI Phys. 2023;10:24. https:\/\/doi.org\/10.1186\/s40658-023-00541-y.","journal-title":"EJNMMI Phys"},{"key":"879_CR17","doi-asserted-by":"publisher","first-page":"6624","DOI":"10.1038\/s41598-024-57152-5","volume":"14","author":"FLH Fredensborg","year":"2024","unstructured":"Fredensborg FLH, Thilsing-Hansen K, Simonsen JA, Grupe P, Farahani ZA, Andersen CW, et al. Dynamic multi-pinhole collimated brain SPECT of Parkinson\u2019s disease by [123I]FP-CIT: a feasibility study of fSPECT. Sci Rep. 2024;14:6624. https:\/\/doi.org\/10.1038\/s41598-024-57152-5.","journal-title":"Sci Rep"},{"key":"879_CR18","doi-asserted-by":"publisher","first-page":"165015","DOI":"10.1088\/1361-6560\/ab9067","volume":"65","author":"K Tecklenburg","year":"2020","unstructured":"Tecklenburg K, Forg\u00e1cs A, Apostolova I, Lehnert W, Klutmann S, Csirik J, et al. Performance evaluation of a novel multi-pinhole collimator for dopamine transporter SPECT. Phys Med Biol. 2020;65:165015. https:\/\/doi.org\/10.1088\/1361-6560\/ab9067.","journal-title":"Phys Med Biol"},{"key":"879_CR19","doi-asserted-by":"publisher","unstructured":"Urb\u00e1n S, Meyer C, Dahlbom M, Farkas I, Sipka G, Besenyi Z, et al. Radiation dosimetry of Tc99m-PSMA I&S: a single-center prospective study. J Nucl Med 2020;jnumed.120.253476. https:\/\/doi.org\/10.2967\/jnumed.120.253476","DOI":"10.2967\/jnumed.120.253476"},{"key":"879_CR20","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1186\/s12874-020-01022-x","volume":"20","author":"RA Parker","year":"2020","unstructured":"Parker RA, Scott C, In\u00e1cio V, Stevens NT. Using multiple agreement methods for continuous repeated measures data: a tutorial for practitioners. BMC Med Res Methodol. 2020;20:154. https:\/\/doi.org\/10.1186\/s12874-020-01022-x.","journal-title":"BMC Med Res Methodol"},{"key":"879_CR21","doi-asserted-by":"publisher","unstructured":"Jahangir R, Kamali-Asl A, Arabi H, Zaidi H. Strategies for deep learning-based attenuation and scatter correction of brain 18F-FDG PET images in the image domain. Med Phys. 2024;51:870\u201380. https:\/\/doi.org\/10.1002\/mp.16914","DOI":"10.1002\/mp.16914"},{"key":"879_CR22","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s40658-023-00536-9","volume":"10","author":"K Kwon","year":"2023","unstructured":"Kwon K, Hwang D, Oh D, Kim JH, Yoo J, Lee JS, et al. CT-free quantitative SPECT for automatic evaluation of %thyroid uptake based on deep-learning. EJNMMI Phys. 2023;10:20. https:\/\/doi.org\/10.1186\/s40658-023-00536-9.","journal-title":"EJNMMI Phys"},{"key":"879_CR23","doi-asserted-by":"publisher","unstructured":"Prieto Canalejo MA, Palau San Pedro A, Geronazzo R, Minsky DM, Ju\u00e1rez-Orozco LE, Nam\u00edas M. Synthetic attenuation correction maps for SPECT imaging using deep learning: a study on myocardial perfusion imaging. Diagnostics. 2023;13:2214. https:\/\/doi.org\/10.3390\/diagnostics13132214.","DOI":"10.3390\/diagnostics13132214"},{"key":"879_CR24","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s12880-025-01570-y","volume":"25","author":"P Yang","year":"2025","unstructured":"Yang P, Zhang Z, Wei J, Jiang L, Yu L, Cai H, et al. Deep learning-based CT-free attenuation correction for cardiac SPECT: a new approach. BMC Med Imaging. 2025;25:38. https:\/\/doi.org\/10.1186\/s12880-025-01570-y.","journal-title":"BMC Med Imaging"},{"key":"879_CR25","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.122.264429","author":"AD Shanbhag","year":"2022","unstructured":"Shanbhag AD, Miller RJH, Pieszko K, Lemley M, Kavanagh P, Feher A, et al. Deep learning-based attenuation correction improves diagnostic accuracy of cardiac SPECT. J Nuclear Med Soc Nuclear Med. 2022. https:\/\/doi.org\/10.2967\/jnumed.122.264429.","journal-title":"J Nuclear Med Soc Nuclear Med"},{"key":"879_CR26","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.phro.2022.04.005","volume":"22","author":"S Oonsiri","year":"2022","unstructured":"Oonsiri S, Kitpanit S, Kannarunimit D, Chakkabat C, Lertbutsayanukul C, Prayongrat A. Comparison of intensity modulated proton therapy beam configurations for treating thoracic esophageal cancer. Phys Imaging Radiat Oncol. 2022;22:51\u20136. https:\/\/doi.org\/10.1016\/j.phro.2022.04.005.","journal-title":"Phys Imaging Radiat Oncol"},{"key":"879_CR27","doi-asserted-by":"publisher","unstructured":"Montgomery ME, Andersen FL, d\u2019Este SH, Overbeck N, Cramon PK, Law I, et al. Attenuation correction of long axial field-of-view positron emission tomography using synthetic computed tomography derived from the emission data: application to low-count studies and multiple tracers. Diagnostics. 2023;13:3661. https:\/\/doi.org\/10.3390\/diagnostics13243661.","DOI":"10.3390\/diagnostics13243661"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-026-00879-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00879-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00879-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T08:55:21Z","timestamp":1780390521000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40658-026-00879-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,20]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["879"],"URL":"https:\/\/doi.org\/10.1186\/s40658-026-00879-z","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,20]]},"assertion":[{"value":"15 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of the Hungarian Medical Research Council (ETT-TUKEB); BM\/17504-1\/2024; date of approval: 3rd July 2024.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Due to the retrospective nature of the analysis, the requirement for written informed consent from the patients was waived.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The following co-authors are employees of Mediso Ltd.: B.H., \u00c1.K. and M.S. They participated in the development of the SyCT generator network. The following co-authors are employed by Scanomed Nuclear Medicine Center - a subsidiary of Mediso Ltd. - as nuclear medicine physicians: S.K.B., \u00c1.B. and I.G. This had no influence on the design, interpretation, or decision to publish this study, and Mediso has not supported this work economically. There are no actual or potential conflicts of interest for any of the other authors.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"59"}}