{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T23:44:10Z","timestamp":1785800650747,"version":"3.56.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,24]],"date-time":"2026-05-24T00:00:00Z","timestamp":1779580800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T00:00:00Z","timestamp":1785801600000},"content-version":"vor","delay-in-days":72,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100006775","name":"GE HealthCare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EJNMMI Phys"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Advancements in PET technologies and reconstruction methods have improved spatial resolution and noise in PET\/CT, making respiratory motion artefacts more impactful on image quality. The motion-match CT (MMCT) algorithm estimates the phase of a helical CT and warps it towards the end expiration of a patient\u2019s respiratory cycle. This MMCT-attenuation correction (MMCTAC) can then be used to reconstruct whole body FDG PET\/CT data. The performance of these images were compared to those reconstructed using the uncorrected clinical standard attenuation correction from helical CT (normAC), indicating the proportion of cases where MMCTAC images could reduce motion artefact and improve lesion detectability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A sequential cohort of 145 whole-body FDG PET\/CT scans was previously evaluated for a data-driven gating study, which identified the gated region of interest (ROI) in 98 high-motion patients. 23 of these high-motion patients had small lesions (n=36) identified in the ROI by a clinician to undergo qualitative analysis comparing the two attenuation correction maps used. PET data were reconstructed using BSREM iterative reconstruction with 3 different portions of the collected data: 1. Ungated 6\u00a0min, 2. Ungated 3\u00a0min, 3. Quiescent period gated. These reconstructions were generated using normAC or MMCTAC, totaling six reconstructions for semi-quantitative analysis and clinician evaluation. An experienced radiologist ranked the 6 images and scored them on a 5-point Likert Scale for lesion detectability, diagnostic confidence, and image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In 52% (n=12) of patients with lesions, the clinician ranked all three MMCTAC images higher than the three normAC equivalent reconstructions. Lesion detectability and diagnostic confidence scores retained positive mean differences across the three MMCTAC reconstructions compared to normAC. Similarly, the SUVmax values for 36 lesions demonstrated a significant increase (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05) for MMCTAC versus normAC images across all three reconstructions.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The MMCT algorithm successfully enables the phase-matching of a helical CT to the PET data to reduce the presence of respiratory motion artefact for FDG PET\/CT images. Overall, the motion-matched CTAC image scores demonstrated the algorithm\u2019s efficacy at reducing the motion artefacts present in FDG PET\/CT images, improving diagnostic capability for assessment of lesions in the thorax and upper abdomen.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40658-026-00896-y","type":"journal-article","created":{"date-parts":[[2026,5,24]],"date-time":"2026-05-24T03:06:20Z","timestamp":1779591980000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Improved attenuation correction registration for FDG PET\/CT images using data-driven gating (DDG)-based motion match"],"prefix":"10.1186","volume":"13","author":[{"given":"Zo\u00eb","family":"Wilson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manjeet","family":"Kuhar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuan-Hao","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Johnsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin M.","family":"Bradley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6880-5687","authenticated-orcid":false,"given":"Daniel R.","family":"McGowan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,24]]},"reference":[{"issue":"3","key":"896_CR1","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1148\/radiol.2263011732","volume":"226","author":"GW Goerres","year":"2003","unstructured":"Goerres GW, Burger C, Kamel E, Seifert B, Kaim AH, Buck A, et al. Respiration-induced attenuation artifact at pet\/ct: technical considerations. Radiology. 2003;226(3):906\u201310.","journal-title":"Radiology"},{"key":"896_CR2","first-page":"32","volume":"43","author":"M Osman","year":"2002","unstructured":"Osman M, Cohade C, Nakamoto Y, Wahl R. Clinically significant inaccurate localization of lesions with pet-ct: frequency in 275 patients. J Nucl Med. 2002;43:32\u201332.","journal-title":"J Nucl Med"},{"key":"896_CR3","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1053\/j.semnuclmed.2021.10.005","volume":"52","author":"N Aide","year":"2022","unstructured":"Aide N, Lasnon C, Desmonts C, Armstrong IS, Walker MD, McGowan DR. Advances in pet\/ct technology: an update. Semin Nucl Med. 2022;52:286\u2013301.","journal-title":"Semin Nucl Med"},{"key":"896_CR4","unstructured":"Dai D. Respiratory motion correction in 18F-FDG PET\/CT: A clinical practice approach for enhanced imaging of pulmonary nodules. Soc Nucl Med. 2024;"},{"issue":"11","key":"896_CR5","doi-asserted-by":"publisher","first-page":"1678","DOI":"10.2967\/jnumed.120.242248","volume":"61","author":"MD Walker","year":"2020","unstructured":"Walker MD, Morgan AJ, Bradley KM, McGowan DR. Data-driven respiratory gating outperforms device-based gating for clinical 18f-fdg pet\/ct. J Nucl Med. 2020;61(11):1678\u201383.","journal-title":"J Nucl Med"},{"issue":"7","key":"896_CR6","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.2967\/jnumed.107.039792","volume":"48","author":"KL Gould","year":"2007","unstructured":"Gould KL, Pan T, Loghin C, Johnson NP, Guha A, Sdringola S. Frequent diagnostic errors in cardiac pet\/CT due to misregistration of CT attenuation and emission pet images: a definitive analysis of causes, consequences, and corrections. J Nucl Med. 2007;48(7):1112\u201321.","journal-title":"J Nucl Med"},{"issue":"1","key":"896_CR7","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1148\/radiol.2016152067","volume":"281","author":"F B\u00fcther","year":"2016","unstructured":"B\u00fcther F, Vehren T, Sch\u00e4fers KP, Sch\u00e4fers M. Impact of data-driven respiratory gating in clinical pet. Radiology. 2016;281(1):229\u201338.","journal-title":"Radiology"},{"issue":"2","key":"896_CR8","doi-asserted-by":"publisher","first-page":"279","DOI":"10.2967\/jnumed.118.213884","volume":"60","author":"JG Meier","year":"2019","unstructured":"Meier JG, Wu CC, Cuellar SLB, Truong MT, Erasmus JJ, Einstein SA, et al. Evaluation of a novel elastic respiratory motion correction algorithm on quantification and image quality in abdominothoracic pet\/ct. J Nucl Med. 2019;60(2):279\u201384.","journal-title":"J Nucl Med"},{"issue":"1","key":"896_CR9","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1186\/s40658-024-00644-0","volume":"11","author":"EL Cook","year":"2024","unstructured":"Cook EL, Su K-H, Higgins GS, Johnsen R, Bouhnik J-P, McGowan DR. Data-driven gating (ddg)-based motion match for improved CTAC registration. EJNMMI physics. 2024;11(1):42.","journal-title":"EJNMMI physics"},{"key":"896_CR10","doi-asserted-by":"crossref","unstructured":"Bundschuh R, Andratschke N, Dinges J, Duma M, Astner S, Br\u00fcgel M, et al. Respiratory gated [18F] FDG PET\/CT for target volume delineation in stereotactic radiation treatment of liver metastases. Springer; 2012.","DOI":"10.1007\/s00066-012-0094-3"},{"key":"896_CR11","unstructured":"Khamis H, Wollenweber S. Motionfree: Device-less digital respiratory gating technique, seamlessly integrated in pet imaging routine. GE Healthcare white Paper. 2019;1\u201312."},{"issue":"1126","key":"896_CR12","doi-asserted-by":"publisher","first-page":"20201350","DOI":"10.1259\/bjr.20201350","volume":"94","author":"M Messerli","year":"2021","unstructured":"Messerli M, Liberini V, Gr\u00fcnig H, Maurer A, Skawran S, Lohaus N, et al. Clinical evaluation of data-driven respiratory gating for pet\/CT in an oncological cohort of 149 patients: impact on image quality and patient management. Br J Radiol. 2021;94(1126):20201350.","journal-title":"Br J Radiol"},{"key":"896_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13550-018-0470-9","volume":"9","author":"MD Walker","year":"2019","unstructured":"Walker MD, Morgan AJ, Bradley KM, McGowan DR. Evaluation of data-driven respiratory gating waveforms for clinical pet imaging. EJNMMI Res. 2019;9:1\u201310.","journal-title":"EJNMMI Res"},{"key":"896_CR14","doi-asserted-by":"crossref","unstructured":"Liu C, Pierce L, Alessio A, Wollenweber S, Ganin A, Kinahan P. Impact of respiratory motion on tumor quantification and delineation in wholebody PET\/CT. Society of Nuclear Medicine. 2009.","DOI":"10.1088\/0031-9155\/54\/24\/007"},{"issue":"9","key":"896_CR15","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.2967\/jnumed.115.159301","volume":"56","author":"EJ Teoh","year":"2015","unstructured":"Teoh EJ, McGowan DR, Macpherson RE, Bradley KM, Gleeson FV. Phantom and clinical evaluation of the bayesian penalized likelihood reconstruction algorithm q. clear on an lyso pet\/CT system. J Nucl Med. 2015;56(9):1447\u201352.","journal-title":"J Nucl Med"},{"key":"896_CR16","unstructured":"GE Healthcare: Q.STATIC: Quantitative PET whole-body with automated motion correction. 2013, http:\/\/www.enmodedesign.com\/MotionFree\/QStatic_White%20Paper_DOC1392830_2013_06.pdf."},{"issue":"4","key":"896_CR17","doi-asserted-by":"publisher","first-page":"541","DOI":"10.4300\/JGME-5-4-18","volume":"5","author":"GM Sullivan","year":"2013","unstructured":"Sullivan GM, Artino AR Jr. Analyzing and interpreting data from likert-type scales. J Grad Med Educ. 2013;5(4):541.","journal-title":"J Grad Med Educ"},{"key":"896_CR18","doi-asserted-by":"crossref","unstructured":"Pan T. Comments on the paper \"Data-driven gating (DDG)-based motion match for improved CTAC registration. EJNMMI Phys. 2024; 11(1): 42","DOI":"10.1186\/s40658-024-00644-0"},{"issue":"3","key":"896_CR19","doi-asserted-by":"publisher","first-page":"1626","DOI":"10.1002\/mp.16958","volume":"51","author":"P Sun","year":"2024","unstructured":"Sun P, Thomas MA, Luo D, Pan T. Correcting CT misregistration in data-driven gated (DDG) pet with pet self-gating and deformable image registration. Med Phys. 2024;51(3):1626\u201336.","journal-title":"Med Phys"},{"issue":"1","key":"896_CR20","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s13550-022-00887-x","volume":"12","author":"AH Dias","year":"2022","unstructured":"Dias AH, Schleyer P, Vendelbo MH, Hjorthaug K, Gormsen LC, Munk OL. Clinical feasibility and impact of data-driven respiratory motion compensation studied in 200 whole-body 18f-fdg pet\/ct scans. EJNMMI Res. 2022;12(1):16.","journal-title":"EJNMMI Res"}],"container-title":["EJNMMI Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40658-026-00896-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00896-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40658-026-00896-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T22:50:04Z","timestamp":1785797404000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40658-026-00896-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,24]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["896"],"URL":"https:\/\/doi.org\/10.1186\/s40658-026-00896-y","relation":{},"ISSN":["2197-7364"],"issn-type":[{"value":"2197-7364","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,24]]},"assertion":[{"value":"2 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Patient data were used in this project in the form of anonymised retrospectively reconstructed image datasets. This practice does not require informed consent nor was specific ethical approval required. The study was performed in accordance with the ethical stands as laid down in the 1964 Declaration of Helsinki and its later amendments.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Oxford University Hospitals NHS Foundation Trust has a research contract with GE HealthCare. K-HS and RJ are employees of GE HealthCare.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"79"}}