{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T06:48:50Z","timestamp":1785826130512,"version":"3.56.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100011033","name":"Agencia Estatal de Investigaci\u00f3n","doi-asserted-by":"publisher","award":["PID2020-114582RB-I00\/AEI\/10.13039\/501100011033"],"award-info":[{"award-number":["PID2020-114582RB-I00\/AEI\/10.13039\/501100011033"]}],"id":[{"id":"10.13039\/501100011033","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye and Vis"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>This study aims to detect alterations in the spatio-chromatic pseudophakic vision produced by multifocal diffractive intraocular lenses (IOLs) and provides a physical interpretation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In vitro characterization of the imaging performance of two diffractive IOLs: AT LISA Tri (Zeiss) and FineVision (PhysIOL) in on-bench model eye illuminated with red (R, 625\u00a0nm), green (G, 530\u00a0nm) and blue (B, 455\u00a0nm) lights. We used the metrics: energy efficiency (EE), area under the modulation transfer function, longitudinal chromatic aberration (LCA), and halo intensity. Through-focus (TF) analysis and calculation of the expected defocus curve under white (W) daylight were included. In vivo visual acuity (VA) of 50 pseudophakics (60 eyes) was assessed under W, R, G, B lights at far and near. Two clinical experiments evaluated LCA and R, G, B TF-EE effects on pseudophakic vision and their relative importance.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Clinical mean VA values under W light agreed with the predicted values at far and near for both IOLs. LCA measurements and R, G, B TF-EE curves were consistent with their lens design based on the 0th and 1st diffraction orders operative for far and near vision, respectively. LCA effects were compensated at near but noticed at far (\u2212\u20090.75 D under B light). We detected strong asymmetry in visual resolution depending on the object distance and the illuminating wavelength\u2014red predominance at far, blue predominance at near\u2014in consistency with the TF-EE measurements.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Diffractive multifocal IOL designs produce asymmetries in the spatio-chromatic vision of pseudophakics beyond the alterations strictly due to LCA. VA asymmetry for far\/near object distance under R and B illumination is clinically detectable in subjects implanted with IOLs with 0th and 1st diffraction orders for far and near vision, respectively. Such VA asymmetry cannot be explained solely from the influence of defocus, as would be derived from a chromatic difference of power, but mainly from the wavelength dependence of the EE.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40662-023-00350-5","type":"journal-article","created":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:02:14Z","timestamp":1690848134000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Spatio-chromatic vision with multifocal diffractive intraocular lens"],"prefix":"10.1186","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6950-2373","authenticated-orcid":false,"given":"Maria S.","family":"Millan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Clav\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aurora","family":"Torrents","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jes\u00fas","family":"Armengol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fidel","family":"Vega","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,1]]},"reference":[{"issue":"5","key":"350_CR1","doi-asserted-by":"publisher","first-page":"1877","DOI":"10.1364\/BOE.7.001877","volume":"7","author":"A Alarcon","year":"2016","unstructured":"Alarcon A, Canovas C, Rosen R, Weeber H, Tsai L, Hileman K, et al. Preclinical metrics to predict through-focus visual acuity for pseudophakic patients. Biomed Opt Express. 2016;7(5):1877\u201388.","journal-title":"Biomed Opt Express"},{"issue":"10","key":"350_CR2","doi-asserted-by":"publisher","first-page":"4893","DOI":"10.1364\/BOE.9.004893","volume":"9","author":"F Vega","year":"2018","unstructured":"Vega F, Mill\u00e1n MS, Garz\u00f3n N, Altemir I, Poyales F, Larrosa JM. Visual acuity of pseudophakic patients predicted from in vitro measurements of intraocular lenses with different design. Biomed Opt Express. 2018;9(10):4893\u2013906.","journal-title":"Biomed Opt Express"},{"issue":"5","key":"350_CR3","doi-asserted-by":"publisher","first-page":"2818","DOI":"10.1364\/BOE.388531","volume":"11","author":"J Armengol","year":"2020","unstructured":"Armengol J, Garz\u00f3n N, Vega F, Altemir I, Mill\u00e1n MS. Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients. Biomed Opt Express. 2020;11(5):2818\u201329.","journal-title":"Biomed Opt Express"},{"key":"350_CR4","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1146\/annurev-bioeng-082420-035827","volume":"23","author":"S Marcos","year":"2021","unstructured":"Marcos S, Martinez-Enriquez E, Vinas M, de Castro A, Dorronsoro C, Bang SP, et al. Simulating outcomes of cataract surgery: important advances in ophthalmology. Annu Rev Biomed Eng. 2021;23:277\u2013306.","journal-title":"Annu Rev Biomed Eng"},{"key":"350_CR5","volume-title":"Optics of the human eye","author":"DA Atchison","year":"2000","unstructured":"Atchison DA, Smith G. Optics of the human eye. Oxford: Butterworth-Heinemann; 2000."},{"issue":"3","key":"350_CR6","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0093089","volume":"9","author":"A Radhakrishnan","year":"2014","unstructured":"Radhakrishnan A, Dorronsoro C, Sawides L, Marcos S. Short-term neural adaptation to simultaneous bifocal images. PLoS One. 2014;9(3):e93089.","journal-title":"PLoS One"},{"issue":"4","key":"350_CR7","doi-asserted-by":"publisher","first-page":"2021","DOI":"10.1167\/iovs.15-18861","volume":"57","author":"MS Mill\u00e1n","year":"2016","unstructured":"Mill\u00e1n MS, Vega F, R\u00edos-L\u00f3pez I. Polychromatic image performance of diffractive bifocal intraocular lenses: longitudinal chromatic aberration and energy efficiency. Invest Ophthalmol Vis Sci. 2016;57(4):2021\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"9","key":"350_CR8","doi-asserted-by":"publisher","first-page":"4294","DOI":"10.1364\/BOE.8.004294","volume":"8","author":"MS Mill\u00e1n","year":"2017","unstructured":"Mill\u00e1n MS, Vega F. Extended depth of focus intraocular lens: chromatic performance. Biomed Opt Express. 2017;8(9):4294\u2013309.","journal-title":"Biomed Opt Express"},{"issue":"2","key":"350_CR9","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1364\/OE.18.001637","volume":"18","author":"P Artal","year":"2010","unstructured":"Artal P, Manzanera S, Piers P, Weeber H. Visual effect of the combined correction of spherical and longitudinal chromatic aberrations. Opt Express. 2010;18(2):1637\u201348.","journal-title":"Opt Express"},{"issue":"12","key":"350_CR10","doi-asserted-by":"publisher","first-page":"2746","DOI":"10.1016\/j.jcrs.2015.07.034","volume":"41","author":"HA Weeber","year":"2015","unstructured":"Weeber HA, Meijer ST, Piers PA. Extending the range of vision using diffractive intraocular lens technology. J Cataract Refract Surg. 2015;41(12):2746\u201354.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"350_CR11","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1136\/bjo.2007.118745","volume":"91","author":"H Zhao","year":"2007","unstructured":"Zhao H, Mainster MA. The effect of chromatic dispersion on pseudophakic optical performance. Br J Ophthalmol. 2007;91(9):1225\u20139.","journal-title":"Br J Ophthalmol"},{"issue":"5","key":"350_CR12","doi-asserted-by":"publisher","first-page":"5245","DOI":"10.1364\/OE.18.005245","volume":"18","author":"F Castignoles","year":"2010","unstructured":"Castignoles F, Flury M, Lepine T. Comparison of the efficiency, MTF and chromatic properties of four diffractive bifocal intraocular lens designs. Opt Express. 2010;18(5):5245\u201356.","journal-title":"Opt Express"},{"issue":"7","key":"350_CR13","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1016\/j.jcrs.2013.11.035","volume":"40","author":"S Ravikumar","year":"2014","unstructured":"Ravikumar S, Bradley A, Thibos LN. Chromatic aberration and polychromatic image quality with diffractive multifocal intraocular lenses. J Cataract Refract Surg. 2014;40(7):1192\u2013204.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"350_CR14","doi-asserted-by":"publisher","first-page":"832","DOI":"10.3928\/1081597X-20181108-01","volume":"34","author":"G \u0141abuz","year":"2018","unstructured":"\u0141abuz G, Papadatou E, Khoramnia R, Auffarth GU. Longitudinal chromatic aberration and polychromatic image quality metrics of intraocular lenses. J Refract Surg. 2018;34(12):832\u20138.","journal-title":"J Refract Surg"},{"issue":"4","key":"350_CR15","doi-asserted-by":"publisher","first-page":"2654","DOI":"10.1167\/iovs.13-11912","volume":"54","author":"P P\u00e9rez-Merino","year":"2013","unstructured":"P\u00e9rez-Merino P, Dorronsoro C, Llorente L, Dur\u00e1n S, Jim\u00e9nez-Alfaro I, Marcos S. In vivo chromatic aberration in eyes implanted with intraocular lenses. Invest Ophthalmol Vis Sci. 2013;54(4):2654\u201361.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"350_CR16","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1097\/OPX.0000000000000137","volume":"91","author":"D Siedlecki","year":"2014","unstructured":"Siedlecki D, J\u00f3\u017awik A, Zaj\u0105c M, Hill-Bator A, Turno-Kr\u0119cicka A. In vivo longitudinal chromatic aberration of pseudophakic eyes. Optom Vis Sci. 2014;91(2):240\u20136.","journal-title":"Optom Vis Sci"},{"issue":"8","key":"350_CR17","doi-asserted-by":"publisher","first-page":"4168","DOI":"10.1364\/BOE.10.004168","volume":"10","author":"MS Mill\u00e1n","year":"2019","unstructured":"Mill\u00e1n MS, Vega F, Poyales F, Garz\u00f3n N. Clinical assessment of chromatic aberration in phakic and pseudophakic eyes using a simple autorefractor. Biomed Opt Express. 2019;10(8):4168\u201378.","journal-title":"Biomed Opt Express"},{"issue":"4","key":"350_CR18","doi-asserted-by":"publisher","first-page":"226","DOI":"10.3390\/photonics9040226","volume":"9","author":"M Vinas-Pena","year":"2022","unstructured":"Vinas-Pena M, de Castro A, Dorronsoro C, Gonzalez-Ramos A, Redzovic S, Willet N, et al. Understanding in vivo chromatic aberrations in pseudophakic eyes using on bench and computational approaches. Photonics. 2022;9(4):226.","journal-title":"Photonics"},{"key":"350_CR19","unstructured":"International Organization for Standardization. ISO 11979\u20132:2014. Ophthalmic Implants\u2014Intraocular Lenses\u2014Part 2: Optical Properties and Test Methods. ISO. Geneva, 2014."},{"key":"350_CR20","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.ajo.2019.07.001","volume":"208","author":"G \u0141abuz","year":"2019","unstructured":"\u0141abuz G, Auffarth GU, \u00d6zen A, van den Berg TJTP, Yildirim TM, Son HS, et al. The effect of a spectral filter on visual quality in patients with an extended-depth-of-focus intraocular lens. Am J Ophthalmol. 2019;208:56\u201363.","journal-title":"Am J Ophthalmol"},{"issue":"8","key":"350_CR21","doi-asserted-by":"publisher","first-page":"5695","DOI":"10.1167\/iovs.10-7123","volume":"52","author":"F Vega","year":"2011","unstructured":"Vega F, Alba-Bueno F, Mill\u00e1n MS. Energy distribution between distance and near images in apodized diffractive multifocal intraocular lenses. Invest Ophthalmol Vis Sci. 2011;52(8):5695\u2013701.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"350_CR22","doi-asserted-by":"publisher","first-page":"14002","DOI":"10.2971\/jeos.2014.14002","volume":"9","author":"F Vega","year":"2014","unstructured":"Vega F, Alba-Bueno F, Millan MS. Energy efficiency of a new trifocal intraocular lens. J Eur Opt Soc. 2014;9:14002.","journal-title":"J Eur Opt Soc"},{"issue":"4","key":"350_CR23","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1167\/4.4.9","volume":"4","author":"LN Thibos","year":"2004","unstructured":"Thibos LN, Hong X, Bradley A, Applegate RA. Accuracy and precision of objective refraction from wavefront aberrations. J Vis. 2004;4(4):329\u201351.","journal-title":"J Vis"},{"issue":"11","key":"350_CR24","doi-asserted-by":"publisher","first-page":"688","DOI":"10.3928\/1081597X-20220926-01","volume":"38","author":"JA Azor","year":"2022","unstructured":"Azor JA, Vega F, Armengol J, Millan MS. Optical assessment and expected visual quality of four extended range of vision intraocular lenses. J Refract Surg. 2022;38(11):688\u201397.","journal-title":"J Refract Surg"},{"key":"350_CR25","unstructured":"Hooi LB. Understand RGB LED mixing ratios to realize optimal color in signs and displays. LEDs Magazine. 2013; p. 67\u201372. https:\/\/www.ledsmagazine.com\/smart-lighting-iot\/color-tuning\/article\/16695054\/understand-rgb-led-mixing-ratios-to-realize-optimal-color-in-signs-and-displays-magazine. Accessed 22 May 2023."},{"issue":"18","key":"350_CR26","doi-asserted-by":"publisher","first-page":"23397","DOI":"10.1364\/OE.26.023397","volume":"26","author":"YF Huang","year":"2018","unstructured":"Huang YF, Chi YC, Chen MK, Tsai DP, Huang DW, Lin GR. Red\/green\/blue LD mixed white-light communication at 6500K with divergent diffuser optimization. Opt Express. 2018;26(18):23397\u2013410.","journal-title":"Opt Express"},{"issue":"11","key":"350_CR27","doi-asserted-by":"publisher","first-page":"2060","DOI":"10.1016\/j.jcrs.2011.05.047","volume":"37","author":"D Gatinel","year":"2011","unstructured":"Gatinel D, Pagnoulle C, Houbrechts Y, Gobin L. Design and qualification of a diffractive trifocal optical profile for intraocular lenses. J Cataract Refract Surg. 2011;37(11):2060\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"350_CR28","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1016\/j.jcrs.2019.06.002","volume":"45","author":"J Loicq","year":"2019","unstructured":"Loicq J, Willet N, Gatinel D. Topography and longitudinal chromatic aberration characterizations of refractive-diffractive multifocal intraocular lenses. J Cataract Refract Surg. 2019;45(11):1650\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"350_CR29","doi-asserted-by":"publisher","first-page":"749","DOI":"10.3928\/1081597X-20131021-04","volume":"29","author":"D Madrid-Costa","year":"2013","unstructured":"Madrid-Costa D, Ruiz-Alcocer J, Ferrer-Blasco T, Garc\u00eda-L\u00e1zaro S, Mont\u00e9s-Mic\u00f3 R. Optical quality differences between three multifocal intraocular lenses: bifocal low add, bifocal moderate add, and trifocal. J Refract Surg. 2013;29(11):749\u201354.","journal-title":"J Refract Surg"},{"key":"350_CR30","volume-title":"Visual acuity measurement standard","author":"International Council of Ophthalmology","year":"1984","unstructured":"International Council of Ophthalmology. Visual acuity measurement standard. Brussels: International Council of Ophthalmology; 1984."},{"key":"350_CR31","unstructured":"International Organization for Standardization. ISO 8596:2018. Ophthalmic Optics\u2014Visual Acuity Testing\u2014Standard and Clinical Optotypes and Their Presentation. ISO. Geneva, 2018."},{"issue":"2","key":"350_CR32","doi-asserted-by":"publisher","first-page":"85","DOI":"10.3390\/photonics9020085","volume":"9","author":"L Clav\u00e9","year":"2022","unstructured":"Clav\u00e9 L, Torrents A, Millan MS. Visual acuity at various distances and defocus curve: a good match. Photonics. 2022;9(2):85.","journal-title":"Photonics"},{"issue":"6","key":"350_CR33","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1097\/00006324-199306000-00003","volume":"70","author":"AL Cohen","year":"1993","unstructured":"Cohen AL. Diffractive bifocal lens designs. Optom Vis Sci. 1993;70(6):461\u20138.","journal-title":"Optom Vis Sci"},{"issue":"10","key":"350_CR34","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1016\/j.oftal.2014.01.002","volume":"89","author":"F Alba-Bueno","year":"2014","unstructured":"Alba-Bueno F, Vega F, Mill\u00e1n MS. Halos and multifocal intraocular lenses: origin and interpretation. Arch Soc Esp Oftalmol. 2014;89(10):397\u2013404.","journal-title":"Arch Soc Esp Oftalmol"},{"issue":"1","key":"350_CR35","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jcjo.2016.07.026","volume":"52","author":"Y Eom","year":"2017","unstructured":"Eom Y, Song JS, Kim HM. Spectacle plane add power of multifocal intraocular lenses according to effective lens position. Can J Ophthalmol. 2017;52(1):54\u201360.","journal-title":"Can J Ophthalmol"},{"issue":"3","key":"350_CR36","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1111\/ceo.12181","volume":"42","author":"J Ruiz-Alcocer","year":"2014","unstructured":"Ruiz-Alcocer J, Madrid-Costa D, Garc\u00eda-L\u00e1zaro S, Ferrer-Blasco T, Mont\u00e9s-Mic\u00f3 R. Optical performance of two new trifocal intraocular lenses: through-focus modulation transfer function and influence of pupil size. Clin Exp Ophthalmol. 2014;42(3):271\u20136.","journal-title":"Clin Exp Ophthalmol"},{"issue":"12","key":"350_CR37","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1167\/tvst.9.12.13","volume":"9","author":"MS Mill\u00e1n","year":"2020","unstructured":"Mill\u00e1n MS, Vega F. Through-focus energy efficiency and longitudinal chromatic aberration of three presbyopia-correcting intraocular lenses. Transl Vis Sci Technol. 2020;9(12):13.","journal-title":"Transl Vis Sci Technol"},{"key":"350_CR38","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.2147\/OPTH.S32343","volume":"6","author":"B Cochener","year":"2012","unstructured":"Cochener B, Vryghem J, Rozot P, Lesieur G, Heireman S, Blanckaert JA, et al. Visual and refractive outcomes after implantation of a fully diffractive trifocal lens. Clin Ophthalmol. 2012;6:1421\u20137.","journal-title":"Clin Ophthalmol"},{"key":"350_CR39","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s12886-015-0012-4","volume":"15","author":"J Carballo-Alvarez","year":"2015","unstructured":"Carballo-Alvarez J, Vazquez-Molini JM, Sanz-Fernandez JC, Garc\u00eda-Bella J, Polo V, Garc\u00eda-Feijoo J, et al. Visual outcomes after bilateral trifocal diffractive intraocular lens implantation. BMC Ophthalmol. 2015;15:26.","journal-title":"BMC Ophthalmol"},{"issue":"11","key":"350_CR40","doi-asserted-by":"publisher","first-page":"1625","DOI":"10.1016\/j.jcrs.2019.07.014","volume":"45","author":"M B\u00f6hm","year":"2019","unstructured":"B\u00f6hm M, Petermann K, Hemkeppler E, Kohnen T. Defocus curves of 4 presbyopia-correcting IOL designs: diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus. J Cataract Refract Surg. 2019;45(11):1625\u201336.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"350_CR41","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1097\/00006324-199108000-00005","volume":"68","author":"LN Thibos","year":"1991","unstructured":"Thibos LN, Bradley A, Zhang XX. Effect of ocular chromatic aberration on monocular visual performance. Optom Vis Sci. 1991;68(8):599\u2013607.","journal-title":"Optom Vis Sci"},{"issue":"2","key":"350_CR42","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1364\/JOSAA.19.000266","volume":"19","author":"GY Yoon","year":"2002","unstructured":"Yoon GY, Williams DR. Visual performance after correcting the monochromatic and chromatic aberrations of the eye. J Opt Soc Am A Opt Image Sci Vis. 2002;19(2):266\u201375.","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"issue":"24","key":"350_CR43","doi-asserted-by":"publisher","first-page":"35935","DOI":"10.1364\/OE.27.035935","volume":"27","author":"N Suchkov","year":"2019","unstructured":"Suchkov N, Fern\u00e1ndez EJ, Artal P. Impact of longitudinal chromatic aberration on through-focus visual acuity. Opt Express. 2019;27(24):35935\u201347.","journal-title":"Opt Express"},{"issue":"4","key":"350_CR44","doi-asserted-by":"publisher","first-page":"1","DOI":"10.7149\/OPA.53.4.51047","volume":"53","author":"L Clav\u00e9","year":"2020","unstructured":"Clav\u00e9 L, Torrents A, Rall\u00f3 M, Millan MS. Visual acuity assessment in phakic and pseudophakic eyes under red, green, and blue illumination. Opt Pura Apl. 2020;53(4):1\u201310.","journal-title":"Opt Pura Apl"},{"key":"350_CR45","volume-title":"Foundations of vision","author":"BA Wandell","year":"1995","unstructured":"Wandell BA. Foundations of vision. Sunderland, Massachusetts: Sinauer Associates; 1995."}],"container-title":["Eye and Vision"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-023-00350-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40662-023-00350-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-023-00350-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:03:27Z","timestamp":1690848207000},"score":1,"resource":{"primary":{"URL":"https:\/\/eandv.biomedcentral.com\/articles\/10.1186\/s40662-023-00350-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,1]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["350"],"URL":"https:\/\/doi.org\/10.1186\/s40662-023-00350-5","relation":{},"ISSN":["2326-0254"],"issn-type":[{"value":"2326-0254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,1]]},"assertion":[{"value":"15 March 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research work consists of a laboratory experiment and a cross-sectional study which followed the tenets of the declaration of Helsinki. Subjects were fully informed and provided written consent. The ethics committee of the Hospital de Matar\u00f3 (Consorci Sanitari del Maresme, Barcelona, Spain) and collaborative centers approved the clinical study (CEIm 20\/19 LIO2019).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"32"}}