{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T19:31:52Z","timestamp":1787686312572,"version":"build-2784847793"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:00:00Z","timestamp":1719878400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:00:00Z","timestamp":1719878400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007816","name":"Alcon","doi-asserted-by":"publisher","award":["69799777"],"award-info":[{"award-number":["69799777"]}],"id":[{"id":"10.13039\/100007816","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye and Vis"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To assess rotational stability and refractive outcomes of a new toric hydrophobic acrylic intraocular lens (IOL).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Design<\/jats:title>\n                <jats:p>Single-center, prospective, interventional clinical trial.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A total of 130 eyes of 82 patients with age-related cataract and total corneal astigmatism of greater than 1.0 diopters (D) received a hydrophobic acrylic toric IOL Clareon CNW0T3-9. Baseline measurement for rotational stability evaluation was performed at the end of surgery (EOS), with the patient still supine on the operating table, using non-movable vessels as reference landmarks. Postoperative retroillumination pictures were taken at 1\u00a0h, 1\u00a0week, 1\u00a0month and 4\u20136\u00a0months postoperatively. Subjective manifest refraction was assessed at the 6\u00a0months follow-up visit.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Final results were obtained in 126 eyes of 80 patients. Mean absolute rotation from EOS to 6\u00a0months was 1.33\u2009\u00b1\u20092.00 [0.01, 19.80] degrees. Rotational stability values from EOS to 1\u00a0h, 1\u00a0h to 1\u00a0week, 1\u00a0week to 1\u00a0month and 1\u00a0month to 6\u00a0months were 0.86\u2009\u00b1\u20090.82 [0.00, 3.90], 1.06\u2009\u00b1\u20091.94 [0.00, 19.45], 0.47\u2009\u00b1\u20090.42 [0.00, 2.03] and 0.38\u2009\u00b1\u20090.40 [0.00, 2.56] degrees. Mean preoperative corneal astigmatism was 1.78\u2009\u00b1\u20090.83 [1.00, 4.76] D which changed to a mean postoperative refractive astigmatism of 0.33\u2009\u00b1\u20090.27 [0.00, 1.25] D at 6\u00a0months.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The Clareon toric IOL presented very good rotational stability with a mean absolute rotation below 1.4\u00b0 from EOS to 6\u00a0months. Only two IOLs rotated more than 5\u00b0 with none of them requiring repositioning surgery. Refractive outcomes were satisfying with a mean residual refractive astigmatism below 0.50 D.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Trial registration<\/jats:title>\n                <jats:p>Registered at Clinicaltrials.gov <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.clinicaltrials.gov\/study\/NCT03803852\">NCT03803852<\/jats:ext-link>; on May 17, 2022.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40662-024-00393-2","type":"journal-article","created":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:02:18Z","timestamp":1719878538000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens"],"prefix":"10.1186","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5669-3606","authenticated-orcid":false,"given":"Daniel","family":"Schartm\u00fcller","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Lisy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikolaus","family":"Mahnert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Schranz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Danzinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Schwarzenbacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Pieh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudette","family":"Abela-Formanek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Leydolt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rupert","family":"Menapace","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,2]]},"reference":[{"issue":"5","key":"393_CR1","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/S0886-3350(13)80232-5","volume":"20","author":"K Shimizu","year":"1994","unstructured":"Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling axis shift. J Cataract Refract Surg. 1994;20(5):523\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"393_CR2","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1080\/02713683.2021.1975761","volume":"47","author":"JA Wendelstein","year":"2022","unstructured":"Wendelstein JA, Hoffmann PC, Schwarzenbacher L, Fischinger IR, Hirnschall N, Menapace R, et al. Lasting effects: seven year results of the castrop nomogram for femtosecond laser-assisted paired corneal arcuate incisions. Curr Eye Res. 2022;47(2):225\u201332.","journal-title":"Curr Eye Res"},{"key":"393_CR3","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ajo.2020.11.018","volume":"224","author":"L Schwarzenbacher","year":"2021","unstructured":"Schwarzenbacher L, Schartm\u00fcller D, R\u00f6ggla V, Meyer E, Leydolt C, Menapace R. One-year results of arcuate keratotomy in patients with low to moderate corneal astigmatism using a low-pulse-energy femtosecond laser. Am J Ophthalmol. 2021;224:53\u201365.","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"393_CR4","doi-asserted-by":"publisher","first-page":"165","DOI":"10.3928\/1081597X-20100526-01","volume":"27","author":"JT Poll","year":"2011","unstructured":"Poll JT, Wang L, Koch DD, Weikert MP. Correction of astigmatism during cataract surgery: toric intraocular lens compared to peripheral corneal relaxing incisions. J Refract Surg. 2011;27(3):165\u201371.","journal-title":"J Refract Surg"},{"issue":"3","key":"393_CR5","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1016\/j.jcrs.2013.08.049","volume":"40","author":"N Hirnschall","year":"2014","unstructured":"Hirnschall N, Gangwani V, Crnej A, Koshy J, Maurino V, Findl O. Correction of moderate corneal astigmatism during cataract surgery: toric intraocular lens versus peripheral corneal relaxing incisions. J Cataract Refract Surg. 2014;40(3):354\u201361.","journal-title":"J Cataract Refract Surg"},{"key":"393_CR6","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.ajo.2020.07.019","volume":"220","author":"D Schartm\u00fcller","year":"2020","unstructured":"Schartm\u00fcller D, Schwarzenbacher L, Meyer EL, Schriefl S, Leydolt C, Menapace R. Comparison of long-term rotational stability of three commonly implanted intraocular lenses. Am J Ophthalmol. 2020;220:72\u201381.","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"393_CR7","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1186\/s12886-019-1147-5","volume":"19","author":"U Hahn","year":"2019","unstructured":"Hahn U, Krummenauer F, Schmickler S, Koch J. Rotation of a toric intraocular lens with and without capsular tension ring: data from a multicenter non-inferiority randomized clinical trial (RCT). BMC Ophthalmol. 2019;19(1):143.","journal-title":"BMC Ophthalmol"},{"issue":"4","key":"393_CR8","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.ophtha.2023.10.031","volume":"131","author":"D Schartm\u00fcller","year":"2024","unstructured":"Schartm\u00fcller D, R\u00f6ggla V, Schwarzenbacher L, Meyer EL, Abela-Formanek C, Leydolt C, et al. Influence of a capsular tension ring on capsular bag behavior of a plate haptic intraocular lens: an intraindividual, randomized trial. Ophthalmology. 2024;131(4):445\u201357.","journal-title":"Ophthalmology"},{"issue":"2","key":"393_CR9","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1080\/08820538.2021.1933545","volume":"37","author":"F Ucar","year":"2022","unstructured":"Ucar F, Ozcimen M. Can toric IOL rotation be minimized? Toric IOL-capsular tension ring suturing technique and its clinical outcomes. Semin Ophthalmol. 2022;37(2):158\u201363.","journal-title":"Semin Ophthalmol"},{"issue":"5","key":"393_CR10","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1016\/j.jcrs.2015.04.008","volume":"41","author":"P Arjmand","year":"2015","unstructured":"Arjmand P, Chan TY, Ahmed II. Transscleral suture fixation following recurrent toric intraocular lens rotation. J Cataract Refract Surg. 2015;41(5):912\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"393_CR11","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1016\/j.ophtha.2018.02.012","volume":"125","author":"BS Lee","year":"2018","unstructured":"Lee BS, Chang DF. Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes. Ophthalmology. 2018;125(9):1325\u201331.","journal-title":"Ophthalmology"},{"issue":"3","key":"393_CR12","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/S0886-3350(98)80325-8","volume":"24","author":"T Nagata","year":"1998","unstructured":"Nagata T, Minakata A, Watanabe I. Adhesiveness of AcrySof to a collagen film. J Cataract Refract Surg. 1998;24(3):367\u201370.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"393_CR13","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1097\/j.jcrs.0000000000000746","volume":"48","author":"T Oshika","year":"2022","unstructured":"Oshika T, Sasaki N. One-year multicenter evaluation of a new hydrophobic acrylic intraocular lens with hydroxyethyl methacrylate in an automated preloaded delivery system. J Cataract Refract Surg. 2022;48(3):275\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"393_CR14","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.ajo.2021.06.006","volume":"231","author":"D Schartm\u00fcller","year":"2021","unstructured":"Schartm\u00fcller D, Schwarzenbacher L, Schriefl S, R\u00f6ggla V, Steiner I, Abela-Formanek C, et al. Rotational stability of intraocular lenses: a standardized method for more accurate measurements in future studies. Am J Ophthalmol. 2021;231:200\u20137.","journal-title":"Am J Ophthalmol"},{"key":"393_CR15","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.ajo.2023.11.016","volume":"262","author":"MHM Segers","year":"2024","unstructured":"Segers MHM, Abulafia A, Webers VSC, Verstraaten JW, Vandevenne MMS, Berendschot TTJM, et al. Accuracy of toric intraocular lens calculations using estimated versus measured posterior corneal astigmatism. Am J Ophthalmol. 2024;262:107\u201313.","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"393_CR16","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.jcrs.2017.04.005","volume":"43","author":"DZ Reinstein","year":"2017","unstructured":"Reinstein DZ, Archer TJ, Srinivasan S, Mamalis N, Kohnen T, Dupps WJ Jr, et al. Standard for reporting refractive outcomes of intraocular lens\u2013based refractive surgery. J Cataract Refract Surg. 2017;43(4):435\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"393_CR17","doi-asserted-by":"publisher","first-page":"1886","DOI":"10.1016\/j.jcrs.2013.06.021","volume":"39","author":"C Leydolt","year":"2013","unstructured":"Leydolt C, Kriechbaum K, Schriefl S, Pachala M, Menapace R. Posterior capsule opacification and neodymium:YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses: three-year results. J Cataract Refract Surg. 2013;39(12):1886\u201392.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"393_CR18","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1177\/1120672119834469","volume":"30","author":"T Oshika","year":"2020","unstructured":"Oshika T, Fujita Y, Hirota A, Inamura M, Inoue Y, Miyata K, et al. Comparison of incidence of repositioning surgery to correct misalignment with three toric intraocular lenses. Eur J Ophthalmol. 2020;30(4):680\u20134.","journal-title":"Eur J Ophthalmol"},{"issue":"3","key":"393_CR19","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/j.jcrs.2004.07.019","volume":"31","author":"A Viestenz","year":"2005","unstructured":"Viestenz A, Seitz B, Langenbucher A. Evaluating the eye\u2019s rotational stability during standard photography: effect on determining the axial orientation of toric intraocular lenses. J Cataract Refract Surg. 2005;31(3):557\u201361.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"393_CR20","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1136\/bjophthalmol-2017-311797","volume":"103","author":"D Schartm\u00fcller","year":"2019","unstructured":"Schartm\u00fcller D, Schriefl S, Schwarzenbacher L, Leydolt C, Menapace R. True rotational stability of a single-piece hydrophobic intraocular lens. Br J Ophthalmol. 2019;103(2):186\u201390.","journal-title":"Br J Ophthalmol"},{"issue":"9","key":"393_CR21","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1016\/j.ophtha.2017.05.025","volume":"124","author":"Y Inoue","year":"2017","unstructured":"Inoue Y, Takehara H, Oshika T. Axis misalignment of toric intraocular lens: placement error and postoperative rotation. Ophthalmology. 2017;124(9):1424\u20135.","journal-title":"Ophthalmology"},{"issue":"3","key":"393_CR22","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.jcrs.2017.10.053","volume":"44","author":"D Tognetto","year":"2018","unstructured":"Tognetto D, Perrotta AA, Bauci F, Rinaldi S, Antonuccio M, Pellegrino FA, et al. Quality of images with toric intraocular lenses. J Cataract Refract Surg. 2018;44(3):376\u201381.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"393_CR23","doi-asserted-by":"publisher","first-page":"112","DOI":"10.3928\/1081597X-20201216-01","volume":"37","author":"D Schartm\u00fcller","year":"2021","unstructured":"Schartm\u00fcller D, R\u00f6ggla V, Schwarzenbacher L, Leydolt C, Menapace R. Rotational stability of a new hydrophobic acrylic IOL with modified C-loop haptics. J Refract Surg. 2021;37(2):112\u20138.","journal-title":"J Refract Surg"},{"issue":"11","key":"393_CR24","doi-asserted-by":"publisher","first-page":"6847","DOI":"10.1167\/iovs.15-17228","volume":"56","author":"K Erb-Eigner","year":"2015","unstructured":"Erb-Eigner K, Hirnschall N, Hackl C, Schmidt C, Asbach P, Findl O. Predicting lens diameter: ocular biometry with high-resolution MRI. Invest Ophthalmol Vis Sci. 2015;56(11):6847\u201354.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"6","key":"393_CR25","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1097\/j.jcrs.0000000000001158","volume":"49","author":"J Zeilinger","year":"2023","unstructured":"Zeilinger J, Hienert J, Ruiss M, Pilwachs C, Findl O. Rotational stability of a new toric intraocular lens with an advanced optical profile. J Cataract Refract Surg. 2023;49(6):584\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"393_CR26","unstructured":"American National Standard for Ophthalmics - Toric Intraocular Lenses ANSI Z80.30\u20132018."},{"key":"393_CR27","unstructured":"Ophthalmic Implants - Intraocular Lenses - Part 7: Clinical Investigations of Intraocular Lenses for the Correction of Aphakia (ISO 11979\u20137:2018)."},{"issue":"6","key":"393_CR28","doi-asserted-by":"publisher","first-page":"402","DOI":"10.3928\/1081597X-20130515-04","volume":"29","author":"PC Hoffmann","year":"2013","unstructured":"Hoffmann PC, Wahl J, H\u00fctz WW, Preu\u00dfner PR. A ray tracing approach to calculate toric intraocular lenses. J Refract Surg. 2013;29(6):402\u20138.","journal-title":"J Refract Surg"},{"issue":"1","key":"393_CR29","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.jcrs.2014.04.033","volume":"41","author":"L Zhang","year":"2015","unstructured":"Zhang L, Sy ME, Mai H, Yu F, Hamilton RD. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation. J Cataract Refract Surg. 2015;41(1):84\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"393_CR30","doi-asserted-by":"publisher","first-page":"171","DOI":"10.3928\/1081597X-20230103-04","volume":"39","author":"CH R\u00e9mignon","year":"2023","unstructured":"R\u00e9mignon CH, Levron A, Agard E, Douma I, El-Chehab H, Brunet O, et al. Impact of total corneal astigmatism estimated with the abulafia-koch formula versus measured with a SS-OCT biometer on the refractive outcomes of a toric intraocular lens in cataract surgery. J Refract Surg. 2023;39(3):171\u20139.","journal-title":"J Refract Surg"},{"issue":"2","key":"393_CR31","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.jcrs.2015.11.036","volume":"42","author":"O Reitblat","year":"2016","unstructured":"Reitblat O, Levy A, Kleinmann G, Abulafia A, Assia EI. Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: comparison of methodologies. J Cataract Refract Surg. 2016;42(2):217\u201325.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"393_CR32","doi-asserted-by":"publisher","first-page":"e0288316","DOI":"10.1371\/journal.pone.0288316","volume":"18","author":"A Langenbucher","year":"2023","unstructured":"Langenbucher A, Szentm\u00e1ry N, Cayless A, Wendelstein J, Hoffmann P. Prediction of corneal power vectors after cataract surgery with toric lens implantation\u2013a vector analysis. PLoS One. 2023;18(9):e0288316.","journal-title":"PLoS One"},{"issue":"10","key":"393_CR33","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1097\/j.jcrs.0000000000001271","volume":"49","author":"J Wendelstein","year":"2023","unstructured":"Wendelstein J, Casazza M, Riaz KM, Fischinger I, Fuchs B, Bolz M, et al. Characteristics of surgically induced astigmatism after standardized microincisional cataract surgery with a superior limbal incision. J Cataract Refract Surg. 2023;49(10):1025\u201335.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"393_CR34","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.jcrs.2016.02.038","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Koch DD, Wang L, Hill WE, Assia EI, Franchina M, et al. New regression formula for toric intraocular lens calculations. J Cataract Refract Surg. 2016;42(5):663\u201371.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"393_CR35","doi-asserted-by":"publisher","first-page":"642","DOI":"10.3928\/1081597X-20210712-07","volume":"37","author":"V R\u00f6ggla","year":"2021","unstructured":"R\u00f6ggla V, Schartm\u00fcller D, Schwarzenbacher L, Chbib RAL, Leydolt C, Menapace R. Comparison of axis determination with different toric intraocular lens power calculation methods. J Refract Surg. 2021;37(9):642\u20137.","journal-title":"J Refract Surg"}],"container-title":["Eye and Vision"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-024-00393-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40662-024-00393-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-024-00393-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:04:06Z","timestamp":1719878646000},"score":1,"resource":{"primary":{"URL":"https:\/\/eandv.biomedcentral.com\/articles\/10.1186\/s40662-024-00393-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,2]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["393"],"URL":"https:\/\/doi.org\/10.1186\/s40662-024-00393-2","relation":{},"ISSN":["2326-0254"],"issn-type":[{"value":"2326-0254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,2]]},"assertion":[{"value":"5 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the ethics committee of the Medical University of Vienna (EK 1978\/2018) and registered at a public clinical trial registry (NCT03803852) prior to the start of the study. All patients provided written informed consent prior to study inclusion.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"25"}}