{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T19:47:00Z","timestamp":1791229620164,"version":"4.1.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,2]],"date-time":"2024-12-02T00:00:00Z","timestamp":1733097600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,2]],"date-time":"2024-12-02T00:00:00Z","timestamp":1733097600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100010399","name":"European Society of Cataract and Refractive Surgeons","doi-asserted-by":"publisher","award":["IOLExcg."],"award-info":[{"award-number":["IOLExcg."]}],"id":[{"id":"10.13039\/100010399","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100010441","name":"Medizinischen Fakult\u00e4t Heidelberg, Universit\u00e4t Heidelberg","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100010441","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100007316","name":"Klaus Tschira Stiftung","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007316","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Medizinische Fakult\u00e4t Heidelberg der Universit\u00e4t Heidelberg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye and Vis"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Homogeneous intraocular lens (IOL) calcification deteriorates patient\u2019s visual quality. There is a lack of functional and patient-reported data on patients with this material change undergoing IOL exchange surgery. The aim of this study was to evaluate subjective and objective outcomes following IOL exchange due to homogeneous IOL calcification to improve evidence-based patient counseling.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this prospective, non-interventional, clinical study, 53 eyes of 42 patients with homogeneous IOL calcification were included. IOL exchange was performed in 30 out of 53 eyes. Subjective symptoms using a quality-of-life questionnaire (Catquest-9SF), photic phenomena, corrected distance visual acuity (CDVA), straylight (C-Quant, Oculus, Wezlar, Germany) and contrast sensitivity with and without glare (CSV-1000, VectorVision, Houston, USA) were assessed before (T0) and at 3 to 12 months after IOL exchange (T1).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Preoperative CDVA and straylight did not correlate. Average halo and glare size and intensity decreased and Catquest-9SF items improved. The CDVA rose significantly from 0.16\u2009\u00b1\u20090.13 to 0.05\u2009\u00b1\u20090.10 logMAR, and contrast sensitivity increased with and without glare. The straylight value decreased statistically and clinically significant from 2.32\u2009\u00b1\u20090.34 to 1.23\u2009\u00b1\u20090.33 log(s).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Homogeneous IOL calcification is not always associated with a pronounced reduction in visual acuity. In most cases, IOL exchange still reduces subjective complaints and improves quality of vision of affected patients. Visual acuity should not be the sole functional parameter in assessing patients with homogeneous IOL calcification as intraocular straylight and contrast sensitivity can better objectify patients\u2019 visual impairment. We recommend a straylight value above 1.56 log(s) as a cut-off when deciding on an IOL exchange surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40662-024-00415-z","type":"journal-article","created":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T19:02:24Z","timestamp":1733079744000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Establishing an objective decision criterion for intraocular lens exchange due to homogeneous calcification: a prospective clinical analysis"],"prefix":"10.1186","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3687-5082","authenticated-orcid":false,"given":"Timur M.","family":"Yildirim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grzegorz","family":"\u0141abuz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikola","family":"Henningsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyeck-Soo","family":"Son","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor A.","family":"Augustin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leoni","family":"Britz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lizaveta","family":"Chychko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd U.","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,2]]},"reference":[{"issue":"12","key":"415_CR1","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1097\/j.jcrs.0000000000000349","volume":"46","author":"J Goemaere","year":"2020","unstructured":"Goemaere J, Trigaux C, Denissen L, Dragnea D, Hua MT, Tassignon MJ, et al. Fifteen years of IOL exchange: indications, outcomes, and complications. J Cataract Refract Surg. 2020;46(12):1596\u2013603.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"415_CR2","first-page":"20","volume":"46","author":"T Neuhann","year":"2020","unstructured":"Neuhann T, Yildirim TM, Son HS, Merz PR, Khoramnia R, Auffarth GU. Reasons for explantation, demographics, and material analysis of 200 intraocular lens explants. J Cataract Refract Surg. 2020;46(1):20\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"415_CR3","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/S0146-2776(84)80052-X","volume":"10","author":"N Ballin","year":"1984","unstructured":"Ballin N. Glistenings in injection-molded lens. J Am Intraocul Implant Soc. 1984;10(4):473.","journal-title":"J Am Intraocul Implant Soc"},{"key":"415_CR4","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.ajo.2018.08.032","volume":"196","author":"G \u0141abuz","year":"2018","unstructured":"\u0141abuz G, Knebel D, Auffarth GU, Fang H, van den Berg TJ, et al. Glistening formation and light scattering in six hydrophobic-acrylic intraocular lenses. Am J Ophthalmol. 2018;196:112\u201320.","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"415_CR5","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.ajo.2005.08.045","volume":"141","author":"L Werner","year":"2006","unstructured":"Werner L, Hunter B, Stevens S, Chew JJ, Mamalis N. Role of silicon contamination on calcification of hydrophilic acrylic intraocular lenses. Am J Ophthalmol. 2006;141(1):35\u201343.","journal-title":"Am J Ophthalmol"},{"key":"415_CR6","unstructured":"Nataloni R, Donald T. Foldable lens trends: seeking the greatest biocompatibility. Cataract Refract Surg Today Eur. 2018. pp. 16\u201320."},{"issue":"9","key":"415_CR7","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1016\/j.jcrs.2016.06.032","volume":"42","author":"P Bompastor-Ramos","year":"2016","unstructured":"Bompastor-Ramos P, P\u00f3voa J, Lobo C, Rodriguez AE, Ali\u00f3 JL, Werner L, et al. Late postoperative opacification of a hydrophilic-hydrophobic acrylic intraocular lens. J Cataract Refract Surg. 2016;42(9):1324\u201331.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"415_CR8","doi-asserted-by":"publisher","first-page":"1624","DOI":"10.1097\/j.jcrs.0000000000000342","volume":"46","author":"NCD Scherer","year":"2020","unstructured":"Scherer NCD, M\u00fcller K, Prahs PM, Radeck V, Helbig H, M\u00e4rker DA. Serial opacification of a hydrophilic-hydrophobic acrylic intraocular lens: analysis of potential risk factors. J Cataract Refract Surg. 2020;46(12):1624\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"415_CR9","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1177\/1120672119830581","volume":"30","author":"JF Costa","year":"2020","unstructured":"Costa JF, Bompastor-Ramos P, Marques M, Henriques J, P\u00f3voa J, Lobo C, et al. Large-scale opacification of a hydrophilic\/hydrophobic intraocular lens. Eur J Ophthalmol. 2020;30(2):307\u201314.","journal-title":"Eur J Ophthalmol"},{"issue":"34","key":"415_CR10","first-page":"17","volume":"13","author":"A Foster","year":"2000","unstructured":"Foster A. Vision 2020: the cataract challenge. Community Eye Health. 2000;13(34):17\u20139.","journal-title":"Community Eye Health"},{"issue":"12","key":"415_CR11","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1016\/S0161-6420(00)00416-4","volume":"107","author":"L Werner","year":"2000","unstructured":"Werner L, Apple DJ, Escobar-Gomez M, Ohrstr\u00f6m A, Crayford BB, Bianchi R, et al. Postoperative deposition of calcium on the surfaces of a hydrogel intraocular lens. Ophthalmology. 2000;107(12):2179\u201385.","journal-title":"Ophthalmology"},{"issue":"1","key":"415_CR12","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.ophtha.2007.02.016","volume":"115","author":"IM Neuhann","year":"2008","unstructured":"Neuhann IM, Kleinmann G, Apple DJ. A new classification of calcification of intraocular lenses. Ophthalmology. 2008;115(1):73\u20139.","journal-title":"Ophthalmology"},{"issue":"1","key":"415_CR13","doi-asserted-by":"publisher","first-page":"20","DOI":"10.3928\/1081597X-20191119-01","volume":"36","author":"TM Yildirim","year":"2020","unstructured":"Yildirim TM, Labuz G, Khoramnia R, Son HS, Schickhardt SK, Lieberwirth I, et al. Impact of primary calcification in segmented refractive bifocal intraocular lenses on optical performance including straylight. J Refract Surg. 2020;36(1):20\u20137.","journal-title":"J Refract Surg"},{"issue":"6","key":"415_CR14","doi-asserted-by":"publisher","first-page":"759","DOI":"10.5858\/arpa.2019-0626-RA","volume":"145","author":"P Kanclerz","year":"2021","unstructured":"Kanclerz P, Yildirim TM, Khoramnia R. Microscopic characteristics of late intraocular lens opacifications. Arch Pathol Lab Med. 2021;145(6):759\u201367.","journal-title":"Arch Pathol Lab Med"},{"issue":"1","key":"415_CR15","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/ICU.0000000000000719","volume":"32","author":"P Kanclerz","year":"2021","unstructured":"Kanclerz P, Yildirim TM, Khoramnia R. A review of late intraocular lens opacifications. Curr Opin Ophthalmol. 2021;32(1):31\u201344.","journal-title":"Curr Opin Ophthalmol"},{"key":"415_CR16","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1186\/s12886-015-0149-1","volume":"15","author":"T Tandogan","year":"2015","unstructured":"Tandogan T, Khoramnia R, Choi CY, Scheuerle A, Wenzel M, Hugger P, et al. Optical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study. BMC Ophthalmol. 2015;15:170.","journal-title":"BMC Ophthalmol"},{"key":"415_CR17","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.ajo.2023.06.025","volume":"257","author":"F Ucar","year":"2024","unstructured":"Ucar F, Cetinkaya S, Kahraman H, Yener HI. Changes in intraocular lens explantation indications and comparison of various explantation techniques. Am J Ophthalmol. 2024;257:84\u201390.","journal-title":"Am J Ophthalmol"},{"key":"415_CR18","doi-asserted-by":"publisher","first-page":"6653621","DOI":"10.1155\/2024\/6653621","volume":"2024","author":"M Magyar","year":"2024","unstructured":"Magyar M, Szentm\u00e1ry N, Ujv\u00e1ry L, S\u00e1ndor GL, Schirra F, Nagy ZZ, et al. Indications and outcomes of intraocular lens explantation in a tertiary eyecare center in Hungary between 2006 and 2020. J Ophthalmol. 2024;2024:6653621.","journal-title":"J Ophthalmol"},{"issue":"9","key":"415_CR19","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1097\/j.jcrs.0000000000000553","volume":"47","author":"G \u0141abuz","year":"2021","unstructured":"\u0141abuz G, Yildirim TM, Khoramnia R, Son HS, Auffarth GU. Optical function of intraocular lenses in different opacification patterns: metrology analysis of 67 explants. J Cataract Refract Surg. 2021;47(9):1210\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"415_CR20","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1016\/j.jcrs.2014.10.035","volume":"41","author":"G \u0141abuz","year":"2015","unstructured":"\u0141abuz G, Reus NJ, van den Berg TJ. Ocular straylight in the normal pseudophakic eye. J Cataract Refract Surg. 2015;41(7):1406\u201315.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"415_CR21","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.zemedi.2012.10.009","volume":"23","author":"TJ van den Berg","year":"2013","unstructured":"van den Berg TJ, Franssen L, Kruijt B, Coppens JE. History of ocular straylight measurement: a review. Z Med Phys. 2013;23(1):6\u201320.","journal-title":"Z Med Phys"},{"issue":"8","key":"415_CR22","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1055\/a-2130-6944","volume":"240","author":"TM Yildirim","year":"2023","unstructured":"Yildirim TM, Auffarth GU, Henningsen N, \u0141abuz G, Augustin VA, Son HS, et al. Differential diagnosis of changes in intraocular lenses. Klin Monbl Augenheilkd. 2023;240(8):952\u20139.","journal-title":"Klin Monbl Augenheilkd"},{"issue":"1","key":"415_CR23","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.jcrs.2014.10.025","volume":"41","author":"L Werner","year":"2015","unstructured":"Werner L, Wilbanks G, Nieuwendaal CP, Dhital A, Waite A, Schmidinger G, et al. Localized opacification of hydrophilic acrylic intraocular lenses after procedures using intracameral injection of air or gas. J Cataract Refract Surg. 2015;41(1):199\u2013207.","journal-title":"J Cataract Refract Surg"},{"key":"415_CR24","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ajo.2018.06.002","volume":"193","author":"TM Yildirim","year":"2018","unstructured":"Yildirim TM, Auffarth GU, \u0141abuz G, Bopp S, Son HS, Khoramnia R. Material analysis and optical quality assessment of opacified hydrophilic acrylic intraocular lenses after pars plana vitrectomy. Am J Ophthalmol. 2018;193:10\u20139.","journal-title":"Am J Ophthalmol"},{"key":"415_CR25","doi-asserted-by":"publisher","first-page":"100857","DOI":"10.1016\/j.ajoc.2020.100857","volume":"19","author":"JM Vlasman","year":"2020","unstructured":"Vlasman JM, van den Berg TJTP, Reus NJ. Straylight due to intraocular lens opacification in a patient with asteroid hyalosis. Am J Ophthalmol Case Rep. 2020;19:100857.","journal-title":"Am J Ophthalmol Case Rep"},{"issue":"6","key":"415_CR26","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1111\/j.1755-3768.2008.01326.x","volume":"87","author":"R Michael","year":"2009","unstructured":"Michael R, van Rijn LJ, van den Berg TJ, Barraquer RI, Grabner G, Wilhelm H, et al. Association of lens opacities, intraocular straylight, contrast sensitivity and visual acuity in European drivers. Acta Ophthalmol. 2009;87(6):666\u201371.","journal-title":"Acta Ophthalmol"},{"issue":"5","key":"415_CR27","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/j.jcrs.2011.11.048","volume":"38","author":"IJ van der Meulen","year":"2012","unstructured":"van der Meulen IJ, Gjertsen J, Kruijt B, Witmer JP, Rulo A, Schlingemann RO, et al. Straylight measurements as an indication for cataract surgery. J Cataract Refract Surg. 2012;38(5):840\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"415_CR28","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1016\/j.jcrs.2013.10.030","volume":"40","author":"R Lapid-Gortzak","year":"2014","unstructured":"Lapid-Gortzak R, van der Meulen IJ, van der Linden JW, Mourits MP, van den Berg TJ. Straylight before and after phacoemulsification in eyes with preoperative corrected distance visual acuity better than 0.1 logMAR. J Cataract Refract Surg. 2014;40(5):748\u201355.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"415_CR29","doi-asserted-by":"publisher","first-page":"1430","DOI":"10.3760\/cma.j.issn.0366-6999.20123274","volume":"126","author":"Y Cheng","year":"2013","unstructured":"Cheng Y, Shi X, Cao XG, Li XX, Bao YZ. Correlation between contrast sensitivity and the lens opacities classification system III in age-related nuclear and cortical cataracts. Chin Med J (Engl). 2013;126(8):1430\u20135.","journal-title":"Chin Med J"},{"key":"415_CR30","doi-asserted-by":"publisher","first-page":"3109","DOI":"10.2147\/OPTH.S367490","volume":"16","author":"F Vingopoulos","year":"2022","unstructured":"Vingopoulos F, Kasetty M, Garg I, Silverman RF, Katz R, Vasan RA, et al. Active learning to characterize the full contrast sensitivity function in cataracts. Clin Ophthalmol. 2022;16:3109\u201318.","journal-title":"Clin Ophthalmol"},{"issue":"5","key":"415_CR31","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1016\/j.jcrs.2018.01.033","volume":"44","author":"G \u0141abuz","year":"2018","unstructured":"\u0141abuz G, Yildirim TM, van den Berg T, Khoramnia R, Auffarth GU. Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas. J Cataract Refract Surg. 2018;44(5):615\u201322.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"415_CR32","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1097\/OPX.0000000000000001","volume":"90","author":"J Khadka","year":"2013","unstructured":"Khadka J, McAlinden C, Pesudovs K. Quality assessment of ophthalmic questionnaires: review and recommendations. Optom Vis Sci. 2013;90(8):720\u201344.","journal-title":"Optom Vis Sci"},{"issue":"8","key":"415_CR33","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1016\/S0886-3350(97)80321-5","volume":"23","author":"M Lundstr\u00f6m","year":"1997","unstructured":"Lundstr\u00f6m M, Roos P, Jensen S, Fregell G. Catquest questionnaire for use in cataract surgery care: description, validity, and reliability. J Cataract Refract Surg. 1997;23(8):1226\u201336.","journal-title":"J Cataract Refract Surg"}],"container-title":["Eye and Vision"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-024-00415-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40662-024-00415-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-024-00415-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T20:03:30Z","timestamp":1733083410000},"score":1,"resource":{"primary":{"URL":"https:\/\/eandv.biomedcentral.com\/articles\/10.1186\/s40662-024-00415-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,2]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["415"],"URL":"https:\/\/doi.org\/10.1186\/s40662-024-00415-z","relation":{},"ISSN":["2326-0254"],"issn-type":[{"value":"2326-0254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,2]]},"assertion":[{"value":"12 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was performed in accordance with the principles of the Declaration of Helsinki. Before commencing the study, approval was obtained from the local Ethics Committee (S-193\/2022) and the collection of this patient data was registered in the Clinical Trials Register (DRKS00007837). All patients provided written informed consent to participate in this study prior to any study-related examinations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Timur M. Yildirim receives personal fees from Alcon and Hoya, and non-financial support from Johnson & Johnson, outside the submitted work. Victor A. Augustin reports grants from Kowa and Eyeyon. Ramin Khoramnia reports grants, personal fees, and non-financial support from Alcon, Johnson & Johnson, Hoya, Physiol, Rayner, personal fees, and non-financial support from Kowa, Ophtec, Oculentis\/Teleon, Santen, and Acufocus, outside the submitted work. Gerd U. Auffarth reports grants, personal fees, non-financial support and consulting fees from Johnson & Johnson and Alcon, grants, personal fees, and non-financial support from Carl Zeiss Meditec, Hoya, Kowa, Oculentis\/Teleon, Rayner, Santen, Sifi, Ursapharm, grants, and personal fees from Biotech, Oculus, EyeYon grants from Acufocus, Anew, Contamac, Glaukos, Physiol, Rheacell, outside the submitted work. Grzegorz \u0141abuz, Hyeck-Soo Son, Nikola Henningsen, Leoni Britz and Lizaveta Chychko have nothing to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"46"}}