{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T15:47:46Z","timestamp":1794498466484,"version":"4.9.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T00:00:00Z","timestamp":1759017600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T00:00:00Z","timestamp":1759017600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the open project of Institute of Optometry and Vision Science in Nankai University","award":["NKSGY202304"],"award-info":[{"award-number":["NKSGY202304"]}]},{"name":"the open project of Institute of Optometry and Vision Science in Nankai University","award":["NKSGP202307"],"award-info":[{"award-number":["NKSGP202307"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye and Vis"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>This study investigated how aspheric lens design changes the corneal power distribution and how such changes are associated with the axial elongation in myopic children who underwent orthokeratology.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This retrospective study of 116 eyes from children aged 8\u201313\u00a0years were enrolled and fitted with three types of lenses: fully spherical lenses (Alpha, n\u2009=\u200945), those with an aspheric alignment curve (AC) and a\u00a0spherical base curve (BC) (Dreamlite, n\u2009=\u200937), and lenses with a\u00a0partly aspheric BC and an aspheric AC (Myok, n\u2009=\u200934). Axial lengths were measured at baseline, 6 and 12\u00a0months. Corneal topography maps obtained at baseline and after 1\u00a0month of lens wear were analyzed with Fourier decomposition: the F0 (spherical), F1 (asymmetry), F2 (regular astigmatism), and F3 (higher-order irregularity) components were extracted and quantified across ten concentric rings with 0.5\u00a0mm width.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The 1-year axial elongation was 0.26\u2009\u00b1\u20090.21\u00a0mm, 0.16\u2009\u00b1\u20090.19\u00a0mm, and 0.10\u2009\u00b1\u20090.19\u00a0mm for the Alpha, Dreamlite, and Myok groups, respectively (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). In the 1-month maps, F0 and F1 peaked at the mid-periphery, and declined peripherally. Dreamlite exhibited F0 values greater than those of Alpha (mean difference: 0.02\u20130.46 D) within the central 2\u00a0mm (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01) and lower than Myok\u2019s values (mean difference: 0.66\u20131.05 D) in the peripheral 3 to 4.5\u00a0mm (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01). Dreamlite also displayed greater F1 compared to Alpha (mean difference: 0.68\u20130.78 D) within the 1 to 2\u00a0mm rings (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01) but showed no significant difference from Myok. F2 and F3 remained flat and small. Three components, F0, F1, and F3, were negatively associated with axial elongation in these children (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Lenses featuring an aspheric AC resulted in reduced axial elongation and increased spherical power and asymmetry in the central cornea, while lenses with a partly aspherical BC improved spherical power in the mid-periphery. A smaller axial elongation was associated with greater post treatment central cornea asymmetry.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40662-025-00453-1","type":"journal-article","created":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T02:10:14Z","timestamp":1759025414000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Association between axial elongation and corneal power distribution changes induced by aspheric orthokeratology lenses"],"prefix":"10.1186","volume":"12","author":[{"given":"Mengdi","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kailang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua","family":"Bi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingyi","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lihua","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,28]]},"reference":[{"key":"453_CR1","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.preteyeres.2017.09.004","volume":"62","author":"IG Morgan","year":"2018","unstructured":"Morgan IG, French AN, Ashby RS, Guo X, Ding X, He M, et al. The epidemics of myopia: aetiology and prevention. Prog Retin Eye Res. 2018;62:134\u201349.","journal-title":"Prog Retin Eye Res"},{"issue":"3","key":"453_CR2","doi-asserted-by":"publisher","first-page":"M132","DOI":"10.1167\/iovs.18-25955","volume":"60","author":"JS Wolffsohn","year":"2019","unstructured":"Wolffsohn JS, Kollbaum PS, Berntsen DA, Atchison DA, Benavente A, Bradley A, et al. IMI - Clinical Myopia Control Trials and Instrumentation Report. Invest Ophthalmol Vis Sci. 2019;60(3):M132\u201360.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"5","key":"453_CR3","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","volume":"123","author":"BA Holden","year":"2016","unstructured":"Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS, Sankaridurg P, et al. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology. 2016;123(5):1036\u201342.","journal-title":"Ophthalmology"},{"issue":"3","key":"453_CR4","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1111\/j.1444-0938.2006.00044.x","volume":"89","author":"HA Swarbrick","year":"2006","unstructured":"Swarbrick HA. Orthokeratology review and update. Clin Exp Optom. 2006;89(3):124\u201343.","journal-title":"Clin Exp Optom"},{"issue":"2","key":"453_CR5","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/j.clae.2021.02.003","volume":"44","author":"SJ Vincent","year":"2021","unstructured":"Vincent SJ, Cho P, Chan KY, Fadel D, Ghorbani-Mojarrad N, Gonz\u00e1lez-M\u00e9ijome JM, et al. CLEAR - Orthokeratology. Cont Lens Anterior Eye. 2021;44(2):240\u201369.","journal-title":"Cont Lens Anterior Eye"},{"issue":"5","key":"453_CR6","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/00006324-200005000-00012","volume":"77","author":"JJ Nichols","year":"2000","unstructured":"Nichols JJ, Marsich MM, Nguyen M, Barr JT, Bullimore MA. Overnight orthokeratology. Optom Vis Sci. 2000;77(5):252\u20139.","journal-title":"Optom Vis Sci"},{"issue":"10","key":"453_CR7","doi-asserted-by":"publisher","first-page":"1843","DOI":"10.18240\/ijo.2024.10.10","volume":"17","author":"HL Ni","year":"2024","unstructured":"Ni HL, Chen X, Chen DY, Hu PK, Wu ZY. Effects of different orthokeratology lens designs on slowing axial length elongation in children with myopia. Int J Ophthalmol. 2024;17(10):1843\u20139.","journal-title":"Int J Ophthalmol"},{"issue":"1","key":"453_CR8","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.clae.2019.11.012","volume":"43","author":"R Chen","year":"2020","unstructured":"Chen R, Yu J, Lipson M, Cheema AA, Chen Y, Lian H, et al. Comparison of four different orthokeratology lenses in controlling myopia progression. Cont Lens Anterior Eye. 2020;43(1):78\u201383.","journal-title":"Cont Lens Anterior Eye"},{"issue":"3","key":"453_CR9","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1097\/ICL.0000000000000867","volume":"48","author":"T Hiraoka","year":"2022","unstructured":"Hiraoka T. Myopia control with orthokeratology: a review. Eye Contact Lens. 2022;48(3):100\u20134.","journal-title":"Eye Contact Lens"},{"issue":"5","key":"453_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2024.102251","volume":"47","author":"J Santodomingo-Rubido","year":"2024","unstructured":"Santodomingo-Rubido J, Cheung SW, Villa-Collar C. A new look at the myopia control efficacy of orthokeratology. Contact Lens Anterior Eye. 2024;47(5):102251.","journal-title":"Contact Lens Anterior Eye"},{"issue":"11","key":"453_CR11","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1097\/OPX.0000000000000064","volume":"90","author":"P Kang","year":"2013","unstructured":"Kang P, Gifford P, Swarbrick H. Can manipulation of orthokeratology lens parameters modify peripheral refraction? Optom Vis Sci. 2013;90(11):1237\u201348.","journal-title":"Optom Vis Sci"},{"issue":"9","key":"453_CR12","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1097\/OPX.0000000000000889","volume":"93","author":"P Kang","year":"2016","unstructured":"Kang P, Swarbrick H. The influence of different OK lens designs on peripheral refraction. Optom Vis Sci. 2016;93(9):1112\u20139.","journal-title":"Optom Vis Sci"},{"issue":"3","key":"453_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2024.102136","volume":"47","author":"J Wu","year":"2024","unstructured":"Wu J, Zhang X, Wang L, Zhang P, Guo X, Xie P. Altering optical zone diameter, reverse curve width, and compression factor: impacts on visual performance and axial elongation in orthokeratology. Contact Lens Anterior Eye. 2024;47(3):102136.","journal-title":"Contact Lens Anterior Eye"},{"issue":"3","key":"453_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2023.101814","volume":"46","author":"T Liu","year":"2023","unstructured":"Liu T, Ma W, Wang J, Yang B, Dong G, Chen C, et al. The effects of base curve aspheric orthokeratology lenses on corneal topography and peripheral refraction: a randomized prospective trial. Contact Lens Anterior Eye. 2023;46(3):101814.","journal-title":"Contact Lens Anterior Eye"},{"issue":"5","key":"453_CR15","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1080\/02713683.2020.1820528","volume":"46","author":"X Yang","year":"2021","unstructured":"Yang X, Bi H, Li L, Li S, Chen S, Zhang B, et al. The effect of relative corneal refractive power shift distribution on axial length growth in myopic children undergoing orthokeratology treatment. Curr Eye Res. 2021;46(5):657\u201365.","journal-title":"Curr Eye Res"},{"key":"453_CR16","doi-asserted-by":"publisher","DOI":"10.1080\/08164622.2024.2447469","author":"H Wang","year":"2025","unstructured":"Wang H, Li J, Zhang J, Liu X, Guo H. Comparison of spectacle lenses with highly aspherical lenslets versus orthokeratology for the management of axial length elongation. Clin Exp Optom. 2025. https:\/\/doi.org\/10.1080\/08164622.2024.2447469.","journal-title":"Clin Exp Optom"},{"issue":"6","key":"453_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2024.e27562","volume":"10","author":"A Wang","year":"2024","unstructured":"Wang A, Zang W, Shen L, Gao L, Yang C. Comparison of three VST orthokeratology lenses in axial length growth and average corneal reshaping in myopia children: a retrospective self-controlled study. Heliyon. 2024;10(6):e27562.","journal-title":"Heliyon"},{"issue":"6","key":"453_CR18","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1111\/opo.13213","volume":"43","author":"T Liu","year":"2023","unstructured":"Liu T, Chen C, Ma W, Yang B, Wang X, Liu L. One-year results for myopia control with aspheric base curve orthokeratology lenses: a prospective randomised clinical trial. Ophthalmic Physiol Opt. 2023;43(6):1469\u201377.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"6","key":"453_CR19","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1111\/opo.13347","volume":"44","author":"Y Zhou","year":"2024","unstructured":"Zhou Y, Li H, Hao J, Pan W, Yang Z, Lan W. The efficacy of orthokeratology lenses with smaller back optic zone diameter in myopia control. A meta-analysis. Ophthalmic Physiol Opt. 2024;44(6):1215\u201323.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"1","key":"453_CR20","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1186\/s12886-022-02396-w","volume":"22","author":"W Lin","year":"2022","unstructured":"Lin W, Gu T, Bi H, Du B, Zhang B, Wei R. The treatment zone decentration and corneal refractive profile changes in children undergoing orthokeratology treatment. BMC Ophthalmol. 2022;22(1):177.","journal-title":"BMC Ophthalmol"},{"issue":"5","key":"453_CR21","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1111\/opo.12996","volume":"42","author":"X Li","year":"2022","unstructured":"Li X, Huang Y, Zhang J, Ding C, Chen Y, Chen H, et al. Treatment zone decentration promotes retinal reshaping in Chinese myopic children wearing orthokeratology lenses. Ophthalmic Physiol Opt. 2022;42(5):1124\u201332.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"4","key":"453_CR22","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1097\/OPX.0000000000001888","volume":"99","author":"Z Zhang","year":"2022","unstructured":"Zhang Z, Chen Z, Zhou J, Paun\u00e9 J, Xue F, Zeng L, et al. The effect of lens design on corneal power distribution in orthokeratology. Optom Vis Sci. 2022;99(4):363\u201371.","journal-title":"Optom Vis Sci"},{"issue":"11","key":"453_CR23","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1136\/bjophthalmol-2018-312933","volume":"103","author":"Y Hu","year":"2019","unstructured":"Hu Y, Wen C, Li Z, Zhao W, Ding X, Yang X. Areal summed corneal power shift is an important determinant for axial length elongation in myopic children treated with overnight orthokeratology. Br J Ophthalmol. 2019;103(11):1571\u20135.","journal-title":"Br J Ophthalmol"},{"issue":"5","key":"453_CR24","first-page":"705","volume":"39","author":"T Oshika","year":"1998","unstructured":"Oshika T, Tomidokoro A, Maruo K, Tokunaga T, Miyata N. Quantitative evaluation of irregular astigmatism by Fourier series harmonic analysis of videokeratography data. Invest Ophthalmol Vis Sci. 1998;39(5):705\u20139.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"11","key":"453_CR25","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1097\/00006324-199511000-00006","volume":"72","author":"TW Raasch","year":"1995","unstructured":"Raasch TW. Corneal topography and irregular astigmatism. Optom Vis Sci. 1995;72(11):809\u201315.","journal-title":"Optom Vis Sci"},{"issue":"11","key":"453_CR26","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1080\/02713683.2021.1917619","volume":"46","author":"D Wang","year":"2021","unstructured":"Wang D, Wen D, Zhang B, Lin W, Liu G, Du B, et al. The association between Fourier parameters and clinical parameters in myopic children undergoing orthokeratology. Curr Eye Res. 2021;46(11):1637\u201345.","journal-title":"Curr Eye Res"},{"issue":"6","key":"453_CR27","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.7.6.17","volume":"7","author":"J Wang","year":"2018","unstructured":"Wang J, Yang D, Bi H, Du B, Lin W, Gu T, et al. A new method to analyze the relative corneal refractive power and its association to myopic progression control with orthokeratology. Transl Vis Sci Technol. 2018;7(6):17.","journal-title":"Transl Vis Sci Technol"},{"issue":"3","key":"453_CR28","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1167\/iovs.66.3.29","volume":"66","author":"T Wang","year":"2025","unstructured":"Wang T, Chen X, Li M, Bi H, Yang X, Sun M, et al. A novel model for cornea power shift in eyes wearing orthokeratology lenses with different back optic zone diameters for myopia control. Invest Ophthalmol Vis Sci. 2025;66(3):29.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"11","key":"453_CR29","doi-asserted-by":"publisher","first-page":"7077","DOI":"10.1167\/iovs.12-10565","volume":"53","author":"P Cho","year":"2012","unstructured":"Cho P, Cheung SW. Retardation of Myopia in Orthokeratology (ROMIO) study: a 2-year randomized clinical trial. Invest Ophthalmol Vis Sci. 2012;53(11):7077\u201385.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"453_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2020.100923","volume":"83","author":"NA Brennan","year":"2021","unstructured":"Brennan NA, Toubouti YM, Cheng X, Bullimore MA. Efficacy in myopia control. Prog Retin Eye Res. 2021;83:100923.","journal-title":"Prog Retin Eye Res"},{"issue":"10 Suppl 1","key":"453_CR31","doi-asserted-by":"publisher","first-page":"S59","DOI":"10.1097\/01.ico.0000247215.08886.46","volume":"25","author":"T Hiraoka","year":"2006","unstructured":"Hiraoka T, Okamoto F, Kaji Y, Oshika T. Optical quality of the cornea after overnight orthokeratology. Cornea. 2006;25(10 Suppl 1):S59-63.","journal-title":"Cornea"},{"issue":"3","key":"453_CR32","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1097\/ICL.0000000000000559","volume":"45","author":"S Koh","year":"2019","unstructured":"Koh S, Maeda N, Ogawa M, Asonuma S, Takai Y, Maruyama K, et al. Fourier analysis of corneal irregular astigmatism due to the anterior corneal surface in dry eye. Eye Contact Lens. 2019;45(3):188\u201394.","journal-title":"Eye Contact Lens"},{"issue":"12","key":"453_CR33","doi-asserted-by":"publisher","first-page":"1536","DOI":"10.1097\/ICO.0000000000002029","volume":"38","author":"H Sideroudi","year":"2019","unstructured":"Sideroudi H, Sekundo W, Kozobolis V, Messerschmidt-Roth A, Lazaridis A. Fourier analysis of corneal irregular astigmatism after small incision lenticule extraction and comparison to femtosecond laser-assisted laser in situ keratomileusis. Cornea. 2019;38(12):1536\u201342.","journal-title":"Cornea"},{"issue":"1","key":"453_CR34","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1186\/s12886-021-02123-x","volume":"21","author":"W Lin","year":"2021","unstructured":"Lin W, Li N, Gu T, Tang C, Liu G, Du B, et al. The treatment zone size and its decentration influence axial elongation in children with orthokeratology treatment. BMC Ophthalmol. 2021;21(1):362.","journal-title":"BMC Ophthalmol"},{"issue":"6","key":"453_CR35","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1111\/opo.13208","volume":"43","author":"B Guo","year":"2023","unstructured":"Guo B, Cheung SW, Kojima R, Cho P. Variation of Orthokeratology Lens Treatment Zone (VOLTZ) study: a 2-year randomised clinical trial. Ophthalmic Physiol Opt. 2023;43(6):1449\u201361.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"5","key":"453_CR36","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.13.5.12","volume":"13","author":"X Chen","year":"2024","unstructured":"Chen X, Guo Y, Bi H, Liu X, Wu Y, Wang T, et al. The impact of back optic zone design in orthokeratology on visual performance. Transl Vis Sci Technol. 2024;13(5):12.","journal-title":"Transl Vis Sci Technol"}],"container-title":["Eye and Vision"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-025-00453-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40662-025-00453-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-025-00453-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T15:02:33Z","timestamp":1759071753000},"score":1,"resource":{"primary":{"URL":"https:\/\/eandv.biomedcentral.com\/articles\/10.1186\/s40662-025-00453-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,28]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["453"],"URL":"https:\/\/doi.org\/10.1186\/s40662-025-00453-1","relation":{},"ISSN":["2326-0254"],"issn-type":[{"value":"2326-0254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,28]]},"assertion":[{"value":"3 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Ethical Review Board of Tianjin Eye Hospital (KY2023031).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no conflicts of interest to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"38"}}