{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:00:39Z","timestamp":1789948839157,"version":"4.0.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:00:00Z","timestamp":1789948800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:00:00Z","timestamp":1789948800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye and Vis"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>We aimed to develop exploratory machine learning (ML)-based predictive models for the occurrence and area of an opaque bubble layer (OBL) during small-incision lenticule extraction (SMILE) and identify associated preoperative and surgical-planning factors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective study included 216 eyes (72 with an OBL, 144 controls) that underwent SMILE at the Zhongshan Ophthalmic Center between August 2024 and August 2025, which were matched 1:2 by age and sex. Comprehensive preoperative ocular examinations were performed using a Pentacam HR camera system and standard equipment. The OBL area was quantified from intraoperative videos using ImageJ software. Fifty-four preoperative and surgical features were used to develop the ML models: 15 classification algorithms for OBL occurrence, and 19 regression algorithms for the relative OBL area. Shapley additive explanations analysis was applied for model interpretability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The Extra Trees model achieved optimal performance for predicting OBL occurrence (area under the receiver operating characteristic curve = 0.885, accuracy = 0.820). The top five key factors included femtosecond laser energy, intraocular pressure, residual stromal thickness, 10-mm corneal volume, and total astigmatism, all of which showed positive correlations. For OBL area prediction, the random forest regression model performed best in the test sets (mean absolute error = 2.89%, root mean square error = 3.37%). Corneal optical density (within the central 2-mm zone of the anterior 120-\u03bcm corneal layer) and age were negatively associated with OBL area, whereas keratoconus index showed the strongest positive association.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The ML models showed exploratory predictive ability for OBL occurrence and area during SMILE using preoperative and surgical-planning parameters. External validation and recalibration in consecutive cohorts with a natural OBL prevalence are required before clinical use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40662-026-00509-w","type":"journal-article","created":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T23:03:26Z","timestamp":1789945406000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Preoperative predictive factors for opaque bubble layer formation and area during small-incision lenticule extraction: predictive models based on machine learning"],"prefix":"10.1186","volume":"13","author":[{"given":"Chuzhi","family":"Peng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanhuan","family":"Ren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuke","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keming","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhuang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,21]]},"reference":[{"issue":"5","key":"509_CR1","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1136\/bjophthalmol-2011-300539","volume":"96","author":"D Pascolini","year":"2012","unstructured":"Pascolini D, Mariotti SP. Global estimates of visual impairment: 2010. Br J Ophthalmol. 2012;96(5):614\u20138.","journal-title":"Br J Ophthalmol"},{"issue":"10185","key":"509_CR2","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/S0140-6736(18)33209-4","volume":"393","author":"TI Kim","year":"2019","unstructured":"Kim TI, Ali\u00f3 Del Barrio JL, Wilkins M, Cochener B, Ang M. Refractive surgery. Lancet. 2019;393(10185):2085\u201398.","journal-title":"Lancet"},{"issue":"5","key":"509_CR3","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1097\/01.APO.0000580132.98159.fa","volume":"8","author":"R Shah","year":"2019","unstructured":"Shah R. History and results; indications and contraindications of SMILE, compared with LASIK. Asia Pac J Ophthalmol (Phila). 2019;8(5):371\u20136.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"1","key":"509_CR4","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-025-04171-z","volume":"25","author":"J Wang","year":"2025","unstructured":"Wang J, Cheng X, Chang W, Zhou X, Zhao Y. Long-term refractive outcomes and corneal remodeling after the SMILE surgery in patients with moderate to extra-high myopia. BMC Ophthalmol. 2025;25(1):363.","journal-title":"BMC Ophthalmol"},{"issue":"4","key":"509_CR5","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1097\/ICU.0000000000000494","volume":"29","author":"RR Krueger","year":"2018","unstructured":"Krueger RR, Meister CS. A review of small incision lenticule extraction complications. Curr Opin Ophthalmol. 2018;29(4):292\u20138.","journal-title":"Curr Opin Ophthalmol"},{"issue":"1","key":"509_CR6","doi-asserted-by":"publisher","first-page":"24","DOI":"10.3928\/1081597X-20161006-06","volume":"33","author":"G Son","year":"2017","unstructured":"Son G, Lee J, Jang C, Choi KY, Cho BJ, Lim TH. Possible risk factors and clinical effects of opaque bubble layer in small incision lenticule extraction (SMILE). J Refract Surg. 2017;33(1):24\u20139.","journal-title":"J Refract Surg"},{"issue":"12","key":"509_CR7","doi-asserted-by":"publisher","first-page":"912","DOI":"10.3928\/1081597X-20121116-01","volume":"28","author":"GD Kymionis","year":"2012","unstructured":"Kymionis GD, Kankariya VP, Plaka AD, Reinstein DZ. Femtosecond laser technology in corneal refractive surgery: a review. J Refract Surg. 2012;28(12):912\u201320.","journal-title":"J Refract Surg"},{"issue":"4","key":"509_CR8","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1007\/s00417-022-05894-1","volume":"261","author":"Z Wang","year":"2023","unstructured":"Wang Z, Cheng X, Lou X, Chen H, Lu Z, Chen H, et al. VisuMax flap 2.0: a flap plus technique to reduce incidence of an opaque bubble layer in femtosecond laser-assisted LASIK. Graefes Arch Clin Exp Ophthalmol. 2023;261(4):1187\u201394.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"1","key":"509_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02524-6","volume":"22","author":"X He","year":"2022","unstructured":"He X, Li SM, Zhai C, Zhang L, Wang Y, Song X. Flap-making patterns and corneal characteristics influence opaque bubble layer occurrence in femtosecond laser-assisted laser in situ keratomileusis. BMC Ophthalmol. 2022;22(1):300.","journal-title":"BMC Ophthalmol"},{"issue":"5","key":"509_CR10","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1007\/s10792-017-0692-2","volume":"38","author":"J Ma","year":"2018","unstructured":"Ma J, Wang Y, Li L, Zhang J. Corneal thickness, residual stromal thickness, and its effect on opaque bubble layer in small-incision lenticule extraction. Int Ophthalmol. 2018;38(5):2013\u201320.","journal-title":"Int Ophthalmol"},{"key":"509_CR11","doi-asserted-by":"publisher","first-page":"1156677","DOI":"10.3389\/fmed.2023.1156677","volume":"10","author":"S Yang","year":"2023","unstructured":"Yang S, Wang H, Chen Z, Li Y, Chen Y, Long Q. Possible risk factors of opaque bubble layer and its effect on high-order aberrations after small incision lenticule extraction. Front Med (Lausanne). 2023;10:1156677.","journal-title":"Front Med (Lausanne)"},{"issue":"9","key":"509_CR12","doi-asserted-by":"publisher","first-page":"592","DOI":"10.3928\/1081597X-20200720-02","volume":"36","author":"D Wu","year":"2020","unstructured":"Wu D, Li B, Huang M, Fang X. Influence of cap thickness on opaque bubble layer formation in SMILE: 110 versus 140 \u00b5m. J Refract Surg. 2020;36(9):592\u20136.","journal-title":"J Refract Surg"},{"key":"509_CR13","doi-asserted-by":"publisher","first-page":"1487482","DOI":"10.3389\/fcell.2024.1487482","volume":"12","author":"Z Zhu","year":"2024","unstructured":"Zhu Z, Zhang X, Wang Q, Xiong J, Xu J, Yu K, et al. Predicting an opaque bubble layer during small-incision lenticule extraction surgery based on deep learning. Front Cell Dev Biol. 2024;12:1487482.","journal-title":"Front Cell Dev Biol"},{"key":"509_CR14","doi-asserted-by":"publisher","first-page":"1598475","DOI":"10.3389\/fcell.2025.1598475","volume":"13","author":"Z Zhu","year":"2025","unstructured":"Zhu Z, Lin P, Zhong L, Wang Q, Xu J, Yu K, et al. Based on TransRes-Pix2Pix network to generate the OBL image during SMILE surgery. Front Cell Dev Biol. 2025;13:1598475.","journal-title":"Front Cell Dev Biol"},{"issue":"1","key":"509_CR15","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1186\/s12938-023-01123-w","volume":"22","author":"X Chen","year":"2023","unstructured":"Chen X, Ye Y, Yao H, Liu C, He A, Hou X, et al. Predicting post-operative vault and optimal implantable collamer lens size using machine learning based on various ophthalmic device combinations. Biomed Eng Online. 2023;22(1):59.","journal-title":"Biomed Eng Online"},{"issue":"11","key":"509_CR16","doi-asserted-by":"publisher","first-page":"1784","DOI":"10.1016\/j.jcrs.2006.08.027","volume":"32","author":"N Morishige","year":"2006","unstructured":"Morishige N, Petroll MW, Nishida T, Kenney CM, Jester JV. Noninvasive corneal stromal collagen imaging using two-photon-generated second-harmonic signals. J Cataract Refract Surg. 2006;32(11):1784\u201391.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"509_CR17","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1167\/iovs.06-1177","volume":"48","author":"N Morishige","year":"2007","unstructured":"Morishige N, Wahlert AJ, Kenney MC, Brown DJ, Kawamoto K, Chikama T, et al. Second-harmonic imaging microscopy of normal human and keratoconus cornea. Invest Ophthalmol Vis Sci. 2007;48(3):1087\u201394.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"12","key":"509_CR18","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0114437","volume":"9","author":"N Tinne","year":"2014","unstructured":"Tinne N, Kaune B, Kr\u00fcger A, Ripken T. Interaction mechanisms of cavitation bubbles induced by spatially and temporally separated FS-laser pulses. PLoS One. 2014;9(12):e114437.","journal-title":"PLoS ONE"},{"key":"509_CR19","doi-asserted-by":"publisher","first-page":"8422747","DOI":"10.1155\/2024\/8422747","volume":"2024","author":"Z Wu","year":"2024","unstructured":"Wu Z, Zhang Y, Li Y, Yang F, Su X, Gao Y, et al. Correlation between corneal volume and corneal biomechanics and corneal volume significance in staging and diagnosing keratoconus. J Ophthalmol. 2024;2024:8422747.","journal-title":"J Ophthalmol"},{"key":"509_CR20","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.ajo.2024.08.027","volume":"269","author":"Y Xu","year":"2025","unstructured":"Xu Y, Ye Y, Chen Z, Xu J, Yang Y, Zhang Y, et al. The impact of intraocular pressure changes on corneal biomechanics in primary open-angle glaucoma. Am J Ophthalmol. 2025;269:216\u201325.","journal-title":"Am J Ophthalmol"},{"key":"509_CR21","doi-asserted-by":"publisher","first-page":"1144455","DOI":"10.3389\/fbioe.2023.1144455","volume":"11","author":"Y He","year":"2023","unstructured":"He Y, Ma BS, Zeng JH, Ma DJ. Corneal optical density: structural basis, measurements, influencing factors, and roles in refractive surgery. Front Bioeng Biotechnol. 2023;11:1144455.","journal-title":"Front Bioeng Biotechnol"}],"container-title":["Eye and Vision"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-026-00509-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40662-026-00509-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40662-026-00509-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T23:03:27Z","timestamp":1789945407000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40662-026-00509-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,21]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["509"],"URL":"https:\/\/doi.org\/10.1186\/s40662-026-00509-w","relation":{},"ISSN":["2326-0254"],"issn-type":[{"value":"2326-0254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,21]]},"assertion":[{"value":"13 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All study procedures were conducted in accordance with the World Medical Association\u2019s Declaration of Helsinki tenets. Ethical approval was obtained from the Ethics Committee of the Zhongshan Ophthalmic Center (Approval No. 2023KYPJ332). The requirement for informed consent was waived by the Ethics Committee owing to the retrospective nature of the study.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"39"}}