{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T22:16:51Z","timestamp":1782425811961,"version":"3.54.5"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,26]],"date-time":"2021-04-26T00:00:00Z","timestamp":1619395200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,4,26]],"date-time":"2021-04-26T00:00:00Z","timestamp":1619395200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Oral Reconstruction Foundation, Basel, CH","award":["OR41305-part2"],"award-info":[{"award-number":["OR41305-part2"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Implant Dent"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>An implant prosthesis aims to ensure the best possible rehabilitation of function and esthetics following tooth loss. Template-guided insertion is used to achieve an optimal position of the implant with regard to prosthetic restorability, bone availability, and condition of the surrounding soft tissues. The accuracy of template-guided implant placement is subject to various influencing factors.<\/jats:p>\n                <jats:p>The clinically achievable accuracy depending on the macro design of the implant body was investigated in this prospective clinical study.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Material and methods<\/jats:title>\n                <jats:p>In this prospective clinical study, 20 implants were placed in 20 patients. The implant had a pronounced conical outer geometry (Conelog ProgressiveLine, Camlog Wimsheim, Germany). Data from a study using an implant with a distinct cylindrical outer geometry were used as a comparison group (Conelog ScrewLine, Camlog, Wimsheim, Germany). The clinically achieved implant position was compared with the planned position.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The evaluation of the two-dimensional deviations in direction resulted in the following mean values (standard deviation) at the shoulder: 0.42\u2009mm (0.33) in the buccolingual direction, 0.27\u2009mm (0.25) in the mesiodistal direction, and 0.68\u2009mm (0.55) in the apicocoronal direction. The mean angular deviation was 4.1\u00b0 (2.3). The three-dimensional (3D) deviation was 0.94\u2009mm (0.53) at the shoulder and 1.36\u2009mm (0.62) at the apex of the implant.<\/jats:p>\n                <jats:p>Significant differences between implants with different macro designs were found in the apicocoronal direction. In connection to this, a significant 3D deviation was found at the implant shoulder.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Significant differences in height were found between the groups. The study had shown that the macro design of an implant has no influence on accuracy in all other directions. Overall, the implants showed a high level of accuracy and a low variation in values. The values were in the range determined by the template-guided insertion system in numerous other investigations. This provides good predictability of prosthetic rehabilitation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Trial registration<\/jats:title>\n                <jats:p>German Register for Clinical Studies (DRKS-ID: <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.drks.de\/drks_web\/navigate.do?navigationId=trial.HTML&amp;TRIAL_ID=DRKS00018939\">DRKS000018939<\/jats:ext-link>). Date of registration: November 11, 2019.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40729-021-00320-3","type":"journal-article","created":{"date-parts":[[2021,4,25]],"date-time":"2021-04-25T23:03:33Z","timestamp":1619391813000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study"],"prefix":"10.1186","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3593-7074","authenticated-orcid":false,"given":"Sigmar","family":"Schnutenhaus","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cornelia","family":"Edelmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heike","family":"Rudolph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,26]]},"reference":[{"key":"320_CR1","first-page":"Doc15","volume":"5","author":"E Naziri","year":"2016","unstructured":"Naziri E, Schramm A, Wilde F. Accuracy of computer-assisted implant placement with insertion templates. GMS Interdiscip Plast Reconstr Surg DGPW. 2016;5:Doc15.","journal-title":"GMS Interdiscip Plast Reconstr Surg DGPW"},{"issue":"3","key":"320_CR2","doi-asserted-by":"publisher","first-page":"427","DOI":"10.11607\/prd.4420","volume":"40","author":"LV Stefanelli","year":"2020","unstructured":"Stefanelli LV, Mandelaris GA, DeGroot BS, Gambarini G, De Angelis F, Di Carlo S. Accuracy of a novel trace-registration method for dynamic navigation surgery. Int J Periodontics Restorative Dent. 2020;40(3):427\u201335. https:\/\/doi.org\/10.11607\/prd.4420.","journal-title":"Int J Periodontics Restorative Dent."},{"issue":"4","key":"320_CR3","doi-asserted-by":"publisher","first-page":"704","DOI":"10.3390\/jcm10040704","volume":"10","author":"S Schnutenhaus","year":"2021","unstructured":"Schnutenhaus S, Edelmann C, Knipper A, Luthardt RG. Accuracy of dynamic computer-assisted implant placement: a systematic review and meta-analysis of clinical and in vitro studies. J Clin Med. 2021;10(4):704. https:\/\/doi.org\/10.3390\/jcm10040704.","journal-title":"J Clin Med."},{"issue":"4","key":"320_CR4","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1111\/j.1600-0501.2011.02337.x","volume":"23","author":"A Behneke","year":"2012","unstructured":"Behneke A, Burwinkel M, Behneke N. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 2012;23(4):416\u201323. https:\/\/doi.org\/10.1111\/j.1600-0501.2011.02337.x.","journal-title":"Clin Oral Implants Res."},{"issue":"7","key":"320_CR5","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.jcms.2009.10.023","volume":"38","author":"HJ Nickenig","year":"2010","unstructured":"Nickenig HJ, Wichmann M, Hamel J, Schlegel KA, Eitner S. Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method - a combined in vivo - in vitro technique using cone-beam CT (Part II). J Craniomaxillofac Surg. 2010;38(7):488\u201393. https:\/\/doi.org\/10.1016\/j.jcms.2009.10.023.","journal-title":"J Craniomaxillofac Surg."},{"issue":"11","key":"320_CR6","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1111\/clr.12460","volume":"26","author":"M Vercruyssen","year":"2015","unstructured":"Vercruyssen M, Coucke W, Naert I, Jacobs R, Teughels W, Quirynen M. Depth and lateral deviations in guided implant surgery: an RCT comparing guided surgery with mental navigation or the use of a pilot-drill template. Clin Oral Implants Res. 2015;26(11):1315\u201320. https:\/\/doi.org\/10.1111\/clr.12460.","journal-title":"Clin Oral Implants Res."},{"issue":"7","key":"320_CR7","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1111\/jcpe.12231","volume":"41","author":"M Vercruyssen","year":"2014","unstructured":"Vercruyssen M, Cox C, Coucke W, Naert I, Jacobs R, Quirynen M. A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template. J Clin Periodontol. 2014;41(7):717\u201323. https:\/\/doi.org\/10.1111\/jcpe.12231.","journal-title":"J Clin Periodontol."},{"issue":"Suppl 16","key":"320_CR8","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1111\/clr.13346","volume":"29","author":"A Tahmaseb","year":"2018","unstructured":"Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29(Suppl 16):416\u201335. https:\/\/doi.org\/10.1111\/clr.13346.","journal-title":"Clin Oral Implants Res."},{"issue":"5","key":"320_CR9","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1111\/clr.13578","volume":"31","author":"E Varga Jr","year":"2020","unstructured":"Varga E Jr, Antal M, Major L, Kiscsatari R, Braunitzer G, Piffko J. Guidance means accuracy: a randomized clinical trial on freehand versus guided dental implantation. Clin Oral Implants Res. 2020;31(5):417\u201330. https:\/\/doi.org\/10.1111\/clr.13578.","journal-title":"Clin Oral Implants Res."},{"issue":"6","key":"320_CR10","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1111\/jcpe.12897","volume":"45","author":"F Younes","year":"2018","unstructured":"Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018;45(6):721\u201332. https:\/\/doi.org\/10.1111\/jcpe.12897.","journal-title":"J Clin Periodontol."},{"issue":"3","key":"320_CR11","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.prosdent.2018.08.009","volume":"121","author":"B Gjelvold","year":"2019","unstructured":"Gjelvold B, Mahmood DJH, Wennerberg A. Accuracy of surgical guides from 2 different desktop 3D printers for computed tomography-guided surgery. J Prosthet Dent. 2019;121(3):498\u2013503. https:\/\/doi.org\/10.1016\/j.prosdent.2018.08.009.","journal-title":"J Prosthet Dent."},{"issue":"6","key":"320_CR12","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1111\/jopr.13161","volume":"29","author":"P Henprasert","year":"2020","unstructured":"Henprasert P, Dawson DV, El-Kerdani T, Song X, Couso-Queiruga E, Holloway JA. Comparison of the accuracy of implant position using surgical guides fabricated by additive and subtractive techniques. J Prosthodont. 2020;29(6):534\u201341. https:\/\/doi.org\/10.1111\/jopr.13161.","journal-title":"J Prosthodont."},{"issue":"8","key":"320_CR13","doi-asserted-by":"publisher","first-page":"2322","DOI":"10.3390\/jcm9082322","volume":"9","author":"S Pieralli","year":"2020","unstructured":"Pieralli S, Spies BC, Hromadnik V, Nicic R, Beuer F, Wesemann C. How accurate is oral implant installation using surgical guides printed from a degradable and steam-sterilized biopolymer? J Clin Med. 2020;9(8):2322. https:\/\/doi.org\/10.3390\/jcm9082322.","journal-title":"J Clin Med."},{"issue":"10","key":"320_CR14","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1016\/j.ijom.2020.03.007","volume":"49","author":"M Cassetta","year":"2020","unstructured":"Cassetta M, Altieri F, Giansanti M, Bellardini M, Brandetti G, Piccoli L. Is there a learning curve in static computer-assisted implant surgery? A prospective clinical study. Int J Oral Maxillofac Surg. 2020;49(10):1335\u201342. https:\/\/doi.org\/10.1016\/j.ijom.2020.03.007.","journal-title":"Int J Oral Maxillofac Surg."},{"issue":"1","key":"320_CR15","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.ijom.2013.06.012","volume":"43","author":"M Cassetta","year":"2014","unstructured":"Cassetta M, Di Mambro A, Giansanti M, Stefanelli LV, Barbato E. How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide? Int J Oral Maxillofac Surg. 2014;43(1):85\u201392. https:\/\/doi.org\/10.1016\/j.ijom.2013.06.012.","journal-title":"Int J Oral Maxillofac Surg."},{"issue":"6","key":"320_CR16","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1111\/cid.12230","volume":"17","author":"LM Verhamme","year":"2015","unstructured":"Verhamme LM, Meijer GJ, Berge SJ, Soehardi RA, Xi T, de Haan AF, et al. An accuracy study of computer-planned implant placement in the augmented maxilla using mucosa-supported surgical templates. Clin Implant Dent Relat Res. 2015;17(6):1154\u201363. https:\/\/doi.org\/10.1111\/cid.12230.","journal-title":"Clin Implant Dent Relat Res."},{"issue":"11","key":"320_CR17","doi-asserted-by":"publisher","first-page":"2259","DOI":"10.1016\/j.joms.2019.05.017","volume":"77","author":"Y Liang","year":"2019","unstructured":"Liang Y, Yuan S, Huan J, Zhang Y, Fang C, Li J. In vitro experimental study of the effect of adjusting the guide sleeve height and using a visual direction-indicating guide on implantation accuracy. J Oral Maxillofac Surg. 2019;77(11):2259\u201368. https:\/\/doi.org\/10.1016\/j.joms.2019.05.017.","journal-title":"J Oral Maxillofac Surg."},{"key":"320_CR18","doi-asserted-by":"publisher","unstructured":"Tallarico M, Martinolli M, Kim Y, Cocchi F, Meloni SM, Alushi A, et al. Accuracy of computer-assisted template-based implant placement using two different surgical templates designed with or without metallic sleeves: a randomized controlled trial. Dent J (Basel). 2019;7(2).\u00a0https:\/\/doi.org\/10.3390\/dj7020041.","DOI":"10.3390\/dj7020041"},{"issue":"Suppl 1","key":"320_CR19","doi-asserted-by":"publisher","first-page":"e177","DOI":"10.1111\/cid.12152","volume":"17","author":"S Kuhl","year":"2015","unstructured":"Kuhl S, Payer M, Zitzmann NU, Lambrecht JT, Filippi A. Technical accuracy of printed surgical templates for guided implant surgery with the coDiagnostiX software. Clin Implant Dent Relat Res. 2015;17(Suppl 1):e177\u201382. https:\/\/doi.org\/10.1111\/cid.12152.","journal-title":"Clin Implant Dent Relat Res."},{"issue":"3","key":"320_CR20","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/S0022-3913(12)60145-0","volume":"108","author":"SK Turbush","year":"2012","unstructured":"Turbush SK, Turkyilmaz I. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study. J Prosthet Dent. 2012;108(3):181\u20138. https:\/\/doi.org\/10.1016\/S0022-3913(12)60145-0.","journal-title":"J Prosthet Dent."},{"issue":"6","key":"320_CR21","first-page":"8442","volume":"8","author":"W Geng","year":"2015","unstructured":"Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design\/computer-aided manufacturing surgical guides for dental implant placement. Int J Clin Exp Med. 2015;8(6):8442\u20139.","journal-title":"Int J Clin Exp Med."},{"issue":"1","key":"320_CR22","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.jebdp.2017.07.007","volume":"18","author":"W Zhou","year":"2018","unstructured":"Zhou W, Liu Z, Song L, Kuo CL, Shafer DM. Clinical factors affecting the accuracy of guided implant surgery-a systematic review and meta-analysis. J Evid Based Dent Pract. 2018;18(1):28\u201340. https:\/\/doi.org\/10.1016\/j.jebdp.2017.07.007.","journal-title":"J Evid Based Dent Pract."},{"issue":"6","key":"320_CR23","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1111\/cid.12847","volume":"21","author":"J Li","year":"2019","unstructured":"Li J, Chen Z, Chan HL, Sinjab K, Yu H, Wang HL. Does flap opening or not influence the accuracy of semi-guided implant placement in partially edentulous sites? Clin Implant Dent Relat Res. 2019;21(6):1253\u201361. https:\/\/doi.org\/10.1111\/cid.12847.","journal-title":"Clin Implant Dent Relat Res."},{"issue":"1","key":"320_CR24","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1186\/s40729-020-00249-z","volume":"6","author":"RH Putra","year":"2020","unstructured":"Putra RH, Yoda N, Iikubo M, Kataoka Y, Yamauchi K, Koyama S, et al. Influence of bone condition on implant placement accuracy with computer-guided surgery. Int J Implant Dent. 2020;6(1):62. https:\/\/doi.org\/10.1186\/s40729-020-00249-z.","journal-title":"Int J Implant Dent."},{"issue":"1","key":"320_CR25","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1186\/s12903-020-01155-x","volume":"20","author":"S Schnutenhaus","year":"2020","unstructured":"Schnutenhaus S, Brunken L, Edelmann C, Dreyhaupt J, Rudolph H, Luthardt RG. Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial. BMC Oral Health. 2020;20(1):178. https:\/\/doi.org\/10.1186\/s12903-020-01155-x.","journal-title":"BMC Oral Health."},{"issue":"6","key":"320_CR26","doi-asserted-by":"publisher","first-page":"2363","DOI":"10.1007\/s00784-018-2339-8","volume":"22","author":"S Schnutenhaus","year":"2018","unstructured":"Schnutenhaus S, Edelmann C, Rudolph H, Dreyhaupt J, Luthardt RG. 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study. Clin Oral Investig. 2018;22(6):2363\u201372. https:\/\/doi.org\/10.1007\/s00784-018-2339-8.","journal-title":"Clin Oral Investig."},{"issue":"6","key":"320_CR27","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1016\/j.prosdent.2019.05.027","volume":"123","author":"M Yeung","year":"2020","unstructured":"Yeung M, Abdulmajeed A, Carrico CK, Deeb GR, Bencharit S. Accuracy and precision of 3D-printed implant surgical guides with different implant systems: an in vitro study. J Prosthet Dent. 2020;123(6):821\u20138. https:\/\/doi.org\/10.1016\/j.prosdent.2019.05.027.","journal-title":"J Prosthet Dent."},{"issue":"4","key":"320_CR28","doi-asserted-by":"publisher","first-page":"e72","DOI":"10.1016\/j.oooo.2015.12.012","volume":"121","author":"S Schnutenhaus","year":"2016","unstructured":"Schnutenhaus S, Edelmann C, Rudolph H, Luthardt RG. Retrospective study to determine the accuracy of template-guided implant placement using a novel nonradiologic evaluation method. Oral Surg Oral Med Oral Pathol Oral Radiol. 2016;121(4):e72\u20139. https:\/\/doi.org\/10.1016\/j.oooo.2015.12.012.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol."},{"issue":"Suppl","key":"320_CR29","doi-asserted-by":"publisher","first-page":"25","DOI":"10.11607\/jomi.2014suppl.g1.2","volume":"29","author":"A Tahmaseb","year":"2014","unstructured":"Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29(Suppl):25\u201342. https:\/\/doi.org\/10.11607\/jomi.2014suppl.g1.2.","journal-title":"Int J Oral Maxillofac Implants."},{"issue":"2","key":"320_CR30","first-page":"97","volume":"21","author":"S Schnutenhaus","year":"2018","unstructured":"Schnutenhaus S, von Koenigsmarck V, Blender S, Ambrosius L, Luthardt RG, Rudolph H. Precision of sleeveless 3D drill guides for insertion of one-piece ceramic implants: a prospective clinical trial. Int J Comput Dent. 2018;21(2):97\u2013105.","journal-title":"Int J Comput Dent."},{"issue":"4","key":"320_CR31","doi-asserted-by":"publisher","first-page":"e111","DOI":"10.11607\/prd.4147","volume":"39","author":"D Schneider","year":"2019","unstructured":"Schneider D, Sancho-Puchades M, Mir-Mari J, Muhlemann S, Jung R, Hammerle C. A randomized controlled clinical trial comparing conventional and computer-assisted implant planning and placement in partially edentulous patients. Part 4: accuracy of implant placement. Int J Periodontics Restorative Dent. 2019;39(4):e111\u2013e22. https:\/\/doi.org\/10.11607\/prd.4147.","journal-title":"Int J Periodontics Restorative Dent."},{"key":"320_CR32","doi-asserted-by":"publisher","unstructured":"Sun TM, Lee HE, Lan TH. Comparing accuracy of implant installation with a Navigation System (NS), a Laboratory Guide (LG), NS with LG, and Freehand Drilling. Int J Environ Res Public Health. 2020;17(6).\u00a0https:\/\/doi.org\/10.3390\/ijerph17062107.","DOI":"10.3390\/ijerph17062107"},{"issue":"3","key":"320_CR33","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1111\/clr.13563","volume":"31","author":"CA Aydemir","year":"2020","unstructured":"Aydemir CA, Arisan V. Accuracy of dental implant placement via dynamic navigation or the freehand method: a split-mouth randomized controlled clinical trial. Clin Oral Implants Res. 2020;31(3):255\u201363. https:\/\/doi.org\/10.1111\/clr.13563.","journal-title":"Clin Oral Implants Res."},{"key":"320_CR34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.aanat.2019.04.005","volume":"225","author":"J Gargallo-Albiol","year":"2019","unstructured":"Gargallo-Albiol J, Barootchi S, Salomo-Coll O, Wang HL. Advantages and disadvantages of implant navigation surgery. A systematic review. Ann Anat. 2019;225:1\u201310. https:\/\/doi.org\/10.1016\/j.aanat.2019.04.005.","journal-title":"Ann Anat."},{"issue":"1","key":"320_CR35","doi-asserted-by":"publisher","first-page":"101","DOI":"10.11607\/jomi.5556","volume":"33","author":"F Bover-Ramos","year":"2018","unstructured":"Bover-Ramos F, Vina-Almunia J, Cervera-Ballester J, Penarrocha-Diago M, Garcia-Mira B. Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. Int J Oral Maxillofac Implants. 2018;33(1):101\u201315. https:\/\/doi.org\/10.11607\/jomi.5556.","journal-title":"Int J Oral Maxillofac Implants."},{"issue":"1","key":"320_CR36","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1097\/ID.0000000000000853","volume":"28","author":"DA Sigcho Lopez","year":"2019","unstructured":"Sigcho Lopez DA, Garcia I, Da Silva SG, Cruz LD. Potential deviation factors affecting stereolithographic surgical guides: a systematic review. Implant Dent. 2019;28(1):68\u201373. https:\/\/doi.org\/10.1097\/ID.0000000000000853.","journal-title":"Implant Dent."},{"issue":"3","key":"320_CR37","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.prosdent.2019.02.007","volume":"122","author":"L Chen","year":"2019","unstructured":"Chen L, Lin WS, Polido WD, Eckert GJ, Morton D. Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates. J Prosthet Dent. 2019;122(3):309\u201314. https:\/\/doi.org\/10.1016\/j.prosdent.2019.02.007.","journal-title":"J Prosthet Dent."},{"key":"320_CR38","doi-asserted-by":"publisher","unstructured":"Herschdorfer L, Negreiros WM, Gallucci GO, Hamilton A. Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: an in vitro study. J Prosthet Dent. 2020. https:\/\/doi.org\/10.1016\/j.prosdent.2020.03.017.","DOI":"10.1016\/j.prosdent.2020.03.017"},{"issue":"5","key":"320_CR39","doi-asserted-by":"publisher","first-page":"931","DOI":"10.11607\/jomi.8186","volume":"35","author":"J Abduo","year":"2020","unstructured":"Abduo J, Lau D. Effect of manufacturing technique on the accuracy of surgical guides for static computer-aided implant surgery. Int J Oral Maxillofac Implants. 2020;35(5):931\u20138. https:\/\/doi.org\/10.11607\/jomi.8186.","journal-title":"Int J Oral Maxillofac Implants."},{"issue":"1","key":"320_CR40","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/s40729-020-0205-3","volume":"6","author":"J Abduo","year":"2020","unstructured":"Abduo J, Lau D. Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols. Int J Implant Dent. 2020;6(1):10. https:\/\/doi.org\/10.1186\/s40729-020-0205-3.","journal-title":"Int J Implant Dent."}],"container-title":["International Journal of Implant Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-021-00320-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40729-021-00320-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-021-00320-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,25]],"date-time":"2021-04-25T23:14:39Z","timestamp":1619392479000},"score":1,"resource":{"primary":{"URL":"https:\/\/journalimplantdent.springeropen.com\/articles\/10.1186\/s40729-021-00320-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,26]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["320"],"URL":"https:\/\/doi.org\/10.1186\/s40729-021-00320-3","relation":{},"ISSN":["2198-4034"],"issn-type":[{"value":"2198-4034","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,26]]},"assertion":[{"value":"6 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was registered with the German Register for Clinical Studies (DRKS-ID: DRKS000018939) prior to recruitment of patients, following approval by the responsible ethics committee of the State Medical Association of Baden-W\u00fcrttemberg, Germany (application no.: F2019-057-z).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent for participation"}},{"value":"Written consent was obtained from all patients for this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Sigmar Schnutenhaus, Cornelia Edelmann, and Heike Rudolph declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42"}}