{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T22:52:00Z","timestamp":1794955920588,"version":"4.9.1"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T00:00:00Z","timestamp":1741824000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T00:00:00Z","timestamp":1741824000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Implant Dent"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To compare cone-beam computed tomography (CBCT) with photon-counting detector computed tomography (PCD-CT) at equivalent radiation doses, focusing on qualitative and quantitative parameters relevant to dental implant surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This ex vivo comparative study of porcine specimens assessed five imaging protocols with both CBCT and PCD-CT at three effective radiation dose levels (high: 360\u00b5Sv, standard: 145\u00b5Sv, low: 20\u00b5Sv) to evaluate image quality, artifact burden, metal artifact susceptibility, and quantitative bone measurements in the mandibular region. Three blinded readers analyzed the data using a 5-point Likert scale (5\u2009=\u2009highest to 1\u2009=\u2009lowest rating) and performed linear bone measurements at implant planning sites. Statistical analysis included descriptive statistics and inter-reader reliability assessment using intraclass correlation coefficients (ICC).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Each reader evaluated 30 data sets (12 CBCT, 18 PCD-CT), with 24 implant planning sites per imaging protocol. High-dose PCD-CT demonstrated the best image quality and diagnostic interpretability (4.89\u2009\u00b1\u20090.27), followed by standard-dose PCD-CT and CBCT (4.50\u2009\u00b1\u20090.73; 4.33\u2009\u00b1\u20090.61), with low-dose protocols showing intermediate quality with higher artifact burden. In comparison to CBCT, PCD-CT demonstrated superior performance in reducing implant-induced artifacts across all protocols. Quantitative bone measurements showed minimal variability, meeting clinical precision requirements for computer-assisted implant surgery. Both qualitative (ICCs:0.70\u20130.89; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) and quantitative (ICCs:0.79\u20131; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) analyses demonstrated high reliability, regardless of the reader\u2019s experience.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>PCD-CT demonstrated superior image quality and reduced artifacts compared with CBCT at all radiation dose levels. These findings highlight PCD-CT\u2019s potential to enhance implant planning and improve clinical outcomes with reduced radiation exposure while maintaining diagnostic accuracy.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40729-025-00611-z","type":"journal-article","created":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T11:43:15Z","timestamp":1741866195000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery"],"prefix":"10.1186","volume":"11","author":[{"given":"Adib","family":"Al-Haj Husain","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Mergen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvio","family":"Valdec","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nadin","family":"Al-Haj Husain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernd","family":"Stadlinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harald","family":"Essig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Frauenfelder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Kessler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suen An Nynke","family":"Lie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hatem","family":"Alkadhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Winklhofer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,13]]},"reference":[{"key":"611_CR1","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.jdent.2019.03.008","volume":"84","author":"MS Howe","year":"2019","unstructured":"Howe MS, Keys W, Richards D. Long-term (10-year) dental implant survival: A systematic review and sensitivity meta-analysis. J Dent. 2019;84:9\u201321.","journal-title":"J Dent"},{"issue":"5","key":"611_CR2","first-page":"525","volume":"9","author":"AH Pakravan","year":"2019","unstructured":"Pakravan AH, Aghamiri SMR, Bamdadian T, Gholami M, Moshfeghi M. Dosimetry of occupational radiation around panoramic X-ray apparatus. J Biomed Phys Eng. 2019;9(5):525\u201332.","journal-title":"J Biomed Phys Eng"},{"issue":"1","key":"611_CR3","first-page":"95","volume":"10","author":"J Van Dessel","year":"2017","unstructured":"Van Dessel J, Nicolielo LF, Huang Y, Coudyzer W, Salmon B, Lambrichts I, et al. Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT. Eur J Oral Implantol. 2017;10(1):95\u2013105.","journal-title":"Eur J Oral Implantol"},{"issue":"3","key":"611_CR4","doi-asserted-by":"publisher","first-page":"665","DOI":"10.11607\/jomi.6915","volume":"34","author":"JP Dings","year":"2019","unstructured":"Dings JP, Verhamme L, Merkx MA, Xi T, Meijer GJ, Maal TJ. Reliability and accuracy of cone beam computed tomography versus conventional multidetector computed tomography for image-guided craniofacial implant planning: an in vitro study. Int J Oral Maxillofac Implants. 2019;34(3):665\u201372.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"611_CR5","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/s12903-018-0523-5","volume":"18","author":"R Jacobs","year":"2018","unstructured":"Jacobs R, Salmon B, Codari M, Hassan B, Bornstein MM. Cone beam computed tomography in implant dentistry: recommendations for clinical use. BMC Oral Health. 2018;18(1):88.","journal-title":"BMC Oral Health"},{"issue":"Suppl 16","key":"611_CR6","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1111\/clr.13142","volume":"29","author":"G Fokas","year":"2018","unstructured":"Fokas G, Vaughn VM, Scarfe WC, Bornstein MM. Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review. Clin Oral Implants Res. 2018;29(16):393\u2013415.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"611_CR7","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1111\/prd.12050","volume":"66","author":"R Jacobs","year":"2014","unstructured":"Jacobs R, Quirynen M, Bornstein MM. Neurovascular disturbances after implant surgery. Periodontol 2000. 2014;66(1):188\u2013202.","journal-title":"Periodontol 2000"},{"issue":"4","key":"611_CR8","first-page":"162","volume":"5","author":"F Javed","year":"2013","unstructured":"Javed F, Ahmed HB, Crespi R, Romanos GE. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation. Interv Med Appl Sci. 2013;5(4):162\u20137.","journal-title":"Interv Med Appl Sci"},{"key":"611_CR9","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.ejmp.2017.07.018","volume":"44","author":"V Tsapaki","year":"2017","unstructured":"Tsapaki V. Radiation protection in dental radiology - Recent advances and future directions. Phys Med. 2017;44:222\u20136.","journal-title":"Phys Med"},{"issue":"11","key":"611_CR10","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1089\/thy.2019.0105","volume":"29","author":"A Memon","year":"2019","unstructured":"Memon A, Rogers I, Paudyal P, Sundin J. Dental X-Rays and the risk of thyroid Cancer and meningioma: A systematic review and Meta-Analysis of current epidemiological evidence. Thyroid. 2019;29(11):1572\u201393.","journal-title":"Thyroid"},{"issue":"4","key":"611_CR11","doi-asserted-by":"publisher","first-page":"263","DOI":"10.5624\/isd.2015.45.4.263","volume":"45","author":"PP Jaju","year":"2015","unstructured":"Jaju PP, Jaju SP. Cone-beam computed tomography: time to move from ALARA to ALADA. Imaging Sci Dent. 2015;45(4):263\u20135.","journal-title":"Imaging Sci Dent"},{"issue":"5","key":"611_CR12","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1111\/ipd.12797","volume":"31","author":"AC Oenning","year":"2021","unstructured":"Oenning AC, Jacobs R, Salmon B. (http:\/\/www.dimitra.be) DRG. ALADAIP, beyond ALARA and towards personalized optimization for paediatric cone-beam CT. Int J Paediatr Dent. 2021;31(5):676\u20138.","journal-title":"Int J Paediatr Dent"},{"issue":"6","key":"611_CR13","doi-asserted-by":"publisher","first-page":"2573","DOI":"10.1007\/s00784-019-02907-y","volume":"23","author":"AWK Yeung","year":"2019","unstructured":"Yeung AWK, Jacobs R, Bornstein MM. Novel low-dose protocols using cone beam computed tomography in dental medicine: a review focusing on indications, limitations, and future possibilities. Clin Oral Investig. 2019;23(6):2573\u201381.","journal-title":"Clin Oral Investig"},{"key":"611_CR14","doi-asserted-by":"crossref","unstructured":"Kaaber L, Matzen LH, Schropp L, Spin-Neto R. Low-dose CBCT protocols in implant dentistry: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol. 2024.","DOI":"10.1016\/j.oooo.2024.03.013"},{"issue":"4","key":"611_CR15","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1093\/dmfr\/twae007","volume":"53","author":"ALE Carneiro","year":"2024","unstructured":"Carneiro ALE, Reis INR, Bitencourt FV, Salgado DMRA, Costa C, Spin-Neto R. Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis. Dentomaxillofac Radiol. 2024;53(4):207\u201321.","journal-title":"Dentomaxillofac Radiol"},{"issue":"9","key":"611_CR16","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1097\/RLI.0000000000000668","volume":"55","author":"H Alkadhi","year":"2020","unstructured":"Alkadhi H, Euler A. The future of computed tomography: personalized, functional, and precise. Invest Radiol. 2020;55(9):545\u201355.","journal-title":"Invest Radiol"},{"issue":"12","key":"611_CR17","doi-asserted-by":"publisher","first-page":"6389","DOI":"10.1007\/s00330-020-07321-7","volume":"30","author":"T Nakamura","year":"2020","unstructured":"Nakamura T. Dental MRI: a road beyond CBCT. Eur Radiol. 2020;30(12):6389\u201391.","journal-title":"Eur Radiol"},{"issue":"12","key":"611_CR18","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1097\/RLI.0000000000000897","volume":"57","author":"V Mergen","year":"2022","unstructured":"Mergen V, Sartoretti T, Baer-Beck M, Schmidt B, Petersilka M, Wildberger JE, et al. Ultra-High-Resolution coronary CT angiography with Photon-Counting detector CT: feasibility and image characterization. Invest Radiol. 2022;57(12):780\u20138.","journal-title":"Invest Radiol"},{"issue":"4","key":"611_CR19","doi-asserted-by":"publisher","first-page":"579","DOI":"10.3174\/ajnr.A7452","volume":"43","author":"JC Benson","year":"2022","unstructured":"Benson JC, Rajendran K, Lane JI, Diehn FE, Weber NM, Thorne JE, et al. A new frontier in Temporal bone imaging: Photon-Counting detector CT demonstrates superior visualization of critical anatomic structures at reduced radiation dose. AJNR Am J Neuroradiol. 2022;43(4):579\u201384.","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"611_CR20","doi-asserted-by":"publisher","first-page":"7125","DOI":"10.1038\/s41598-022-11281-x","volume":"12","author":"M Ruetters","year":"2022","unstructured":"Ruetters M, Sen S, Gehrig H, Bruckner T, Kim TS, Lux CJ, et al. Dental imaging using an ultra-high resolution photon-counting CT system. Sci Rep. 2022;12(1):7125.","journal-title":"Sci Rep"},{"key":"611_CR21","doi-asserted-by":"crossref","unstructured":"Zanon C, Pepe A, Cademartiri F, Bini C, Maffei E, Quaia E et al. Potential benefits of Photon-Counting CT in dental imaging: A narrative review. J Clin Med. 2024;13(8).","DOI":"10.3390\/jcm13082436"},{"key":"611_CR22","doi-asserted-by":"publisher","first-page":"104859","DOI":"10.1016\/j.jdent.2024.104859","volume":"142","author":"S Sawall","year":"2024","unstructured":"Sawall S, Maier J, Sen S, Gehrig H, Kim TS, Schlemmer HP, et al. Dental imaging in clinical photon-counting CT at a quarter of DVT dose. J Dent. 2024;142:104859.","journal-title":"J Dent"},{"issue":"1","key":"611_CR23","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1038\/s41405-021-00060-x","volume":"7","author":"L Vanden Broeke","year":"2021","unstructured":"Vanden Broeke L, Grillon M, Yeung AWK, Wu W, Tanaka R, Vardhanabhuti V. Feasibility of photon-counting spectral CT in dental applications-a comparative qualitative analysis. BDJ Open. 2021;7(1):4.","journal-title":"BDJ Open"},{"issue":"6","key":"611_CR24","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1111\/j.1601-0825.2006.01337.x","volume":"13","author":"S Wang","year":"2007","unstructured":"Wang S, Liu Y, Fang D, Shi S. The miniature pig: a useful large animal model for dental and orofacial research. Oral Dis. 2007;13(6):530\u20137.","journal-title":"Oral Dis"},{"key":"611_CR25","doi-asserted-by":"crossref","unstructured":"Romanyukha A, Folio L, Lamart S, Simon SL, Lee C, BODY, SIZE-SPECIFIC EFFECTIVE, DOSE CONVERSION COEFFICIENTS FOR CT SCANS. Radiat Prot Dosimetry. 2016;172(4):428\u201337.","DOI":"10.1093\/rpd\/ncv511"},{"key":"611_CR26","doi-asserted-by":"crossref","unstructured":"Dillinger D, Overhoff D, Froelich MF, Kaatsch HL, Booz C, Hagen A et al. Photon-Counting detector CT virtual monoenergetic images in cervical trauma Imaging-Optimization of dental metal artifacts and image quality. Diagnostics (Basel). 2024;14(6).","DOI":"10.3390\/diagnostics14060626"},{"issue":"11","key":"611_CR27","doi-asserted-by":"publisher","first-page":"7818","DOI":"10.1007\/s00330-023-09790-y","volume":"33","author":"TS Patzer","year":"2023","unstructured":"Patzer TS, Kunz AS, Huflage H, Gruschwitz P, Pannenbecker P, Afat S, et al. Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants. Eur Radiol. 2023;33(11):7818\u201329.","journal-title":"Eur Radiol"},{"key":"611_CR28","doi-asserted-by":"crossref","unstructured":"Kaaber L, Matzen LH, Spin-Neto R, Schropp L. Low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: an ex vivo study in human specimens. Clin Oral Implants Res. 2024;35(11):1394\u20131405.","DOI":"10.1111\/clr.14326"},{"issue":"2","key":"611_CR29","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u201363.","journal-title":"J Chiropr Med"},{"issue":"4","key":"611_CR30","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.adaj.2023.12.002","volume":"155","author":"E Benavides","year":"2024","unstructured":"Benavides E, Krecioch JR, Connolly RT, Allareddy T, Buchanan A, Spelic D, et al. Optimizing radiation safety in dentistry: clinical recommendations and regulatory considerations. J Am Dent Assoc. 2024;155(4):280\u2013e934.","journal-title":"J Am Dent Assoc"},{"issue":"2","key":"611_CR31","doi-asserted-by":"publisher","first-page":"75","DOI":"10.3322\/caac.21132","volume":"62","author":"MS Linet","year":"2012","unstructured":"Linet MS, Slovis TL, Miller DL, Kleinerman R, Lee C, Rajaraman P, et al. Cancer risks associated with external radiation from diagnostic imaging procedures. CA Cancer J Clin. 2012;62(2):75\u2013100.","journal-title":"CA Cancer J Clin"},{"issue":"3","key":"611_CR32","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/j.cden.2014.04.002","volume":"58","author":"MD Scherer","year":"2014","unstructured":"Scherer MD. Presurgical implant-site assessment and restoratively driven digital planning. Dent Clin North Am. 2014;58(3):561\u201395.","journal-title":"Dent Clin North Am"}],"container-title":["International Journal of Implant Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-025-00611-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40729-025-00611-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-025-00611-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T11:43:20Z","timestamp":1741866200000},"score":1,"resource":{"primary":{"URL":"https:\/\/journalimplantdent.springeropen.com\/articles\/10.1186\/s40729-025-00611-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,13]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["611"],"URL":"https:\/\/doi.org\/10.1186\/s40729-025-00611-z","relation":{},"ISSN":["2198-4034"],"issn-type":[{"value":"2198-4034","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,13]]},"assertion":[{"value":"8 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"A formal declaration of non-responsibility was provided by the Office of Animal Welfare and 3R of the University of Zurich, confirming that all experiments comply with the Swiss federal guidelines for the use of animals in experimental research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"VM, TF, and HA: Institutional grants from Bayer, Canon, Guerbet, and Siemens. HA received speaker honoraria from Siemens.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21"}}