{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T10:59:45Z","timestamp":1778583585632,"version":"3.51.4"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100014584","name":"Universit\u00e4tsmedizin der Johannes Gutenberg-Universit\u00e4t Mainz","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100014584","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Implant Dent"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To report the evaluation of in vivo retention forces after replacement of O-rings in one-piece mini dental implants (MDIs), retaining mandibular implant overdentures (IODs) with ball\/O-ring attachments during 10\u00a0years assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Twenty patients received new complete dentures, which were converted into IODs through stabilization with four MDIs (Condent GmbH; diameter: 1.8\u00a0mm) placed in the interforaminal region. Retention forces were measured at the male and female parts at baseline, 5, and 10\u00a0years using a validated strain gauge. Fourteen patients completed the 10-year follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>After 10\u00a0years, a minor but significant reduction in retention force was observed in the male part of the implant at position 44. In contrast, neither the male part at the other implant positions nor the female part at any position showed a significant decrease in retention force compared to baseline. After replacement of the O-ring inserts, baseline values could be restored and no significant changes in retention forces were observed at the 10-year follow-up. No difference in anterior and posterior implants could be determined.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Initial retention forces of mandibular IODs supported by four MDIs can be reestablished by replacing the O-rings with pristine ones after 10\u00a0years, with stable retention forces at both the male and female parts throughout the functional period, with no discernible differences between anterior and posterior implants.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40729-025-00620-y","type":"journal-article","created":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T07:37:03Z","timestamp":1744875423000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Retention forces in mini-dental-implant retained mandibular overdentures: 10-year outcomes of a non-comparative longitudinal observational study"],"prefix":"10.1186","volume":"11","author":[{"given":"Hristina","family":"Bukvic","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicole","family":"Schenk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Hinz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Schimmel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norbert","family":"Enkling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samir","family":"Abou-Ayash","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,17]]},"reference":[{"issue":"Suppl 1","key":"620_CR1","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1034\/j.1600-0501.2000.011s1108.x","volume":"11","author":"RD Mericske-Stern","year":"2000","unstructured":"Mericske-Stern RD, Taylor TD, Belser U. Management of the edentulous patient. Clin Oral Implants Res. 2000;11(Suppl 1):108\u201325. https:\/\/doi.org\/10.1034\/j.1600-0501.2000.011s1108.x.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"620_CR2","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.jdent.2011.08.017","volume":"40","author":"JM Thomason","year":"2012","unstructured":"Thomason JM, Kelly SAM, Bendkowski A, Ellis JS. Two implant retained overdentures - a review of the literature supporting the McGill and York consensus statements. J Dent. 2012;40(1):22\u201334. https:\/\/doi.org\/10.1016\/j.jdent.2011.08.017.","journal-title":"J Dent"},{"issue":"4","key":"620_CR3","first-page":"390","volume":"16","author":"MA Awad","year":"2003","unstructured":"Awad MA, Lund JP, Shapiro SH, Locker D, Klemetti E, Chehade A, Savard A, Feine JS. Oral health status and treatment satisfaction with mandibular implant overdentures and conventional dentures: a randomized clinical trial in a senior population. Int J Prosthodont. 2003;16(4):390\u20136.","journal-title":"Int J Prosthodont"},{"issue":"3","key":"620_CR4","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1034\/j.1600-0528.2003.00029.x","volume":"31","author":"G Heydecke","year":"2003","unstructured":"Heydecke G, Locker D, Awad MA, Lund JP, Feine JS. Oral and general health-related quality of life with conventional and implant dentures. Community Dent Oral Epidemiol. 2003;31(3):161\u20138. https:\/\/doi.org\/10.1034\/j.1600-0528.2003.00029.x.","journal-title":"Community Dent Oral Epidemiol"},{"issue":"S26","key":"620_CR5","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1111\/clr.14065","volume":"34","author":"S Abou-Ayash","year":"2023","unstructured":"Abou-Ayash S, Fonseca M, Pieralli S, Reissmann DR. Treatment effect of implant-supported fixed complete dentures and implant overdentures on patient-reported outcomes: a systematic review and meta-analysis. Clin Oral Implants Res. 2023;34(S26):177\u201395. https:\/\/doi.org\/10.1111\/clr.14065.","journal-title":"Clin Oral Implants Res"},{"issue":"Suppl 26","key":"620_CR6","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1111\/clr.14145","volume":"34","author":"M Schimmel","year":"2023","unstructured":"Schimmel M, Arauj M, Abou-Ayash S, Buser R, Ebenezer S, Fonseca M, Heitz-Mayfield LJ, Holtzman LP, Kamnoedboon P, Levine R, McKenna G, Maniewicz S, Matarazzo F, Mattheos N, Papaspyridakos P, De Souza AB, Srinivasan M, Stilwell C, Weber HP. Group 4 ITI consensus report: patient benefits following implant treatment in partially and fully edentulous patients. Clin Oral Implants Res. 2023;34(Suppl 26):257\u201365. https:\/\/doi.org\/10.1111\/clr.14145.","journal-title":"Clin Oral Implants Res"},{"issue":"6","key":"620_CR7","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1111\/cid.12386","volume":"18","author":"A Visser","year":"2016","unstructured":"Visser A, Stellingsma C, Raghoebar GM, Meijer HJA, Vissink A. A 15-year comparative prospective study of surgical and prosthetic care and aftercare of overdenture treatment in the atrophied mandible: augmentation versus nonaugmentation. Clin Implant Dent Relat Res. 2016;18(6):1218\u201326. https:\/\/doi.org\/10.1111\/cid.12386.","journal-title":"Clin Implant Dent Relat Res"},{"key":"620_CR8","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1111\/clr.13342","volume":"29","author":"RE Jung","year":"2018","unstructured":"Jung RE, et al. Group 1 ITI consensus report: the influence of implant length and design and medications on clinical and patient-reported outcomes. Clin Oral Implants Res. 2018;29:69\u201377. https:\/\/doi.org\/10.1111\/clr.13342.","journal-title":"Clin Oral Implants Res"},{"key":"620_CR9","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1111\/clr.13272","volume":"29","author":"E Schiegnitz","year":"2018","unstructured":"Schiegnitz E, Al-Nawas B. Narrow-diameter implants: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29:21\u201340. https:\/\/doi.org\/10.1111\/clr.13272.","journal-title":"Clin Oral Implants Res"},{"issue":"6","key":"620_CR10","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1111\/clr.13591","volume":"31","author":"N Enkling","year":"2020","unstructured":"Enkling N, Moazzin R, Geers G, Kokoschka S, Abou-Ayash S, Schimmel M. Clinical outcomes and bone-level alterations around one-piece mini dental implants retaining mandibular overdentures: 5-year follow-up of a prospective cohort study. Clin Oral Implants Res. 2020;31(6):549\u201356. https:\/\/doi.org\/10.1111\/clr.13591.","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"620_CR11","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1111\/cid.12816","volume":"21","author":"S Abou-Ayash","year":"2019","unstructured":"Abou-Ayash S, Enkling N, Srinivasan M, Haueter M, Worni A, Schimmel M. Evolution of in vivo assessed retention forces in one-piece mini dental implant-retained mandibular overdentures: 5-year follow-up of a prospective clinical trial. Clin Implant Dent Relat Res. 2019;21(5):968\u201376. https:\/\/doi.org\/10.1111\/cid.12816.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"2","key":"620_CR12","first-page":"219","volume":"7","author":"B Al-Nawas","year":"2014","unstructured":"Al-Nawas B, Schiegnitz E. Augmentation procedures using bone substitute materials or autogenous bone - a systematic review and meta-analysis. Eur J Oral Implantol. 2014;7(2):219\u201334.","journal-title":"Eur J Oral Implantol"},{"key":"620_CR13","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.jdent.2016.11.009","volume":"57","author":"CAA Lemos","year":"2017","unstructured":"Lemos CAA, Verri FR, Batista VEdS, J\u00fanior JFS, Mello CC, Pellizzer EP. Complete overdentures retained by mini implants: a systematic review. J Dent. 2017;57:4\u201313. https:\/\/doi.org\/10.1016\/j.jdent.2016.11.009.","journal-title":"J Dent"},{"issue":"8","key":"620_CR14","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1111\/joor.12287","volume":"42","author":"AB Ribeiro","year":"2015","unstructured":"Ribeiro AB, Della Vecchia MP, Cunha TR, Sorgini DB, Dos Reis AC, Muglia VA, de Albuquerque Jr RF, de Souza RF. Short-term post-operative pain and discomfort following insertion of mini-implants for retaining mandibular overdentures: a randomized controlled trial. J Oral Rehabil. 2015;42(8):605\u201314. https:\/\/doi.org\/10.1111\/joor.12287.","journal-title":"J Oral Rehabil"},{"issue":"3","key":"620_CR15","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.prosdent.2017.12.012","volume":"120","author":"MX Pisani","year":"2018","unstructured":"Pisani MX, Presotto AGC, Mesquita MF, Bar\u00e3o VAR, Kemmoku DT, Del Bel Cury AA. Biomechanical behavior of 2-implant\u2013 and single-implant\u2013retained mandibular overdentures with conventional or mini implants. J Prosthet Dent. 2018;120(3):421\u201330. https:\/\/doi.org\/10.1016\/j.prosdent.2017.12.012.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"620_CR16","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/S0022-3913(11)60099-1","volume":"106","author":"IC Chen","year":"2011","unstructured":"Chen IC, Brudvik JS, Mancl LA, Rubenstein JE, Chitswe K, Raigrodski AJ. Freedom of rotation of selected overdenture attachments: an in vitro study. J Prosthet Dent. 2011;106(2):78\u201386. https:\/\/doi.org\/10.1016\/S0022-3913(11)60099-1.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"620_CR17","doi-asserted-by":"publisher","first-page":"845","DOI":"10.4012\/dmj.2011-057","volume":"30","author":"V Rutkunas","year":"2011","unstructured":"Rutkunas V, Mizutani H, Takahashi H, Iwasaki N. Wear simulation effects on overdenture stud attachments. Dent Mater J. 2011;30(6):845\u201353. https:\/\/doi.org\/10.4012\/dmj.2011-057.","journal-title":"Dent Mater J"},{"issue":"2","key":"620_CR18","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1563\/1548-1336(2002)028","volume":"28","author":"S Winkler","year":"2002","unstructured":"Winkler S, Piermatti J, Rothman A, Siamos G. An overview of the O-ring implant overdenture attachment: clinical reports. J Oral Implantol. 2002;28(2):82\u20136. https:\/\/doi.org\/10.1563\/1548-1336(2002)028.","journal-title":"J Oral Implantol"},{"issue":"1","key":"620_CR19","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.prosdent.2004.10.013","volume":"93","author":"MI MacEntee","year":"2005","unstructured":"MacEntee MI, Walton JN, Glick N. A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: three-year results. J Prosthet Dent. 2005;93(1):28\u201337. https:\/\/doi.org\/10.1016\/j.prosdent.2004.10.013.","journal-title":"J Prosthet Dent"},{"key":"620_CR20","doi-asserted-by":"publisher","first-page":"e081","DOI":"10.1590\/1807-3107bor-2022","volume":"36","author":"AJ Schuster","year":"2022","unstructured":"Schuster AJ, Marcello-Machado RM, Bielemann AM, Possebon APdR, Del Bel Cury AA, Faot F. Prosthetic complications and quality of life among wearers of mandibular overdenture with the Facility-Equator system. Braz Oral Res. 2022;36:e081. https:\/\/doi.org\/10.1590\/1807-3107bor-2022.","journal-title":"Braz Oral Res"},{"issue":"6","key":"620_CR21","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1111\/jopr.12534","volume":"27","author":"MA Elsyad","year":"2018","unstructured":"Elsyad MA, Elhaddad AA, Khirallah AS. Retentive properties of O-ring and locator attachments for implant-retained maxillary overdentures: an in vitro study. J Prosthodont. 2018;27(6):568\u201376. https:\/\/doi.org\/10.1111\/jopr.12534.","journal-title":"J Prosthodont"},{"issue":"4","key":"620_CR22","doi-asserted-by":"publisher","first-page":"357","DOI":"10.11607\/ijp.4677","volume":"29","author":"C Chaves","year":"2016","unstructured":"Chaves C, Souza RF, Cunha TR, Vecchia MP, Ribeiro AB, Bruniera JF, Silva-Sousa YT. Preliminary in vitro study on O-ring wear in mini-implant\u2013retained overdentures. Int J Prosthodont. 2016;29(4):357\u20139. https:\/\/doi.org\/10.11607\/ijp.4677.","journal-title":"Int J Prosthodont"},{"issue":"1","key":"620_CR23","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.prosdent.2018.04.010","volume":"121","author":"MLC Valente","year":"2019","unstructured":"Valente MLC, Shimano MVW, Agnelli JAM, dos Reis AC. Retention force and deformation of an innovative attachment model for mini-implant\u2013retained overdentures. J Prosthet Dent. 2019;121(1):129\u201334. https:\/\/doi.org\/10.1016\/j.prosdent.2018.04.010.","journal-title":"J Prosthet Dent"},{"key":"620_CR24","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.7055","author":"S Abou-Ayash","year":"2023","unstructured":"Abou-Ayash S, Schimmel M, Worni A, Enkling N. O-ring attachments on one-piece mini dental implants: in-vitro analysis of retention force reproducibility using different pristine matrix-O-ring combinations. Int J Prosthodont. 2023. https:\/\/doi.org\/10.11607\/ijp.7055.","journal-title":"Int J Prosthodont"},{"issue":"4","key":"620_CR25","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1111\/clr.12822","volume":"28","author":"N Enkling","year":"2017","unstructured":"Enkling N, Saftig M, Worni A, Mericske-Stern R, Schimmel M. Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants - a prospective clinical study: results after one year. Clin Oral Implants Res. 2017;28(4):476\u201382. https:\/\/doi.org\/10.1111\/clr.12822.","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"620_CR26","doi-asserted-by":"publisher","first-page":"99","DOI":"10.3390\/jfb15040099","volume":"15","author":"N Schenk","year":"2024","unstructured":"Schenk N, Bukvic H, Schimmel M, Abou-Ayash S, Enkling N. One-piece mini dental implant-retained mandibular overdentures: 10-year clinical and radiological outcomes of a non-comparative longitudinal observational study. J Funct Biomater. 2024;15(4):99. https:\/\/doi.org\/10.3390\/jfb15040099.","journal-title":"J Funct Biomater"},{"key":"620_CR27","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1111\/j.1600-0501.2011.02312.x","volume":"23","author":"S Bayer","year":"2012","unstructured":"Bayer S, Komor N, Kramer A, Albrecht D, Mericske-Stern R, Enkling N. Retention force of plastic clips on implant bars: a randomized controlled trial. Clin Oral Implants Res. 2012;23:1377\u201384.","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"620_CR28","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1016\/s0022-3913(05)80331-2","volume":"73","author":"DR Burns","year":"1995","unstructured":"Burns DR, Unger JW, Elswick RK Jr, Beck DA. Prospective clinical evaluation of mandibular implant overdentures: Part I-Retention, stability, and tissue response. J Prosthet Dent. 1995;73(4):354\u201363. https:\/\/doi.org\/10.1016\/s0022-3913(05)80331-2.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"620_CR29","first-page":"176","volume":"12","author":"VC Petropoulos","year":"1997","unstructured":"Petropoulos VC, Smith W, Kousvelari E. Comparison of retention and release periods for implant overdenture attachments. Int J Oral Maxillofac Implants. 1997;12(2):176\u201385.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"620_CR30","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1046\/j.1365-2842.1999.00369.x","volume":"26","author":"I Naert","year":"1999","unstructured":"Naert I, Gizani S, Vuylsteke M, Van Steenberghe D. A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. J Oral Rehabil. 1999;26(3):195\u2013202. https:\/\/doi.org\/10.1046\/j.1365-2842.1999.00369.x.","journal-title":"J Oral Rehabil"},{"key":"620_CR31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2023.106269","volume":"150","author":"R Wakam","year":"2024","unstructured":"Wakam R, Ramalingam S, Mawussi KB, Gorin C, Benoit A. Retention loss and wear assessment of three attachment systems for implant retained-mandibular overdentures: an in vitro study. J Mech Behav Biomed Mater. 2024;150: 106269. https:\/\/doi.org\/10.1016\/j.jmbbm.2023.106269.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"5","key":"620_CR32","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1111\/cid.12644","volume":"20","author":"A Yabul","year":"2018","unstructured":"Yabul A, Dayan C, Geckili O, Bilhan H, Tuncer N. Evaluation of volumetric wear of abutments on the retention loss of ball attachment systems in implant-retained overdentures: an in vitro study. Clin Implant Dent Relat Res. 2018;20(5):778\u201384. https:\/\/doi.org\/10.1111\/cid.12644.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"4","key":"620_CR33","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1111\/j.1741-2358.2009.00286.x","volume":"26","author":"S Bayer","year":"2009","unstructured":"Bayer S, et al. Comparative study of four retentive anchor systems for implant supported overdentures - retention force changes. Gerodontology. 2009;26(4):268\u201372. https:\/\/doi.org\/10.1111\/j.1741-2358.2009.00286.x.","journal-title":"Gerodontology"},{"issue":"5","key":"620_CR34","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.11607\/jomi.3621","volume":"29","author":"P Turk","year":"2014","unstructured":"Turk P, Geckili O, Turk Y, Gunay V, Bilgin T. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures. Int J Oral Maxillofac Implants. 2014;29(5):1106\u201313. https:\/\/doi.org\/10.11607\/jomi.3621.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"620_CR35","first-page":"31","volume":"24","author":"F Engelhardt","year":"2016","unstructured":"Engelhardt F, Zeman F, Behr M, Hahmel S. Prosthetic complications and maintenance requirements in locator-attached implant-supported overdentures: a retrospective study. Eur J Prosthodont Restor Dent. 2016;24(1):31\u20135.","journal-title":"Eur J Prosthodont Restor Dent"},{"issue":"8","key":"620_CR36","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1111\/j.1532-849X.2010.00613.x","volume":"19","author":"R Branchi","year":"2010","unstructured":"Branchi R, Vangi D, Virga A, Guertin G, Fazi G. Resistance to wear of four matrices with ball attachments for implant overdentures: a fatigue study. J Prosthodont. 2010;19(8):614\u20139. https:\/\/doi.org\/10.1111\/j.1532-849X.2010.00613.x.","journal-title":"J Prosthodont"},{"issue":"6","key":"620_CR37","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.11607\/jomi.3067","volume":"28","author":"MD Scherer","year":"2013","unstructured":"Scherer MD, McGlumphy EA, Seghi RR, Campagni WV. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution. Int J Oral Maxillofac Implants. 2013;28(6):1619\u201328. https:\/\/doi.org\/10.11607\/jomi.3067.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"620_CR38","doi-asserted-by":"publisher","DOI":"10.1155\/2023\/7099761","author":"R Alshenaiber","year":"2023","unstructured":"Alshenaiber R, Barclay C, Silikas N. The effect of mini dental implant number on mandibular overdenture retention and attachment wear. Biomed Res Int. 2023. https:\/\/doi.org\/10.1155\/2023\/7099761.","journal-title":"Biomed Res Int"},{"issue":"6","key":"620_CR39","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.11607\/jomi.5981","volume":"32","author":"K Zygogiannis","year":"2017","unstructured":"Zygogiannis K, Aartman I, Parsa A, Tahmaseb A, Wismeijer D. Implant mandibular overdentures retained by immediately loaded implants: a 1-year randomized trial comparing the clinical and radiographic outcomes between mini dental implants and standard-sized implants. Int J Oral Maxillofac Implants. 2017;32(6):1377\u201388. https:\/\/doi.org\/10.11607\/jomi.5981.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"620_CR40","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1111\/ger.12066","volume":"32","author":"T Mundt","year":"2015","unstructured":"Mundt T, Schwahn C, Stark T, Biffar R. Clinical response of edentulous people treated with mini dental implants in nine dental practices. Gerodontology. 2015;32(3):179\u201387. https:\/\/doi.org\/10.1111\/ger.12066.","journal-title":"Gerodontology"},{"issue":"5","key":"620_CR41","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1111\/jopr.12373","volume":"25","author":"A Catal\u00e1n","year":"2016","unstructured":"Catal\u00e1n A, Mart\u00ednez A, Marchesani F, Gonz\u00e1lez U. Mandibular overdentures retained by two mini-implants: a seven-year retention and satisfaction study. J Prosthodont. 2016;25(5):364\u201370. https:\/\/doi.org\/10.1111\/jopr.12373.","journal-title":"J Prosthodont"},{"issue":"3","key":"620_CR42","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.jpor.2015.12.005","volume":"60","author":"FS Schwindling","year":"2016","unstructured":"Schwindling FS, Schwindling FP. Mini dental implants retaining mandibular overdentures: a dental practice-based retrospective analysis. J Prosthodont Res. 2016;60(3):193\u20138. https:\/\/doi.org\/10.1016\/j.jpor.2015.12.005.","journal-title":"J Prosthodont Res"},{"issue":"12","key":"620_CR43","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1111\/j.1600-0501.2009.01742.x","volume":"20","author":"RCS Rodrigues","year":"2009","unstructured":"Rodrigues RCS, Faria ACL, MacEdo AP, Sartori IADM, De Mattos MDGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment. Clin Oral Implants Res. 2009;20(12):1314\u20139. https:\/\/doi.org\/10.1111\/j.1600-0501.2009.01742.x.","journal-title":"Clin Oral Implants Res"},{"key":"620_CR44","first-page":"215","volume":"20","author":"E Nagaoka","year":"1980","unstructured":"Nagaoka E, Nagayasu Y, Yamashita H, Matsushiro H, Okuno Y. Study of retention in attachments for overdenture. (II) O-ring attachment. J Osaka Univ Dent Sch. 1980;20:215\u201326.","journal-title":"J Osaka Univ Dent Sch"},{"issue":"3","key":"620_CR45","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1111\/cid.12594","volume":"20","author":"FB Raza","year":"2018","unstructured":"Raza FB, Vaidyanathan AK, Veeravalli PT, Ravishankar S, Ali AS. Analysis of crestal bone loss around single piece ball attachment implant placed bilaterally in canine region and wear of O-ring in implant supported overdenture: three year follow-up. Clin Implant Dent Relat Res. 2018;20(3):403\u20139. https:\/\/doi.org\/10.1111\/cid.12594.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"620_CR46","doi-asserted-by":"publisher","first-page":"167","DOI":"10.17219\/dmp\/146719","volume":"60","author":"MR de Campos","year":"2023","unstructured":"de Campos MR, Botelho AL, Dos Reis AC. Reasons for the fatigue of ball attachments and their O-rings: a systematic review. Dent Med Probl. 2023;60(1):167\u201376. https:\/\/doi.org\/10.17219\/dmp\/146719.","journal-title":"Dent Med Probl."},{"issue":"4","key":"620_CR47","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1016\/j.prosdent.2019.03.024","volume":"123","author":"F Gon\u00e7alves","year":"2020","unstructured":"Gon\u00e7alves F, Campestrini VLL, Rigo-Rodrigues MA, Zanardi PR. Effect of the attachment system on the biomechanical and clinical performance of overdentures: a systematic review. J Prosthet Dent. 2020;123(4):589\u201394. https:\/\/doi.org\/10.1016\/j.prosdent.2019.03.024.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"620_CR48","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1016\/j.prosdent.2016.09.027","volume":"117","author":"JW Choi","year":"2017","unstructured":"Choi JW, Bae JH, Jeong CM, Huh JB. Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations. J Prosthet Dent. 2017;117(5):628\u201335. https:\/\/doi.org\/10.1016\/j.prosdent.2016.09.027.","journal-title":"J Prosthet Dent"}],"container-title":["International Journal of Implant Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-025-00620-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40729-025-00620-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-025-00620-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T07:37:06Z","timestamp":1744875426000},"score":1,"resource":{"primary":{"URL":"https:\/\/journalimplantdent.springeropen.com\/articles\/10.1186\/s40729-025-00620-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,17]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["620"],"URL":"https:\/\/doi.org\/10.1186\/s40729-025-00620-y","relation":{},"ISSN":["2198-4034"],"issn-type":[{"value":"2198-4034","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,17]]},"assertion":[{"value":"3 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all subjects involved in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"32"}}