{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T15:18:29Z","timestamp":1767021509737,"version":"3.48.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:00:00Z","timestamp":1766966400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:00:00Z","timestamp":1766966400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"NSK Nakanishi foundation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Implant Dent"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to evaluate the safety of piezoelectric surgery for bone cutting during implant removal in terms of heat generation and histological changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The bone model experiments involved titanium implants or non-metal dummy implants placed in bone models. Bone cutting using a piezoelectric surgery with irrigation was performed at distances of 0, 1, and 2\u00a0mm from the implant, and the temperature was recorded using a contact thermometer placed at the tip of the implant. Using procine mandible models, histological analysis was performed using hematoxylin and eosin-stained images to evaluate the risk of thermal injury.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>When bone cutting was performed at distances of 0\u00a0mm from the implants continuously, a significantly greater temperature increase was observed with the titanium implants compared to the non-metal dummy implants. The increase in temperature decreased as the distance between the implant and the cutting position increased. Comparing the cutting patterns, a greater temperature increase was observed with continuous and 10\u00a0s intermittent cutting. In contrast, it was suppressed with intermittent cutting for 3 and 5\u00a0s. In the histological analysis with porcine mandibles, findings suggest that thermal injury was not observed in any of the samples.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>No bone damage was observed in the histological analysis. In contrast, piezoelectric peri-implant bone cutting caused a significant increase in temperature, especially for continuous bone cutting during implant adjustments. However, intermittent cutting for 3 and 5\u00a0s significantly suppressed the temperature increase. The results suggest that shortening the continuous cutting time may be effective in preventing heat generation when using piezoelectric surgery for peri-implant bone cutting.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40729-025-00658-y","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T15:15:04Z","timestamp":1767021304000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Heat generation and histological analysis of peri-implant bone cutting using piezoelectric surgery for implant removal: an in vitro study"],"prefix":"10.1186","volume":"11","author":[{"given":"Yoshiki","family":"Saito","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Tsukamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiyoshi","family":"Shimada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuke","family":"Kondo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiko","family":"Kiyomura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomotaka","family":"Nodai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Munemasa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taro","family":"Mukaibo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryuji","family":"Hosokawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chihiro","family":"Masaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,29]]},"reference":[{"issue":"3","key":"658_CR1","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/S0022-3913(83)80101-2","volume":"50","author":"PI Br\u00e5nemark","year":"1983","unstructured":"Br\u00e5nemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983;50(3):399\u2013410. https:\/\/doi.org\/10.1016\/S0022-3913(83)80101-2.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"658_CR2","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/S0300-9785(81)80077-4","volume":"10","author":"R Adell","year":"1981","unstructured":"Adell R, Lekholm U, Rockler B, Br\u00e5nemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10(6):387\u2013416. https:\/\/doi.org\/10.1016\/S0300-9785(81)80077-4.","journal-title":"Int J Oral Surg"},{"key":"658_CR3","doi-asserted-by":"publisher","first-page":"S158","DOI":"10.1111\/jcpe.12334","volume":"42","author":"J Derks","year":"2015","unstructured":"Derks J, Tomasi C. Peri-implant health and disease. A systematic review of current epidemiology. J Clin Periodontol. 2015;42:S158\u201371.","journal-title":"J Clin Periodontol"},{"issue":"20","key":"658_CR4","first-page":"S237","volume":"45","author":"LJA Heitz-Mayfield","year":"2018","unstructured":"Heitz-Mayfield LJA, Salvi GE. Peri-implant mucositis. J Clin Periodontol. 2018;45(20):S237-s245.","journal-title":"J Clin Periodontol"},{"key":"658_CR5","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/s00784-019-03127-0","volume":"24","author":"M Roy","year":"2020","unstructured":"Roy M, Loutan L, Garavaglia G, Hashim D. Removal of osseointegrated dental implants: a systematic review of explantation techniques. Clin Oral Investig. 2020;24:47\u201360.","journal-title":"Clin Oral Investig"},{"issue":"3","key":"658_CR6","doi-asserted-by":"publisher","first-page":"e19","DOI":"10.1016\/j.tripleo.2011.06.035","volume":"113","author":"E Anitua","year":"2012","unstructured":"Anitua E, Orive G. A new approach for atraumatic implant explantation and immediate implant installation. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012;113(3):e19-25. https:\/\/doi.org\/10.1016\/j.tripleo.2011.06.035.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"1","key":"658_CR7","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1563\/aaid-joi-D-14-00207","volume":"42","author":"E Anitua","year":"2016","unstructured":"Anitua E, Murias-Freijo A, Alkhraisat MH. Conservative implant removal for the analysis of the cause, removal torque, and surface treatment of failed nonmobile dental implants. J Oral Implantol. 2016;42(1):69\u201377. https:\/\/doi.org\/10.1563\/aaid-joi-D-14-00207.","journal-title":"J Oral Implantol"},{"key":"658_CR8","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.jdsr.2024.01.002","volume":"60","author":"C Masaki","year":"2024","unstructured":"Masaki C, Kondo Y, Tomoeda K, Nodai T, Munemasa T, Mukaibo T, et al. Treatment strategies for dental implant removal: a literature review. Jpn Dent Sci Rev. 2024;60:120\u20137.","journal-title":"Jpn Dent Sci Rev"},{"key":"658_CR9","doi-asserted-by":"publisher","first-page":"17154","DOI":"10.1038\/s41598-018-35295-6","volume":"8","author":"Y Otake","year":"2018","unstructured":"Otake Y, Nakamura M, Henmi A, Takahashi T, Sasano Y. Experimental comparison of the performance of cutting bone and soft tissue between piezosurgery and conventional rotary instruments. Sci Rep. 2018;8:17154.","journal-title":"Sci Rep"},{"issue":"4","key":"658_CR10","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.jormas.2017.06.009","volume":"118","author":"J Gonzalez-Lagunas","year":"2017","unstructured":"Gonzalez-Lagunas J. Is the piezoelectric device the new standard for facial osteotomies? J Stomatol Oral Maxillofac Surg. 2017;118(4):255\u20138. https:\/\/doi.org\/10.1016\/j.jormas.2017.06.009.","journal-title":"J Stomatol Oral Maxillofac Surg"},{"key":"658_CR11","doi-asserted-by":"publisher","first-page":"105483","DOI":"10.1155\/2012\/105483","volume":"2012","author":"C Riben","year":"2012","unstructured":"Riben C, Thor A. The maxillary sinus membrane elevation procedure: augmentation of bone around dental implants without grafts-a review of a surgical technique. Int J Dent. 2012;2012:105483. https:\/\/doi.org\/10.1155\/2012\/105483.","journal-title":"Int J Dent"},{"key":"658_CR12","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.ijom.2010.11.013","volume":"40","author":"G Pavl\u00edkov\u00e1","year":"2011","unstructured":"Pavl\u00edkov\u00e1 G, Folt\u00e1n R, Hork\u00e1 M, Hanzelka T, Borunsk\u00e1 H, Sed\u00fd J. Piezosurgery in oral and maxillofacial surgery. Int J Oral Maxillofac Surg. 2011;40:451\u20137.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"18","key":"658_CR13","doi-asserted-by":"publisher","first-page":"4072","DOI":"10.3390\/ma13184072","volume":"13","author":"L Lamazza","year":"2020","unstructured":"Lamazza L, Lollobrigida M, Vozza I, Palmieri L, Stacchi C, Lombardi T, et al. Piezoelectric implant site preparation: influence of handpiece movements on temperature elevation. Materials. 2020;13(18):4072.","journal-title":"Materials"},{"key":"658_CR14","first-page":"e71396","volume":"16","author":"N Jain","year":"2024","unstructured":"Jain N, Dhawan P, Rani S, Kalra J. Heat generation and pain assessment in piezosurgery versus conventional drilling for implant placement: a systematic review. Cureus. 2024;16:e71396.","journal-title":"Cureus"},{"issue":"2","key":"658_CR15","doi-asserted-by":"publisher","first-page":"e140","DOI":"10.1111\/clr.12077","volume":"25","author":"F Stelzle","year":"2014","unstructured":"Stelzle F, Frenkel C, Riemann M, Knipfer C, Stockmann P, Nkenke E. The effect of load on heat production, thermal effects and expenditure of time during implant site preparation - an experimental ex vivo comparison between piezosurgery and conventional drilling. Clin Oral Implants Res. 2014;25(2):e140\u20138. https:\/\/doi.org\/10.1111\/clr.12077.","journal-title":"Clin Oral Implants Res"},{"key":"658_CR16","doi-asserted-by":"publisher","first-page":"345","DOI":"10.11607\/jomi.5806","volume":"33","author":"JK Fugito","year":"2018","unstructured":"Fugito JK, Cortes AR, de Carvalho Destro R, Yoshimoto M. Comparative study on the cutting effectiveness and heat generation of rotary instruments versus piezoelectric surgery tips using scanning electron microscopy and thermal analysis. Int J Oral Maxillofac Implants. 2018;33:345\u201350.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"658_CR17","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1002\/JPER.17-0502","volume":"89","author":"C Lajolo","year":"2018","unstructured":"Lajolo C, Valente NA, Romandini WG, Petruzzi M, Verdugo F, D\u2019Addona A. Bone heat generated using conventional implant drills versus piezosurgery unit during apical cortical plate perforation. J Periodontol. 2018;89(6):661\u20138. https:\/\/doi.org\/10.1002\/JPER.17-0502.","journal-title":"J Periodontol"},{"key":"658_CR18","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1007\/s10266-022-00730-8","volume":"111","author":"N Bhargava","year":"2023","unstructured":"Bhargava N, Perrotti V, Caponio VCA, Matsubara VH, Patalwala D, Quaranta A. Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: an ex vivo study on porcine ribs. Odontology. 2023;111:142\u201353.","journal-title":"Odontology"},{"key":"658_CR19","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1007\/s12663-022-01800-8","volume":"22","author":"L Aquilanti","year":"2023","unstructured":"Aquilanti L, Antognoli L, Rappelli G, Di Felice R, Scalise L. Heat generation during initial osteotomy for implant site preparation: an in vitro measurement study. J Maxillofac Oral Surg. 2023;22:313\u201320.","journal-title":"J Maxillofac Oral Surg"},{"key":"658_CR20","first-page":"115","volume":"5","author":"L Lamazza","year":"2014","unstructured":"Lamazza L, Laurito D, Lollobrigida M, Brugnoletti O, Garreffa G, De Biase A. Identification of possible factors influencing temperatures elevation during implant site preparation with piezoelectric technique. Ann Stomatol (Roma). 2014;5:115\u201322.","journal-title":"Ann Stomatol (Roma)"},{"key":"658_CR21","first-page":"22","volume":"42","author":"JC Woods","year":"2022","unstructured":"Woods JC, Cook JL, Bozynski CC, Tegethoff JD, Kuroki K, Crist BD. Does irrigating while drilling decrease bone damage? Iowa Orthop J. 2022;42:22\u20139.","journal-title":"Iowa Orthop J"},{"issue":"6","key":"658_CR22","doi-asserted-by":"publisher","first-page":"634","DOI":"10.4103\/JCDE.JCDE_130_24","volume":"27","author":"AK Jain","year":"2024","unstructured":"Jain AK, Jain R, Rao R, Rao P, Yadav P, Thorat V. Comparative evaluation of increase in temperature on the external root surface of teeth during retrieval of broken NiTi instrument using two ultrasonic tips and two power settings: an in vitro study. J Conservat Dent Endod. 2024;27(6):634\u20138. https:\/\/doi.org\/10.4103\/JCDE.JCDE_130_24.","journal-title":"J Conservat Dent Endod"},{"key":"658_CR23","doi-asserted-by":"publisher","first-page":"8","DOI":"10.3389\/fvets.2015.00008","volume":"2","author":"P Hennet","year":"2015","unstructured":"Hennet P. Piezoelectric bone surgery: a review of the literature and potential applications in veterinary oromaxillofacial surgery. Front Vet Sci. 2015;2:8.","journal-title":"Front Vet Sci"},{"issue":"1","key":"658_CR24","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/0022-3913(83)90174-9","volume":"50","author":"AR Eriksson","year":"1983","unstructured":"Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50(1):101\u20137. https:\/\/doi.org\/10.1016\/0022-3913(83)90174-9.","journal-title":"J Prosthet Dent"},{"issue":"16","key":"658_CR25","doi-asserted-by":"publisher","first-page":"3461","DOI":"10.3390\/ma13163461","volume":"13","author":"K Kniha","year":"2020","unstructured":"Kniha K, Heussen N, Weber E, M\u00f6hlhenrich SC, H\u00f6lzle F, Modabber A. Temperature threshold values of bone necrosis for thermo-explantation of dental implants\u2014a systematic review on preclinical in vivo research. Materials. 2020;13(16):3461.","journal-title":"Materials"},{"key":"658_CR26","doi-asserted-by":"publisher","first-page":"9654975","DOI":"10.1155\/2016\/9654975","volume":"2016","author":"J Matys","year":"2016","unstructured":"Matys J, Flieger R, Dominiak M. Assessment of temperature rise and time of alveolar ridge splitting by means of Er:YAG laser, piezosurgery, and surgical saw: an ex vivo study. BioMed Res Int. 2016;2016:9654975. https:\/\/doi.org\/10.1155\/2016\/9654975.","journal-title":"BioMed Res Int"},{"issue":"10","key":"658_CR27","doi-asserted-by":"publisher","first-page":"e301","DOI":"10.1016\/j.bjoms.2020.08.013","volume":"58","author":"HAM Marzook","year":"2020","unstructured":"Marzook HAM, Yousef EA, Denewar M, Farahat MRL. In-vitro assessment of bone viability with different implant drill speeds. Br J Oral Maxillofac Surg. 2020;58(10):e301\u20136. https:\/\/doi.org\/10.1016\/j.bjoms.2020.08.013.","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"4","key":"658_CR28","first-page":"e1517","volume":"6","author":"A Galloway","year":"2024","unstructured":"Galloway A, Pope E, Juarez C. Bone color changes and interpretation of the temperature\/duration of fire exposure to human remains in the forensic context. Wiley Interdiscip Rev: Forensic Sci. 2024;6(4):e1517.","journal-title":"Wiley Interdiscip Rev: Forensic Sci"},{"key":"658_CR29","doi-asserted-by":"publisher","first-page":"109215","DOI":"10.1016\/j.matdes.2020.109215","volume":"197","author":"JA Robles-Linares","year":"2021","unstructured":"Robles-Linares JA, Axinte D, Liao Z, Gameros A. Machining-induced thermal damage in cortical bone: Necrosis and micro-mechanical integrity. Mater Des. 2021;197:109215.","journal-title":"Mater Des"}],"container-title":["International Journal of Implant Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-025-00658-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40729-025-00658-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-025-00658-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T15:15:05Z","timestamp":1767021305000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40729-025-00658-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,29]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["658"],"URL":"https:\/\/doi.org\/10.1186\/s40729-025-00658-y","relation":{},"ISSN":["2198-4034"],"issn-type":[{"value":"2198-4034","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,29]]},"assertion":[{"value":"11 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not Applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"This study was supported by the NSK Nakanishi foundation.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"73"}}