{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:47:24Z","timestamp":1792788444962,"version":"4.5.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T00:00:00Z","timestamp":1791849600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T00:00:00Z","timestamp":1792368000000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University of Bern","id":[{"id":"https:\/\/ror.org\/02k7v4d05","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Implant Dent"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the internal fit at the implant-abutment interface of zirconia and cobalt\u2013chromium abutments fabricated using different techniques by micro-computed tomography (micro-CT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Twenty screw-retained abutments were divided into 4 groups (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20095): milled zirconia (ZrCAD), milled cobalt\u2013chromium (Co-CrMill), laser-sintered cobalt\u2013chromium (Co-CrLS), and cast cobalt\u2013chromium (Co-CrCL). Specimens were subjected to cyclic loading (300,000 cycles, 200\u00a0N) and thermocycling (10000 cycles, 5 to 50\u00a0\u00b0C). Internal fit was assessed by micro-CT at 3 regions and 3 spatial planes (180 measurements). Data were analyzed with Kruskal\u2013Wallis and Bonferroni-Holm tests (\u03b1\u2009=\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Significant differences in internal fit were found (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). Co-CrLS showed the highest internal gap values (26.75\u2009\u00b1\u20097.05\u00a0\u03bcm, 87.00\u2009\u00b1\u20093.26\u00a0\u03bcm, 86.50\u2009\u00b1\u20095.76\u00a0\u03bcm). Significant differences were observed between Co-CrLS and ZrCAD (Region 1,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.003), Co-CrMill (Regions 1 and 2,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.003\u20130.004), and Co-CrCL (Regions 1 and 3,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.003\u20130.001). Total values also differed between Co-CrMill and Co-CrLS (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.012) and Co-CrCL and Co-CrLS (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.002).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Internal fit differed among the evaluated workflows. Laser-sintered cobalt\u2013chromium abutments showed the least favorable adaptation, whereas milled and cast cobalt\u2013chromium showed lower gap values; zirconia showed intermediate descriptive values. The clinical significance of these differences remains uncertain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical trial number<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40729-026-00718-x","type":"journal-article","created":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:45:53Z","timestamp":1791927953000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Internal fit of cobalt\u2013chromium and zirconia implant abutments fabricated using different techniques: a micro\u2013computed tomography study"],"prefix":"10.1186","volume":"12","author":[{"given":"Pedro","family":"Molinero-Mourelle","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seyed Ali","family":"Mosaddad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rocio","family":"Cascos-Sanchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Margarita Chevalier","family":"del R\u00edo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fclce","family":"\u00c7akmak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Roccuzzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel","family":"G\u00f3mez-Polo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,13]]},"reference":[{"key":"718_CR1","doi-asserted-by":"publisher","first-page":"551","DOI":"10.11607\/ijp.4892","volume":"29","author":"T Jemt","year":"2016","unstructured":"Jemt T. Single-Implant Survival: More Than 30 Years of Clinical Experience. Int J Prosthodont. 2016;29:551\u20138.","journal-title":"Int J Prosthodont"},{"issue":"Suppl 1","key":"718_CR2","first-page":"S155","volume":"9","author":"L Hjalmarsson","year":"2016","unstructured":"Hjalmarsson L, Gheisarifar M, Jemt T. A systematic review of survival of single implants as presented in longitudinal studies with a follow-up of at least 10 years. Eur J Oral Implantol. 2016;9(Suppl 1):S155\u201362.","journal-title":"Eur J Oral Implantol"},{"issue":"Suppl 6","key":"718_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1111\/j.1600-0501.2012.02547.x","volume":"23","author":"RE Jung","year":"2012","unstructured":"Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res. 2012;23(Suppl 6):2\u201321.","journal-title":"Clin Oral Implants Res"},{"key":"718_CR4","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1007\/s00784-024-06093-4","volume":"29","author":"P Diaz","year":"2025","unstructured":"Diaz P, Vizoso B, Lopez-Suarez C, Gonzalo E, Mosaddad SA, Suarez MJ. Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments. Clin Oral Investig. 2025;29:72.","journal-title":"Clin Oral Investig"},{"key":"718_CR5","doi-asserted-by":"publisher","first-page":"e70318","DOI":"10.1002\/cre2.70318","volume":"12","author":"P Diaz","year":"2026","unstructured":"Diaz P, Miegimolle B, Martin A, Mosaddad SA, Tobar C, Suarez MJ. Marginal Misfit Assessment in Common Restorative Materials for Cement-Retained Fixed Implant Prostheses: An In Vitro Comparative Study. Clin Exp Dent Res. 2026;12:e70318.","journal-title":"Clin Exp Dent Res"},{"issue":"Suppl 16","key":"718_CR6","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1111\/clr.13306","volume":"29","author":"BE Pjetursson","year":"2018","unstructured":"Pjetursson BE, Valente NA, Strasding M, Zwahlen M, Liu S, Sailer I. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns. Clin Oral Implants Res. 2018;29(Suppl 16):199\u2013214.","journal-title":"Clin Oral Implants Res"},{"issue":"Suppl 1","key":"718_CR7","first-page":"121","volume":"10","author":"J Katsoulis","year":"2017","unstructured":"Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature. Eur J Oral Implantol. 2017;10(Suppl 1):121\u201338.","journal-title":"Eur J Oral Implantol"},{"key":"718_CR8","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1111\/cid.12968","volume":"23","author":"Y Pan","year":"2021","unstructured":"Pan Y, Tsoi JKH, Lam WYH, Pow EHN. Implant framework misfit: A systematic review on assessment methods and clinical complications. Clin Implant Dent Relat Res. 2021;23:244\u201358.","journal-title":"Clin Implant Dent Relat Res"},{"key":"718_CR9","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1111\/cid.12792","volume":"21","author":"Y He","year":"2019","unstructured":"He Y, Fok A, Aparicio C, Teng W. Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study. Clin Implant Dent Relat Res. 2019;21:741\u201352.","journal-title":"Clin Implant Dent Relat Res"},{"key":"718_CR10","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1186\/s40729-023-00494-y","volume":"9","author":"Z Mao","year":"2023","unstructured":"Mao Z, Beuer F, Wu D, Zhu Q, Yassine J, Schwitalla A, et al. Microleakage along the implant-abutment interface: a systematic review and meta-analysis of in vitro studies. Int J Implant Dent. 2023;9:34.","journal-title":"Int J Implant Dent"},{"key":"718_CR11","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1002\/jbm.a.34709","volume":"102","author":"CM Schmitt","year":"2014","unstructured":"Schmitt CM, Nogueira-Filho G, Tenenbaum HC, Lai JY, Brito C, D\u00f6ring H, et al. Performance of conical abutment (Morse Taper) connection implants: a systematic review. J Biomed Mater Res A. 2014;102:552\u201374.","journal-title":"J Biomed Mater Res A"},{"key":"718_CR12","doi-asserted-by":"publisher","first-page":"182","DOI":"10.11607\/ijp.5616","volume":"32","author":"CC Mello","year":"2019","unstructured":"Mello CC, Lemos CAA, de Luna Gomes JM, Verri FR, Pellizzer EP. CAD\/CAM vs Conventional Technique for Fabrication of Implant-Supported Frameworks: A Systematic Review and Meta-analysis of In Vitro Studies. Int J Prosthodont. 2019;32:182\u201392.","journal-title":"Int J Prosthodont"},{"key":"718_CR13","doi-asserted-by":"publisher","first-page":"1062","DOI":"10.1111\/cid.12839","volume":"21","author":"A Uribarri","year":"2019","unstructured":"Uribarri A, Bilbao-Uriarte E, Segurola A, Ugarte D, Verdugo F. Marginal and internal fit of CAD\/CAM frameworks in multiple implant-supported restorations: Scanning and milling error analysis. Clin Implant Dent Relat Res. 2019;21:1062\u201372.","journal-title":"Clin Implant Dent Relat Res"},{"key":"718_CR14","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1016\/j.prosdent.2018.08.005","volume":"121","author":"A Naveau","year":"2019","unstructured":"Naveau A, Rignon-Bret C, Wulfman C. Zirconia abutments in the anterior region: A systematic review of mechanical and esthetic outcomes. J Prosthet Dent. 2019;121:775\u2013e811.","journal-title":"J Prosthet Dent"},{"key":"718_CR15","doi-asserted-by":"crossref","unstructured":"Molinero-Mourelle P, Cascos-Sanchez R, Yilmaz B, Lam WYH, Pow EHN, Del R\u00edo Highsmith J, et al. Effect of fabrication technique on the microgap of CAD\/CAM cobalt-chrome and zirconia abutments on a conical connection implant: an in vitro study. Materials (Basel). 2021;14.","DOI":"10.3390\/ma14092348"},{"issue":"Suppl 1","key":"718_CR16","first-page":"47","volume":"10","author":"S Abou-Ayash","year":"2017","unstructured":"Abou-Ayash S, Strasding M, R\u00fccker G, Att W. Impact of prosthetic material on mid- and long-term outcome of dental implants supporting single crowns and fixed partial dentures: A systematic review and meta-analysis. Eur J Oral Implantol. 2017;10(Suppl 1):47\u201365.","journal-title":"Eur J Oral Implantol"},{"issue":"Suppl 11","key":"718_CR17","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1111\/clr.12631","volume":"26","author":"T Linkevicius","year":"2015","unstructured":"Linkevicius T, Vaitelis J. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis. Clin Oral Implants Res. 2015;26(Suppl 11):139\u201347.","journal-title":"Clin Oral Implants Res"},{"key":"718_CR18","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1080\/23337931.2017.1360776","volume":"3","author":"M Kassapidou","year":"2017","unstructured":"Kassapidou M, Franke Stenport V, Hjalmarsson L, Johansson CB. Cobalt-chromium alloys in fixed prosthodontics in Sweden. Acta Biomater Odontol Scand. 2017;3:53\u201362.","journal-title":"Acta Biomater Odontol Scand"},{"key":"718_CR19","doi-asserted-by":"publisher","first-page":"343","DOI":"10.11607\/ijp.3024","volume":"26","author":"P Svanborg","year":"2013","unstructured":"Svanborg P, L\u00e4ngstr\u00f6m L, Lundh RM, Bjerkstig G, Ortorp A. A 5-year retrospective study of cobalt-chromium-based fixed dental prostheses. Int J Prosthodont. 2013;26:343\u20139.","journal-title":"Int J Prosthodont"},{"key":"718_CR20","doi-asserted-by":"publisher","first-page":"6097","DOI":"10.1007\/s00784-022-04559-x","volume":"26","author":"S Nilsson","year":"2022","unstructured":"Nilsson S, Stenport VF, Nilsson M, G\u00f6thberg C. A retrospective clinical study of fixed tooth- and implant-supported prostheses in titanium and cobalt-chromium-ceramic: 5-9-year follow-up. Clin Oral Investig. 2022;26:6097\u2013103.","journal-title":"Clin Oral Investig"},{"key":"718_CR21","doi-asserted-by":"publisher","first-page":"138","DOI":"10.4047\/jap.2014.6.2.138","volume":"6","author":"YS Al Jabbari","year":"2014","unstructured":"Al Jabbari YS. Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature. J Adv Prosthodont. 2014;6:138\u201345.","journal-title":"J Adv Prosthodont"},{"key":"718_CR22","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s40496-017-0152-0","volume":"4","author":"M Revilla-Le\u00f3n","year":"2017","unstructured":"Revilla-Le\u00f3n M, \u00d6zcan M. Additive Manufacturing Technologies Used for 3D Metal Printing in Dentistry. Curr Oral Health Rep. 2017;4:201\u20138.","journal-title":"Curr Oral Health Rep"},{"key":"718_CR23","doi-asserted-by":"crossref","unstructured":"Gonzalo E, Vizoso B, Lopez-Suarez C, Diaz P, Pelaez J, Suarez MJ. Evaluation of milled titanium versus laser sintered Co-Cr abutments on the marginal misfit in internal implant-abutment connection. Materials (Basel). 2020;13.","DOI":"10.3390\/ma13214873"},{"key":"718_CR24","doi-asserted-by":"publisher","first-page":"946","DOI":"10.1186\/s12903-023-03700-w","volume":"23","author":"HI Nassar","year":"2023","unstructured":"Nassar HI, Fateen A. Accuracy of fit for cobaltchromium bar over two implants fabricated with different manufacturing techniques: an in-vitro study. BMC Oral Health. 2023;23:946.","journal-title":"BMC Oral Health"},{"key":"718_CR25","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1111\/clr.13973","volume":"33","author":"P Molinero-Mourelle","year":"2022","unstructured":"Molinero-Mourelle P, Roccuzzo A, Yilmaz B, Lam WYH, Pow EHN, Highsmith JDR, et al. Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study. Clin Oral Implants Res. 2022;33:945\u201352.","journal-title":"Clin Oral Implants Res"},{"key":"718_CR26","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1097\/ID.0000000000000465","volume":"25","author":"A Scarano","year":"2016","unstructured":"Scarano A, Valbonetti L, Degidi M, Pecci R, Piattelli A, de Oliveira PS, et al. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography. Implant Dent. 2016;25:656\u201362.","journal-title":"Implant Dent"},{"key":"718_CR27","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1111\/jopr.13326","volume":"30","author":"E O\u011fuz","year":"2021","unstructured":"O\u011fuz E, K\u0131l\u0131\u00e7arslan MA, \u00d6zcan M, Ocak M, Bileceno\u011flu B, Orhan K. Evaluation of Denture Base Adaptation Fabricated Using Conventional, Subtractive, and Additive Technologies: A Volumetric Micro-Computed Tomography Analysis. J Prosthodont. 2021;30:257\u201363.","journal-title":"J Prosthodont"},{"key":"718_CR28","doi-asserted-by":"publisher","first-page":"1414","DOI":"10.1186\/s12903-025-06837-y","volume":"25","author":"A Ziada","year":"2025","unstructured":"Ziada A, Beleidy M. Micro-CT evaluation of internal fit of two different implant-abutment connections with different customized abutment materials. BMC Oral Health. 2025;25:1414.","journal-title":"BMC Oral Health"},{"key":"718_CR29","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1111\/jopr.13656","volume":"32","author":"M Elsherbini","year":"2023","unstructured":"Elsherbini M, Sakrana AA, Amin RA, Diaa M, \u00d6zcan M, Al-Zordk W. A micro-computed tomography analysis of internal and marginal fits of fixed partial dentures: Effect of preparation finish line designs on monolithic zirconia and heat-pressed zirconia-reinforced lithium disilicate. J Prosthodont. 2023;32:90\u20139.","journal-title":"J Prosthodont"},{"key":"718_CR30","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/j.prosdent.2016.08.002","volume":"117","author":"EH Kim","year":"2017","unstructured":"Kim EH, Lee DH, Kwon SM, Kwon TY. A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems. J Prosthet Dent. 2017;117:393\u20139.","journal-title":"J Prosthet Dent"},{"key":"718_CR31","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1146\/annurev-bioeng-062117-121139","volume":"20","author":"EF Morgan","year":"2018","unstructured":"Morgan EF, Unnikrisnan GU, Hussein AI. Bone Mechanical Properties in Healthy and Diseased States. Annu Rev Biomed Eng. 2018;20:119\u201343.","journal-title":"Annu Rev Biomed Eng"},{"key":"718_CR32","unstructured":"International Organization for S. Dentistry\u2014Implants for Surgery\u2014Ceramic Materials Based on Yttria-Stabilized Tetragonal Zirconia (Y-TZP). ISO 13356:2015. 2015."},{"key":"718_CR33","unstructured":"International Organization for S. Dentistry\u2014Implants for Surgery\u2014Metallic Materials\u2014Part 12: Wrought Cobalt-Chromium-Molybdenum Alloy. ISO 5832-12:2019. 2019."},{"key":"718_CR34","unstructured":"International Organization for S. Dentistry\u2014Implants\u2014Dynamic Loading Test for Endosseous Dental Implants. ISO 14801:2016. 2016."},{"key":"718_CR35","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.nima.2007.05.073","volume":"580","author":"J Vlassenbroeck","year":"2007","unstructured":"Vlassenbroeck J, Dierick M, Masschaele B, Cnudde V, Van Hoorebeke L, Jacobs P. Software tools for quantification of X-ray microtomography at the UGCT. Nucl Instrum Methods Phys Res Sect A. 2007;580:442\u20135.","journal-title":"Nucl Instrum Methods Phys Res Sect A"},{"key":"718_CR36","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1364\/JOSAA.1.000612","volume":"1","author":"LA Feldkamp","year":"1984","unstructured":"Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am A. 1984;1:612\u20139.","journal-title":"J Opt Soc Am A"},{"key":"718_CR37","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1038\/nmeth.2019","volume":"9","author":"J Schindelin","year":"2012","unstructured":"Schindelin J, Arganda-Carreras I, Frise E, Kaynig V, Longair M, Pietzsch T, et al. Fiji: an open-source platform for biological-image analysis. Nat Methods. 2012;9:676\u201382.","journal-title":"Nat Methods"},{"key":"718_CR38","doi-asserted-by":"publisher","first-page":"308","DOI":"10.11607\/jomi.3756","volume":"30","author":"N Narra","year":"2015","unstructured":"Narra N, Antalainen AK, Zipprich H, S\u00e1ndor GK, Wolff J. Microcomputed tomography-based assessment of retrieved dental implants. Int J Oral Maxillofac Implants. 2015;30:308\u201314.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"718_CR39","doi-asserted-by":"publisher","first-page":"4491","DOI":"10.3390\/ma16124491","volume":"16","author":"J Kowalski","year":"2023","unstructured":"Kowalski J, Puszkarz AK, Radwanski M, Sokolowski J, Cichomski M, Bourgi R, et al. Micro-CT Evaluation of Microgaps at Implant-Abutment Connection. Mater (Basel). 2023;16:4491.","journal-title":"Mater (Basel)"},{"key":"718_CR40","doi-asserted-by":"publisher","first-page":"641","DOI":"10.11607\/ijp.6574","volume":"33","author":"I Ramalho","year":"2020","unstructured":"Ramalho I, Witek L, Coelho PG, Bergamo E, Pegoraro LF, Bonfante EA. Influence of Abutment Fabrication Method on 3D Fit at the Implant-Abutment Connection. Int J Prosthodont. 2020;33:641\u20137.","journal-title":"Int J Prosthodont"},{"key":"718_CR41","first-page":"793","volume":"27","author":"JP da Silva-Neto","year":"2012","unstructured":"da Silva-Neto JP, N\u00f3bilo MA, Penatti MP, Simamoto PC Jr., das Neves FD. Influence of methodologic aspects on the results of implant-abutment interface microleakage tests: a critical review of in vitro studies. Int J Oral Maxillofac Implants. 2012;27:793\u2013800.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"718_CR42","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1097\/SCS.0000000000002563","volume":"27","author":"A Scarano","year":"2016","unstructured":"Scarano A, Mortellaro C, Mavriqi L, Pecci R, Valbonetti L. Evaluation of Microgap With Three-Dimensional X-Ray Microtomography: Internal Hexagon Versus Cone Morse. J Craniofac Surg. 2016;27:682\u20135.","journal-title":"J Craniofac Surg"},{"key":"718_CR43","doi-asserted-by":"publisher","first-page":"7310175","DOI":"10.1155\/2019\/7310175","volume":"2019","author":"L Zuskova","year":"2019","unstructured":"Zuskova L, Mortadi NAA, Williams RJ, Alzoubi KH, Khabour OF. Comparison of Overall Fit of Milled and Laser-Sintered CAD\/CAM Crown Copings. Int J Dent. 2019;2019:7310175.","journal-title":"Int J Dent"},{"key":"718_CR44","doi-asserted-by":"publisher","first-page":"136","DOI":"10.11607\/ijp.5089","volume":"30","author":"R Alonso-P\u00e9rez","year":"2017","unstructured":"Alonso-P\u00e9rez R, Bartolom\u00e9 JF, Ferreiroa A, Salido MP, Prad\u00edes G. Evaluation of the Mechanical Behavior and Marginal Accuracy of Stock and Laser-Sintered Implant Abutments. Int J Prosthodont. 2017;30:136\u20138.","journal-title":"Int J Prosthodont"},{"key":"718_CR45","doi-asserted-by":"publisher","first-page":"4328","DOI":"10.3390\/app10124328","volume":"10","author":"I Campioni","year":"2020","unstructured":"Campioni I, Pecci R, Bedini R. Ten Years of Micro-CT in Dentistry and Maxillofacial Surgery: A Literature Overview. Appl Sci. 2020;10:4328.","journal-title":"Appl Sci"}],"container-title":["International Journal of Implant Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40729-026-00718-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-026-00718-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40729-026-00718-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T20:02:29Z","timestamp":1792440149000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40729-026-00718-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,13]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["718"],"URL":"https:\/\/doi.org\/10.1186\/s40729-026-00718-x","relation":{},"ISSN":["2198-4034"],"issn-type":[{"value":"2198-4034","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,13]]},"assertion":[{"value":"23 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable. This laboratory study did not involve human participants, identifiable human data, human tissue, or live animals.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"52"}}