{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T11:52:26Z","timestamp":1787313146569,"version":"build-2736575974"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T00:00:00Z","timestamp":1741824000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T00:00:00Z","timestamp":1741824000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Retin Vitr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to determine the optimal OCT angiography (OCT-A) scanning pattern using the SPECTRALIS HRA-OCT2 device to evaluate macular microvasculature perfusion in healthy subjects.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Healthy subjects were imaged using the SPECTRALIS OCT-A Module (Heidelberg Engineering) with the following scanning protocols: 10\u00baX10\u00ba-512 ART 7 [P1], 10\u00baX10\u00ba-256 ART 5 [P2], 10\u00baX10\u00ba-512 ART 5 [P3], and 15\u00baX10\u00ba-256 ART 5 [P4], all centered on the macula. Vessel perfusion density (VPD) and vessel length density (VLD) of the superficial vascular complex (SVC) were calculated using ImageJ software to evaluate the differences between scanning patterns. Three additional 10\u00bax1\u00ba, ART 7 high-density images were also obtained using the in-built software (SP-X1701 Update 3, based on Heyex Software Version 1.9.215.0\u00a0H) in the macular area and the VPD and VLD for all the three10\u00bax1\u00ba pattern size images with the corresponding area of pattern 1 image[P1]. Two retinal specialists conducted a blind qualitative assessment of the foveal avascular zone and image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Twenty eyes from 20 consecutive healthy patients were included in the study. The mean VPD for P1, P2, P3, and P4 were 35.60, 31.67, 31.18, and 31.16, respectively. Mean VLD for P1, P2, P3, and P4 were 7.54, 5.86, 6.74, and 4.40, respectively. Significant differences were found between P1 and the other patterns for both the VPD and VLD, but not between P2, P3, and P4. VPD and VLD for 10\u00bax1\u00ba high-density images were 33.20 and 4.61, respectively, with significant VLD differences compared to P1, but not for VPD. P1 scored the highest and P4 the lowest in the qualitative assessments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The 10\u00baX10\u00ba-512 ART 7 pattern showed statistically significant qualitative superiority and appeared optimal for blood flow detection with reduced noise in quantitative assessments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40942-025-00653-w","type":"journal-article","created":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T09:49:26Z","timestamp":1741859366000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["\u201cSetting the standard\u201d: an analysis of different acquisition patterns for macular OCT-angiography"],"prefix":"10.1186","volume":"11","author":[{"given":"Ramkailash","family":"Gujar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia","family":"Gregori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosa","family":"Dolz-Marco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessio","family":"Muzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Chhablani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Fruttini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Mangoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clara","family":"Rizzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesare","family":"Mariotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Lupidi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,13]]},"reference":[{"key":"653_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","volume":"64","author":"RF Spaide","year":"2018","unstructured":"Spaide RF, Fujimoto JG, Waheed NK, Sadda SR, Staurenghi G. Optical coherence tomography angiography. Prog Retin Eye Res. 2018;64:1\u201355.","journal-title":"Prog Retin Eye Res"},{"key":"653_CR2","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.1016\/j.ophtha.2019.05.022","volume":"126","author":"C Balaratnasingam","year":"2019","unstructured":"Balaratnasingam C, An D, Freund KB, Francke A, Yu D-Y. Correlation between histologic and OCT angiography analysis of macular circulation. Ophthalmology. 2019;126:1588\u20139.","journal-title":"Ophthalmology"},{"key":"653_CR3","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1097\/IAE.0000000000000765","volume":"35","author":"RF Spaide","year":"2015","unstructured":"Spaide RF, Fujimoto JG, Waheed NK. IMAGE ARTIFACTS IN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY. Retina. 2015;35:2163\u201380.","journal-title":"Retina"},{"key":"653_CR4","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.ajo.2017.11.011","volume":"186","author":"F Corvi","year":"2018","unstructured":"Corvi F, Pellegrini M, Erba S, Cozzi M, Staurenghi G, Giani A. Reproducibility of vessel density, fractal dimension, and foveal avascular zone using 7 different optical coherence tomography angiography devices. Am J Ophthalmol. 2018;186:25\u201331.","journal-title":"Am J Ophthalmol"},{"key":"653_CR5","doi-asserted-by":"publisher","first-page":"2102","DOI":"10.1097\/IAE.0000000000001458","volume":"37","author":"GN Magrath","year":"2017","unstructured":"Magrath GN, Say EAT, Sioufi K, Ferenczy S, Samara WA, Shields CL. Variability In Foveal Avascular Zone And Capillary Density Using Optical Coherence Tomography Angiography Machines In Healthy Eyes. Retina. 2017;37:2102\u201311.","journal-title":"Retina"},{"key":"653_CR6","doi-asserted-by":"publisher","first-page":"e0177059","DOI":"10.1371\/journal.pone.0177059","volume":"12","author":"MR Munk","year":"2017","unstructured":"Munk MR, Giannakaki-Zimmermann H, Berger L, Huf W, Ebneter A, Wolf S, et al. OCT-angiography: A qualitative and quantitative comparison of 4 OCT-A devices. PLoS ONE. 2017;12:e0177059.","journal-title":"PLoS ONE"},{"key":"653_CR7","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1167\/tvst.7.6.31","volume":"7","author":"T Shoji","year":"2018","unstructured":"Shoji T, Yoshikawa Y, Kanno J, Ishii H, Ibuki H, Ozaki K, et al. Reproducibility of macular vessel density calculations via imaging with two different Swept-Source optical coherence tomography angiography systems. Transl Vis Sci Technol. 2018;7:31.","journal-title":"Transl Vis Sci Technol"},{"key":"653_CR8","doi-asserted-by":"publisher","first-page":"e0206045","DOI":"10.1371\/journal.pone.0206045","volume":"13","author":"N Mihailovic","year":"2018","unstructured":"Mihailovic N, Brand C, Lahme L, Schubert F, Bormann E, Eter N, et al. Repeatability, reproducibility and agreement of foveal avascular zone measurements using three different optical coherence tomography angiography devices. PLoS ONE. 2018;13:e0206045.","journal-title":"PLoS ONE"},{"key":"653_CR9","first-page":"407","volume":"31","author":"Q Zhao","year":"2018","unstructured":"Zhao Q, Yang WL, Wang XN, Wang RK, You QS, Chu ZD, et al. Repeatability and reproducibility of quantitative assessment of the retinal microvasculature using optical coherence tomography angiography based on optical microangiography. Biomed Environ Sci. 2018;31:407\u201312.","journal-title":"Biomed Environ Sci"},{"key":"653_CR10","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/s00417-021-05229-6","volume":"260","author":"A Lentzsch","year":"2022","unstructured":"Lentzsch A, Sch\u00f6llhorn L, Schnorr C, Siggel R, Liakopoulos S. Comparison of swept-source versus spectral-domain optical coherence tomography angiography for detection of macular neovascularization. Graefes Arch Clin Exp Ophthalmol. 2022;260:113\u20139.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"653_CR11","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1167\/tvst.8.3.28","volume":"8","author":"H Ishii","year":"2019","unstructured":"Ishii H, Shoji T, Yoshikawa Y, Kanno J, Ibuki H, Shinoda K. Automated measurement of the foveal avascular zone in Swept-Source optical coherence tomography angiography images. Transl Vis Sci Technol. 2019;8:28.","journal-title":"Transl Vis Sci Technol"},{"key":"653_CR12","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1159\/000502458","volume":"243","author":"S Hosari","year":"2020","unstructured":"Hosari S, Hohberger B, Theelke L, Sari H, Lucio M, Mardin CY. OCT angiography: measurement of retinal macular microvasculature with spectralis II OCT Angiography - Reliability and reproducibility. Ophthalmologica. 2020;243:75\u201384.","journal-title":"Ophthalmologica"},{"key":"653_CR13","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.ajo.2018.03.029","volume":"190","author":"KB Freund","year":"2018","unstructured":"Freund KB, Gattoussi S, Leong BCS. Dense B-Scan optical coherence tomography angiography. Am J Ophthalmol. 2018;190:78\u201388.","journal-title":"Am J Ophthalmol"},{"key":"653_CR14","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.ajo.2019.10.033","volume":"211","author":"M Lupidi","year":"2020","unstructured":"Lupidi M, Fruttini D, Eandi CM, Nicol\u00f2 M, Cabral D, Tito S, et al. Chronic neovascular central serous chorioretinopathy: A stress\/rest optical coherence tomography angiography study. Am J Ophthalmol. 2020;211:63\u201375.","journal-title":"Am J Ophthalmol"},{"key":"653_CR15","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1001\/jamaophthalmol.2017.3431","volume":"135","author":"J Lei","year":"2017","unstructured":"Lei J, Durbin MK, Shi Y, Uji A, Balasubramanian S, Baghdasaryan E, et al. Repeatability and reproducibility of superficial macular retinal vessel density measurements using optical coherence tomography angiography En face images. JAMA Ophthalmol. 2017;135:1092\u20138.","journal-title":"JAMA Ophthalmol"},{"key":"653_CR16","doi-asserted-by":"publisher","first-page":"115","DOI":"10.4103\/tjo.tjo_31_17","volume":"7","author":"AM Hagag","year":"2017","unstructured":"Hagag AM, Gao SS, Jia Y, Huang D. Optical coherence tomography angiography: technical principles and clinical applications in ophthalmology. Taiwan J Ophthalmol. 2017;7:115\u201329.","journal-title":"Taiwan J Ophthalmol"},{"key":"653_CR17","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1159\/000471885","volume":"58","author":"M Lupidi","year":"2017","unstructured":"Lupidi M, Coscas G, Coscas F, Fiore T, Spaccini E, Fruttini D, et al. Retinal microvasculature in nonproliferative diabetic retinopathy: automated quantitative optical coherence tomography angiography assessment. Ophthalmic Res. 2017;58:131\u201341.","journal-title":"Ophthalmic Res"},{"key":"653_CR18","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1159\/000459688","volume":"60","author":"G Coscas","year":"2017","unstructured":"Coscas G, Lupidi M, Coscas F. Optical coherence tomography angiography in diabetic maculopathy. Dev Ophthalmol. 2017;60:38\u201349.","journal-title":"Dev Ophthalmol"},{"key":"653_CR19","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1111\/srt.12634","volume":"25","author":"V Teplyi","year":"2019","unstructured":"Teplyi V, Grebchenko K. Evaluation of the scars\u2019 vascularization using computer processing of the digital images. Skin Res Technol. 2019;25:194\u20139.","journal-title":"Skin Res Technol"},{"key":"653_CR20","doi-asserted-by":"publisher","first-page":"944","DOI":"10.1016\/j.ophtha.2017.02.006","volume":"124","author":"A Uji","year":"2017","unstructured":"Uji A, Balasubramanian S, Lei J, Baghdasaryan E, Al-Sheikh M, Sadda SR. Impact of multiple En face image averaging on quantitative assessment from optical coherence tomography angiography images. Ophthalmology. 2017;124:944\u201352.","journal-title":"Ophthalmology"},{"key":"653_CR21","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1016\/j.ophtha.2007.09.001","volume":"115","author":"A Sakamoto","year":"2008","unstructured":"Sakamoto A, Hangai M, Yoshimura N. Spectral-domain optical coherence tomography with multiple B-scan averaging for enhanced imaging of retinal diseases. Ophthalmology. 2008;115:1071\u2013e10787.","journal-title":"Ophthalmology"},{"key":"653_CR22","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.ajo.2015.04.021","volume":"160","author":"A Ishibazawa","year":"2015","unstructured":"Ishibazawa A, Nagaoka T, Takahashi A, Omae T, Tani T, Sogawa K, et al. Optical coherence tomography angiography in diabetic retinopathy: A prospective pilot study. Am J Ophthalmol. 2015;160:35\u2013e441.","journal-title":"Am J Ophthalmol"},{"key":"653_CR23","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.oret.2017.02.007","volume":"1","author":"A Faridi","year":"2017","unstructured":"Faridi A, Jia Y, Gao SS, Huang D, Bhavsar KV, Wilson DJ, et al. Sensitivity and specificity of OCT angiography to detect choroidal neovascularization. Ophthalmol Retina. 2017;1:294\u2013303.","journal-title":"Ophthalmol Retina"}],"container-title":["International Journal of Retina and Vitreous"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00653-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40942-025-00653-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00653-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T09:49:28Z","timestamp":1741859368000},"score":1,"resource":{"primary":{"URL":"https:\/\/journalretinavitreous.biomedcentral.com\/articles\/10.1186\/s40942-025-00653-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,13]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["653"],"URL":"https:\/\/doi.org\/10.1186\/s40942-025-00653-w","relation":{},"ISSN":["2056-9920"],"issn-type":[{"value":"2056-9920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,13]]},"assertion":[{"value":"23 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No conflicting relationships exist for any author.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All authors attest that they met the current ICMJE criteria for authorship.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Authorship"}}],"article-number":"28"}}