{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T04:49:50Z","timestamp":1786769390779,"version":"build-2736575974"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100010307","name":"Dr. F.P. Fischer-Stichting","doi-asserted-by":"crossref","award":["FS2021-1"],"award-info":[{"award-number":["FS2021-1"]}],"id":[{"id":"10.13039\/501100010307","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Stichting Blinden-Belang"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Retin Vitr"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Macular diseases (MD) lead to frequent clinic visits, involve time-consuming visual acuity (VA) measurements by professionals. Independent home measurements could improve efficiency. This study evaluates the agreement of a web-based test in MD compared to in-hospital measurements.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Adults with MD were included at the University Medical Center Utrecht in March-July 2023. Users need a phone, computer, and 3m distance. The test uses Tumbling-E and triangles as optotypes. Primary outcome is the web-based vs. ETDRS Distance Visual Acuity (DVA). Secondary outcomes were test-retest variability (TRV), near visual acuity (NVA), and the Amsler grid. Outcomes were reported in mean differences and 95% Limits of Agreement (LoA).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>89 eyes were included. The DVA mean difference was 0.03LogMAR(1.5 letters), SD0.17, LoA \u2212\u20090.31;0.36LogMAR(-15.5;18 letters), TRV had a mean difference of 0.03(1.5 letters) SD0.14. The NVA mean difference was 0.13(6.5 letter) SD0.24, positive- and negative predictive values 0.93(95%CI\u2009=\u20090.82;0.98) and 0.71(95%CI\u2009=\u20090.51;0.86) respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The agreement of the DVA web-based test is on par with Snellen line assessment and subpar to ETDRS. We showed that elderly can perform this test independently at home, providing a time- and cost-saving opportunity. Developments should focus on the NVA since it can be a valuable adjunct to MD follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration<\/jats:title>\n            <jats:p>the Dutch Medical Ethical committee (Medisch Ethische Toetsingscommissie; METC NedMec) registration number: 22\u2013879\/DB. Approved at 27-09-2022.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40942-025-00656-7","type":"journal-article","created":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T10:27:01Z","timestamp":1741948021000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Remote web-based self-assessment of visual acuity versus ETDRS in patients with macular diseases: a method comparison study"],"prefix":"10.1186","volume":"11","author":[{"given":"Casper","family":"van der Zee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leon Daniel Huang","family":"Huynh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saskia Marijke","family":"Imhof","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeannette","family":"Ossewaarde-van Norel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Redmer","family":"van Leeuwen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert Pieter Leendert","family":"Wisse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,14]]},"reference":[{"key":"656_CR1","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1016\/j.ajo.2014.06.012","volume":"158","author":"JB Jonas","year":"2014","unstructured":"Jonas JB, Bourne RRA, White RA, et al. Visual impairment and blindness due to macular diseases globally: A systematic review and Meta-Analysis. Am J Ophthalmol. 2014;158:808\u201315.","journal-title":"Am J Ophthalmol"},{"key":"656_CR2","doi-asserted-by":"publisher","first-page":"e106","DOI":"10.1016\/S2214-109X(13)70145-1","volume":"2","author":"WL Wong","year":"2014","unstructured":"Wong WL, Su X, Li X, et al. Global prevalence of age-related macular degeneration and disease burden projection for 2020 and 2040: a systematic review and meta-analysis. Lancet Glob Health. 2014;2:e106\u201316.","journal-title":"Lancet Glob Health"},{"key":"656_CR3","doi-asserted-by":"publisher","first-page":"556","DOI":"10.2337\/dc11-1909","volume":"35","author":"JWY Yau","year":"2012","unstructured":"Yau JWY, Rogers SL, Kawasaki R, et al. Global prevalence and major risk factors of diabetic retinopathy. Diabetes Care. 2012;35:556\u201364.","journal-title":"Diabetes Care"},{"key":"656_CR4","first-page":"125","volume":"115","author":"E Wang","year":"2023","unstructured":"Wang E, Chen Y. Central serous chorioretinopathy. Atlas Swept Source OCT OCT Angiography. 2023;115:125.","journal-title":"Atlas Swept Source OCT OCT Angiography"},{"key":"656_CR5","doi-asserted-by":"publisher","first-page":"e144","DOI":"10.1016\/S2214-109X(20)30489-7","volume":"9","author":"RRA Bourne","year":"2021","unstructured":"Bourne RRA, Steinmetz JD, Saylan M, et al. Causes of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: the right to sight: an analysis for the global burden of disease study. Lancet Glob Health. 2021;9:e144\u201360.","journal-title":"Lancet Glob Health"},{"key":"656_CR6","unstructured":"Pati\u00ebntenfederatie Nederland. Generieke adviezen over Zorg op afstand. https:\/\/www.patientenfederatie.nl\/downloads\/rapporten\/1701-adviesrapport-generieke-aanbevelingen-zorg-op-afstand\/file (2024, accessed 3 February 2025)."},{"key":"656_CR7","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1038\/s41746-019-0154-5","volume":"2","author":"WK Yeung","year":"2019","unstructured":"Yeung WK, Dawes P, Pye A, et al. eHealth tools for the self-testing of visual acuity: a scoping review. NPJ Digit Med. 2019;2:82.","journal-title":"NPJ Digit Med"},{"key":"656_CR8","doi-asserted-by":"publisher","unstructured":"Keesara S, Jonas A, Schulman K. Covid-19 and Health Care\u2019s Digital Revolution. New England Journal of Medicine, 382. Epub ahead of print 4 June 2020. https:\/\/doi.org\/10.1056\/NEJMP2005835\/SUPPL_FILE\/NEJMP2005835_DISCLOSURES.PDF","DOI":"10.1056\/NEJMP2005835\/SUPPL_FILE\/NEJMP2005835_DISCLOSURES.PDF"},{"key":"656_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12886-023-02779-7","volume":"23","author":"JLJ Claessens","year":"2023","unstructured":"Claessens JLJ, Wanten JC, Bauer NJC, et al. Remote follow-up after cataract surgery (CORE-RCT): study protocol of a randomized controlled trial. BMC Ophthalmol. 2023;23:1\u20137.","journal-title":"BMC Ophthalmol"},{"key":"656_CR10","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1097\/j.jcrs.0000000000001108","volume":"49","author":"JC Wanten","year":"2023","unstructured":"Wanten JC, Bauer NJC, Claessens JLJ, et al. Evaluation of a visual acuity eHealth tool in patients with cataract. J Cataract Refract Surg. 2023;49:278\u201384.","journal-title":"J Cataract Refract Surg"},{"key":"656_CR11","doi-asserted-by":"publisher","first-page":"e41045","DOI":"10.2196\/41045","volume":"7","author":"J Claessens","year":"2023","unstructured":"Claessens J, van Egmond J, Wanten J, et al. The accuracy of a Web-Based visual acuity Self-assessment tool performed independently by eye care patients at home: method comparison study. JMIR Form Res. 2023;7:e41045.","journal-title":"JMIR Form Res"},{"key":"656_CR12","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1097\/00006324-197611000-00006","volume":"53","author":"IL Bailey","year":"1976","unstructured":"Bailey IL, Lovie JE. New design principles for visual acuity letter charts. Optom Vis Sci. 1976;53:740\u20135.","journal-title":"Optom Vis Sci"},{"key":"656_CR13","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1038\/eye.2009.147","volume":"24","author":"L-A Lim","year":"2010","unstructured":"Lim L-A, Frost NA, Powell RJ, et al. Comparison of the ETDRS LogMAR, \u2018compact reduced logmar\u2019 and Snellen charts in routine clinical practice. Eye (Lond). 2010;24:673\u20137.","journal-title":"Eye (Lond)"},{"key":"656_CR14","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1136\/bjo.85.4.432","volume":"85","author":"DA Rosser","year":"2001","unstructured":"Rosser DA. The development of a \u2018reduced logmar\u2019 visual acuity chart for use in routine clinical practice. Br J Ophthalmol. 2001;85:432\u20136.","journal-title":"Br J Ophthalmol"},{"key":"656_CR15","first-page":"311","volume":"107","author":"PK Kaiser","year":"2009","unstructured":"Kaiser PK. Prospective evaluation of visual acuity assessment: a comparison of Snellen versus ETDRS charts in clinical practice (An AOS Thesis). Trans Am Ophthalmol Soc. 2009;107:311\u201324.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"656_CR16","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.survophthal.2018.08.003","volume":"64","author":"V Vargas","year":"2019","unstructured":"Vargas V, Radner W, Allan BD, et al. Methods for the study of near, intermediate vision, and accommodation: an overview of subjective and objective approaches. Surv Ophthalmol. 2019;64:90\u2013100.","journal-title":"Surv Ophthalmol"},{"key":"656_CR17","first-page":"2508","volume":"43","author":"D Chesnutt","year":"2002","unstructured":"Chesnutt D, Stinnett S, Mahmoud T. The Amsler grid: white on black or black on white? Invest Ophthalmol Vis Sci. 2002;43:2508\u20132508.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"656_CR20","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1034\/j.1600-0420.1999.770613.x","volume":"77","author":"J Siderov","year":"1999","unstructured":"Siderov J, Tiu AL. Variability of measurements of visual acuity in a large eye clinic. Acta Ophthalmol Scand. 1999;77:673\u20136.","journal-title":"Acta Ophthalmol Scand"},{"key":"656_CR21","doi-asserted-by":"publisher","unstructured":"Van der Zee C, Muijzer M, Claessens J et al. Determining the variability associated with measuring visual acuity and refractive error measurements: a systematic review. Epub ahead of print 17 January 2025. https:\/\/doi.org\/10.1101\/2025.01.17.25320329","DOI":"10.1101\/2025.01.17.25320329"},{"key":"656_CR22","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307\u201310.","journal-title":"Lancet"},{"key":"656_CR23","doi-asserted-by":"publisher","first-page":"141","DOI":"10.11613\/BM.2015.015","volume":"25","author":"D Giavarina","year":"2015","unstructured":"Giavarina D. Understanding Bland Altman analysis. Biochem Med (Zagreb). 2015;25:141\u201351.","journal-title":"Biochem Med (Zagreb)"},{"key":"656_CR24","doi-asserted-by":"publisher","first-page":"c332","DOI":"10.1136\/bmj.c332","volume":"340","author":"KF Schulz","year":"2010","unstructured":"Schulz KF, Altman DG, Moher D. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c332\u2013332.","journal-title":"BMJ"},{"key":"656_CR25","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1016\/S0140-6736(07)61602-X","volume":"370","author":"E von Elm","year":"2007","unstructured":"von Elm E, Altman DG, Egger M, et al. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. Lancet. 2007;370:1453\u20137.","journal-title":"Lancet"},{"key":"656_CR26","doi-asserted-by":"publisher","first-page":"h5527","DOI":"10.1136\/bmj.h5527","volume":"351","author":"PM Bossuyt","year":"2015","unstructured":"Bossuyt PM, Reitsma JB, Bruns DE, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ. 2015;351:h5527.","journal-title":"BMJ"},{"key":"656_CR27","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.1007\/s00417-019-04344-9","volume":"257","author":"A Mataftsi","year":"2019","unstructured":"Mataftsi A, Koutsimpogeorgos D, Brazitikos P, et al. Is conversion of decimal visual acuity measurements to LogMAR values reliable? Graefe\u2019s Archive Clin Experimental Ophthalmol. 2019;257:1513\u20137.","journal-title":"Graefe\u2019s Archive Clin Experimental Ophthalmol"},{"key":"656_CR28","doi-asserted-by":"publisher","first-page":"859","DOI":"10.2147\/OPTH.S304272","volume":"15","author":"N Tiraset","year":"2021","unstructured":"Tiraset N, Poonyathalang A, Padungkiatsagul T, et al. Comparison of visual acuity measurement using three methods: standard ETDRS chart, near chart and a Smartphone-Based eye chart application. Clin Ophthalmol. 2021;15:859\u201369.","journal-title":"Clin Ophthalmol"},{"key":"656_CR29","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1016\/j.jcrs.2009.03.026","volume":"35","author":"N Gupta","year":"2009","unstructured":"Gupta N, Wolffsohn JSW, Naroo SA. Comparison of near visual acuity and reading metrics in presbyopia correction. J Cataract Refract Surg. 2009;35:1401\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"656_CR30","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.jcrs.2004.01.014","volume":"30","author":"JT Holladay","year":"2004","unstructured":"Holladay JT. Visual acuity measurements. J Cataract Refract Surg. 2004;30:287\u201390.","journal-title":"J Cataract Refract Surg"},{"key":"656_CR31","doi-asserted-by":"publisher","first-page":"1915","DOI":"10.1097\/IAE.0b013e318285cc0c","volume":"33","author":"M Munk","year":"2013","unstructured":"Munk M, Kiss C, Huf W, et al. Therapeutic interventions for macular diseases show characteristic effects on near and distance visual function. Retina. 2013;33:1915\u201322.","journal-title":"Retina"},{"key":"656_CR32","doi-asserted-by":"publisher","first-page":"1736","DOI":"10.1016\/j.ophtha.2021.07.025","volume":"128","author":"S Sivaprasad","year":"2021","unstructured":"Sivaprasad S, Banister K, Azuro-Blanco A, et al. Diagnostic accuracy of monitoring tests of fellow eyes in patients with unilateral neovascular Age-Related macular degeneration: early detection of neovascular Age-Related macular degeneration study. Ophthalmology. 2021;128:1736\u201347.","journal-title":"Ophthalmology"},{"key":"656_CR33","first-page":"004695802210962","volume":"59","author":"F Mubarak","year":"2022","unstructured":"Mubarak F, Suomi R. Elderly forgotten?? digital exclusion in the information age and the rising grey digital divide. INQUIRY: J Health Care Organ Provis Financing. 2022;59:004695802210962.","journal-title":"INQUIRY: J Health Care Organ Provis Financing"},{"key":"656_CR34","unstructured":"Internet. toegang, gebruik en faciliteiten; 2012\u20132019| CBS. https:\/\/www.cbs.nl\/nl-nl\/cijfers\/detail\/83429NED?dl=2F8AA (accessed 5 February 2024)."},{"key":"656_CR35","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1007\/s40123-021-00360-3","volume":"10","author":"JLJ Claessens","year":"2021","unstructured":"Claessens JLJ, Geuvers JR, Imhof SM, et al. Digital tools for the Self-Assessment of visual acuity: A systematic review. Ophthalmol Ther. 2021;10:715\u201330.","journal-title":"Ophthalmol Ther"},{"key":"656_CR36","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1007\/s40123-019-0203-9","volume":"8","author":"J Brucker","year":"2019","unstructured":"Brucker J, Bhatia V, Sahel JA, et al. Odysight: A mobile medical application designed for remote Monitoring\u2014A prospective study comparison with standard clinical eye tests. Ophthalmol Ther. 2019;8:461\u201376.","journal-title":"Ophthalmol Ther"},{"key":"656_CR37","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s40123-023-00854-2","volume":"13","author":"A Joseph","year":"2024","unstructured":"Joseph A, Bullimore M, Drawnel F, et al. Remote monitoring of visual function in patients with maculopathy: the aphelion study. Ophthalmol Ther. 2024;13:409\u201322.","journal-title":"Ophthalmol Ther"}],"container-title":["International Journal of Retina and Vitreous"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00656-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40942-025-00656-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00656-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T10:27:09Z","timestamp":1741948029000},"score":1,"resource":{"primary":{"URL":"https:\/\/journalretinavitreous.biomedcentral.com\/articles\/10.1186\/s40942-025-00656-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,14]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["656"],"URL":"https:\/\/doi.org\/10.1186\/s40942-025-00656-7","relation":{},"ISSN":["2056-9920"],"issn-type":[{"value":"2056-9920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,14]]},"assertion":[{"value":"15 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was performed in accordance with local laws and regulations, the Declaration of Helsinki, and the 2015 Standards for Reporting Diagnostic Accuracy Studies (STARD) []. The data was stored on GDPR and HIPAA compliant servers in the EU. Medical- with informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"RW is a shareholder and consultant of Easee BV. CZ, LH, JO, RL, and SI are independent researchers from the University Medical Center Utrecht. The authors have no additional financial or proprietary interest in the materials presented herein.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"29"}}