{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T15:02:05Z","timestamp":1787238125354,"version":"build-2736575974"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T00:00:00Z","timestamp":1747612800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T00:00:00Z","timestamp":1747612800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Retin Vitr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>This study aimed to characterize the clinical results and usability of intraoperative optical coherence tomography (iOCT) associated with a digital visualization system in vitreoretinal surgery for macular hole correction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This is a descriptive observational study of patients undergoing vitreoretinal surgery for macular hole at Brazilian Eye Surgery Center in which the digital visualization system associated with iOCT was used. Anatomical and functional results were collected 6\u00a0months after surgery. Macular hole closure rates, pre- and post-operative visual acuity were measured in addition to surgeon feedback and the percentage in which the technology allowed intraoperative decision-making.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>25 eyes of 25 patients were included in the study. The mean preoperative visual acuity was 20\/100, ranging from 20\/50 to less than 20\/400, and postoperative visual acuity was 20\/60, ranging from 20\/25 to less than 20\/400. The time spent with iOCT did not result in surgical delay, as the average time spent was 3.24 extra minutes spent per surgery. Closure of the macular hole was achieved successfully in 92% of cases. In 8% of them surgical success in closing the macular hole was achieved after a new fluid-gas exchange in the office. The surgeon preferred real-time iOCT and, in 4% (1\/25) of cases, it influenced the change in surgical technique, preventing unnecessary ILM (Internal Limiting Membrane) peeling after complete removal of the posterior hyaloid and closing the macular hole. In all cases the surgeon reported valid feedback regarding the use of information provided by real-time OCT. This tool was valid for confirming complete ILM peeling in all cases in which it was performed. Finally, iOCT made it possible to identify the appropriate location to begin creating the ILM flap in 2 cases (8%) both of fragile retina; It prevented a new injection of dyes to identify residual ILM in 8% of cases (2\/25) and allowed verification of the correct positioning of the pedicled ILM flap over the hole in 16% (4\/25) of cases. Therefore, in 36% of cases (9\/25) iOCT was essential for the final surgical outcome.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This study suggests that the use of iOCT integrated with a digital viewing microscope for the treatment of macular holes offers high standard usability and effectiveness for visualizing structures, and impact favorably on decision-making process during pars-plana vitrectomy. These findings suggest that in the near future, expanded use of iOCT could significantly improve tissue management at the vitreomacular interface and improve anatomical and functional results.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40942-025-00671-8","type":"journal-article","created":{"date-parts":[[2025,5,18]],"date-time":"2025-05-18T22:32:39Z","timestamp":1747607559000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Pioneering evaluation in Brazil of microscope-integrated optical coherence tomography with a three-dimensional digital visualization system during pars plana vitrectomy for the treatment of macular hole"],"prefix":"10.1186","volume":"11","author":[{"given":"Leticia Pinheiro","family":"de Freitas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamil Miguel","family":"Neto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"La\u00eds Lauria","family":"Neves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thais","family":"Bastos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre Caiado Ferreira","family":"Pires","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ant\u00f4nio Marcelo Barbante","family":"Casella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Leonardo Cruvinel","family":"Isaac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcos Pereira","family":"de \u00c1vila","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,19]]},"reference":[{"issue":"1","key":"671_CR1","doi-asserted-by":"publisher","first-page":"10031","DOI":"10.1038\/s41598-021-88993-z","volume":"11","author":"P Kantor","year":"2021","unstructured":"Kantor P, et al. Use of the heads-up NGENUITY 3D visualization system for vitreoretinal surgery: a retrospective evaluation of outcomes in a French tertiary center. Sci Rep. 2021;11(1):10031.","journal-title":"Sci Rep"},{"issue":"4","key":"671_CR2","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1002\/micr.1920010407","volume":"1","author":"JI Barraquer","year":"1980","unstructured":"Barraquer JI. The history of the microscope in ocular surgery. J Microsurg. 1980;1(4):288\u201399.","journal-title":"J Microsurg"},{"key":"671_CR3","doi-asserted-by":"publisher","unstructured":"Oliveira PRC, Berger AR, Chow DR. Vitreoretinal instruments: vitrectomy cutters, endoillumination and wide-angle viewing systems. Int J Retin Vitreous. 2016;2:28. https:\/\/doi.org\/10.1186\/s40942-016-0052-9.","DOI":"10.1186\/s40942-016-0052-9"},{"issue":"1","key":"671_CR4","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1097\/IAE.0000000000000689","volume":"36","author":"C Eckardt","year":"2016","unstructured":"Eckardt C, Paulo EB. Heads-up surgery for vitreoretinal procedures. Retina. 2016;36(1):137\u201347.","journal-title":"Retina"},{"issue":"5","key":"671_CR5","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1590\/s0034-72802009000500010","volume":"68","author":"DC Ferrara","year":"2009","unstructured":"Ferrara DC, et al. Avalia\u00e7\u00e3o ocular multimodal em doen\u00e7as heredodistr\u00f3ficas e degenerativas da retina. Revista Brasileira de Oftalmologia. 2009;68(5):309\u201317. https:\/\/doi.org\/10.1590\/s0034-72802009000500010.","journal-title":"Revista Brasileira de Oftalmologia"},{"issue":"1","key":"671_CR6","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1186\/s12886-024-03361-5","volume":"24","author":"A Kelkar","year":"2024","unstructured":"Kelkar A, et al. Comparison of cognitive workload and surgical outcomes between a three-dimensional and conventional microscope macular hole surgery. BMC Ophthalmol. 2024;24(1):95.","journal-title":"BMC Ophthalmol"},{"key":"671_CR7","unstructured":"Carl Zeiss Meditec AG. Zeiss Clarus 700. https:\/\/www.zeiss.com\/meditec\/int\/products\/ophthalmology-optometry\/retina\/clarus.html. Accessed 22 Apr 2025."},{"key":"671_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s40942-022-00439-4","author":"FA Rezende","year":"2023","unstructured":"Rezende FA, et al. Surgical classification for large macular hole: based on different surgical techniques results: the CLOSE study group. Int J Retina Vitreous. 2023. https:\/\/doi.org\/10.1186\/s40942-022-00439-4.","journal-title":"Int J Retina Vitreous"},{"key":"671_CR9","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.1016\/j.ophtha.2010.02.011","volume":"117","author":"Z Michalewska","year":"2010","unstructured":"Michalewska Z, et al. Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology. 2010;117:2018\u201325.","journal-title":"Ophthalmology"},{"key":"671_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/s40942-020-00248-7","author":"JES da Tavares Neto","year":"2020","unstructured":"da Tavares Neto JES, et al. Pedicle internal limiting membrane flap technique for very large macular holes: a preliminary report. Int J Retina Vitreous. 2020. https:\/\/doi.org\/10.1186\/s40942-020-00248-7.","journal-title":"Int J Retina Vitreous"},{"issue":"9","key":"671_CR11","doi-asserted-by":"publisher","first-page":"1889","DOI":"10.1016\/j.ophtha.2015.05.040","volume":"122","author":"CC Lai","year":"2015","unstructured":"Lai CC, et al. Vitrectomy with internal limiting membrane repositioning and autologous blood for macular hole retinal detachment in highly myopic eyes. Ophthalmology. 2015;122(9):1889\u201398. https:\/\/doi.org\/10.1016\/j.ophtha.2015.05.040.","journal-title":"Ophthalmology"},{"key":"671_CR12","unstructured":"Carl Zeiss Meditec, AG. Zeiss Artevo 800. Carl Zeiss Meditec AG. 2019. https:\/\/www.zeiss.com\/content\/dam\/med\/ref_international\/products\/surgical-microscopes\/ophthalmic-microscopes\/artevo-800\/documents\/artevo800_en_32_010_0070ii.pdf. Accessed 2 July 2023."},{"issue":"4","key":"671_CR13","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1080\/08820538.2019.1620811","volume":"34","author":"C Ung","year":"2019","unstructured":"Ung C, Miller JB. Intraoperative optical coherence tomography in vitreoretinal surgery. Semin Ophthalmol. 2019;34(4):312\u20136. https:\/\/doi.org\/10.1080\/08820538.2019.1620811.","journal-title":"Semin Ophthalmol"},{"issue":"2","key":"671_CR14","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/s0161-6420(95)31032-9","volume":"102","author":"CA Puliafito","year":"1995","unstructured":"Puliafito CA, et al. Imaging of macular diseases with optical coherence tomography. Ophthalmology. 1995;102(2):217\u201329. https:\/\/doi.org\/10.1016\/s0161-6420(95)31032-9.","journal-title":"Ophthalmology"},{"key":"671_CR15","first-page":"1005","volume-title":"Retina e v\u00edtreo - cl\u00ednica e cirurgia","author":"MP de \u00c1vila","year":"1999","unstructured":"de \u00c1vila MP, BrasilFilho COM, De Macular B. Retina e v\u00edtreo - cl\u00ednica e cirurgia. Sao Paulo: ROCA; 1999. p. 1005\u201313."},{"key":"671_CR16","volume-title":"Vitrectomia 20, 23 and 25 gauge","author":"M \u00c1vila","year":"2010","unstructured":"\u00c1vila M, Isaac D. Vitrectomia 20, 23 and 25 gauge. 19th ed. Rio de Janeiro: Ed. Cultura M\u00e9dica; 2010.","edition":"19"},{"issue":"12","key":"671_CR17","doi-asserted-by":"publisher","first-page":"2652","DOI":"10.1097\/IAE.0000000000000754","volume":"35","author":"SW Park","year":"2015","unstructured":"Park SW, et al. Perfluoro-n-octane assisted free internal limiting membrane flap technique for recurrent macular hole. Retina. 2015;35(12):2652\u20136. https:\/\/doi.org\/10.1097\/IAE.0000000000000754.","journal-title":"Retina"},{"key":"671_CR18","doi-asserted-by":"publisher","DOI":"10.5935\/0004-2749.20200044","author":"ALC de Bastos","year":"2020","unstructured":"de Bastos ALC, M., et al. Surgical results regarding the correction of macular hole with and without face-down posturing using 25% SF6 gas: a retrospective case series. Arquivos Brasileiros de Oftalmologia. 2020. https:\/\/doi.org\/10.5935\/0004-2749.20200044.","journal-title":"Arquivos Brasileiros de Oftalmologia"},{"issue":"12","key":"671_CR19","doi-asserted-by":"publisher","first-page":"663","DOI":"10.3928\/23258160-20211126-01","volume":"52","author":"DV Singh","year":"2022","unstructured":"Singh DV, et al. Epiretinal membrane from uncontrolled gliosis after inverted ILM flap technique for idiopathic macular hole. Ophthalmic Surg Lasers Imaging Retina. 2022;52(12):663\u20135. https:\/\/doi.org\/10.3928\/23258160-20211126-01.","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"671_CR20","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.ajo.2016.06.041","volume":"169","author":"K Bae","year":"2016","unstructured":"Bae K, et al. Extent of internal limiting membrane peeling and its impact on macular hole surgery outcomes: a randomized trial. Am J Ophthalmol. 2016;169:179\u201388. https:\/\/doi.org\/10.1016\/j.ajo.2016.06.041.","journal-title":"Am J Ophthalmol"},{"key":"671_CR21","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1038\/eye.2015.255","volume":"30","author":"J Ehlers","year":"2016","unstructured":"Ehlers J. Intraoperative optical coherence tomography: past, present, and future. Eye, London. 2016;30:193\u2013201. https:\/\/doi.org\/10.1038\/eye.2015.255.","journal-title":"Eye, London"}],"container-title":["International Journal of Retina and Vitreous"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00671-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40942-025-00671-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00671-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,18]],"date-time":"2025-05-18T22:32:41Z","timestamp":1747607561000},"score":1,"resource":{"primary":{"URL":"https:\/\/journalretinavitreous.biomedcentral.com\/articles\/10.1186\/s40942-025-00671-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,19]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["671"],"URL":"https:\/\/doi.org\/10.1186\/s40942-025-00671-8","relation":{},"ISSN":["2056-9920"],"issn-type":[{"value":"2056-9920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,19]]},"assertion":[{"value":"24 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research was approved by the Ethics Research Committee of the Federal University of Goi\u00e1s (number 78625824.0.0000.5083). Informed consent was obtained from all participants included. The procedures used were in accordance with the tenets of the Declaration of Helsinki for research involving human beings.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"57"}}