{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T18:01:34Z","timestamp":1795111294045,"version":"4.10.3"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T00:00:00Z","timestamp":1750377600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T00:00:00Z","timestamp":1750377600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Retin Vitr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The study underscores the importance of conducting objective measurements of intraocular lens (IOL) tilt and decentration over time to provide evidence of IOL stability. The goals were to validate a new method for measuring tilt and decentration of secondary implants and evaluate the postoperative functional and anatomic outcomes of 4-support IOL scleral fixation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective study (7 patients, seven eyes) was conducted from October 2020 to April 2021 at the Department of Ophthalmology, Federal University of S\u00e3o Paulo, S\u00e3o Paulo, and Technological Institute of Aeronautics, S\u00e3o Jos\u00e9 dos Campos, Brazil. The patients underwent combined vitrectomy and implantation of a 4-point scleral fixation IOL. The subjective refraction with the logarithm of the minimum angle of resolution (logMAR) best-corrected visual acuity (BCVA), slit-lamp examination, Goldmann applanation tonometry, wide-field retinography, and Scheimpflug corneal tomography and topography were performed preoperatively and postoperatively. Macular optical coherence tomography (OCT) was performed to assess the presence of macular edema. Anterior-segment OCT and ultrasound biomicroscopy (UBM) were performed to measure IOL positioning. The method for measuring IOL positioning was validated. Surgery outcomes included BCVA, refraction, and IOL tilt and decentration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      High intra-class correlations (0.781 to 0.999) were found for the intra- and inter-observer measurements of the UBM and OCT images. Measurements obtained using the scleral spur (SS) as an anatomic reference are comparable to those obtained using the iris pigmented epithelium (IPE) plane as a reference. Conversely, the measurements taken with OCT images cannot be compared to those obtained with UBM images. The logMAR BCVA improved from 0.59\u2009\u00b1\u20090.13 preoperatively to 0.24\u2009\u00b1\u20090.34 at 6 months postoperatively (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.001). The mean tilt using anterior-segment OCT was 1.15\u2009\u00b1\u20091.26 degrees. The mean decentration on UBM images was 0.58\u2009\u00b1\u20090.63\u00a0mm; no significant changes in IOL position were observed between 1 and 6 months postoperatively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The methodology exhibits strong reproducibility and enabled valid comparisons of tilt and decentration across the SS and IPE. Four-support IOL scleral fixation yields favorable surgical outcomes with physiologic IOL position and maintains stability throughout the follow-up period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>The Federal University of S\u00e3o Paulo institution\u2019s Research Ethics Committee reviewed and approved this study protocol (Approval Number, 4.261.258).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s40942-025-00690-5","type":"journal-article","created":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T03:16:26Z","timestamp":1750389386000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Assessment of tilt and decentration of a 4-point scleral fixated intraocular lens using an innovative digital measurement methodology"],"prefix":"10.1186","volume":"11","author":[{"given":"Denise","family":"Pardini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica MS","family":"Matsumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Roizenblatt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana Marisa","family":"Branco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulo","family":"Schor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norma","family":"Allemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Farah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9","family":"Maia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maur\u00edcio","family":"Maia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,20]]},"reference":[{"issue":"9","key":"690_CR1","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1016\/j.ophtha.2020.03.005","volume":"127","author":"JF Shen","year":"2020","unstructured":"Shen JF, et al. Intraocular Lens implantation in the absence of zonular support: an outcomes and safety update: A report by the American academy of ophthalmology. Ophthalmology. 2020;127(9):1234\u201358.","journal-title":"Ophthalmology"},{"issue":"8","key":"690_CR2","doi-asserted-by":"publisher","first-page":"1602","DOI":"10.1097\/IAE.0000000000001147","volume":"36","author":"MA Khan","year":"2016","unstructured":"Khan MA, et al. Combined 27-Gauge Pars plana vitrectomy and scleral fixation of an Akreos AO60 intraocular Lens using Gore-Tex suture. Retina. 2016;36(8):1602\u20134.","journal-title":"Retina"},{"issue":"1","key":"690_CR3","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.oret.2022.07.006","volume":"7","author":"D Pardini","year":"2023","unstructured":"Pardini D, et al. Outcomes of Pars plana vitrectomy and 4-Point sutured scleral fixation of Akreos AO60 intraocular Lens in clinical settings: A case series. Ophthalmol Retina. 2023;7(1):59\u201366.","journal-title":"Ophthalmol Retina"},{"key":"690_CR4","doi-asserted-by":"publisher","first-page":"4431","DOI":"10.2147\/OPTH.S282094","volume":"14","author":"NA Patel","year":"2020","unstructured":"Patel NA, et al. Refractive outcomes of Four-Point scleral fixation of Akreos AO60 intraocular Lens using Gore-Tex suture. Clin Ophthalmol. 2020;14:4431\u20137.","journal-title":"Clin Ophthalmol"},{"issue":"5","key":"690_CR5","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/S0886-3350(13)80002-8","volume":"19","author":"CJ Pavlin","year":"1993","unstructured":"Pavlin CJ, et al. Determination of haptic position of transsclerally fixated posterior chamber intraocular lenses by ultrasound biomicroscopy. J Cataract Refract Surg. 1993;19(5):573\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"690_CR6","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1111\/j.1442-9071.2008.01892.x","volume":"37","author":"RH Silverman","year":"2009","unstructured":"Silverman RH. High-resolution ultrasound imaging of the eye - a review. Clin Exp Ophthalmol. 2009;37(1):54\u201367.","journal-title":"Clin Exp Ophthalmol"},{"issue":"3","key":"690_CR7","doi-asserted-by":"publisher","first-page":"e59109","DOI":"10.1371\/journal.pone.0059109","volume":"8","author":"X Wang","year":"2013","unstructured":"Wang X, et al. IOL Tilt and decentration Estimation from 3 dimensional reconstruction of OCT image. PLoS ONE. 2013;8(3):e59109.","journal-title":"PLoS ONE"},{"key":"690_CR8","unstructured":"Hill W. Surgically Induced Astigmatism Calculator. 07\/03\/2023]; Available from: http:\/\/sia-calculator.com"},{"key":"690_CR9","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/s40942-019-0182-y","volume":"5","author":"BF Marianelli","year":"2019","unstructured":"Marianelli BF, et al. Observational study of intraocular lens Tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy. Int J Retina Vitreous. 2019;5:33.","journal-title":"Int J Retina Vitreous"},{"issue":"6","key":"690_CR10","doi-asserted-by":"publisher","first-page":"525","DOI":"10.5301\/ejo.5000652","volume":"25","author":"GM Cavallini","year":"2015","unstructured":"Cavallini GM, et al. Long-term analysis of IOL stability of the Lewis technique for scleral fixation. Eur J Ophthalmol. 2015;25(6):525\u20138.","journal-title":"Eur J Ophthalmol"},{"issue":"1","key":"690_CR11","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","volume":"121","author":"S Yamane","year":"2014","unstructured":"Yamane S, et al. Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection. Ophthalmology. 2014;121(1):61\u20136.","journal-title":"Ophthalmology"},{"issue":"5","key":"690_CR12","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1097\/j.jcrs.0000000000000135","volume":"46","author":"F Barca","year":"2020","unstructured":"Barca F, et al. Trans-scleral plugs fixated IOL: a new paradigm for sutureless scleral fixation. J Cataract Refract Surg. 2020;46(5):716\u201320.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"690_CR13","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1016\/S0161-6420(90)32422-3","volume":"97","author":"DL Guyton","year":"1990","unstructured":"Guyton DL, Uozato H, Wisnicki HJ. Rapid determination of intraocular lens Tilt and decentration through the undilated pupil. Ophthalmology. 1990;97(10):1259\u201364.","journal-title":"Ophthalmology"},{"issue":"1","key":"690_CR14","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ophtha.2014.07.032","volume":"122","author":"DA Kumar","year":"2015","unstructured":"Kumar DA, et al. Long-term assessment of Tilt of glued intraocular lenses: an optical coherence tomography analysis 5 years after surgery. Ophthalmology. 2015;122(1):48\u201355.","journal-title":"Ophthalmology"},{"issue":"1","key":"690_CR15","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1186\/s12886-022-02430-x","volume":"22","author":"G Calzetti","year":"2022","unstructured":"Calzetti G, et al. Tilt and decentration of posterior and anterior iris-claw intraocular lenses: a pilot study using anterior segment optical coherence tomography. BMC Ophthalmol. 2022;22(1):233.","journal-title":"BMC Ophthalmol"},{"key":"690_CR16","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1007\/978-3-031-50666-6_61","volume-title":"Intraocular Lens calculations","author":"N Hirnschall","year":"2024","unstructured":"Hirnschall N, Findl O. Lens and IOL Tilt. In: Aramberri J, et al. editors. Intraocular Lens calculations. Cham: Springer International Publishing; 2024. pp. 857\u201369."},{"issue":"9","key":"690_CR17","doi-asserted-by":"publisher","first-page":"e0184066","DOI":"10.1371\/journal.pone.0184066","volume":"12","author":"S Kimura","year":"2017","unstructured":"Kimura S, et al. Assessment of Tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS ONE. 2017;12(9):e0184066.","journal-title":"PLoS ONE"},{"key":"690_CR18","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1186\/s12886-015-0146-4","volume":"15","author":"M Forlini","year":"2015","unstructured":"Forlini M, et al. Long-term follow-up of retropupillary iris-claw intraocular lens implantation: a retrospective analysis. BMC Ophthalmol. 2015;15:143.","journal-title":"BMC Ophthalmol"},{"issue":"8","key":"690_CR19","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1016\/j.jcrs.2013.03.004","volume":"39","author":"DA Kumar","year":"2013","unstructured":"Kumar DA, et al. Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules. J Cataract Refract Surg. 2013;39(8):1211\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"690_CR20","doi-asserted-by":"crossref","unstructured":"Ashena Z et al. Effect of intraocular Lens Tilt and decentration on visual acuity, dysphotopsia and wavefront aberrations. Vis (Basel), 2020;4(3).","DOI":"10.3390\/vision4030041"},{"issue":"6","key":"690_CR21","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1016\/j.jcrs.2018.04.035","volume":"44","author":"MP Weikert","year":"2018","unstructured":"Weikert MP, Golla A, Wang L. Astigmatism induced by intraocular lens Tilt evaluated via ray tracing. J Cataract Refract Surg. 2018;44(6):745\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"690_CR22","doi-asserted-by":"publisher","first-page":"p153963","DOI":"10.1155\/2015\/153963","volume":"2015","author":"HA Ibrahim","year":"2015","unstructured":"Ibrahim HA, Sabry HN. The balanced two-string technique for sulcus intraocular lens implantation in the absence of capsular support. J Ophthalmol. 2015;2015:p153963.","journal-title":"J Ophthalmol"},{"issue":"6","key":"690_CR23","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.oret.2019.02.005","volume":"3","author":"BW Botsford","year":"2019","unstructured":"Botsford BW, et al. Scleral fixation of intraocular lenses with Gore-Tex suture: refractive outcomes and comparison of Lens power formulas. Ophthalmol Retina. 2019;3(6):468\u201372.","journal-title":"Ophthalmol Retina"},{"issue":"7","key":"690_CR24","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.oret.2019.02.012","volume":"3","author":"D Su","year":"2019","unstructured":"Su D, et al. Refractive outcomes after Pars plana vitrectomy and scleral fixated intraocular Lens with Gore-Tex suture. Ophthalmol Retina. 2019;3(7):548\u201352.","journal-title":"Ophthalmol Retina"},{"issue":"12","key":"690_CR25","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1097\/j.jcrs.0000000000000349","volume":"46","author":"J Goemaere","year":"2020","unstructured":"Goemaere J, et al. Fifteen years of IOL exchange: indications, outcomes, and complications. J Cataract Refract Surg. 2020;46(12):1596\u2013603.","journal-title":"J Cataract Refract Surg"}],"container-title":["International Journal of Retina and Vitreous"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00690-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40942-025-00690-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40942-025-00690-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T10:21:12Z","timestamp":1781605272000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s40942-025-00690-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,20]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["690"],"URL":"https:\/\/doi.org\/10.1186\/s40942-025-00690-5","relation":{},"ISSN":["2056-9920"],"issn-type":[{"value":"2056-9920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,20]]},"assertion":[{"value":"24 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Federal University of S\u00e3o Paulo institution\u2019s Research Ethics Committee reviewed and approved this study protocol (Approval Number, 4.261.258).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors have consented the publication of this paper.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"69"}}