{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T14:58:17Z","timestamp":1781362697174,"version":"3.54.1"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,26]],"date-time":"2021-04-26T00:00:00Z","timestamp":1619395200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,4,26]],"date-time":"2021-04-26T00:00:00Z","timestamp":1619395200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["JA Clin Rep"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The IMPELLA\u00ae is a minimally invasive left ventricular assist device. We report a case in which transesophageal echocardiography (TEE) was useful in diagnosis of left ventricular rupture after IMPELLA\u00ae insertion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 75-year-old man presented to the emergency room with chest pain and underwent percutaneous coronary intervention for 100% stenosis of the left anterior descending branch #7. An IMPELLA\u00ae was inserted to stabilize the circulation, but hypotension persisted. Transthoracic echocardiography revealed increased pericardial effusion and suspicion of free wall left ventricular rupture, leading to emergency surgery. TEE revealed the IMPELLA\u00ae straying into the left ventricle apical wall and cardiac tamponade. Hemorrhage was observed from the thinning free wall and the tip of the IMPELLA\u00ae was palpable. The IMPELLA\u00ae was removed and the left ventricular wall was repaired.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The IMPELLA\u00ae requires implantation of the tip in the left ventricle, but it should be noted that a fragile ventricular wall can be easily perforated.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40981-021-00444-w","type":"journal-article","created":{"date-parts":[[2021,4,26]],"date-time":"2021-04-26T14:04:22Z","timestamp":1619445862000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A case of left ventricular free wall rupture after insertion of an IMPELLA\u00ae left ventricular assist device diagnosed by transesophageal echocardiography"],"prefix":"10.1186","volume":"7","author":[{"given":"Akito","family":"Mizuno","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3172-0855","authenticated-orcid":false,"given":"Shuji","family":"Kawamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuji","family":"Uda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichiro","family":"Tatsumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chikashi","family":"Takeda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoharu","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiko","family":"Fukuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,26]]},"reference":[{"issue":"5","key":"444_CR1","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1161\/CIRCULATIONAHA.106.613596","volume":"117","author":"HR Reynolds","year":"2008","unstructured":"Reynolds HR, Hochman JS. Cardiogenic shock: current concepts and improving outcomes. Circulation. 2008;117(5):686\u201397. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.106.613596.","journal-title":"Circulation."},{"issue":"5","key":"444_CR2","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1002\/ccd.27329","volume":"91","author":"DC Peritz","year":"2018","unstructured":"Peritz DC, Linstroth L, Selzman CH, Gilbert EM. Left ventricular perforation after Impella\u00ae placement in a patient with cardiogenic shock. Catheter Cardiovasc Interv. 2018;91(5):894\u20136. https:\/\/doi.org\/10.1002\/ccd.27329.","journal-title":"Catheter Cardiovasc Interv."},{"issue":"03","key":"444_CR3","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1055\/s-0038-1666971","volume":"29","author":"JJ Glazier","year":"2018","unstructured":"Glazier JJ, Kaki A, Baciewicz F. Successful treatment of left ventricular perforation occurring after insertion of an Impella device. Int J Angiol. 2018;29(03):202\u20134. https:\/\/doi.org\/10.1055\/s-0038-1666971.","journal-title":"Int J Angiol."},{"key":"444_CR4","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.carrev.2019.06.011","volume":"21","author":"IA Salas de Armas","year":"2020","unstructured":"Salas de Armas IA, Kumar S, Almustafa A, Akkanti B, Akay MH, Patel MK, et al. Left ventricular rupture after Impella\u00ae placement during high risk percutaneous coronary intervention. Cardiovasc Revasc Med. 2020;21:100\u20132.","journal-title":"Cardiovasc Revasc Med"},{"issue":"17","key":"444_CR5","doi-asserted-by":"publisher","first-page":"2057","DOI":"10.1093\/eurheartj\/ehm191","volume":"28","author":"H Thiele","year":"2007","unstructured":"Thiele H, Smalling RW, Schuler GC. Percutaneous left ventricular assist devices in acute myocardial infarction complicated by cardiogenic shock. Eur Heart J. 2007;28(17):2057\u201363. https:\/\/doi.org\/10.1093\/eurheartj\/ehm191.","journal-title":"Eur Heart J."},{"issue":"3","key":"444_CR6","doi-asserted-by":"publisher","first-page":"248","DOI":"10.31486\/toj.18.0018","volume":"19","author":"A Kaki","year":"2019","unstructured":"Kaki A, Subahi A, Shokr M, Ibrahim W, Yassin A, Hasan R, et al. Impella-induced incessant ventricular tachycardia. Ochsner J. 2019;19(3):248\u201351. https:\/\/doi.org\/10.31486\/toj.18.0018.","journal-title":"Ochsner J."},{"issue":"10","key":"444_CR7","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1080\/17434440.2017.1374849","volume":"14","author":"N Nalluri","year":"2017","unstructured":"Nalluri N, Patel N, Saouma S, Anugu VR, Anugula D, Asti D, et al. Utilization of the Impella for hemodynamic support during percutaneous intervention and cardiogenic shock: an insight. Expert Rev Med Devices. 2017;14(10):789\u2013804. https:\/\/doi.org\/10.1080\/17434440.2017.1374849.","journal-title":"Expert Rev Med Devices."},{"key":"444_CR8","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1016\/j.ijcard.2015.07.065","volume":"201","author":"F Burzotta","year":"2015","unstructured":"Burzotta F, Trani C, Doshi SN, Townend J, van Geuns RJ, Hunziker P, et al. Impella ventricular support in clinical practice: collaborative viewpoint from a European expert user group. Int J Cardiol. 2015;201:684\u201391. https:\/\/doi.org\/10.1016\/j.ijcard.2015.07.065.","journal-title":"Int J Cardiol."},{"issue":"1","key":"444_CR9","doi-asserted-by":"publisher","first-page":"44","DOI":"10.4244\/EIJ-D-18-01021","volume":"15","author":"N Khalid","year":"2019","unstructured":"Khalid N, Rogers T, Shlofmitz E, Chen Y, Khan JM, Musallam A, et al. Adverse events and modes of failure related to the Impella percutaneous left ventricular assist devices: a retrospective analysis of the MAUDE database. EuroIntervention. 2019;15(1):44\u20136. https:\/\/doi.org\/10.4244\/EIJ-D-18-01021.","journal-title":"EuroIntervention."},{"key":"444_CR10","unstructured":"Impella device instructions for use product manual. ABIMED. https:\/\/www.abiomed.com\/impella-device-instructions-for-use. Accessed 4 Oct 2020."},{"key":"444_CR11","unstructured":"Kern MJ. Conversations in cardiology: the end of end-hole left ventriculography: a consensus of operators. 2013;21:11. https:\/\/www.cathlabdigest.com\/articles\/Conversations-Cardiology-End-End-hole-Left-Ventriculography-%E2%80%93-Consensus-Operators. Accessed 19 Dec 2020."}],"container-title":["JA Clinical Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-021-00444-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40981-021-00444-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-021-00444-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,2]],"date-time":"2021-06-02T15:11:50Z","timestamp":1622646710000},"score":1,"resource":{"primary":{"URL":"https:\/\/jaclinicalreports.springeropen.com\/articles\/10.1186\/s40981-021-00444-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,26]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["444"],"URL":"https:\/\/doi.org\/10.1186\/s40981-021-00444-w","relation":{},"ISSN":["2363-9024"],"issn-type":[{"value":"2363-9024","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,26]]},"assertion":[{"value":"25 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"In our hospital, publication of case reports is exempted from ethics committee approval.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent was obtained from the wife of the patient for publication of this case report.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"38"}}