{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T03:39:38Z","timestamp":1793417978765,"version":"4.5.0"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T00:00:00Z","timestamp":1657929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T00:00:00Z","timestamp":1657929600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["JA Clin Rep"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Thoracic endovascular aortic repair (TEVAR) has become a widely accepted treatment strategy for patients with thoracic aortic pathologies. We present a case of TEVAR where transesophageal echocardiography (TEE) played a crucial role for adequate placement of an endovascular stent graft.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 71-year-old male received TEVAR for type B aortic dissection. TEE detected both true\/false lumens with an intimal tear. A guidewire was inserted into the descending aorta via the left femoral artery; however, angiography failed to identify the precise location of the tip of the guidewire. TEE detected the guide wire passing through the intimal tear into the false lumen, promoted the surgeon to manipulate and advance it to the true lumen, followed by placement of a stent graft. The patient was hemodynamically stable through the whole procedure.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>TEE was crucially important for detecting the precise location of the guidewire and preventing complications during TEVAR.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40981-022-00539-y","type":"journal-article","created":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T02:02:19Z","timestamp":1657936939000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography"],"prefix":"10.1186","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1014-6866","authenticated-orcid":false,"given":"Mohamed","family":"Eissa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asadollah","family":"Mir-Ghassemi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudhir","family":"Nagpal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hesham F.","family":"Talab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,16]]},"reference":[{"issue":"5","key":"539_CR1","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1016\/j.jvs.2004.08.041","volume":"40","author":"G Rocchi","year":"2004","unstructured":"Rocchi G, Lofiego C, Biagini E, Piva T, Bracchetti G, Lovato L, et al. Transesophageal echocardiography-guided algorithm for stent-graft implantation in aortic dissection. J Vasc Surg. 2004;40(5):880\u20135.","journal-title":"J Vasc Surg"},{"issue":"1","key":"539_CR2","first-page":"67","volume":"17","author":"E Agricola","year":"2016","unstructured":"Agricola E, Slavich M, Rinaldi E, Bertoglio L, Civilini E, Melissano G, et al. Usefulness of contrast-enhanced transoesophageal echocardiography to guide thoracic endovascular aortic repair procedure. Eur Heart J Cardiovasc Imaging. 2016;17(1):67\u201375.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"539_CR3","first-page":"1071","volume":"38","author":"S Etheredge","year":"1955","unstructured":"Etheredge S, Yee J, Smith J, Schonberger S, Goldman M. Successful resection of a large aneurysm of the upper abdominal aorta and replacement with homograft. Surgery. 1955;38:1071\u201381.","journal-title":"Surgery"},{"key":"539_CR4","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1097\/00000658-195610000-00004","volume":"144","author":"ME DeBakey","year":"1956","unstructured":"DeBakey ME, Creech O, Morris GC. Aneurysm of thoracoabdominal aorta involving the celiac, superior mesenteric, and renal arteries; report of four cases treated by resection and homograft replacement. Ann Surg. 1956;144:549\u201373.","journal-title":"Ann Surg"},{"issue":"4","key":"539_CR5","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1053\/j.jvca.2017.03.022","volume":"31","author":"ACP Fort","year":"2017","unstructured":"Fort ACP, Rubin LA, Meltzer AJ, Schneider DB, Lichtman AD. Perioperative management of endovascular thoracoabdominal aortic aneurysm repair. J Cardiothorac Vasc Anesth. 2017;31(4):1440\u201359.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"4","key":"539_CR6","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1016\/j.jvscit.2019.07.011","volume":"5","author":"A Plotkin","year":"2019","unstructured":"Plotkin A, Hanks SE, Han SM, Fleischman F, Weaver FA, Magee GA. Endovascular septal fenestration using a radiofrequency wire to salvage inadvertent false lumen deployment of a frozen elephant trunk stent graft. J Vasc Surg Cases Innov Tech. 2019;5(4):553.","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"539_CR7","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.jvs.2014.11.072","volume":"63","author":"SM Han","year":"2016","unstructured":"Han SM, Gasper WJ, Chuter TA. Endovascular rescue after inadvertent false lumen stent graft implantation. J Vasc Surg. 2016;63:518\u201322.","journal-title":"J Vasc Surg"},{"issue":"4","key":"539_CR8","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1510\/icvts.2009.223040","volume":"10","author":"FM Follis","year":"2010","unstructured":"Follis FM, Filippone G, Stabile A, Montalbano G, Floriano M, Finazzo M, et al. Endovascular graft deployment in the false lumen of type B dissection. Interact Cardiovasc Thorac Surg. 2010;10(4):597\u20139.","journal-title":"Interact Cardiovasc Thorac Surg"}],"container-title":["JA Clinical Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-022-00539-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40981-022-00539-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-022-00539-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,16]],"date-time":"2022-07-16T02:04:13Z","timestamp":1657937053000},"score":1,"resource":{"primary":{"URL":"https:\/\/jaclinicalreports.springeropen.com\/articles\/10.1186\/s40981-022-00539-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,16]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["539"],"URL":"https:\/\/doi.org\/10.1186\/s40981-022-00539-y","relation":{},"ISSN":["2363-9024"],"issn-type":[{"value":"2363-9024","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,16]]},"assertion":[{"value":"26 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 June 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"None.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"50"}}