{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T02:52:39Z","timestamp":1789786359581,"version":"4.0.1"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T00:00:00Z","timestamp":1693958400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T00:00:00Z","timestamp":1693958400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["JA Clin Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Ultrasound-guided central venous catheterization has become a standard procedure. However, mechanical complications are still reported.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>An 85-year-old woman presented with coagulopathic bladder tamponade. Ultrasound-guided right internal jugular venous catheterization was planned because of difficult peripheral venous access. A guidewire was advanced through a needle inserted at the midpoint of the right carotid triangle. The guidewire was identified in the short axis, but not in the long-axis ultrasound view, leading to inadvertent insertion of the catheter into the right subclavian artery through the internal jugular vein. Stent graft insertion was performed for perforation closure. The patient exhibited no symptoms of cerebral ischemia following stent graft insertion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Discussion<\/jats:title>\n                <jats:p>This case demonstrated that the needle-sticking site should not be placed close to the clavicle for ultrasound-guided internal jugular venous catheterization, as it may not confirm the position of guidewire in the long-axis ultrasound view.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s40981-023-00649-1","type":"journal-article","created":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T08:02:34Z","timestamp":1693987354000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Inadvertent catheter misplacement into the subclavian artery during ultrasound-guided internal jugular venous catheterization: a case report"],"prefix":"10.1186","volume":"9","author":[{"given":"Tomoki","family":"Kohyama","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Fujimaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroki","family":"Sasamori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3481-2085","authenticated-orcid":false,"given":"Joho","family":"Tokumine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyoshi","family":"Moriyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoko","family":"Yorozu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,9,6]]},"reference":[{"issue":"1","key":"649_CR1","doi-asserted-by":"publisher","first-page":"CD006962","DOI":"10.1002\/14651858.CD006962.pub2","volume":"1","author":"P Brass","year":"2015","unstructured":"Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization. Cochrane Database Syst Rev. 2015;1(1):CD006962. https:\/\/doi.org\/10.1002\/14651858.CD006962.pub2.","journal-title":"Cochrane Database Syst Rev."},{"issue":"1","key":"649_CR2","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1111\/aas.13214","volume":"63","author":"M Bj\u00f6rkander","year":"2019","unstructured":"Bj\u00f6rkander M, Bentzer P, Sch\u00f6tt U, Broman ME, Kander T. Mechanical complications of central venous catheter insertions: a retrospective multicenter study of incidence and risks. Acta Anaesthesiol Scand. 2019;63(1):61\u20138. https:\/\/doi.org\/10.1111\/aas.13214.","journal-title":"Acta Anaesthesiol Scand"},{"issue":"2","key":"649_CR3","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s00540-019-02702-9","volume":"34","author":"Safety Committee of Japanese Society of Anesthesiologists","year":"2020","unstructured":"Safety Committee of Japanese Society of Anesthesiologists. Practical guide for safe central venous catheterization and management 2017. J Anesth. 2020;34(2):167\u201386. https:\/\/doi.org\/10.1007\/s00540-019-02702-9.","journal-title":"J Anesth"},{"issue":"10","key":"649_CR4","doi-asserted-by":"publisher","first-page":"2112","DOI":"10.1097\/CCM.0000000000001167","volume":"43","author":"YH Lee","year":"2015","unstructured":"Lee YH, Kim TK, Jung YS, Cho YJ, Yoon S, Seo JH, et al. Comparison of needle insertion and guidewire placement techniques during internal jugular vein catheterization: the thin-wall introducer needle technique versus the cannula-over-needle technique. Crit Care Med. 2015;43(10):2112\u20136. https:\/\/doi.org\/10.1097\/CCM.0000000000001167.","journal-title":"Crit Care Med"},{"issue":"8","key":"649_CR5","doi-asserted-by":"publisher","first-page":"2345","DOI":"10.1097\/CCM.0b013e3181a067d4","volume":"37","author":"M Blaivas","year":"2009","unstructured":"Blaivas M, Adhikari S. An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Crit Care Med. 2009;37(8):2345\u20139; quiz 2359.","journal-title":"Crit Care Med."},{"key":"649_CR6","doi-asserted-by":"publisher","unstructured":"American Society of Anesthesiologists Task Force on Central Venous Access, Practice Guidelines for Central Venous Access 2020: an updated report by the American Society of Anesthesiologists Task Force on Central Venous Access. Anesthesiology. 2020;132(1):8\u201343. https:\/\/doi.org\/10.1097\/ALN.0000000000002864.","DOI":"10.1097\/ALN.0000000000002864"},{"issue":"1","key":"649_CR7","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1186\/s13054-017-1814-y","volume":"21","author":"B Saugel","year":"2017","unstructured":"Saugel B, Scheeren TWL, Teboul JL. Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care. 2017;21(1):225. https:\/\/doi.org\/10.1186\/s13054-017-1814-y.","journal-title":"Crit Care"},{"issue":"1","key":"649_CR8","doi-asserted-by":"publisher","first-page":"24280","DOI":"10.1038\/s41598-021-03718-6","volume":"11","author":"R Wakabayashi","year":"2021","unstructured":"Wakabayashi R. Availability of ultrasound imaging of a guidewire parallel to the vein during internal jugular central venous catheter placement. Sci Rep. 2021;11(1):24280. https:\/\/doi.org\/10.1038\/s41598-021-03718-6.","journal-title":"Sci Rep"},{"key":"649_CR9","volume-title":"Percutaneous central venous and arterial catheterization","author":"IP Latto","year":"2000","unstructured":"Latto IP, Ng WS, Jones PL, Jenkins BJ. Percutaneous central venous and arterial catheterization. 3rd ed. London: Saunders Ltd.; 2000.","edition":"3"},{"issue":"1","key":"649_CR10","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1097\/00000542-199607000-00007","volume":"85","author":"CA Troianos","year":"1996","unstructured":"Troianos CA, Kuwik RJ, Pasqual JR, Lim AJ, Odasso DP. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anesthesiology. 1996;85(1):43\u20138. https:\/\/doi.org\/10.1097\/00000542-199607000-00007.","journal-title":"Anesthesiology"},{"key":"649_CR11","doi-asserted-by":"publisher","first-page":"110428","DOI":"10.1016\/j.jclinane.2021.110428","volume":"75","author":"O Nwokolo","year":"2021","unstructured":"Nwokolo O, Liang Y. Avoiding inadvertent subclavian artery puncture during central venous catheter placement. J Clin Anesth. 2021;75:110428. https:\/\/doi.org\/10.1016\/j.jclinane.2021.110428.","journal-title":"J Clin Anesth"},{"issue":"8","key":"649_CR12","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1016\/j.avsg.2015.05.030","volume":"29","author":"DY Yoon","year":"2015","unstructured":"Yoon DY, Annambhotla S, Resnick SA, Eskandari MK, Rodriguez HE. Inadvertent arterial placement of central venous catheters: diagnostic and therapeutic strategies. Ann Vasc Surg. 2015;29(8):1567\u201374. https:\/\/doi.org\/10.1016\/j.avsg.2015.05.030.","journal-title":"Ann Vasc Surg"}],"container-title":["JA Clinical Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-023-00649-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40981-023-00649-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-023-00649-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T19:17:05Z","timestamp":1700507825000},"score":1,"resource":{"primary":{"URL":"https:\/\/jaclinicalreports.springeropen.com\/articles\/10.1186\/s40981-023-00649-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,6]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["649"],"URL":"https:\/\/doi.org\/10.1186\/s40981-023-00649-1","relation":{},"ISSN":["2363-9024"],"issn-type":[{"value":"2363-9024","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,6]]},"assertion":[{"value":"3 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"J. T. is a technical adviser of the Cardinal Health K.K. (Japan) and has done an ultrasound-guided technical training course held by the company. The other authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"58"}}