{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T06:11:59Z","timestamp":1760595119359,"version":"build-2065373602"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["JA Clin Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Pulmonary artery catheter (PAC) entrapment is a rare but serious complication caused by inadvertent suturing to cardiac or vascular structures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Case presentation<\/jats:title>\n            <jats:p>A 42-year-old man underwent minimally invasive mitral valve repair via right mini-thoracotomy. Thirty minutes after weaning from cardiopulmonary bypass (CPB), pulmonary artery pressure suddenly dropped, and the waveform became identical to that of central venous pressure. Two centimeters of PAC mobility, aspiration of blood from the balloon port, and blood accumulation in the monitor connector were noted. On postoperative day 1, resistance was encountered during catheter withdrawal at 7\u00a0cm, and chest radiography revealed abnormal catheter curvature. Reoperation under CPB confirmed PAC entrapment at the left atriotomy suture line, and the catheter was successfully removed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>In minimally invasive mitral valve repair, a left atriotomy approach might be associated with a risk of PAC entrapment, and the option of not inserting a PAC should always be considered.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s40981-025-00822-8","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T05:34:45Z","timestamp":1760592885000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Postoperative detection of pulmonary artery catheter entrapment during minimally invasive mitral valve repair: a case report"],"prefix":"10.1186","volume":"11","author":[{"given":"Ayaka","family":"Higashi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sachiko","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0986-3446","authenticated-orcid":false,"given":"Atsushi","family":"Kainuma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshihito","family":"Mihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuya","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Matsuyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akiyuki","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Sakaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,16]]},"reference":[{"issue":"4","key":"822_CR1","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1053\/j.jvca.2024.12.044","volume":"39","author":"N Kumar","year":"2025","unstructured":"Kumar N, Toda C, Couture EJ, Vlahakes GJ, Fitzsimons MG. Entrapment of pulmonary artery catheters in cardiac surgery: a structured literature review and analysis of published case reports. J Cardiothorac Vasc Anesth. 2025;39(4):916\u201324.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"5","key":"822_CR2","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1111\/j.1540-8191.2000.tb00463.x","volume":"15","author":"M Kaplan","year":"2000","unstructured":"Kaplan M, Demirtas M, \u00c7imen S, et al. Swan-Ganz catheter entrapment in open heart surgery. J Card Surg. 2000;15(5):313\u20135.","journal-title":"J Card Surg"},{"issue":"1","key":"822_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.aat.2012.03.003","volume":"50","author":"WH Chan","year":"2012","unstructured":"Chan WH, Hsu CH, Lu CC, et al. Early recognition of an entrapped pulmonary artery catheter by blood leaking into the syringe and thermistor connector during cardiac surgery. Acta Anaesthesiol Taiwan. 2012;50(1):38\u201340.","journal-title":"Acta Anaesthesiol Taiwan"},{"issue":"1","key":"822_CR4","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/S1053-0770(99)90179-9","volume":"13","author":"R Kodavatiganti","year":"1999","unstructured":"Kodavatiganti R, Hearn CJ, Insler SR. Bleeding from a pulmonary artery catheter temperature connection port. J Cardiothorac Vasc Anesth. 1999;13(1):75\u20137.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"1","key":"822_CR5","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1053\/jcan.2003.31","volume":"17","author":"PE Dubois","year":"2003","unstructured":"Dubois PE, Collard E, X\u00e9nitos P, Louagie YAG. Early recognition of pulmonary artery catheter entrapment with TEE. J Cardiothorac Vasc Anesth. 2003;17(1):142\u20133.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"11","key":"822_CR6","doi-asserted-by":"publisher","first-page":"4198","DOI":"10.1053\/j.jvca.2022.06.020","volume":"36","author":"LS Gonzalez","year":"2022","unstructured":"Gonzalez LS, Coghlan C, Alsatli RA, et al. The entrapped pulmonary artery catheter. J Cardiothorac Vasc Anesth. 2022;36(11):4198\u2013207.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"4","key":"822_CR7","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1177\/145749690909800402","volume":"98","author":"DC Evans","year":"2009","unstructured":"Evans DC, Doraiswamy VA, Prosciak MP, et al. Complications associated with pulmonary artery catheters: a comprehensive clinical review. Scand J Surg. 2009;98(4):199\u2013208.","journal-title":"Scand J Surg"},{"issue":"10","key":"822_CR8","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1007\/BF03013136","volume":"46","author":"S Deneu","year":"1999","unstructured":"Deneu S, Coddens J, Deloof T. Catheter entrapment by atrial suture during minimally invasive port-access cardiac surgery. Can J Anaesth. 1999;46(10):983\u20136.","journal-title":"Can J Anaesth"},{"issue":"5","key":"822_CR9","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/S1053-0770(98)90103-3","volume":"12","author":"KF Koh","year":"1998","unstructured":"Koh KF, Chen FG. The irremovable swan: a complication of the pulmonary artery catheter. J Cardiothorac Vasc Anesth. 1998;12(5):561\u20132.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"2","key":"822_CR10","doi-asserted-by":"publisher","first-page":"114","DOI":"10.4103\/1658-354X.65125","volume":"4","author":"R Alsatli","year":"2010","unstructured":"Alsatli R. Pulmonary artery catheter entrapment in cardiac surgery. Saudi J Anaesth. 2010;4(2):114.","journal-title":"Saudi J Anaesth"},{"issue":"1","key":"822_CR11","doi-asserted-by":"publisher","first-page":"8","DOI":"10.4326\/jjcvs.50.8","volume":"50","author":"The Japanese Society for Cardiovascular Surgery","year":"2021","unstructured":"The Japanese Society for Cardiovascular Surgery. Consensus statement on pulmonary artery catheter use during cardiac surgery. Jpn J Cardiovasc Surg. 2021;50(1):8\u201314.","journal-title":"Jpn J Cardiovasc Surg"},{"issue":"1","key":"822_CR12","doi-asserted-by":"publisher","first-page":"110","DOI":"10.4103\/aca.aca_11_21","volume":"26","author":"Y Tachibana","year":"2023","unstructured":"Tachibana Y, Wu I, Obata Y, et al. Transesophageal echocardiographic diagnosis of pulmonary artery catheter entrapment caused by left atrial suture. Ann Card Anaesth. 2023;26(1):110\u20131.","journal-title":"Ann Card Anaesth"},{"issue":"3","key":"822_CR13","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1053\/j.jvca.2005.11.023","volume":"20","author":"E Jacobsohn","year":"2006","unstructured":"Jacobsohn E, Fessler DA, Rosemeier F, Tymkew H, Avidan M. Morbidity and mortality associated with accidentally entrapped pulmonary artery catheters during cardiac surgery: a case series. J Cardiothorac Vasc Anesth. 2006;20(3):371\u20135.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"5","key":"822_CR14","doi-asserted-by":"publisher","first-page":"490","DOI":"10.21037\/acs-2022-rmvs-21","volume":"11","author":"ML Williams","year":"2022","unstructured":"Williams ML, Hwang B, Huang L, et al. Robotic versus conventional sternotomy mitral valve surgery: a systematic review and meta-analysis. Ann Cardiothorac Surg. 2022;11(5):490\u2013503.","journal-title":"Ann Cardiothorac Surg"},{"issue":"11","key":"822_CR15","volume":"10","author":"D Aston","year":"2023","unstructured":"Aston D, Zeloof D, Falter F. Anaesthesia for minimally invasive cardiac surgery. J Cardiovasc Dev Dis. 2023;10(11):462.","journal-title":"J Cardiovasc Dev Dis"},{"issue":"6","key":"822_CR16","first-page":"818","volume":"2","author":"S Jacobs","year":"2013","unstructured":"Jacobs S, S\u00fcndermann SH. Minimally invasive valve sparing mitral valve repair-the loop technique-how we do it. Ann Cardiothorac Surg. 2013;2(6):818\u201324.","journal-title":"Ann Cardiothorac Surg"}],"container-title":["JA Clinical Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-025-00822-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s40981-025-00822-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s40981-025-00822-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T05:34:47Z","timestamp":1760592887000},"score":1,"resource":{"primary":{"URL":"https:\/\/jaclinicalreports.springeropen.com\/articles\/10.1186\/s40981-025-00822-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,16]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["822"],"URL":"https:\/\/doi.org\/10.1186\/s40981-025-00822-8","relation":{},"ISSN":["2363-9024"],"issn-type":[{"value":"2363-9024","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,16]]},"assertion":[{"value":"11 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"In our hospital, the publication of case reports is exempt from ethics committee approval.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent was obtained from the patient for publication of this case report.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"54"}}