{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T18:33:26Z","timestamp":1792175606982,"version":"4.4.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T00:00:00Z","timestamp":1596153600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T00:00:00Z","timestamp":1596153600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["3D Print Med"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Extracting and three-dimensional (3D) printing an organ in a region of interest in DICOM images typically calls for segmentation as a first step in support of 3D printing. The DICOM images are not exported to STL data immediately, but segmentation masks are exported to STL models. After primary and secondary processing, including noise removal and hole correction, the STL data can be 3D printed. The quality of the 3D model is directly related to the quality of the STL data. This study focuses and reports on the DICOM to STL segmentation performance for nine software packages.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Multidetector row CT scanning was performed on a dry human mandible with two 10-mm-diameter bearing balls as a phantom. The DICOM image file was then segmented and exported to an STL file using nine different commercial\/open-source software packages. Once the STL models were created, the data (file) properties and the size and volume of each file were measured, and differences across the software packages were noted. Additionally, to evaluate differences between the shapes of the STL models by software package, each pair of STL models was superimposed, with the observed differences between their shapes characterized as the shape error.<\/jats:p>\n                    <jats:p>Results: The data (file) size of the STL file and the number of triangles that constitute each STL model were different across all software packages, but no statistically significant differences were found across software packages. The created ball STL model expanded in the X-, Y-, and Z-axis directions, with the length in the Z-axis direction (body axis direction) being slightly longer than that in the other directions. The mean shape error between software packages of the mandibular STL model was 0.11\u2009mm, but there was no statistically significant difference between them.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our results revealed that there are some differences between the software packages that perform the segmentation and STL creation of the DICOM image data. In particular, the features of each software package appeared in the fine and thin areas of the osseous structures. When using these software packages, it is necessary to understand the characteristics of each.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41205-020-00069-2","type":"journal-article","created":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T06:04:11Z","timestamp":1596175451000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":81,"title":["DICOM segmentation and STL creation for 3D printing: a process and software package comparison for osseous anatomy"],"prefix":"10.1186","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2559-7443","authenticated-orcid":false,"given":"Takashi","family":"Kamio","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madoka","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rieko","family":"Asaumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taisuke","family":"Kawai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,7,31]]},"reference":[{"key":"69_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41205-019-0038-y","volume":"5","author":"E Kikano","year":"2019","unstructured":"Kikano E, Grosse Hokamp N, Ciancibello L, Ramaiya N, Kosmas C, Gupta A. Utility of virtual monoenergetic images from spectral detector computed tomography in improving image segmentation for purposes of 3D printing and modeling. 3D Print Med. 2019;5:1. https:\/\/doi.org\/10.1186\/s41205-019-0038-y.","journal-title":"3D Print Med"},{"key":"69_CR2","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s41205-018-0035-6","volume":"4","author":"T Punyaratabandhu","year":"2018","unstructured":"Punyaratabandhu T, Liacouras PC, Pairojboriboon S. Using 3D models in orthopedic oncology: presenting personalized advantages in surgical planning and intraoperative outcomes. 3D Print Med. 2018;4:12. https:\/\/doi.org\/10.1186\/s41205-018-0035-6.","journal-title":"3D Print Med"},{"key":"69_CR3","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1016\/j.jcms.2017.03.022","volume":"45","author":"RL Flores","year":"2017","unstructured":"Flores RL, Liss H, Raffaelli S, Humayun A, Khouri KS, Coelho PG, Witek L. The technique for 3D printing patient-specific models for auricular reconstruction. J Craniomaxillofac Surg. 2017;45:937\u201343. https:\/\/doi.org\/10.1016\/j.jcms.2017.03.022.","journal-title":"J Craniomaxillofac Surg"},{"key":"69_CR4","doi-asserted-by":"publisher","first-page":"1913","DOI":"10.1016\/j.jcms.2016.09.008","volume":"44","author":"J Suojanen","year":"2016","unstructured":"Suojanen J, Leikola J, Stoor P. The use of patient-specific implants in orthognathic surgery: a series of 32 maxillary osteotomy patients. J Craniomaxillofac Surg. 2016;44:1913\u20136. https:\/\/doi.org\/10.1016\/j.jcms.2016.09.008.","journal-title":"J Craniomaxillofac Surg"},{"key":"69_CR5","first-page":"22","volume":"1205","author":"K McHenry","year":"2008","unstructured":"McHenry K, Bajcsy P. An overview of 3D data content, file formats and viewers. Nat Center Supercomp Appl. 2008;1205:22 https:\/\/www.archives.gov\/files\/applied-research\/ncsa\/8-an-overview-of-3d-data-content-file-formats-and-viewers.pdf (Accessed 14 Dec 2019).","journal-title":"Nat Center Supercomp Appl"},{"key":"69_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41205-016-0005-9","volume":"2","author":"M Di Prima","year":"2016","unstructured":"Di Prima M, Coburn J, Hwang D, Kelly J, Khairuzzaman A, Ricles L. Additively manufactured medical products\u2013the FDA perspective. 3D Print Med. 2016;2:1\u20136. https:\/\/doi.org\/10.1186\/s41205-016-0005-9.","journal-title":"3D Print Med"},{"key":"69_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41205-016-0005-9","volume":"3","author":"A Christensen","year":"2017","unstructured":"Christensen A, Rybicki FJ. Maintaining safety and efficacy for 3D printing in medicine. 3D Print Med. 2017;3:1\u201310. https:\/\/doi.org\/10.1186\/s41205-016-0005-9.","journal-title":"3D Print Med"},{"key":"69_CR8","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s41205-018-0028-5","volume":"4","author":"T Kamio","year":"2018","unstructured":"Kamio T, Hayashi K, Onda T, Takaki T, Shibahara T, Yakushiji T, Shibui T, Kato H. Utilizing a low-cost desktop 3D printer to develop a \u201cone-stop 3D printing lab\u201d for oral and maxillofacial surgery and dentistry fields. 3D Print Med. 2018;4:6. https:\/\/doi.org\/10.1186\/s41205-018-0028-5.","journal-title":"3D Print Med"},{"key":"69_CR9","doi-asserted-by":"publisher","first-page":"034501","DOI":"10.1117\/1.JMI.4.3.034501","volume":"3","author":"N Aghdasi","year":"2017","unstructured":"Aghdasi N, Li Y, Berens AM, Harbison RA, Moe KS, Hannaford B. Efficient orbital structures segmentation with prior anatomical knowledge. J Med Imaging. 2017;3:034501. https:\/\/doi.org\/10.1117\/1.JMI.4.3.034501.","journal-title":"J Med Imaging"},{"key":"69_CR10","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.procir.2016.05.046","volume":"50","author":"S H\u00e4llgren","year":"2016","unstructured":"H\u00e4llgren S, Lars P, Jens E. 3D data export for additive manufacturing-improving geometric accuracy. Procedia Cirp. 2016;50:518\u201323. https:\/\/doi.org\/10.1016\/j.procir.2016.05.046.","journal-title":"Procedia Cirp"},{"key":"69_CR11","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1002\/acm2.12476","volume":"19","author":"C Anam","year":"2018","unstructured":"Anam C, Fujibuchi T, Budi WS, Haryanto F, Dougherty G. An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: impact of field of view on spatial resolution of CT image. J Appl Clin Med Phys. 2018;19:244\u201352. https:\/\/doi.org\/10.1002\/acm2.12476.","journal-title":"J Appl Clin Med Phys"},{"key":"69_CR12","first-page":"283","volume":"32","author":"S Tanimoto","year":"2012","unstructured":"Tanimoto S. Collaborative research on polygon engineering with RIKEN. Unisys Technol Rev. 2012;32:283\u201392 (in Japanese). http:\/\/www.unisys.co.jp\/tec_info\/tr114\/11413.pdf. (Accessed 14 Dec 2019).","journal-title":"Unisys Technol Rev"},{"key":"69_CR13","volume-title":"R: A language and environment for statistical computing","author":"R Core Team","year":"2019","unstructured":"R Core Team. R: A language and environment for statistical computing. Vienna: R Foundation for Statistical Computing; 2019. https:\/\/www.R-project.org\/ (Accessed 15 Dec 2019)."},{"key":"69_CR14","doi-asserted-by":"publisher","first-page":"39","DOI":"10.7166\/25-2-675","volume":"25","author":"AC Brown","year":"2014","unstructured":"Brown AC, De Beer D, Conradie P. Development of a stereolithography (STL) input and computer numerical control (CNC) output algorithm for an entry-level 3-D printer. S Afr J Ind Eng. 2014;25:39\u201347. https:\/\/doi.org\/10.7166\/25-2-675.","journal-title":"S Afr J Ind Eng"},{"key":"69_CR15","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1145\/37401.37422","volume":"21","author":"WE Lorensen","year":"1987","unstructured":"Lorensen WE, Cline HE. Marching cubes: a high resolution 3d surface construction algorithm. ACM Siggraph Comp Graph. 1987;21:163\u20139. https:\/\/doi.org\/10.1145\/37401.37422.","journal-title":"ACM Siggraph Comp Graph"},{"key":"69_CR16","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.11371\/iieej.37.1037","volume":"37","author":"A Doi","year":"2008","unstructured":"Doi A, Suzuki S, Yamasa F, Itoh F, Matsui K, Sachio M, Itoh S. Volume Extractor Ver.3.0 -3D Image Processing and 3D Model Re-construction. IIEE J. 2008;37:1037\u201343. https:\/\/doi.org\/10.11371\/iieej.37.1037.","journal-title":"IIEE J"},{"issue":"6","key":"69_CR17","doi-asserted-by":"publisher","first-page":"562","DOI":"10.3390\/e21060562","volume":"21","author":"M Hubert","year":"2019","unstructured":"Hubert M, Krzysztof O. Improvement of image binarization methods using image preprocessing with local entropy filtering for alphanumerical character recognition purposes. Entropy. 2019;21(6):562. https:\/\/doi.org\/10.3390\/e21060562.","journal-title":"Entropy"},{"key":"69_CR18","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1111\/ors.12228","volume":"10","author":"S Shepherd","year":"2017","unstructured":"Shepherd S, Macluskey M, Napier A, Jackson R. Oral surgery simulated teaching; 3D model printing. Oral Surg. 2017;10:80\u20135. https:\/\/doi.org\/10.1111\/ors.12228.","journal-title":"Oral Surg"},{"key":"69_CR19","doi-asserted-by":"publisher","first-page":"193","DOI":"10.2209\/tdcpublication.2018-0058","volume":"60","author":"T Kamio","year":"2019","unstructured":"Kamio T, Kato H. Autotransplantation of impacted third molar using 3D printing technology: a case report. Bull Tokyo Dent Coll. 2019;60:193\u20139. https:\/\/doi.org\/10.2209\/tdcpublication.2018-0058.","journal-title":"Bull Tokyo Dent Coll"},{"key":"69_CR20","doi-asserted-by":"publisher","first-page":"177","DOI":"10.2209\/tdcpublication.56.177","volume":"56","author":"H Kato","year":"2015","unstructured":"Kato H, Kamio T. Diagnosis and endodontic Management of Fused Mandibular Second Molar and Paramolar with Concrescent supernumerary tooth using cone-beam CT and 3-D printing technology: a case report. Bull Tokyo Dent Coll. 2015;56:177\u201384. https:\/\/doi.org\/10.2209\/tdcpublication.56.177.","journal-title":"Bull Tokyo Dent Coll"},{"key":"69_CR21","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/s001700050","volume":"15","author":"YH Chen","year":"1999","unstructured":"Chen YH, Ng CT, Wang YZ. Generation of an STL file from 3D measurement data with user-controlled data reduction. Int J Adv Manuf Technol. 1999;15:127\u201331. https:\/\/doi.org\/10.1007\/s001700050.","journal-title":"Int J Adv Manuf Technol"},{"key":"69_CR22","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1148\/rg.2015140320","volume":"35","author":"D Mitsouras","year":"2015","unstructured":"Mitsouras D, Liacouras P, Imanzadeh A, Giannopoulos AA, Cai T, Kumamaru KK, George E, Wake N, Caterson EJ, Pomahac B, Ho VB, Grant GT, Rybicki FJ. Medical 3D printing for the radiologist. Radiographics. 2015;35:1965\u201388. https:\/\/doi.org\/10.1148\/rg.2015140320.","journal-title":"Radiographics"},{"key":"69_CR23","first-page":"97","volume":"36","author":"S Tanimoto","year":"2016","unstructured":"Tanimoto S. Polygon Editing Functions for 3D-Printing. Unisys Technol Rev. 2016;36:97\u2013114 (in Japanese). https:\/\/www.unisys.co.jp\/tec_info\/tr129\/12905.pdf (Accessed 15 Feb 2020).","journal-title":"Unisys Technol Rev"},{"key":"69_CR24","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s41205-017-0014-3","volume":"3","author":"S Leng","year":"2017","unstructured":"Leng S, McGee K, Morris J, Alexander A, Kuhlmann J, Vrieze T, McCollough CH, Matsumoto J. Anatomic modeling using 3D printing: quality assurance and optimization. 3D Print Med. 2017;3:6. https:\/\/doi.org\/10.1186\/s41205-017-0014-3.","journal-title":"3D Print Med"},{"key":"69_CR25","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s41205","volume":"1","author":"T Cai","year":"2015","unstructured":"Cai T, Rybicki FJ, Giannopoulos AA, Schultz K, Kumamaru KK, Liacouras P, Demehri S, Shu Small KM, Mitsouras D. The residual STL volume as a metric to evaluate accuracy and reproducibility of anatomic models for 3D printing: application in the validation of 3D-printable models of maxillofacial bone from reduced radiation dose CT images. 3D Print Med. 2015;1:2. https:\/\/doi.org\/10.1186\/s41205.","journal-title":"3D Print Med"}],"container-title":["3D Printing in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-020-00069-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41205-020-00069-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-020-00069-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,30]],"date-time":"2021-07-30T21:11:20Z","timestamp":1627679480000},"score":1,"resource":{"primary":{"URL":"https:\/\/threedmedprint.biomedcentral.com\/articles\/10.1186\/s41205-020-00069-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,31]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["69"],"URL":"https:\/\/doi.org\/10.1186\/s41205-020-00069-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-16450\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-16450\/v3","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-16450\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-16450\/v4","asserted-by":"object"}]},"ISSN":["2365-6271"],"issn-type":[{"value":"2365-6271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,31]]},"assertion":[{"value":"2 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was reviewed and approved by the institutional review boards of the participating institutions.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"17"}}