{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T22:28:25Z","timestamp":1782944905875,"version":"3.54.5"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T00:00:00Z","timestamp":1628812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T00:00:00Z","timestamp":1628812800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100012940","name":"Universit\u00e4tsklinikum T\u00fcbingen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100012940","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["3D Print Med"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>During cardiogenic shock blood circulation is minimal in the human body and does not suffice to survive. The extracorporeal life support system (ECLS) acts as a miniature heart-lung-machine that can be temporarily implanted over major vessels e.g. at the groin of the patient to bridge cardiogenic shock. To perform this procedure in an emergency, a proper training model is desirable. Therefore, a 3-dimensional-printable (3D) material must be found that mimics large vessel needle penetration properties. A suitable test bench for material comparison is desirable.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A test setup was built, which simulated the clinically relevant wall tension in specimens. The principle was derived from an existing standardized needle penetration test. After design, the setup was fabricated by means of 3D printing and mounted onto an universal testing machine. For testing the setup, a 3D printable polymer with low Shore A hardness and porcine aorta were used. The evaluation was made by comparing the curves of the penetration force to the standardized test considering the expected differences.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>3D printing proved to be suitable for manufacturing the test setup, which finally was able to mimic wall tension as if under blood pressure and penetration angle. The force displacement diagrams showed the expected curves and allowed a conclusion to the mechanical properties of the materials. Although the materials forces deviated between the porcine aorta and the Agilus30 polymer, the graphs showed similar but still characteristic curves.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The test bench provided the expected results and was able to show the differences between the two materials. To improve the setup, limitations has been discussed and changes can be implemented without complications.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s41205-021-00110-y","type":"journal-article","created":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T09:02:53Z","timestamp":1628845373000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Needle penetration test - qualifying examination of 3D printable silicones for vascular models in surgical practice"],"prefix":"10.1186","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4313-3826","authenticated-orcid":false,"given":"Thore","family":"von Steuben","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Salewski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander B.","family":"Xepapadeas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moritz","family":"Mutschler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Spintzyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,8,13]]},"reference":[{"issue":"10","key":"110_CR1","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1016\/j.bjps.2019.06.030","volume":"72","author":"H Riedle","year":"2019","unstructured":"Riedle H, Burkhardt AE, Seitz V, Pachaly B, Reid RR, Lee JC, et al. Design and fabrication of a generic 3D-printed silicone unilateral cleft lip and palate model. J Plast Reconstr Aesthet Surg. 2019;72(10):1669\u201374. https:\/\/doi.org\/10.1016\/j.bjps.2019.06.030.","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"110_CR2","doi-asserted-by":"publisher","first-page":"2860","DOI":"10.1109\/EMBC.2019.8856888","volume":"2019","author":"H Riedle","year":"2019","unstructured":"Riedle H, Braunias K, Mukai B, Franke J. Experimental mechanical examination of artificial 3D printed and post processed vascular silicone models. Annu Int Conf IEEE Eng Med Biol Soc. 2019;2019:2860\u20136. https:\/\/doi.org\/10.1109\/EMBC.2019.8856888.","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"4","key":"110_CR3","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1053\/j.sempedsurg.2006.07.003","volume":"15","author":"SC Skinner","year":"2006","unstructured":"Skinner SC, Hirschl RB, Bartlett RH. Extracorporeal life support. Semin Pediatr Surg. 2006;15(4):242\u201350. https:\/\/doi.org\/10.1053\/j.sempedsurg.2006.07.003.","journal-title":"Semin Pediatr Surg"},{"issue":"suppl_434","key":"110_CR4","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1080\/02841850802133386","volume":"434","author":"SI Seldinger","year":"2008","unstructured":"Seldinger SI. Catheter replacement of the needle in percutaneous arteriography. A new technique Acta Radiol Suppl (Stockholm). 2008;434(suppl_434):47\u201352. https:\/\/doi.org\/10.1080\/02841850802133386.","journal-title":"A new technique Acta Radiol Suppl (Stockholm)"},{"issue":"4","key":"110_CR5","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.ejvs.2017.12.014","volume":"55","author":"HWL de Beaufort","year":"2018","unstructured":"de Beaufort HWL, Ferrara A, Conti M, Moll FL, van Herwaarden JA, Figueroa CA, et al. Comparative analysis of porcine and human thoracic aortic stiffness. Eur J Vasc Endovasc Surg. 2018;55(4):560\u20136. https:\/\/doi.org\/10.1016\/j.ejvs.2017.12.014.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"110_CR6","unstructured":"Stratasys Ltd. Agilus30. https:\/\/www.stratasys.com\/materials\/search\/agilus30. Accessed 16 Jan 2021"},{"key":"110_CR7","volume-title":"DIN ISO 11040-4 - Vorgef\u00fcllte Spritzen - Teil 4: Spritzenzylinder aus Glas f\u00fcr Injektionspr\u00e4parate und sterilisierte und vormontierte Spritzen zur Abf\u00fcllung (ISO 11040-4:2015)","author":"Deutsches Institut f\u00fcr Normung","year":"2007","unstructured":"Deutsches Institut f\u00fcr Normung. DIN ISO 11040-4 - Vorgef\u00fcllte Spritzen - Teil 4: Spritzenzylinder aus Glas f\u00fcr Injektionspr\u00e4parate und sterilisierte und vormontierte Spritzen zur Abf\u00fcllung (ISO 11040-4:2015). Deutsche Norm: Beuth Verlag GmbH, Berlin; 2007."},{"key":"110_CR8","unstructured":"ZwickRoell AllroundLine Z010 TN, 10 kN, retroLine testControl II. https:\/\/www.zwickroell.com\/en\/pre-owned-testing-machines\/1011962_zwickroell_z010_tn_10kn. Accessed 27 Aug 2019"},{"key":"110_CR9","unstructured":"Prusa Research a.s. Original Prusa i3 MK3S+ kit. https:\/\/shop.prusa3d.com\/en\/3d-printers\/180-original-prusa-i3-mk3s-kit.html?gclid=Cj0KCQjw4s7qBRCzARIsAImcAxZ1wNANTMGRRb1EkExHbN-Z7yPnO573YWCawQ6gzWOv5W-QZ0NHE9caAlc1EALw_wcB. Accessed 16 Jan 2021"},{"key":"110_CR10","unstructured":"Formlabs GmbH Technische Daten f\u00fcr Formlabs Stereolithografie 3D-Drucker. https:\/\/formlabs.com\/de\/3d-printers\/form-3\/tech-specs\/. Accessed 16 Jan 2021"},{"key":"110_CR11","first-page":"1","volume-title":"2018 11th biomedical engineering international conference (BMEiCON). IEEE, [place of publication not identified]","author":"H Riedle","year":"2018","unstructured":"Riedle H, Mukai B, Molz P, et al. Determination of the mechanical properties of aortic tissue for 3D printed surgical models. In: 2018 11th biomedical engineering international conference (BMEiCON). IEEE, [place of publication not identified]; 2018. p. 1\u20135."},{"key":"110_CR12","unstructured":"Javelin Technologies Inc. Stratasys J750 Digital Anatomy. https:\/\/www.javelin-tech.com\/3d\/stratasys-3d-printer\/stratasys-j750-digital-anatomy\/. Accessed 16 Jan 2021"},{"key":"110_CR13","volume-title":"DIN 7200 - Locheisen, Deutsche Fassung EN ISO 439:2020","author":"Deutsches Institut f\u00fcr Normung","year":"2014","unstructured":"Deutsches Institut f\u00fcr Normung. DIN 7200 - Locheisen, Deutsche Fassung EN ISO 439:2020. Beuth Verlag GmbH: Deutsche Norm; 2014."},{"key":"110_CR14","volume-title":"DIN EN 13480\u20133 - Metallische industrielle Rohrleitungen - Teil 3: Konstruktion und Berechnung; Deutsche Fassung EN 13480\u20133:2017","author":"Deutsches Institut f\u00fcr Normung","year":"2017","unstructured":"Deutsches Institut f\u00fcr Normung. DIN EN 13480\u20133 - Metallische industrielle Rohrleitungen - Teil 3: Konstruktion und Berechnung; Deutsche Fassung EN 13480\u20133:2017. Beuth Verlag GmbH: Deutsche Norm; 2017."},{"key":"110_CR15","doi-asserted-by":"publisher","DOI":"10.1177\/0267659120967194","volume-title":"ECMO implantation training: needle penetration in 3D printable materials and porcine aorta. Perfusion:267659120967194","author":"C Salewski","year":"2020","unstructured":"Salewski C, Spintzyk S, von Steuben T, Sandoval Boburg R, Nemeth A, Schille C, et al. ECMO implantation training: needle penetration in 3D printable materials and porcine aorta. Perfusion:267659120967194; 2020. https:\/\/doi.org\/10.1177\/0267659120967194. 026765912096719"},{"key":"110_CR16","unstructured":"Cook 2021. https:\/\/www.cookmedical.com\/interventional-radiology\/remembering-dr-sven-seldinger\/. Accessed 19 Apr 2021"},{"issue":"8","key":"110_CR17","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1111\/ceo.12963","volume":"45","author":"L Christensen","year":"2017","unstructured":"Christensen L, Cerda A, Olson JL. Real-time measurement of needle forces and acute pressure changes during intravitreal injections. Clin Exp Ophthalmol. 2017;45(8):820\u20137. https:\/\/doi.org\/10.1111\/ceo.12963.","journal-title":"Clin Exp Ophthalmol"},{"issue":"3","key":"110_CR18","doi-asserted-by":"publisher","first-page":"504e","DOI":"10.1097\/PRS.0000000000005321","volume":"143","author":"T Pavicic","year":"2019","unstructured":"Pavicic T, Webb KL, Frank K, Gotkin RH, Tamura B, Cotofana S. Arterial Wall penetration forces in needles versus cannulas. Plast Reconstr Surg. 2019;143(3):504e\u201312e. https:\/\/doi.org\/10.1097\/PRS.0000000000005321.","journal-title":"Plast Reconstr Surg"},{"key":"110_CR19","unstructured":"ZwickRoell Spritzenpr\u00fcfung nach DIN ISO 11040. https:\/\/www.zwickroell.com\/de-de\/medizin\/therapiesysteme\/spritzenpruefung-iso-11040. Accessed 16 Jan 2021"}],"container-title":["3D Printing in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-021-00110-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41205-021-00110-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-021-00110-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T09:20:14Z","timestamp":1628846414000},"score":1,"resource":{"primary":{"URL":"https:\/\/threedmedprint.biomedcentral.com\/articles\/10.1186\/s41205-021-00110-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,13]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["110"],"URL":"https:\/\/doi.org\/10.1186\/s41205-021-00110-y","relation":{},"ISSN":["2365-6271"],"issn-type":[{"value":"2365-6271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,13]]},"assertion":[{"value":"5 February 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21"}}