{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T06:59:39Z","timestamp":1793861979096,"version":"4.6.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T00:00:00Z","timestamp":1713916800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T00:00:00Z","timestamp":1713916800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["3D Print Med"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Surgical guides can improve the precision of implant placement and minimize procedural errors and their related complications. This study aims to determine how different disinfection and sterilization methods affect the size changes of drill guide templates and the mechanical properties of 3D-printed surgical guides made with LCD technology.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We produced a total of 100 samples. Forty surgical guides were fabricated to assess the implant drill guides\u2019 surface and geometric properties. We subjected sixty samples to mechanical tests to analyze their tensile, flexural, and compressive properties. We classified the samples into four groups based on each analytical method: GC, which served as the control group; GA, which underwent autoclave sterilization at 121\u00a0\u00b0C (+\u20091\u00a0bar, 20\u00a0min); GB, which underwent autoclave sterilization at 134\u00a0\u00b0C (+\u20092\u00a0bar, 10\u00a0min); and GL, which underwent disinfection with 70% isopropyl alcohol for 20\u00a0min.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Result<\/jats:title>\n                <jats:p>The results show that sterilization at 121\u00a0\u00b0C and 134\u00a0\u00b0C affects the mechanical and geometric characteristics of the surgical guides, while disinfection with 70% isopropyl alcohol gives better results.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Our study of 3D-printed surgical guides using LCD technology found that sterilization at high temperatures affects the guides\u2019 mechanical and geometric properties. Instead, disinfection with 70% isopropyl alcohol is recommended.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s41205-024-00214-1","type":"journal-article","created":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T05:02:14Z","timestamp":1713934934000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Effects of autoclaving and disinfection on 3D surgical guides using LCD technology for dental implant"],"prefix":"10.1186","volume":"10","author":[{"given":"Badreddine","family":"Labakoum","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr","family":"Farhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lhoucine Ben","family":"Taleb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azeddine","family":"Mouhsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aissam","family":"Lyazidi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,24]]},"reference":[{"key":"214_CR1","doi-asserted-by":"publisher","unstructured":"Guo T, Gulati K, Arora H, Han P, Fournier B, Ivanovski S. Orchestrating soft tissue integration at the transmucosal region of titanium implants. Acta Biomater Acta Mater Inc. 2021;33\u201349. https:\/\/doi.org\/10.1016\/j.actbio.2021.01.001","DOI":"10.1016\/j.actbio.2021.01.001"},{"key":"214_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/jre.12707","volume":"00","author":"ED de Avila","year":"2019","unstructured":"de Avila ED, van Oirschot BA, van den Beucken JJJP. Biomaterial-based possibilities for managing peri-implantitis. J Periodontal Res. 2019;00:1\u20139. https:\/\/doi.org\/10.1111\/jre.12707","journal-title":"J Periodontal Res"},{"key":"214_CR3","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1002\/j.0022-0337.2012.76.10.tb05389.x","volume":"76","author":"Z Jalbout","year":"2012","unstructured":"Jalbout Z, El Chaar E, Hirsch S. Dental Implant Placement by Predoctoral Dental students: a Pilot Program. J Dent Educ. 2012;76:1342\u20136.","journal-title":"J Dent Educ"},{"key":"214_CR4","doi-asserted-by":"publisher","first-page":"e484","DOI":"10.4317\/medoral.21741","volume":"22","author":"MA S\u00e1nchez-Garc\u00e9s","year":"2017","unstructured":"S\u00e1nchez-Garc\u00e9s MA, Ber\u00e1stegui-Jimeno E, Gay-Escoda C. Knowledge, aptitudes, and preferences in implant dentistry teaching\/training among undergraduate dental students at the University of Barcelona. Med Oral Patol Oral Cir Bucal. 2017;22:e484\u201390. https:\/\/doi.org\/10.4317\/medoral.21741","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"214_CR5","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1111\/eje.12076","volume":"18","author":"S Koole","year":"2014","unstructured":"Koole S, De Bruyn H. Contemporary undergraduate implant dentistry education: a systematic review. Eur J Dent Educ. 2014;18:11\u201323. https:\/\/doi.org\/10.1111\/eje.12076","journal-title":"Eur J Dent Educ"},{"key":"214_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.05.027","author":"M Yeung","year":"2019","unstructured":"Yeung M, Abdulmajeed A, Carrico CK, Deeb GR, Bencharit S. Accuracy and precision of 3D-printed implant surgical guides with different implant systems: an in vitro study. J Prosthet Dent. 2019. https:\/\/doi.org\/10.1016\/j.prosdent.2019.05.027","journal-title":"J Prosthet Dent"},{"key":"214_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2019.06.006","author":"T Kim","year":"2019","unstructured":"Kim T, Lee S, Kim GB, Hong D, Kwon J, Park J-W, et al. Accuracy of a simplified 3D-printed implant surgical guide. J Prosthet Dent. 2019. https:\/\/doi.org\/10.1016\/j.prosdent.2019.06.006","journal-title":"J Prosthet Dent"},{"key":"214_CR8","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1111\/clr.12638","volume":"26","author":"M Vercruyssen","year":"2015","unstructured":"Vercruyssen M, Laleman I, Jacobs R, Quirynen M. Computer-supported implant planning and guided surgery: a narrative review. Clin Oral Implants Res. 2015;26:69\u201376. https:\/\/doi.org\/10.1111\/clr.12638","journal-title":"Clin Oral Implants Res"},{"key":"214_CR9","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1016\/j.ajodo.2013.02.018","volume":"143","author":"MJ Bae","year":"2013","unstructured":"Bae MJ, Kim JY, Park JT, Cha JY, Kim HJ, Yu HS, et al. Accuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models. Am J Orthod Dentofac Orthop. 2013;143:893\u2013901. https:\/\/doi.org\/10.1016\/j.ajodo.2013.02.018","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"214_CR10","doi-asserted-by":"crossref","unstructured":"D\u2019haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontology 2000. 2017; pp. 121\u201333.","DOI":"10.1111\/prd.12175"},{"key":"214_CR11","doi-asserted-by":"publisher","unstructured":"Van Noort R. The future of dental devices is digital. Dental materials. Elsevier Inc.; 2012. pp. 3\u201312. https:\/\/doi.org\/10.1016\/j.dental.2011.10.014","DOI":"10.1016\/j.dental.2011.10.014"},{"key":"214_CR12","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1111\/prd.12164","volume":"73","author":"T Joda","year":"2017","unstructured":"Joda T, Ferrari M, Gallucci GO. Digital technology in fixed implant prosthodontics. Periodontol 2000. 2017;73:178\u201392.","journal-title":"Periodontol 2000"},{"key":"214_CR13","doi-asserted-by":"publisher","unstructured":"Rouz\u00e9 l\u2019Alzit F, Cade R, Naveau A, Babilotte J, Meglioli M, Catros S. Accuracy of commercial 3D printers for the fabrication of surgical guides in dental implantology. J Dent. 2022;117. https:\/\/doi.org\/10.1016\/j.jdent.2021.103909","DOI":"10.1016\/j.jdent.2021.103909"},{"key":"214_CR14","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1111\/jcpe.12897","volume":"45","author":"F Younes","year":"2018","unstructured":"Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontal. 2018;45:721\u201332. https:\/\/doi.org\/10.1111\/jcpe.12897","journal-title":"J Clin Periodontal"},{"key":"214_CR15","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1055\/s-0036-1584891","volume":"10","author":"D Karami","year":"2017","unstructured":"Karami D, Alborzinia HR, Amid R, Kadkhodazadeh M, Yousefi N, Badakhshan S. In-Office guided Implant Placement for Prosthetically Driven Implant surgery. Craniomaxillofac Trauma Reconstr. 2017;10:246\u201354. https:\/\/doi.org\/10.1055\/s-0036-1584891","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"214_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1136\/bjophthalmol-2013-304446","volume":"0","author":"C Schubert","year":"2013","unstructured":"Schubert C, Van Langeveld MC, Donoso LA. Innovations in 3D printing: a 3D overview from optics to organs. Br J Ophthalmol. 2013;0:1\u20133. https:\/\/doi.org\/10.1136\/bjophthalmol-2013-304446","journal-title":"Br J Ophthalmol"},{"key":"214_CR17","doi-asserted-by":"publisher","first-page":"1138","DOI":"10.3390\/pr8091138","volume":"8","author":"J Huang","year":"2020","unstructured":"Huang J, Qin Q, Wang J. A review of stereolithography: processes and systems. Processes MDPI. 2020;8:1138. https:\/\/doi.org\/10.3390\/pr8091138","journal-title":"Processes MDPI"},{"key":"214_CR18","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/j.prosdent.2016.10.017","volume":"118","author":"D Whitley","year":"2017","unstructured":"Whitley D, Eidson RS, Rudek I, Bencharit S. In-office fabrication of dental implant surgical guides using desktop stereolithographic printing and implant treatment planning software: a clinical report. J Prosthet Dent. 2017;118:256\u201363.","journal-title":"J Prosthet Dent"},{"key":"214_CR19","doi-asserted-by":"publisher","unstructured":"Zhao Z, Tian X, Song X. Engineering materials with light: recent progress in digital light processing based 3D printing. J Mater Chem C Mater Royal Soc Chem. 2020;13896\u2013917. https:\/\/doi.org\/10.1039\/d0tc03548c","DOI":"10.1039\/d0tc03548c"},{"key":"214_CR20","doi-asserted-by":"publisher","first-page":"2107","DOI":"10.3390\/polym14102107","volume":"14","author":"SI Pop","year":"2022","unstructured":"Pop SI, Dudescu M, Mihali SG, P\u0103curar M, Bratu DC. Effects of Disinfection and Steam sterilization on the Mechanical properties of 3D SLA-and DLP-Printed Surgical guides for Orthodontic Implant Placement. Polym (Basel). 2022;14:2107. https:\/\/doi.org\/10.3390\/polym14102107","journal-title":"Polym (Basel)"},{"key":"214_CR21","doi-asserted-by":"crossref","unstructured":"Revilla-Le\u00f3n M, P\u00e9rez-Barquero JA, Barmak BA, Agust\u00edn-Panadero R, Fern\u00e1ndez-Estevan L, Att W. Facial scanning accuracy depending on the alignment algorithm and digitized surface area location: an in vitro study. J Dent. 2021;110.","DOI":"10.1016\/j.jdent.2021.103680"},{"key":"214_CR22","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1097\/ID.0000000000000908","volume":"28","author":"HF Marei","year":"2019","unstructured":"Marei HF, Alshaia A, Alarifi S, Almasoud N, Abdelhady A. Effect of Steam Heat sterilization on the accuracy of 3D printed Surgical guides. Implant Dent. 2019;28:372\u20137. https:\/\/doi.org\/10.1097\/ID.0000000000000908","journal-title":"Implant Dent"},{"key":"214_CR23","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s12903-020-1005-0","volume":"20","author":"G T\u00f6r\u00f6k","year":"2020","unstructured":"T\u00f6r\u00f6k G, Gombocz P, Bogn\u00e1r E, Nagy P, Dinya E, Kisp\u00e9lyi B, et al. Effects of disinfection and sterilization on the dimensional changes and mechanical properties of 3D printed surgical guides for implant therapy - pilot study. BMC Oral Health. 2020;20:19. https:\/\/doi.org\/10.1186\/s12903-020-1005-0","journal-title":"BMC Oral Health"}],"container-title":["3D Printing in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-024-00214-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41205-024-00214-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-024-00214-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T05:06:15Z","timestamp":1713935175000},"score":1,"resource":{"primary":{"URL":"https:\/\/threedmedprint.biomedcentral.com\/articles\/10.1186\/s41205-024-00214-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,24]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["214"],"URL":"https:\/\/doi.org\/10.1186\/s41205-024-00214-1","relation":{},"ISSN":["2365-6271"],"issn-type":[{"value":"2365-6271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,24]]},"assertion":[{"value":"22 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests related to this work.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"14"}}