{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,11]],"date-time":"2026-10-11T03:35:42Z","timestamp":1791689742062,"version":"4.3.4"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T00:00:00Z","timestamp":1734480000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T00:00:00Z","timestamp":1734480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["3D Print Med"],"DOI":"10.1186\/s41205-024-00240-z","type":"journal-article","created":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T06:03:42Z","timestamp":1734501822000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["3D-printed patient-specific implants made of polylactide (PLDLLA) and \u03b2-tricalcium phosphate (\u03b2-TCP) for corrective osteotomies of the distal radius"],"prefix":"10.1186","volume":"10","author":[{"given":"Adam","family":"Jakimiuk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michaela","family":"Maintz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magdalena","family":"M\u00fcller-Gerbl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian Markus","family":"Thieringer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Keller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alissa","family":"Guebeli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Honigmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,18]]},"reference":[{"key":"240_CR1","doi-asserted-by":"publisher","unstructured":"Bushnell BD, Bynum DK. Malunion of the distal Radius. J Am Acad Orthop Surg. Jan. 2007;15(1):27\u201340. https:\/\/doi.org\/10.5435\/00124635-200701000-00004.","DOI":"10.5435\/00124635-200701000-00004"},{"key":"240_CR2","doi-asserted-by":"publisher","unstructured":"Pogue DJ, et al. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg Am. Sep. 1990;15(5):721\u20137. https:\/\/doi.org\/10.1016\/0363-5023(90)90143-F.","DOI":"10.1016\/0363-5023(90)90143-F"},{"key":"240_CR3","doi-asserted-by":"publisher","unstructured":"Liporace FA, Adams MR, Capo JT, Koval KJ. Distal Radius fractures. J Orthop Trauma. Nov. 2009;23(10):739\u201348. https:\/\/doi.org\/10.1097\/BOT.0b013e3181ba46d3.","DOI":"10.1097\/BOT.0b013e3181ba46d3"},{"key":"240_CR4","doi-asserted-by":"publisher","unstructured":"Katt B, Seigerman D, Lutsky K, Beredjiklian P. Distal Radius Malunion. J Hand Surg Am. May 2020;45(5):433\u201342. https:\/\/doi.org\/10.1016\/j.jhsa.2020.02.008.","DOI":"10.1016\/j.jhsa.2020.02.008"},{"key":"240_CR5","doi-asserted-by":"publisher","unstructured":"Hanawa T. Titanium\u2013tissue interface reaction and its control with Surface Treatment. Front Bioeng Biotechnol. Jul. 2019;7. https:\/\/doi.org\/10.3389\/fbioe.2019.00170.","DOI":"10.3389\/fbioe.2019.00170"},{"key":"240_CR6","doi-asserted-by":"publisher","unstructured":"Bell RB, Kindsfater CS. The Use of Biodegradable plates and screws to stabilize facial fractures. J Oral Maxillofac Surg. Jan. 2006;64(1):31\u20139. https:\/\/doi.org\/10.1016\/j.joms.2005.09.010.","DOI":"10.1016\/j.joms.2005.09.010"},{"key":"240_CR7","unstructured":"M\u00fcller K, Valentine-Thon E. Hypersensitivity to titanium: clinical and laboratory evidence. Neuro Endocrinol Lett. Dec. 2006;27(Suppl 1):31\u20135. Erratum in: Neuro Endocrinol Lett. Oct. 2007;28(5):iii. PMID: 17261997."},{"issue":"3","key":"240_CR8","doi-asserted-by":"publisher","first-page":"319","DOI":"10.4103\/0019-5413.41856","volume":"42","author":"M Dhillon","year":"2008","unstructured":"Dhillon M, Prabhakar S, Prasanna C. Preliminary experience with biodegradable implants for fracture fixation. Indian J Orthop. 2008;42(3):319. https:\/\/doi.org\/10.4103\/0019-5413.41856.","journal-title":"Indian J Orthop"},{"key":"240_CR9","doi-asserted-by":"publisher","unstructured":"Kumar AV, Staffenberg DA, Petronio JA, Wood RJ. Bioabsorbable Plates and Screws in Pediatric Craniofacial Surgery, Journal of Craniofacial Surgery, vol. 8, no. 2, pp. 97\u201399, Mar. 1997, https:\/\/doi.org\/10.1097\/00001665-199703000-00006","DOI":"10.1097\/00001665-199703000-00006"},{"key":"240_CR10","doi-asserted-by":"publisher","unstructured":"Turvey TA, Bell RB, Phillips C, Proffit WR. Self-Reinforced Biodegradable Screw Fixation Compared With Titanium Screw Fixation in Mandibular Advancement, Journal of Oral and Maxillofacial Surgery, vol. 64, no. 1, pp. 40\u201346, Jan. 2006, https:\/\/doi.org\/10.1016\/j.joms.2005.09.011","DOI":"10.1016\/j.joms.2005.09.011"},{"key":"240_CR11","doi-asserted-by":"publisher","unstructured":"Di Maggio B, et al. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up. Injury. Oct. 2017;48:S34\u20138. https:\/\/doi.org\/10.1016\/S0020-1383(17)30655-1.","DOI":"10.1016\/S0020-1383(17)30655-1"},{"key":"240_CR12","doi-asserted-by":"publisher","unstructured":"Toda E et al. Jan., Feasibility of Application of the Newly Developed Nano-Biomaterial, \u03b2-TCP\/PDLLA, in Maxillofacial Reconstructive Surgery: A Pilot Rat Study, Nanomaterials, vol. 11, no. 2, p. 303, 2021, https:\/\/doi.org\/10.3390\/nano11020303","DOI":"10.3390\/nano11020303"},{"key":"240_CR13","doi-asserted-by":"publisher","unstructured":"Berman B. 3-D printing: The new industrial revolution, Bus Horiz, vol. 55, no. 2, pp. 155\u2013162, Mar. 2012, https:\/\/doi.org\/10.1016\/j.bushor.2011.11.003","DOI":"10.1016\/j.bushor.2011.11.003"},{"key":"240_CR14","doi-asserted-by":"publisher","unstructured":"Zhang R et al. Jul., Open-Wedge HTO with Absorbable \u03b2-TCP\/PLGA Spacer Implantation and Proximal Fibular Osteotomy for Medial Compartmental Knee Osteoarthritis: New Technique Presentation, Journal of Investigative Surgery, vol. 34, no. 6, pp. 653\u2013661, 2021, https:\/\/doi.org\/10.1080\/08941939.2019.1670296","DOI":"10.1080\/08941939.2019.1670296"},{"key":"240_CR15","doi-asserted-by":"publisher","unstructured":"Deng X, et al. Changes in patellar height and posterior tibial slope angle following uniplanar medial opening wedge high tibial osteotomy using a novel wedge-shaped spacer implanation concurrent with proximal partial fibulectomy. Int Orthop. Jan. 2021;45(1):109\u201315. https:\/\/doi.org\/10.1007\/s00264-020-04786-5.","DOI":"10.1007\/s00264-020-04786-5"},{"key":"240_CR16","doi-asserted-by":"publisher","unstructured":"Baumbach SF, et al. Assessment of a novel biomechanical fracture model for distal radius fractures. BMC Musculoskelet Disord. Dec. 2012;13(1):252. https:\/\/doi.org\/10.1186\/1471-2474-13-252.","DOI":"10.1186\/1471-2474-13-252"},{"key":"240_CR17","doi-asserted-by":"publisher","first-page":"2677","DOI":"10.3390\/polym12112677","volume":"12","author":"L Hentschel","year":"2020","unstructured":"Hentschel L, Kynast F, Petersmann S, Holzer C, Gonzalez-Gutierrez J. Processing conditions of a medical Grade Poly(Methyl Methacrylate) with the Arburg Plastic Freeforming Additive Manufacturing process. Polym (Basel). 2020;12:2677. https:\/\/doi.org\/10.3390\/polym12112677.","journal-title":"Polym (Basel)"},{"key":"240_CR18","doi-asserted-by":"publisher","unstructured":"Engler LG, Crespo JS, Gately NM, Major I, Devine DM. Process optimization for the 3D Printing of PLA and HNT composites with Arburg Plastic Freeforming. J Compos Sci. Oct. 2022;6(10). https:\/\/doi.org\/10.3390\/jcs6100309.","DOI":"10.3390\/jcs6100309"},{"key":"240_CR19","doi-asserted-by":"publisher","unstructured":"Bayart M et al. Aug., Pellet-Based Fused Filament Fabrication (FFF)-Derived Process for the Development of Polylactic Acid\/Hydroxyapatite Scaffolds Dedicated to Bone Regeneration, Materials, vol. 15, no. 16, 2022, https:\/\/doi.org\/10.3390\/ma15165615","DOI":"10.3390\/ma15165615"},{"key":"240_CR20","doi-asserted-by":"publisher","unstructured":"Hukins DWL, Mahomed A, Kukureka SN. Accelerated aging for testing polymeric biomaterials and medical devices, Med Eng Phys, vol. 30, no. 10, pp. 1270\u20131274, Dec. 2008, https:\/\/doi.org\/10.1016\/j.medengphy.2008.06.001","DOI":"10.1016\/j.medengphy.2008.06.001"},{"key":"240_CR21","unstructured":"Evonik N. & Care GmbH, RESOMER\u00ae Composite LR 706 S \u00df-TCP Technical Data Sheet. 2019."},{"key":"240_CR22","doi-asserted-by":"publisher","unstructured":"Kozakiewicz M. Change in Pull-Out Force during resorption of Magnesium Compression screws for Osteosynthesis of Mandibular Condylar fractures. Materials. Jan. 2021;14(2):237. https:\/\/doi.org\/10.3390\/ma14020237.","DOI":"10.3390\/ma14020237"},{"key":"240_CR23","doi-asserted-by":"publisher","unstructured":"DeGoede KM, Ashton-Miller JA. Fall arrest strategy affects peak hand impact force in a forward fall, J Biomech, vol. 35, no. 6, pp. 843\u2013848, Jun. 2002, https:\/\/doi.org\/10.1016\/S0021-9290(02)00011-8","DOI":"10.1016\/S0021-9290(02)00011-8"},{"key":"240_CR24","doi-asserted-by":"crossref","unstructured":"Lin F-H, Chen -Mo, Lin -Pin, Lee J. The Merit of Sintered PDLLA\/TCP composites in Management of Bone Fracture Internal fixation. Blackwell Science, Inc; 1999.","DOI":"10.1046\/j.1525-1594.1999.06164.x"},{"key":"240_CR25","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1007\/978-3-319-89542-0_13","volume-title":"Orthopedic Biomaterials: Progress in Biology, Manufacturing, and industry perspectives","author":"B Prabhu","year":"2018","unstructured":"Prabhu B, Karau A, Wood A, Dadsetan M, Liedtke H, DeWitt T. Bioresorbable materials for Orthopedic Applications (Lactide and Glycolide Based). In: Li B, Webster T, editors. in Orthopedic Biomaterials: Progress in Biology, Manufacturing, and industry perspectives. Cham: Springer International Publishing; 2018. pp. 287\u2013344. https:\/\/doi.org\/10.1007\/978-3-319-89542-0_13."},{"key":"240_CR26","doi-asserted-by":"publisher","unstructured":"Smit TH, Krijnen MR, van Dijk M, Wuisman PIJM. Application of polylactides in spinal cages: Studies in a goat model, J Mater Sci Mater Med, vol. 17, no. 12, pp. 1237\u20131244, Dec. 2006, https:\/\/doi.org\/10.1007\/s10856-006-0597-5","DOI":"10.1007\/s10856-006-0597-5"},{"key":"240_CR27","doi-asserted-by":"publisher","unstructured":"Narayanan G, Vernekar VN, Kuyinu EL, Laurencin CT. Poly (lactic acid)-based biomaterials for orthopaedic regenerative engineering. Adv Drug Deliv Rev. Dec. 2016;107:247\u201376. https:\/\/doi.org\/10.1016\/j.addr.2016.04.015.","DOI":"10.1016\/j.addr.2016.04.015"},{"key":"240_CR28","doi-asserted-by":"publisher","unstructured":"Barth J, Akritopoulos P, Graveleau N, Barthelemy R, Toanen C, Saffarini M. Efficacy of Osteoconductive Ceramics in Bioresorbable screws for Anterior Cruciate Ligament Reconstruction. Orthop J Sports Med. May 2016;4(5):232596711664772. https:\/\/doi.org\/10.1177\/2325967116647724.","DOI":"10.1177\/2325967116647724"},{"key":"240_CR29","doi-asserted-by":"publisher","unstructured":"Matthews M, et al. Long-term outcomes of corrective osteotomies using porous Titanium wedges for flexible flatfoot deformity correction. J Foot Ankle Surg. Sep. 2018;57(5):924\u201330. https:\/\/doi.org\/10.1053\/j.jfas.2018.03.015.","DOI":"10.1053\/j.jfas.2018.03.015"},{"key":"240_CR30","doi-asserted-by":"publisher","unstructured":"Bohner M, Santoni BLG, D\u00f6belin N. \u03b2-tricalcium phosphate for bone substitution: synthesis and properties. Acta Biomater. Sep. 2020;113:23\u201341. https:\/\/doi.org\/10.1016\/j.actbio.2020.06.022.","DOI":"10.1016\/j.actbio.2020.06.022"},{"key":"240_CR31","unstructured":"Medartis AG. Distales Radius-System 2.5, APTUS wrist. Basel, 2018."}],"container-title":["3D Printing in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-024-00240-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41205-024-00240-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-024-00240-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T07:18:18Z","timestamp":1734506298000},"score":1,"resource":{"primary":{"URL":"https:\/\/threedmedprint.biomedcentral.com\/articles\/10.1186\/s41205-024-00240-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,18]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["240"],"URL":"https:\/\/doi.org\/10.1186\/s41205-024-00240-z","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4145453\/v1","asserted-by":"object"}]},"ISSN":["2365-6271"],"issn-type":[{"value":"2365-6271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,18]]},"assertion":[{"value":"21 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All cadavers\/involved human material met the requirements for consent according to Art. 36 HFG. In addition, the Ethical Commission of Northwestern Switzerland has reviewed the documents of our project (EKNZ AO_2023-00058) and confirmed that it fulfils the general ethical and scientific standards for research with humans.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Part of or the entire set of findings have been presented during the master defense of Adam Jakimiuk.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Further disclosure"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42"}}