{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T00:52:11Z","timestamp":1793407931251,"version":"4.5.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T00:00:00Z","timestamp":1782345600000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008375","name":"University of Basel","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008375","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["3D Print Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Native polyetheretherketone (PEEK) exhibits limitations in mechanical strength, radiographic visibility, and bioactivity for craniomaxillofacial (CMF) applications. This proof-of-concept study establishes the feasibility of point-of-care (POC) manufacturing for three functionalized PEEK composites for patient-specific CMF implants using a high-temperature material extrusion (MEX) system, with application-specific material selection to overcome these limitations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Carbon fiber-reinforced PEEK (CFR-PEEK), barium sulfate-filled PEEK (BaSO\u2084-PEEK), and biphasic calcium phosphate-filled PEEK (BCP-PEEK) were fabricated into patient-specific mandibular reconstruction plates, orbital floor implants, and chin augmentation implants, respectively. Manufacturing success rates, dimensional accuracy via root mean square (RMS) deviation analysis, post-sterilization dimensional stability, and layer adhesion quality were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Fabrication success rates of 100% (CFR-PEEK), 100% (BaSO\u2084-PEEK), and 85.7% (BCP-PEEK) were achieved. Dimensional accuracy analysis revealed RMS deviations of 0.16\u20130.29\u00a0mm between 3D-printed implants and original designs, within clinically acceptable ranges. Post-sterilization dimensional changes were minimal (RMS 0.05\u20130.07\u00a0mm). Complete layer adhesion was demonstrated across all materials, with no delamination or cracking observed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>These findings establish the manufacturing viability of POC fabrication of application-matched PEEK composites for patient-specific CMF implants, enhancing mechanical, radiographic, and bioactive properties whilst maintaining geometric customization.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41205-026-00331-z","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T06:25:24Z","timestamp":1782282324000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants"],"prefix":"10.1186","volume":"12","author":[{"given":"Jokin Zubizarreta","family":"Oteiza","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yannick","family":"Krieger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Seiler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian M.","family":"Thieringer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neha","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"331_CR1","doi-asserted-by":"publisher","first-page":"1968","DOI":"10.3390\/polym17141968","volume":"17","author":"S Dallal","year":"2025","unstructured":"Dallal S, Eslami B, Tiari S. Recent advances in PEEK for biomedical applications: a comprehensive review of material properties, processing, and additive manufacturing. Polym (Basel). 2025;17:1968. https:\/\/doi.org\/10.3390\/polym17141968.","journal-title":"Polym (Basel)"},{"key":"331_CR2","doi-asserted-by":"publisher","first-page":"373","DOI":"10.3390\/polym15020373","volume":"15","author":"MR Senra","year":"2023","unstructured":"Senra MR, Marques MFV, Monteiro SN. Poly (ether-ether-ketone) for biomedical applications: from enhancing bioactivity to reinforced-bioactive composites\u2014an overview. Polym (Basel). 2023;15:373. https:\/\/doi.org\/10.3390\/polym15020373.","journal-title":"Polym (Basel)"},{"key":"331_CR3","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1080\/15583724.2024.2406965","volume":"65","author":"J Molinar-D\u00edaz","year":"2025","unstructured":"Molinar-D\u00edaz J, Parsons AJ, Ahmed I, Warrior NA, Harper LT. Poly-ether-ether-ketone (PEEK) biomaterials and composites: challenges, progress, and opportunities. Polym Rev. 2025;65:527\u201365. https:\/\/doi.org\/10.1080\/15583724.2024.2406965.","journal-title":"Polym Rev"},{"key":"331_CR4","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1007\/s10856-016-5731-4","volume":"27","author":"IV Panayotov","year":"2016","unstructured":"Panayotov IV, Orti V, Cuisinier F, Yachouh J. Polyetheretherketone (PEEK) for medical applications. J Mater Sci Mater Med. 2016;27:118. https:\/\/doi.org\/10.1007\/s10856-016-5731-4.","journal-title":"J Mater Sci Mater Med"},{"key":"331_CR5","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007;28:4845\u201369. https:\/\/doi.org\/10.1016\/j.biomaterials.2007.07.013.","journal-title":"Biomaterials"},{"key":"331_CR6","doi-asserted-by":"publisher","first-page":"996","DOI":"10.3390\/polym17070996","volume":"17","author":"H Akhdar","year":"2025","unstructured":"Akhdar H. Theoretical investigation of photon interaction and X-ray imaging performance of PEEK-based composites for medical implants. Polymers. 2025;17:996. https:\/\/doi.org\/10.3390\/polym17070996.","journal-title":"Polymers"},{"key":"331_CR7","doi-asserted-by":"publisher","first-page":"619","DOI":"10.3390\/biomimetics10090619","volume":"10","author":"N Polat Sa\u011fs\u00f6z","year":"2025","unstructured":"Polat Sa\u011fs\u00f6z N, Murat F, Sevin\u00e7 G\u00fcl SN, \u015eensoy AT, Kaymaz I. CF-PEEK vs. titanium dental implants: stress distribution and fatigue performance in variable bone qualities. Biomimetics (Basel). 2025;10:619. https:\/\/doi.org\/10.3390\/biomimetics10090619.","journal-title":"Biomimetics (Basel)"},{"key":"331_CR8","doi-asserted-by":"publisher","first-page":"464","DOI":"10.3390\/biom13030464","volume":"13","author":"JR Dondani","year":"2023","unstructured":"Dondani JR, Iyer J, Tran SD. Surface treatments of PEEK for osseointegration to bone. Biomolecules. 2023;13:464. https:\/\/doi.org\/10.3390\/biom13030464.","journal-title":"Biomolecules"},{"key":"331_CR9","doi-asserted-by":"publisher","first-page":"100748","DOI":"10.1016\/j.mtbio.2023.100748","volume":"22","author":"Z Zhang","year":"2023","unstructured":"Zhang Z, Zhang X, Zheng Z, Xin J, Han S, Qi J, Zhang T, Wang Y, Zhang S. Latest advances: improving the anti-inflammatory and immunomodulatory properties of PEEK materials. Mater Today Bio. 2023;22:100748. https:\/\/doi.org\/10.1016\/j.mtbio.2023.100748.","journal-title":"Mater Today Bio"},{"key":"331_CR10","doi-asserted-by":"publisher","first-page":"872","DOI":"10.3390\/bioengineering10070872","volume":"10","author":"R Ghermandi","year":"2023","unstructured":"Ghermandi R, Tosini G, Lorenzi A, Griffoni C, La Barbera L, Girolami M, Pipola V, Brodano B, Bandiera G, Terzi S, Tedesco S, Evangelisti G, Monetta G, Noli A, Falzetti LE, Gasbarrini L, A. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) instrumentation in degenerative disease of lumbar spine: a pilot study. Bioeng (Basel). 2023;10:872. https:\/\/doi.org\/10.3390\/bioengineering10070872.","journal-title":"Bioeng (Basel)"},{"key":"331_CR11","doi-asserted-by":"publisher","first-page":"105974","DOI":"10.1016\/j.jmbbm.2023.105974","volume":"145","author":"S Arevalo","year":"2023","unstructured":"Arevalo S, Arthurs C, Molina MIE, Pruitt L, Roy A. An overview of the tribological and mechanical properties of PEEK and CFR-PEEK for use in total joint replacements. J Mech Behav Biomed Mater. 2023;145:105974. https:\/\/doi.org\/10.1016\/j.jmbbm.2023.105974.","journal-title":"J Mech Behav Biomed Mater"},{"key":"331_CR12","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1021\/acsbiomaterials.3c01667","volume":"10","author":"CK Emonde","year":"2024","unstructured":"Emonde CK, Eggers ME, Wichmann M, Hurschler C, Ettinger M, Denkena B. Radiopacity enhancements in polymeric implant biomaterials: a comprehensive literature review. ACS Biomater Sci Eng. 2024;10:1323\u201334. https:\/\/doi.org\/10.1021\/acsbiomaterials.3c01667.","journal-title":"ACS Biomater Sci Eng"},{"key":"331_CR13","doi-asserted-by":"publisher","unstructured":"Battistelli M, Mazzucchi E, Muselli M, Galieri G, Polli FM, Pignotti F, Olivi A, Sabatino G, La Rocca G. Safety and efficacy of zero-profile polyetheretherketone (PEEK) cages filled with biphasic calcium phosphate (BCP) in anterior cervical discectomy and fusion (ACDF): a case series. J Clin Med. 2024;13(1919). https:\/\/doi.org\/10.3390\/jcm13071919.","DOI":"10.3390\/jcm13071919"},{"key":"331_CR14","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1111\/j.1757-7861.2012.00185.x","volume":"4","author":"RJ Mobbs","year":"2012","unstructured":"Mobbs RJ, Chau AM, Durmush D. Biphasic calcium phosphate contained within a polyetheretherketone cage with and without plating for anterior cervical discectomy and fusion. Orthop Surg. 2012;4:156\u201365. https:\/\/doi.org\/10.1111\/j.1757-7861.2012.00185.x.","journal-title":"Orthop Surg"},{"key":"331_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18416\/AMMM.2020.2009011","volume":"2","author":"N Sharma","year":"2020","unstructured":"Sharma N, Honigmann P, Cao S, Thieringer F. Dimensional characteristics of FDM 3D printed PEEK implant for craniofacial reconstructions. Trans AMMM. 2020;2:1. https:\/\/doi.org\/10.18416\/AMMM.2020.2009011.","journal-title":"Trans AMMM"},{"key":"331_CR16","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/978-3-030-99838-7","volume-title":"The Future Circle of Healthcare. Future of Business and Finance","author":"FM Thieringer","year":"2022","unstructured":"Thieringer FM, Honigmann P, Sharma N. Medical additive manufacturing in surgery: translating innovation to the point of care. In: Ehsani S, Glauner P, Plugmann P, Thieringer FM, editors. The Future Circle of Healthcare. Future of Business and Finance. Cham: Springer; 2022. pp. 359\u201376. https:\/\/doi.org\/10.1007\/978-3-030-99838-7."},{"key":"331_CR17","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1108\/EJIM-11-2021-0579","volume":"25","author":"M Tani","year":"2022","unstructured":"Tani M, Troise C, De Bernardi P, Han T. Innovating the supply chain in health-related crises: some evidence from ISINNOVA case. Eur J Innov Manage. 2022;25:716\u201334. https:\/\/doi.org\/10.1108\/EJIM-11-2021-0579.","journal-title":"Eur J Innov Manage"},{"key":"331_CR18","doi-asserted-by":"publisher","unstructured":"Calvo-Haro JA, Pascau J, Asencio-Pascual JM, Calvo-Manuel F, Cancho-Gil MJ, Del Ca\u00f1izo L\u00f3pez JF, Fanjul-G\u00f3mez M, Garc\u00eda-Leal R, Gonz\u00e1lez-Casaurr\u00e1n G, Gonz\u00e1lez-Leyte M, Le\u00f3n-Luis JA, Mediavilla-Santos L, Ochandiano-Caicoya S, P\u00e9rez-Caballero R, Ribed-S\u00e1nchez A, R\u00edo-G\u00f3mez J, S\u00e1nchez-P\u00e9rez E, Serrano-Andreu J, Tousidonis-Rial M, Vaquero-Mart\u00edn J, Garc\u00eda San Jos\u00e9 J, Perez-Ma\u00f1anes R. Point-of-care manufacturing: a single university hospital\u2019s initial experience. 3D Print Med. 2021;7(11). https:\/\/doi.org\/10.1186\/s41205-021-00101-z.","DOI":"10.1186\/s41205-021-00101-z"},{"key":"331_CR19","unstructured":"European Commission. 2025. Medical devices topics of interest: house of medical devices. https:\/\/health.ec.europa.eu\/medical-devices-topics-interest\/house-medical-devices_en.(Accessed 28 August 2025)."},{"key":"331_CR20","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1007\/978-3-031-94495-6_11","volume-title":"Atlas of Virtual Surgical Planning and 3D Printing for Cranio-Maxillo-Facial Surgery","author":"N Sharma","year":"2025","unstructured":"Sharma N, Oteiza JZ, Seiler D, Thieringer FM. Personalized cranial implants: pioneering techniques with additive manufacturing. In: Tel A, Robiony M, editors. Atlas of Virtual Surgical Planning and 3D Printing for Cranio-Maxillo-Facial Surgery. Cham: Springer; 2025. pp. 161\u20139. https:\/\/doi.org\/10.1007\/978-3-031-94495-6_11."},{"key":"331_CR21","doi-asserted-by":"publisher","unstructured":"Sharma N, Oteiza JZ, Seiler D, Abazi S, Seifert LB, Roethlisberger M, Guzman R, Thieringer FM. Clinical implementation of an EU MDR-compliant point-of-care manufacturing framework for patient-specific 3D-printed PEEK implants in craniomaxillofacial reconstruction. 3D Print Med. 2026;12. https:\/\/doi.org\/10.1186\/s41205-026-00325-x.","DOI":"10.1186\/s41205-026-00325-x"},{"key":"331_CR22","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s40902-015-0001-9","volume":"37","author":"H Rotaru","year":"2015","unstructured":"Rotaru H, Schumacher R, Kim SG, Dinu C. Selective laser melted titanium implants: a new technique for the reconstruction of extensive zygomatic complex defects. Maxillofac Plast Reconstr Surg. 2015;37:2. https:\/\/doi.org\/10.1186\/s40902-015-0001-9.","journal-title":"Maxillofac Plast Reconstr Surg"},{"key":"331_CR23","unstructured":"Bibb R, Eggbeer D, Paterson A. Medical modelling: the application of advanced design and rapid prototyping techniques in medicine. 2nd ed. Amsterdam: Woodhead Publishing\/Elsevier; 2015. ISBN: 9781782423003."},{"key":"331_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/C2019-0-02458-2","volume-title":"3D Printing in Medicine and Surgery: Applications in Healthcare","year":"2020","unstructured":"Thomas DB, editor. 3D Printing in Medicine and Surgery: Applications in Healthcare. Amsterdam: Elsevier; 2020. https:\/\/doi.org\/10.1016\/C2019-0-02458-2."},{"key":"331_CR25","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1108\/13552540910993879","volume":"15","author":"R Bibb","year":"2009","unstructured":"Bibb R, Eggbeer D, Evans P, Bocca A, Sugar A. Rapid manufacture of custom-fitting surgical guides. Rapid Prototyp J. 2009;15:346\u201354. https:\/\/doi.org\/10.1108\/13552540910993879.","journal-title":"Rapid Prototyp J"},{"key":"331_CR26","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1108\/RPJ-01-2014-0004","volume":"22","author":"S Peel","year":"2016","unstructured":"Peel S, Eggbeer D. Additively manufactured maxillofacial implants and guides \u2013 achieving routine use. Rapid Prototyp J. 2016;22:189\u201399. https:\/\/doi.org\/10.1108\/RPJ-01-2014-0004.","journal-title":"Rapid Prototyp J"},{"key":"331_CR27","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1177\/0954411916681346","volume":"231","author":"S Peel","year":"2017","unstructured":"Peel S, Bhatia S, Eggbeer D, Morris DS, Hayhurst C. Evolution of design considerations in complex craniofacial reconstruction using patient-specific implants. Proc Inst Mech Eng H. 2017;231:509\u201324. https:\/\/doi.org\/10.1177\/0954411916681346.","journal-title":"Proc Inst Mech Eng H"},{"key":"331_CR28","doi-asserted-by":"publisher","first-page":"3563","DOI":"10.3390\/jcm10163563","volume":"10","author":"N Sharma","year":"2021","unstructured":"Sharma N, Welker D, Aghlmandi S, Maintz M, Zeilhofer HF, Honigmann P, Seifert T, Thieringer FM. A multi-criteria assessment strategy for 3D printed porous polyetheretherketone (PEEK) patient-specific implants for orbital wall reconstruction. J Clin Med. 2021;10:3563. https:\/\/doi.org\/10.3390\/jcm10163563.","journal-title":"J Clin Med"},{"key":"331_CR29","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3390\/cmtr19010013","volume":"19","author":"JZ Oteiza","year":"2026","unstructured":"Oteiza JZ, Haenggi D, Krieger YS, Schuebel L, Seiler D, Thieringer FM, Sharma N. Surgical performance of 3D-printed polyetheretherketone (PEEK) patient-specific implants and titanium mesh in clinically matched orbital reconstruction: a cadaveric study. Craniomaxillofac Trauma Reconstr. 2026;19:13. https:\/\/doi.org\/10.3390\/cmtr19010013.","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"331_CR30","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.3390\/app13031230","volume":"13","author":"P Zarean","year":"2023","unstructured":"Zarean P, Malgaroli P, Zarean P, Seiler D, de Wild M, Thieringer FM, Sharma N. Effect of printing parameters on mechanical performance of material-extrusion 3D-printed PEEK specimens at the point-of-care. Appl Sci. 2023;13:1230. https:\/\/doi.org\/10.3390\/app13031230.","journal-title":"Appl Sci"},{"key":"331_CR31","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.jmbbm.2012.09.013","volume":"17","author":"EL Steinberg","year":"2013","unstructured":"Steinberg EL, Rath E, Shlaifer A, Chechik O, Maman E, Salai M. Carbon fiber reinforced PEEK Optima\u2014a composite material biomechanical properties and wear\/debris characteristics of CF-PEEK composites for orthopedic trauma implants. J Mech Behav Biomed Mater. 2013;17:221\u20138. https:\/\/doi.org\/10.1016\/j.jmbbm.2012.09.013.","journal-title":"J Mech Behav Biomed Mater"},{"key":"331_CR32","doi-asserted-by":"publisher","first-page":"101674","DOI":"10.1016\/j.jcot.2021.101674","volume":"23","author":"K Theivendran","year":"2021","unstructured":"Theivendran K, Arshad F, Hanif UK, Reito A, Griffin X, Foote CJ. Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: a systematic review. J Clin Orthop Trauma. 2021;23:101674. https:\/\/doi.org\/10.1016\/j.jcot.2021.101674.","journal-title":"J Clin Orthop Trauma"},{"key":"331_CR33","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1016\/j.msec.2016.11.039","volume":"71","author":"M Ebrahimi","year":"2017","unstructured":"Ebrahimi M, Botelho MG, Dorozhkin SV. Biphasic calcium phosphates bioceramics (HA\/TCP): concept, physicochemical properties and the impact of standardization of study protocols in biomaterials research. Mater Sci Eng C Mater Biol Appl. 2017;71:1293\u2013312. https:\/\/doi.org\/10.1016\/j.msec.2016.11.039.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"331_CR34","doi-asserted-by":"publisher","first-page":"815","DOI":"10.3390\/ma3020815","volume":"3","author":"SE Lobo","year":"2010","unstructured":"Lobo SE, Arinzeh TL. Biphasic calcium phosphate ceramics for bone regeneration and tissue engineering applications. Mater (Basel). 2010;3:815\u201326. https:\/\/doi.org\/10.3390\/ma3020815.","journal-title":"Mater (Basel)"},{"key":"331_CR35","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s12938-023-01067-1","volume":"22","author":"P Jin","year":"2023","unstructured":"Jin P, Liu L, Cheng L, Sun C, Li T, Zhang X, Jiang Q, Peng J, Yuan G, He W, Gou Z. Calcium-to-phosphorus releasing ratio affects osteoinductivity and osteoconductivity of calcium phosphate bioceramics in bone tissue engineering. BioMed Eng OnLine. 2023;22:12. https:\/\/doi.org\/10.1186\/s12938-023-01067-1.","journal-title":"BioMed Eng OnLine"},{"key":"331_CR36","doi-asserted-by":"publisher","first-page":"105965","DOI":"10.1016\/j.jmbbm.2023.105965","volume":"144","author":"JA Smith","year":"2023","unstructured":"Smith JA, Petersmann S, Arbeiter F, Sch\u00e4fer U. Optimization and manufacture of polyetheretherketone patient specific cranial implants by material extrusion\u2014a clinical perspective. J Mech Behav Biomed Mater. 2023;144:105965. https:\/\/doi.org\/10.1016\/j.jmbbm.2023.105965.","journal-title":"J Mech Behav Biomed Mater"},{"key":"331_CR37","doi-asserted-by":"publisher","first-page":"3426","DOI":"10.3390\/jcm12103426","volume":"12","author":"AK Singh","year":"2023","unstructured":"Singh AK, Khanal N, Chaulagain R, Sharma N, Thieringer FM. Is the pre-shaping of an orbital implant on a patient-specific 3D-printed model advantageous compared to conventional free-hand shaping? A systematic review and meta-analysis. J Clin Med. 2023;12:3426. https:\/\/doi.org\/10.3390\/jcm12103426.","journal-title":"J Clin Med"},{"key":"331_CR38","doi-asserted-by":"publisher","first-page":"2495","DOI":"10.3390\/jcm12072495","volume":"12","author":"N Sharma","year":"2023","unstructured":"Sharma N, Zubizarreta-Oteiza J, Tourbier C, Thieringer FM. Can steam sterilization affect the accuracy of point-of-care 3D printed polyetheretherketone (PEEK) customized cranial implants? An investigative analysis. J Clin Med. 2023;12:2495. https:\/\/doi.org\/10.3390\/jcm12072495.","journal-title":"J Clin Med"},{"key":"331_CR39","doi-asserted-by":"publisher","first-page":"18","DOI":"10.3390\/bioengineering5010018","volume":"5","author":"A Kumar","year":"2018","unstructured":"Kumar A, Yap WT, Foo SL, Lee TK. Effects of sterilization cycles on PEEK for medical device application. Bioeng (Basel). 2018;5:18. https:\/\/doi.org\/10.3390\/bioengineering5010018.","journal-title":"Bioeng (Basel)"}],"container-title":["3D Printing in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41205-026-00331-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-026-00331-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41205-026-00331-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T07:39:18Z","timestamp":1782373158000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41205-026-00331-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["331"],"URL":"https:\/\/doi.org\/10.1186\/s41205-026-00331-z","relation":{},"ISSN":["2365-6271"],"issn-type":[{"value":"2365-6271","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]},"assertion":[{"value":"12 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21"}}