{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T16:00:55Z","timestamp":1773504055316,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T00:00:00Z","timestamp":1610409600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T00:00:00Z","timestamp":1610409600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Multidetector row computed tomography (CT) scanners perform dynamic scanning and have a wide scan range. Time-resolved three-dimensional CT (<jats:italic>i.e.<\/jats:italic>, 4D CT) has recently enabled visualization of flow in neurovascular vessels. We hypothesized that 4D CT technology would be a useful and non-invasive method for visualizing the flow dynamics of the portal circulation. The aim of this study was to evaluate the technical feasibility of 4D CT for visualizing flow dynamics in the portal circulation using 320-detector-row CT. 4D CT images of 18 consecutive patients with portal circulation including gastrorenal shunt were retrospectively evaluated for their ability to generate flow dynamics of the portal circulation. Flow dynamics could be visualized by 4D CT in 68 of the 72 vessels in the portal vein, splenic vein, superior mesenteric vein, and gastrorenal shunt. Flow direction could not be identified in four vessels, all of them being superior mesenteric veins. Flow direction was recognized on 4D CT in the 68 vessels of the portal circulation. A preliminary validation study revealed that flow direction of all 19 vessels in the portal circulation had concordance between 4D CT and color Doppler ultrasound. 4D CT could visualize flow dynamics of the portal circulation.<\/jats:p>","DOI":"10.1186\/s41747-020-00197-8","type":"journal-article","created":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T04:00:05Z","timestamp":1610424005000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Visualization of flow dynamics in the portal circulation using 320-detector-row computed tomography: a feasibility study"],"prefix":"10.1186","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0787-9789","authenticated-orcid":false,"given":"Ken","family":"Kageyama","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Jogo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichiro","family":"Izuta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Himoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akihiko","family":"Kakimi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Etsuji","family":"Sohgawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukio","family":"Miki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,12]]},"reference":[{"key":"197_CR1","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1002\/hep.24129","volume":"53","author":"D Thabut","year":"2011","unstructured":"Thabut D, Moreau R, Lebrec D (2011) Noninvasive assessment of portal hypertension in patients with cirrhosis. Hepatology 53:683\u2013694. https:\/\/doi.org\/10.1002\/hep.24129","journal-title":"Hepatology"},{"key":"197_CR2","doi-asserted-by":"publisher","first-page":"8894","DOI":"10.3748\/wjg.v21.i29.8894","volume":"21","author":"T Kondo","year":"2015","unstructured":"Kondo T, Maruyama H, Sekimoto T, Shimada T, Takahashi M, Yokosuka O (2015) Reversed portal flow: Clinical influence on the long-term outcomes in cirrhosis. World J Gastroenterol 21:8894\u20138902. https:\/\/doi.org\/10.3748\/wjg.v21.i29.8894","journal-title":"World J Gastroenterol"},{"key":"197_CR3","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1111\/j.1478-3231.2010.02326.x","volume":"30","author":"SK Baik","year":"2010","unstructured":"Baik SK (2010) Haemodyanmic evaluation by doppler ultrasonography in patients with portal hypertension: a review. Liver Int 30:1403\u20131413. https:\/\/doi.org\/10.1111\/j.1478-3231.2010.02326.x","journal-title":"Liver Int"},{"key":"197_CR4","doi-asserted-by":"publisher","unstructured":"Kim G, Cho YZ, Baik SK, Kim MY, Hong WK, Kwon SO (2015) The accuracy of ultrasonography for the evaluation of portal hypertension in patients with cirrhosis: a systemic review. Korean J Radiol 16:314\u2013324. https:\/\/doi.org\/10.3348\/kjr.2015.16.2.314","DOI":"10.3348\/kjr.2015.16.2.314"},{"key":"197_CR5","doi-asserted-by":"publisher","first-page":"2634","DOI":"10.1007\/s00330-015-3663-x","volume":"25","author":"Z Stankovic","year":"2015","unstructured":"Stankovic Z, R\u00f6ssle M, Euringer W et al (2015) Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI. Eur Radiol 25:2634\u20132640. https:\/\/doi.org\/10.1007\/s00330-015-3663-x","journal-title":"Eur Radiol"},{"key":"197_CR6","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1002\/jmri.24233","volume":"39","author":"BR Landgraf","year":"2014","unstructured":"Landgraf BR, Johnson KM, Rold\u00e1n-Alzate A, Francois CJ, Wieben O, Reeder SB (2014) Effect of temporal resolution on 4D flow MRI in the portal circulation. J Magn Reson Imaging 39:819\u2013826. https:\/\/doi.org\/10.1002\/jmri.24233","journal-title":"J Magn Reson Imaging"},{"key":"197_CR7","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1148\/radiol.11101541","volume":"261","author":"H Gouya","year":"2011","unstructured":"Gouya H, Vignaux O, Sogni P et al (2011) Chronic liver disease: systemic and splanchnic venous flow mapping with optimized cine phase-contrast MR imaging validated in a phantom model and prospectively evaluated in patients. Radiology 261:144\u2013155. https:\/\/doi.org\/10.1148\/radiol.11101541","journal-title":"Radiology"},{"key":"197_CR8","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1186\/1471-230X-11-84","volume":"11","author":"L Zhang","year":"2011","unstructured":"Zhang L, Yin J, Duan Y, Yang Y, Yuan L, Cao T (2011) Assessment of intrahepatic blood flow by Doppler ultrasonography: relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension. BMC Gastroenterol 11:84. https:\/\/doi.org\/10.1186\/1471-230X-11-84","journal-title":"BMC Gastroenterol"},{"key":"197_CR9","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1023\/a:1018814624307","volume":"43","author":"Y Chawla","year":"1998","unstructured":"Chawla Y, Santa N, Dhiman RK, Dilawari JB (1998) Portal hemodynamics by duplex Doppler sonography in different grades of cirrhosis. Dig Dis Sci 43:354\u2013357. https:\/\/doi.org\/10.1023\/a:1018814624307","journal-title":"Dig Dis Sci"},{"key":"197_CR10","doi-asserted-by":"publisher","first-page":"989","DOI":"10.2214\/ajr.161.5.8273643","volume":"161","author":"JP Finn","year":"1993","unstructured":"Finn JP, Kane RA, Edelman RR et al (1993) Imaging of the portal venous system in patients with cirrhosis: MR angiography vs duplex Doppler sonography. AJR Am J Roentgenol 161:989\u2013994","journal-title":"AJR Am J Roentgenol"},{"key":"197_CR11","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1016\/0168-8278(91)90081-l","volume":"13","author":"PJ de Vries","year":"1991","unstructured":"de Vries PJ, van Hattum J, Hoekstra JB, de Hooge P (1991) Duplex Doppler measurements of portal venous flow in normal subjects. Inter- and intra-observer variability. J Hepatol 13:358\u2013363. https:\/\/doi.org\/10.1016\/0168-8278(91)90081-l","journal-title":"J Hepatol"},{"key":"197_CR12","doi-asserted-by":"publisher","first-page":"1848","DOI":"10.2214\/ajr.184.6.01841848","volume":"184","author":"AK Lim","year":"2005","unstructured":"Lim AK, Patel N, Eckersley RJ et al (2005) Can Doppler sonography grade the severity of hepatitis C-related liver disease? AJR Am J Roentgenol 184:1848\u20131853. https:\/\/doi.org\/10.2214\/ajr.184.6.01841848","journal-title":"AJR Am J Roentgenol"},{"key":"197_CR13","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1146\/annurev-bioeng-100219-110055","volume":"22","author":"G Soulat","year":"2020","unstructured":"Soulat G, McCarthy P, Markl M (2020) 4D flow with MRI. Annu Rev Biomed Eng 22:103\u2013126. https:\/\/doi.org\/10.1146\/annurev-bioeng-100219-110055","journal-title":"Annu Rev Biomed Eng"},{"key":"197_CR14","doi-asserted-by":"publisher","first-page":"899","DOI":"10.2214\/ajr.176.4.1760899","volume":"176","author":"A Matsumoto","year":"2001","unstructured":"Matsumoto A, Kitamoto M, Imamura M et al (2001) Three-dimensional portography using multislice helical CT is clinically useful for management of gastric fundic varices. AJR Am J Roentgenol 176:899\u2013905. https:\/\/doi.org\/10.2214\/ajr.176.4.1760899","journal-title":"AJR Am J Roentgenol"},{"key":"197_CR15","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1007\/s00270-011-0233-8","volume":"35","author":"K Kageyama","year":"2012","unstructured":"Kageyama K, Nishida N, Matsui H, Yamamoto A, Nakamura K, Miki Y (2012) Successful balloon-occluded retrograde transvenous obliteration for gastric varix mainly draining into the pericardiophrenic vein. Cardiovasc Intervent Radiol 35:180\u2013183. https:\/\/doi.org\/10.1007\/s00270-011-0233-8","journal-title":"Cardiovasc Intervent Radiol"},{"key":"197_CR16","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.1007\/s00270-013-0809-6","volume":"37","author":"A Jogo","year":"2014","unstructured":"Jogo A, Nishida N, Yamamoto A et al (2014) Factors associated with aggravation of esophageal varices after B-RTO for gastric varices. Cardiovasc Intervent Radiol 37:1243\u20131250. https:\/\/doi.org\/10.1007\/s00270-013-0809-6","journal-title":"Cardiovasc Intervent Radiol"},{"key":"197_CR17","doi-asserted-by":"publisher","first-page":"20190751","DOI":"10.1259\/bjr.20190751","volume":"93","author":"A Jogo","year":"2020","unstructured":"Jogo A, Yamamoto A, Kaminoh T et al (2020) Utility of low-dose gelatin sponge particles and 5% ethanolamine oleate iopamidol mixture in retrograde transvenous obliteration (GERTO) for gastric varices. Br J Radiol 93:20190751. https:\/\/doi.org\/10.1259\/bjr.20190751","journal-title":"Br J Radiol"},{"key":"197_CR18","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1148\/radiol.2016152247","volume":"281","author":"P Bannas","year":"2016","unstructured":"Bannas P, Rold\u00e1n-Alzate A, Johnson K et al (2016) Longitudinal monitoring of hepatic blood flow before and after TIPS by using 4D-flow MR imaging. Radiology 281:574\u2013582. https:\/\/doi.org\/10.1148\/radiol.2016152247","journal-title":"Radiology"},{"key":"197_CR19","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1148\/radiol.2018180230","volume":"290","author":"U Motosugi","year":"2019","unstructured":"Motosugi U, Rold\u00e1n-Alzate A, Bannas P et al (2019) Four-dimensional flow MRI as a marker for risk stratification of gastroesophageal varices in patients with liver cirrhosis. Radiology 290:101\u2013107. https:\/\/doi.org\/10.1148\/radiol.2018180230","journal-title":"Radiology"},{"key":"197_CR20","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1111\/hepr.13199","volume":"48","author":"T Ishikawa","year":"2018","unstructured":"Ishikawa T, Sasaki R, Nishimura T et al (2018) Comparison of patients with hepatic encephalopathy and those with gastric varices before and after balloon-occluded retrograde transvenous obliteration. Hepatol Res 48:1020\u20131030. https:\/\/doi.org\/10.1111\/hepr.13199","journal-title":"Hepatol Res"},{"key":"197_CR21","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s10143-012-0440-z","volume":"36","author":"S Yamaguchi","year":"2013","unstructured":"Yamaguchi S, Takeda M, Mitsuhara T et al (2013) Application of 4D-CTA using 320-row are detector computed tomography on spinal arteriovenous fistulae: initial experience. Neurosurg Rev 36:289\u2013296. https:\/\/doi.org\/10.1007\/s10143-012-0440-z","journal-title":"Neurosurg Rev"},{"key":"197_CR22","doi-asserted-by":"publisher","first-page":"20140454","DOI":"10.1259\/bjr.20140454","volume":"87","author":"MJ Parkes","year":"2014","unstructured":"Parkes MJ, Green S, Stevens AM, Clutton-Brock TH (2014) Assessing and ensuring patient safety during breath-holding for radiotherapy. Br J Radiol 87:20140454. https:\/\/doi.org\/10.1259\/bjr.20140454","journal-title":"Br J Radiol"},{"key":"197_CR23","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1177\/0284185119868909","volume":"61","author":"S Mori","year":"2019","unstructured":"Mori S, Yashiro H, Inoue M, Takahara K, Kusaka M, Shiroki R (2019) Urodynamic 4D-CT evaluation: 320-row area detector CT scanner combined with PhyZiodynamics software analysis provides an innovative system to evaluate urinary flow and outlet obstructions. Acta Radiol 61:558\u2013567. https:\/\/doi.org\/10.1177\/0284185119868909","journal-title":"Acta Radiol"},{"key":"197_CR24","doi-asserted-by":"publisher","unstructured":"Sugano S, Yamamoto K, Sasao K, Watanabe M (1999) Portal venous blood flow while breath-holding after inspiration or expiration and during normal respiration in controls and cirrhotics. J Gastroenterol 34:613\u2013618. https:\/\/doi.org\/10.1007\/s005350050381","DOI":"10.1007\/s005350050381"},{"key":"197_CR25","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1148\/radiol.2017161911","volume":"284","author":"KM Kanal","year":"2017","unstructured":"Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL (2017) U.S. diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology 284:120\u2013133. https:\/\/doi.org\/10.1148\/radiol.2017161911","journal-title":"Radiology"},{"key":"197_CR26","unstructured":"Japanese Network for Research and Information on Medical Exposure (2015) Diagnostic reference levels based on latest surveys in Japan \u2013 Japan DRLs 2015. http:\/\/www.radher.jp\/J-RIME\/report\/DRLhoukokusyoEng.pdf. Accessed 26 Aug 2020"},{"key":"197_CR27","volume-title":"Radiation Protection No. 180 \u2013 Diagnostic reference levels in thirty-six European countries (Part 2\/2)","author":"European Commission","year":"2014","unstructured":"European Commission (2014) Radiation Protection No. 180 \u2013 Diagnostic reference levels in thirty-six European countries (Part 2\/2). https:\/\/ec.europa.eu\/energy\/sites\/ener\/files\/documents\/RP180%20part2.pdf. Accessed 26 Aug 2020"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-020-00197-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s41747-020-00197-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-020-00197-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T04:29:47Z","timestamp":1610425787000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-020-00197-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,12]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["197"],"URL":"https:\/\/doi.org\/10.1186\/s41747-020-00197-8","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,12]]},"assertion":[{"value":"30 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 November 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study was approved by our Institutional Committee on Human Investigation (Reference number, 2019-027).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1"}}