{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T05:16:46Z","timestamp":1790831806772,"version":"4.1.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,2]],"date-time":"2021-12-02T00:00:00Z","timestamp":1638403200000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100014984","name":"European Society of Musculoskeletal Radiology","doi-asserted-by":"crossref","award":["Young Researcher Grant"],"award-info":[{"award-number":["Young Researcher Grant"]}],"id":[{"id":"10.13039\/100014984","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Intra-articular blood causes irreversible joint damage, whilst clinical differentiation between haemorrhagic joint effusion and other effusions can be challenging. An accurate non-invasive method for the detection of joint bleeds is lacking. The aims of this phantom study were to investigate whether magnetic resonance imaging (MRI) T1 and T2 mapping allows for differentiation between simple and haemorrhagic joint effusion and to determine the lowest blood concentration that can be detected.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Solutions of synovial fluid with blood concentrations ranging from 0 to 100% were scanned at 1.5, 3, and 7\u2009T. T1 maps were generated with an inversion recovery technique and T2 maps from multi spin-echo sequences. In both cases, the scan acquisition times were below 5\u2009min. Regions of interest were manually drawn by two observers in the obtained T1 and T2 maps for each sample. The lowest detectable blood concentration was determined for all field strengths.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>At all field strengths, T1 and T2 relaxation times decreased with higher blood concentrations. The lowest detectable blood concentrations using T1 mapping were 10% at 1.5\u2009T, 25% at 3\u2009T, and 50% at 7\u2009T. For T2 mapping, the detection limits were 50%, 5%, and 25%, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      T1 and T2 mapping can detect different blood concentrations in synovial fluid\n                      <jats:italic>in vitro<\/jats:italic>\n                      at clinical field strengths. Especially, T2 measurements at 3\u2009T showed to be highly sensitive. Short acquisition times would make these methods suitable for clinical use and therefore might be promising tools for accurate discrimination between simple and haemorrhagic joint effusion\n                      <jats:italic>in vivo<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-021-00251-z","type":"journal-article","created":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T21:02:59Z","timestamp":1638392579000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Detecting low blood concentrations in joints using T1 and T2 mapping at 1.5, 3, and 7 T: an in vitro study"],"prefix":"10.1186","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8384-4385","authenticated-orcid":false,"given":"Flora H. P.","family":"van Leeuwen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beatrice","family":"Lena","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaco J. M.","family":"Zwanenburg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lize F. D.","family":"van Vulpen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lambertus W.","family":"Bartels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathelijn","family":"Fischer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank J.","family":"Nap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pim A.","family":"de Jong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens","family":"Bos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wouter","family":"Foppen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,12,2]]},"reference":[{"key":"251_CR1","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.phrs.2016.11.032","volume":"115","author":"AE Pulles","year":"2017","unstructured":"Pulles AE, Mastbergen SC, Schutgens REG et al (2017) Pathophysiology of hemophilic arthropathy and potential targets for therapy. Pharmacol Res 115:192\u2013199. https:\/\/doi.org\/10.1016\/j.phrs.2016.11.032","journal-title":"Pharmacol Res"},{"key":"251_CR2","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1111\/j.1365-2141.2008.07386.x","volume":"143","author":"NWD Jansen","year":"2008","unstructured":"Jansen NWD, Roosendaal G, Lafeber FPJG (2008) Understanding haemophilic arthropathy: an exploration of current open issues. Br J Haematol 143:632\u2013640. https:\/\/doi.org\/10.1111\/j.1365-2141.2008.07386.x","journal-title":"Br J Haematol"},{"key":"251_CR3","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1002\/art.22304","volume":"56","author":"NWD Jansen","year":"2007","unstructured":"Jansen NWD, Roosendaal G, Bijlsma JWJ et al (2007) Exposure of human cartilage tissue to low concentrations of blood for a short period of time leads to prolonged cartilage damage: an in vitro study. Arthritis Rheum 56:199\u2013207. https:\/\/doi.org\/10.1002\/art.22304","journal-title":"Arthritis Rheum"},{"key":"251_CR4","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1111\/hae.12667","volume":"21","author":"MA Timmer","year":"2015","unstructured":"Timmer MA, Pisters MF, de Kleijn P et al (2015) Differentiating between signs of intra-articular joint bleeding and chronic arthropathy in haemophilia: a narrative review of the literature. Haemophilia 21:289\u2013296. https:\/\/doi.org\/10.1111\/hae.12667","journal-title":"Haemophilia"},{"key":"251_CR5","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1111\/hae.12175","volume":"19","author":"A Ceponis","year":"2013","unstructured":"Ceponis A, Wong-Sefidan I, Glass CS, von Drygalski A (2013) Rapid musculoskeletal ultrasound for painful episodes in adult haemophilia patients. Haemophilia 19:790\u2013798. https:\/\/doi.org\/10.1111\/hae.12175","journal-title":"Haemophilia"},{"key":"251_CR6","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1002\/art.1780290816","volume":"29","author":"R Altman","year":"1986","unstructured":"Altman R, Asch E, Bloch D et al (1986) Development of criteria for the classification and reporting of osteoarthritis: classification of osteoarthritis of the knee. Arthritis Rheum 29:1039\u20131049. https:\/\/doi.org\/10.1002\/art.1780290816","journal-title":"Arthritis Rheum"},{"key":"251_CR7","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1111\/hae.12338","volume":"20","author":"W Foppen","year":"2014","unstructured":"Foppen W, van der Schaaf IC, Witkamp TD, Fischer K (2014) Is joint effusion on MRI specific for haemophilia? Haemophilia 20:582\u2013586. https:\/\/doi.org\/10.1111\/hae.12338","journal-title":"Haemophilia"},{"key":"251_CR8","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1111\/hae.13925","volume":"26","author":"M Eerdekens","year":"2020","unstructured":"Eerdekens M, Peerlinck K, Staes F et al (2020) Clinical gait features are associated with MRI findings in patients with haemophilic ankle arthropathy. Haemophilia 26:333\u2013339. https:\/\/doi.org\/10.1111\/hae.13925","journal-title":"Haemophilia"},{"key":"251_CR9","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1111\/j.1365-2516.2005.01061.x","volume":"11","author":"B Lundin","year":"2005","unstructured":"Lundin B, Ljung R, Pettersson H (2005) MRI scores of ankle joints in children with haemophilia - comparison with clinical data. Haemophilia 11:116\u2013122. https:\/\/doi.org\/10.1111\/j.1365-2516.2005.01061.x","journal-title":"Haemophilia"},{"key":"251_CR10","doi-asserted-by":"publisher","first-page":"1512","DOI":"10.1002\/jmri.26618","volume":"49","author":"CJ Burke","year":"2019","unstructured":"Burke CJ, Alizai H, Beltran LS, Regatte RR (2019) MRI of synovitis and joint fluid. J Magn Reson Imaging 49:1512\u20131527. https:\/\/doi.org\/10.1002\/jmri.26618","journal-title":"J Magn Reson Imaging"},{"key":"251_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/hae.14046","volume":"26","author":"A Srivastava","year":"2020","unstructured":"Srivastava A, Santagostino E, Dougall A et al (2020) WFH guidelines for the management of hemophilia, 3rd edition. Haemophilia 26:1\u2013158. https:\/\/doi.org\/10.1111\/hae.14046","journal-title":"Haemophilia"},{"key":"251_CR12","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1002\/art.41142","volume":"72","author":"SL Kolasinski","year":"2020","unstructured":"Kolasinski SL, Neogi T, Hochberg MC et al (2020) 2019 American College of Rheumatology\/Arthritis Foundation Guideline for the Management of Osteoarthritis of the Hand, Hip, and Knee. Arthritis Rheum 72:220\u2013233. https:\/\/doi.org\/10.1002\/art.41142","journal-title":"Arthritis Rheum"},{"key":"251_CR13","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1111\/j.1365-2516.2012.02909.x","volume":"19","author":"A Srivastava","year":"2013","unstructured":"Srivastava A, Brewer AK, Mauser-Bunschoten EP et al (2013) Guidelines for the management of hemophilia. Haemophilia 19:e1\u2013e47. https:\/\/doi.org\/10.1111\/j.1365-2516.2012.02909.x","journal-title":"Haemophilia"},{"key":"251_CR14","doi-asserted-by":"publisher","first-page":"W336","DOI":"10.2214\/AJR.14.12501","volume":"204","author":"AS Doria","year":"2015","unstructured":"Doria AS, Keshava SN, Mohanta A et al (2015) Diagnostic accuracy of ultrasound for assessment of hemophilic arthropathy: MRI correlation. AJR Am J Roentgenol 204:W336\u2013W347. https:\/\/doi.org\/10.2214\/AJR.14.12501","journal-title":"AJR Am J Roentgenol"},{"key":"251_CR15","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1111\/hae.13524","volume":"24","author":"W Foppen","year":"2018","unstructured":"Foppen W, van der Schaaf IC, Beek FJA et al (2018) Diagnostic accuracy of point-of-care ultrasound for evaluation of early blood-induced joint changes: comparison with MRI. Haemophilia 24:971\u2013979. https:\/\/doi.org\/10.1111\/hae.13524","journal-title":"Haemophilia"},{"key":"251_CR16","doi-asserted-by":"publisher","first-page":"e000950","DOI":"10.1136\/rmdopen-2019-000950","volume":"5","author":"P Mandl","year":"2019","unstructured":"Mandl P, Ciechomska A, Terslev L et al (2019) Implementation and role of modern musculoskeletal imaging in rheumatological practice in member countries of EULAR. RMD Open 5:e000950. https:\/\/doi.org\/10.1136\/rmdopen-2019-000950","journal-title":"RMD Open"},{"key":"251_CR17","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1111\/jth.13930","volume":"16","author":"S Nguyen","year":"2018","unstructured":"Nguyen S, Lu X, Ma Y et al (2018) Musculoskeletal ultrasound for intra-articular bleed detection: a highly sensitive imaging modality compared with conventional magnetic resonance imaging. J Thromb Haemost 16:490\u2013499. https:\/\/doi.org\/10.1111\/jth.13930","journal-title":"J Thromb Haemost"},{"key":"251_CR18","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1111\/hae.14303","volume":"27","author":"SS Regi","year":"2021","unstructured":"Regi SS, Livingstone RS, Kandagaddala M et al (2021) Ultrasound and magnetic resonance imaging for the detection of blood: an ex-vivo study. Haemophilia 27:488\u2013493. https:\/\/doi.org\/10.1111\/hae.14303","journal-title":"Haemophilia"},{"key":"251_CR19","doi-asserted-by":"publisher","first-page":"840 LP","DOI":"10.1136\/annrheumdis-2020-219816","volume":"80","author":"F Costantino","year":"2021","unstructured":"Costantino F, Carmona L, Boers M et al (2021) EULAR recommendations for the reporting of ultrasound studies in rheumatic and musculoskeletal diseases (RMDs). Ann Rheum Dis 80:840 LP\u2013840847. https:\/\/doi.org\/10.1136\/annrheumdis-2020-219816","journal-title":"Ann Rheum Dis"},{"key":"251_CR20","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1002\/mrm.1085","volume":"45","author":"S Clare","year":"2001","unstructured":"Clare S, Jezzard P (2001) RapidT1 mapping using multislice echo planar imaging. Magn Reson Med 45:630\u2013634. https:\/\/doi.org\/10.1002\/mrm.1085","journal-title":"Magn Reson Med"},{"key":"251_CR21","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1088\/0031-9155\/46\/2\/312","volume":"46","author":"C Baldock","year":"2001","unstructured":"Baldock C, Lepage M, B\u00e4ck S\u00c5J et al (2001) Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence. Phys Med Biol 46:449\u2013460. https:\/\/doi.org\/10.1088\/0031-9155\/46\/2\/312","journal-title":"Phys Med Biol"},{"key":"251_CR22","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1002\/9781118633953.ch8","volume-title":"Magnetic resonance imaging","author":"RW Brown","year":"2014","unstructured":"Brown RW, Cheng Y-CN, Haacke EM et al (2014) Introductory signal acquisition methods. In: Magnetic resonance imaging, 2nd edn. Wiley & Sons, Inc., Hoboken, pp 113\u2013139","edition":"2"},{"key":"251_CR23","unstructured":"Armbruster DA, Pry T (2008) Limit of blank, limit of detection and limit of quantification. Clin Biochem Rev 29(Suppl 1):S49\u201352."},{"key":"251_CR24","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307\u2013310","journal-title":"Lancet"},{"key":"251_CR25","doi-asserted-by":"publisher","first-page":"343","DOI":"10.2214\/ajr.183.2.1830343","volume":"183","author":"GE Gold","year":"2004","unstructured":"Gold GE, Han E, Stainsby J et al (2004) Musculoskeletal MRI at 3.0\u2009T: relaxation times and image contrast. Am J Roentgenol 183:343\u2013351. https:\/\/doi.org\/10.2214\/ajr.183.2.1830343","journal-title":"Am J Roentgenol"},{"key":"251_CR26","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1002\/mrm.20605","volume":"54","author":"GJ Stanisz","year":"2005","unstructured":"Stanisz GJ, Odrobina EE, Pun J et al (2005) T1, T2 relaxation and magnetization transfer in tissue at 3\u2009T. Magn Reson Med 54:507\u2013512. https:\/\/doi.org\/10.1002\/mrm.20605","journal-title":"Magn Reson Med"},{"key":"251_CR27","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1002\/mrm.24550","volume":"70","author":"X Zhang","year":"2013","unstructured":"Zhang X, Petersen ET, Ghariq E et al (2013) In vivo blood T 1 measurements at 1.5\u2009T, 3\u2009T, and 7\u2009T. Magn Reson Med 70:1082\u20131086. https:\/\/doi.org\/10.1002\/mrm.24550","journal-title":"Magn Reson Med"},{"key":"251_CR28","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1016\/j.ejrad.2011.09.021","volume":"82","author":"CD Jordan","year":"2013","unstructured":"Jordan CD, Saranathan M, Bangerter NK et al (2013) Musculoskeletal MRI at 3.0\u2009T and 7.0\u2009T: a comparison of relaxation times and image contrast. Eur J Radiol 82:734\u2013739. https:\/\/doi.org\/10.1016\/j.ejrad.2011.09.021","journal-title":"Eur J Radiol"},{"key":"251_CR29","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1002\/mrm.20178","volume":"52","author":"H Lu","year":"2004","unstructured":"Lu H, Clingman C, Golay X, van Zijl PCM (2004) Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med 52:679\u2013682. https:\/\/doi.org\/10.1002\/mrm.20178","journal-title":"Magn Reson Med"},{"key":"251_CR30","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/j.mri.2006.10.020","volume":"25","author":"MC Dobre","year":"2007","unstructured":"Dobre MC, U\u011furbil K, Marjanska M (2007) Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths. Magn Reson Imaging 25:733\u2013735. https:\/\/doi.org\/10.1016\/j.mri.2006.10.020","journal-title":"Magn Reson Imaging"},{"key":"251_CR31","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1002\/mrm.24868","volume":"71","author":"LC Krishnamurthy","year":"2014","unstructured":"Krishnamurthy LC, Liu P, Xu F et al (2014) Dependence of blood T 2 on oxygenation at 7\u2009T: in vitro calibration and in vivo application. Magn Reson Med 71:2035\u20132042. https:\/\/doi.org\/10.1002\/mrm.24868","journal-title":"Magn Reson Med"},{"key":"251_CR32","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1002\/mrm.1910320508","volume":"32","author":"RM Henkelman","year":"1994","unstructured":"Henkelman RM, Stanisz GJ, Kim JK, Bronskill MJ (1994) Anisotropy of NMR properties of tissues. Magn Reson Med 32:592\u2013601. https:\/\/doi.org\/10.1002\/mrm.1910320508","journal-title":"Magn Reson Med"},{"key":"251_CR33","doi-asserted-by":"publisher","first-page":"339","DOI":"10.2214\/ajr.158.2.1370362","volume":"158","author":"L Yao","year":"1992","unstructured":"Yao L, Sinha S, Seeger LL (1992) MR imaging of joints: analytic optimization of GRE techniques at 1.5\u2009T. Am J Roentgenol 158:339\u2013345. https:\/\/doi.org\/10.2214\/ajr.158.2.1370362","journal-title":"Am J Roentgenol"},{"key":"251_CR34","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1002\/jmri.1880030414","volume":"3","author":"JWM Bulte","year":"1993","unstructured":"Bulte JWM, Vymazal J, Brooks RA et al (1993) Frequency dependence of MR relaxation times II. Iron oxides. J Magn Reson Imaging 3:641\u2013648. https:\/\/doi.org\/10.1002\/jmri.1880030414","journal-title":"J Magn Reson Imaging"},{"key":"251_CR35","doi-asserted-by":"publisher","first-page":"S34","DOI":"10.1016\/S1076-6332(03)80391-4","volume":"9","author":"KE Kellar","year":"2002","unstructured":"Kellar KE, Fujii DK, Gunther WHH et al (2002) Important considerations in the design of iron oxide nanoparticles as contrast agents for Tl-weighted MRI and MRA. Acad Radiol 9:S34\u2013S37. https:\/\/doi.org\/10.1016\/S1076-6332(03)80391-4","journal-title":"Acad Radiol"},{"key":"251_CR36","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1007\/s00330-005-0031-2","volume":"16","author":"GH Simon","year":"2006","unstructured":"Simon GH, Bauer J, Saborovski O et al (2006) T1 and T2 relaxivity of intracellular and extracellular USPIO at 1.5\u2009T and 3\u2009T clinical MR scanning. Eur Radiol 16:738\u2013745. https:\/\/doi.org\/10.1007\/s00330-005-0031-2","journal-title":"Eur Radiol"},{"key":"251_CR37","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/0304-4165(82)90333-6","volume":"714","author":"KR Thulborn","year":"1982","unstructured":"Thulborn KR, Waterton JC, Matthews PM, Radda GK (1982) Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim Biophys Acta, Gen Subj 714:265\u2013270. https:\/\/doi.org\/10.1016\/0304-4165(82)90333-6","journal-title":"Biochim Biophys Acta, Gen Subj"},{"key":"251_CR38","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1148\/radiology.175.1.2315481","volume":"175","author":"RA Clark","year":"1990","unstructured":"Clark RA, Watanabe AT, Bradley WG, Roberts JD (1990) Acute hematomas: effects of deoxygenation, hematocrit, and fibrin-clot formation and retraction on T2 shortening. Radiology 175:201\u2013206. https:\/\/doi.org\/10.1148\/radiology.175.1.2315481","journal-title":"Radiology"},{"key":"251_CR39","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1038\/nm0298-159","volume":"4","author":"PCM van Zijl","year":"1998","unstructured":"van Zijl PCM, Eleff SM, Ulatowski JA et al (1998) Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging. Nat Med 4:159\u2013167. https:\/\/doi.org\/10.1038\/nm0298-159","journal-title":"Nat Med"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-021-00251-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-021-00251-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-021-00251-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T21:06:26Z","timestamp":1638392786000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-021-00251-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["251"],"URL":"https:\/\/doi.org\/10.1186\/s41747-021-00251-z","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"9 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 October 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All patients or their legal guardians approved the use of their remnant samples for method development, validation, and research purposes, in agreement with Article 8. \u201cProcessing, storing, release and use of human biological material in accordance with \u2018no objection\u2019 procedure\u201d of the University Medical Center Utrecht Biobank Regulations (version June 19, 2013).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors of this manuscript declare relationships with the following companies: WF has received research grants from NovoNordisk and Pfizer which were paid to the institution. LV received a research grant from CSL Behring which was paid to the institution and reports to be in the advisory boards of Swedish Orphan Biovitrum BV (sobi), Tremeau Pharmaceuticals and CSL Behring. KF has received speaker's fees from Bayer, Baxter\/Shire, Biotest, CSL Behring, Octapharma, Pfizer, NovoNordisk; performed consultancy for Baxter\/Shire, Biogen, CSL-Behring, Freeline, NovoNordisk, Pfizer, Roche and SOBI; and has received research support from Bayer, Pfizer, Baxter\/Shire, and Novo Nordisk. PJ reported to perform consultancy for Sanifit and Inozyme. The Radiology department of the University Medical Center Utrecht received research support from Philips.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"51"}}