{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T09:45:53Z","timestamp":1767174353303,"version":"build-2238731810"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"German Roentgen Society","award":["2018_01: 7T MRI of the wrist"],"award-info":[{"award-number":["2018_01: 7T MRI of the wrist"]}]},{"DOI":"10.13039\/501100018935","name":"Universit\u00e4tsklinikum Erlangen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018935","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>To analyze regional variations in T2 and T2* relaxation times in wrist joint cartilage and the triangular fibrocartilage complex (TFCC) at 3 and 7\u00a0T and to compare values between field strengths.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Twenty-five healthy controls and 25 patients with chronic wrist pain were examined at 3 and 7\u00a0T on the same day using T2- and T2*-weighted sequences. Six different regions of interest (ROIs) were evaluated for cartilage and 3 ROIs were evaluated at the TFCC based on manual segmentation. Paired\n                      <jats:italic>t<\/jats:italic>\n                      -tests were used to compare T2 and T2* values between field strengths and between different ROIs. Spearman\u2019s rank correlation was calculated to assess correlations between T2 and T2* time values at 3 and 7\u00a0T.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      T2 and T2* time values of the cartilage differed significantly between 3 and 7\u00a0T for all ROIs (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.045), with one exception: at the distal lunate, no significant differences in T2 values were observed between field strengths. T2* values differed significantly between 3 and 7\u00a0T for all ROIs of the TFCC (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.001). Spearman\u2019s rank correlation between 3 and 7\u00a0T ranged from 0.03 to 0.62 for T2 values and from 0.01 to 0.48 for T2* values. T2 and T2* values for cartilage varied across anatomic locations in healthy controls at both 3 and 7\u00a0T.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Quantitative results of T2 and T2* mapping at the wrist differ between field strengths, with poor correlation between 3 and 7\u00a0T. Local variations in cartilage T2 and T2* values are observed in healthy individuals.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Relevance statement<\/jats:title>\n                    <jats:p>T2 and T2* mapping are feasible for compositional imaging of the TFCC and the cartilage at the wrist at both 3 and 7\u00a0T, but the clinical interpretation remains challenging due to differences between field strengths and variations between anatomic locations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key points<\/jats:title>\n                    <jats:p>\u2022Field strength and anatomic locations influence T2 and T2* values at the wrist.<\/jats:p>\n                    <jats:p>\u2022T2 and T2* values have a poor correlation between 3 and 7\u00a0T.<\/jats:p>\n                    <jats:p>\u2022Local reference values are needed for each anatomic location for reliable interpretation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Graphical Abstract<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-023-00394-1","type":"journal-article","created":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T20:02:22Z","timestamp":1702497742000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Variation in cartilage T2 and T2* mapping of the wrist: a comparison between 3- and 7-T MRI"],"prefix":"10.1186","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2897-5411","authenticated-orcid":false,"given":"Rafael","family":"Heiss","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3918-8066","authenticated-orcid":false,"given":"Marc-Andr\u00e9","family":"Weber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eva L.","family":"Balbach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"Hinsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frederik","family":"Geissler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armin M.","family":"Nagel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark E.","family":"Ladd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Arkudas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymund E.","family":"Horch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christine","family":"Gall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Uder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank W.","family":"Roemer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,12,14]]},"reference":[{"key":"394_CR1","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1002\/jmri.25371","volume":"45","author":"C Rehnitz","year":"2017","unstructured":"Rehnitz C, Klaan B, Burkholder I, von Stillfried F, Kauczor HU, Weber MA (2017) Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T(2) mapping at 3T MRI of the wrist: Feasibility and clinical application. J Magn Reson Imaging 45:381\u2013389. https:\/\/doi.org\/10.1002\/jmri.25371","journal-title":"J Magn Reson Imaging"},{"key":"394_CR2","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1002\/jmri.23845","volume":"37","author":"CL Hayter","year":"2013","unstructured":"Hayter CL, Gold SL, Potter HG (2013) Magnetic resonance imaging of the wrist: bone and cartilage injury. J Magn Reson Imaging 37:1005\u20131019. https:\/\/doi.org\/10.1002\/jmri.23845","journal-title":"J Magn Reson Imaging"},{"key":"394_CR3","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.hcl.2005.03.005","volume":"21","author":"L Nagy","year":"2005","unstructured":"Nagy L (2005) Salvage of post-traumatic arthritis following distal radius fracture. Hand Clin 21:489\u2013498. https:\/\/doi.org\/10.1016\/j.hcl.2005.03.005","journal-title":"Hand Clin"},{"key":"394_CR4","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1177\/03635465030310060801","volume":"31","author":"AC Rettig","year":"2003","unstructured":"Rettig AC (2003) Athletic injuries of the wrist and hand. Part I: traumatic injuries of the wrist. Am J Sports Med 31:1038\u20131048. https:\/\/doi.org\/10.1177\/03635465030310060801","journal-title":"Am J Sports Med"},{"key":"394_CR5","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1007\/s00256-014-1852-3","volume":"43","author":"T Hesper","year":"2014","unstructured":"Hesper T, Hosalkar HS, Bittersohl D et al (2014) T2*mapping for articular cartilage assessment: principles, current applications, and future prospects. Skeletal Radiol 43:1429\u20131445. https:\/\/doi.org\/10.1007\/s00256-014-1852-3","journal-title":"Skeletal Radiol"},{"key":"394_CR6","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1007\/s00117-019-0521-x","volume":"59","author":"R Heiss","year":"2019","unstructured":"Heiss R, Janka R, Uder M, Nagel AM, Trattnig S, Roemer FW (2019) Update cartilage imaging of the small joints Focus on high-field MRI. Radiologe 59:732\u2013741. https:\/\/doi.org\/10.1007\/s00117-019-0521-x","journal-title":"Radiologe"},{"key":"394_CR7","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1148\/rg.311105084","volume":"31","author":"MD Crema","year":"2011","unstructured":"Crema MD, Roemer FW, Marra MD et al (2011) Articular cartilage in the knee: current MR imaging techniques and applications in clinical practice and research. Radiographics 31:37\u201361. https:\/\/doi.org\/10.1148\/rg.311105084","journal-title":"Radiographics"},{"key":"394_CR8","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1002\/jmri.23598","volume":"35","author":"RD Newbould","year":"2012","unstructured":"Newbould RD, Miller SR, Toms LD et al (2012) T2* measurement of the knee articular cartilage in osteoarthritis at 3T. J Magn Reson Imaging 35:1422\u20131429. https:\/\/doi.org\/10.1002\/jmri.23598","journal-title":"J Magn Reson Imaging"},{"key":"394_CR9","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1097\/RLI.0b013e3181b4c055","volume":"44","author":"R Krug","year":"2009","unstructured":"Krug R, Stehling C, Kelley DA, Majumdar S, Link TM (2009) Imaging of the musculoskeletal system in vivo using ultra-high field magnetic resonance at 7 T. Invest Radiol 44:613\u2013618. https:\/\/doi.org\/10.1097\/RLI.0b013e3181b4c055","journal-title":"Invest Radiol"},{"key":"394_CR10","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/j.mri.2014.05.010","volume":"32","author":"I Rauscher","year":"2014","unstructured":"Rauscher I, Bender B, Grozinger G et al (2014) Assessment of T1, T1rho, and T2 values of the ulnocarpal disc in healthy subjects at 3 tesla. Magn Reson Imaging 32:1085\u20131090. https:\/\/doi.org\/10.1016\/j.mri.2014.05.010","journal-title":"Magn Reson Imaging"},{"key":"394_CR11","doi-asserted-by":"publisher","unstructured":"Yan M, Wen S, Wang X (2022) Quantitative analysis of triangular fibrocartilage complex injury by 3.0T MR 3D VIBE and T2 mapping techniques. Medicine (Baltimore) 101:e31589. https:\/\/doi.org\/10.1097\/MD.0000000000031589","DOI":"10.1097\/MD.0000000000031589"},{"key":"394_CR12","doi-asserted-by":"publisher","unstructured":"Heiss R, Weber MA, Balbach E et al (2023) Clinical application of ultrahigh-field-strength wrist MRI: a multireader 3-T and 7-T comparison study. Radiology. https:\/\/doi.org\/10.1148\/radiol.220753","DOI":"10.1148\/radiol.220753"},{"key":"394_CR13","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1002\/jmri.22781","volume":"34","author":"OF Donati","year":"2011","unstructured":"Donati OF, Nordmeyer-Massner J, Nanz D et al (2011) Direct MR arthrography of cadaveric wrists: comparison between MR imaging at 3.0T and 7.0T and gross pathologic inspection. J Magn Reson Imaging 34:1333\u20131340. https:\/\/doi.org\/10.1002\/jmri.22781","journal-title":"J Magn Reson Imaging"},{"key":"394_CR14","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1055\/s-0032-1311760","volume":"16","author":"KM Friedrich","year":"2012","unstructured":"Friedrich KM, Komorowski A, Trattnig S (2012) 7T imaging of the wrist. Semin Musculoskelet Radiol 16:88\u201392. https:\/\/doi.org\/10.1055\/s-0032-1311760","journal-title":"Semin Musculoskelet Radiol"},{"key":"394_CR15","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1002\/jmri.22419","volume":"33","author":"JA Nordmeyer-Massner","year":"2011","unstructured":"Nordmeyer-Massner JA, Wyss M, Andreisek G, Pruessmann KP, Hodler J (2011) In vitro and in vivo comparison of wrist MR imaging at 3.0 and 7.0 tesla using a gradient echo sequence and identical eight-channel coil array designs. J Magn Reson Imaging 33:661\u2013667. https:\/\/doi.org\/10.1002\/jmri.22419","journal-title":"J Magn Reson Imaging"},{"key":"394_CR16","doi-asserted-by":"publisher","first-page":"1768","DOI":"10.1002\/nbm.3582","volume":"29","author":"SB Raval","year":"2016","unstructured":"Raval SB, Zhao T, Krishnamurthy N et al (2016) Ultra-high-field RF coil development for evaluating upper extremity imaging applications. NMR Biomed 29:1768\u20131779. https:\/\/doi.org\/10.1002\/nbm.3582","journal-title":"NMR Biomed"},{"key":"394_CR17","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1016\/j.mri.2013.01.009","volume":"31","author":"K Subburaj","year":"2013","unstructured":"Subburaj K, Valentinitsch A, Dillon AB et al (2013) Regional variations in MR relaxation of hip joint cartilage in subjects with and without femoralacetabular impingement. Magn Reson Imaging 31:1129\u20131136. https:\/\/doi.org\/10.1016\/j.mri.2013.01.009","journal-title":"Magn Reson Imaging"},{"key":"394_CR18","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1097\/RLI.0b013e31817e9122","volume":"43","author":"GH Welsch","year":"2008","unstructured":"Welsch GH, Mamisch TC, Hughes T et al (2008) In vivo biochemical 7.0 Tesla magnetic resonance: preliminary results of dGEMRIC, zonal T2, and T2* mapping of articular cartilage. Invest Radiol 43:619\u2013626. https:\/\/doi.org\/10.1097\/RLI.0b013e31817e9122","journal-title":"Invest Radiol"},{"key":"394_CR19","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1007\/s00256-015-2309-z","volume":"45","author":"WC Bae","year":"2016","unstructured":"Bae WC, Ruangchaijatuporn T, Chang EY et al (2016) MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties. Skeletal Radiol 45:447\u2013454. https:\/\/doi.org\/10.1007\/s00256-015-2309-z","journal-title":"Skeletal Radiol"},{"key":"394_CR20","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012","journal-title":"J Chiropr Med"},{"key":"394_CR21","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1055\/s-2004-861764","volume":"8","author":"TJ Mosher","year":"2004","unstructured":"Mosher TJ, Dardzinski BJ (2004) Cartilage MRI T2 relaxation time mapping: overview and applications. Semin Musculoskelet Radiol 8:355\u2013368. https:\/\/doi.org\/10.1055\/s-2004-861764","journal-title":"Semin Musculoskelet Radiol"},{"key":"394_CR22","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1016\/j.joca.2021.10.016","volume":"30","author":"KS Emanuel","year":"2022","unstructured":"Emanuel KS, Kellner LJ, Peters MJM, Haartmans MJJ, Hooijmans MT, Emans PJ (2022) The relation between the biochemical composition of knee articular cartilage and quantitative MRI: a systematic review and meta-analysis. Osteoarthritis Cartilage 30:650\u2013662. https:\/\/doi.org\/10.1016\/j.joca.2021.10.016","journal-title":"Osteoarthritis Cartilage"},{"key":"394_CR23","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1007\/s00330-021-08165-5","volume":"32","author":"S Gotestrand","year":"2022","unstructured":"Gotestrand S, Bjorkman A, Bjorkman-Burtscher IM et al (2022) Visualization of wrist anatomy-a comparison between 7T and 3T MRI. Eur Radiol 32:1362\u20131370. https:\/\/doi.org\/10.1007\/s00330-021-08165-5","journal-title":"Eur Radiol"},{"key":"394_CR24","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1055\/s-0041-1730948","volume":"25","author":"JP Grunz","year":"2021","unstructured":"Grunz JP, Gietzen CH, Christopoulos G et al (2021) Osteoarthritis of the wrist: pathology, radiology, and treatment. Semin Musculoskelet Radiol 25:294\u2013303. https:\/\/doi.org\/10.1055\/s-0041-1730948","journal-title":"Semin Musculoskelet Radiol"},{"key":"394_CR25","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1097\/01.HP.0000343164.27920.4a","volume":"96","author":"International Commission on Non-Ionizing Radiation P","year":"2009","unstructured":"International Commission on Non-Ionizing Radiation P (2009) Guidelines on limits of exposure to static magnetic fields. Health Phys 96:504\u2013514. https:\/\/doi.org\/10.1097\/01.HP.0000343164.27920.4a","journal-title":"Health Phys"},{"key":"394_CR26","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s10334-007-0095-x","volume":"21","author":"JM Theysohn","year":"2008","unstructured":"Theysohn JM, Maderwald S, Kraff O, Moenninghoff C, Ladd ME, Ladd SC (2008) Subjective acceptance of 7 Tesla MRI for human imaging. MAGMA 21:63\u201372. https:\/\/doi.org\/10.1007\/s10334-007-0095-x","journal-title":"MAGMA"},{"key":"394_CR27","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1002\/bem.22189","volume":"40","author":"B Hansson","year":"2019","unstructured":"Hansson B, Hoglund P, Markenroth Bloch K et al (2019) Short-term effects experienced during examinations in an actively shielded 7 T MR. Bioelectromagnetics 40:234\u2013249. https:\/\/doi.org\/10.1002\/bem.22189","journal-title":"Bioelectromagnetics"},{"key":"394_CR28","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1002\/jmri.27139","volume":"52","author":"B Hansson","year":"2020","unstructured":"Hansson B, Markenroth Bloch K, Owman T et al (2020) Subjectively reported effects experienced in an actively shielded 7T MRI: a large-scale study. J Magn Reson Imaging 52:1265\u20131276. https:\/\/doi.org\/10.1002\/jmri.27139","journal-title":"J Magn Reson Imaging"},{"key":"394_CR29","doi-asserted-by":"publisher","first-page":"1675","DOI":"10.1002\/jmri.24748","volume":"41","author":"B Friebe","year":"2015","unstructured":"Friebe B, Wollrab A, Thormann M et al (2015) Sensory perceptions of individuals exposed to the static field of a 7T MRI: a controlled blinded study. J Magn Reson Imaging 41:1675\u20131681. https:\/\/doi.org\/10.1002\/jmri.24748","journal-title":"J Magn Reson Imaging"},{"key":"394_CR30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.pnmrs.2018.06.001","volume":"109","author":"ME Ladd","year":"2018","unstructured":"Ladd ME, Bachert P, Meyerspeer M et al (2018) Pros and cons of ultra-high-field MRI\/MRS for human application. Prog Nucl Magn Reson Spectrosc 109:1\u201350. https:\/\/doi.org\/10.1016\/j.pnmrs.2018.06.001","journal-title":"Prog Nucl Magn Reson Spectrosc"},{"key":"394_CR31","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1007\/s00330-010-2029-7","volume":"21","author":"GH Welsch","year":"2011","unstructured":"Welsch GH, Apprich S, Zbyn S et al (2011) Biochemical (T2, T2* and magnetisation transfer ratio) MRI of knee cartilage: feasibility at ultra-high field (7T) compared with high field (3T) strength. Eur Radiol 21:1136\u20131143. https:\/\/doi.org\/10.1007\/s00330-010-2029-7","journal-title":"Eur Radiol"},{"key":"394_CR32","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1002\/mrm.28109","volume":"84","author":"RP Agt","year":"2020","unstructured":"Agt RP, Neji R, Wood TC, Baburamani AA, Malik SJ, Hajnal JV (2020) Controlled saturation magnetization transfer for reproducible multivendor variable flip angle T(1) and T(2) mapping. Magn Reson Med 84:221\u2013236. https:\/\/doi.org\/10.1002\/mrm.28109","journal-title":"Magn Reson Med"},{"key":"394_CR33","doi-asserted-by":"publisher","first-page":"1565","DOI":"10.1007\/s00256-013-1699-z","volume":"42","author":"ML Pachowsky","year":"2013","unstructured":"Pachowsky ML, Trattnig S, Apprich S, Mauerer A, Zbyn S, Welsch GH (2013) Impact of different coils on biochemical T2 and T2* relaxation time mapping of articular patella cartilage. Skeletal Radiol 42:1565\u20131572. https:\/\/doi.org\/10.1007\/s00256-013-1699-z","journal-title":"Skeletal Radiol"},{"key":"394_CR34","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1002\/jmri.23506","volume":"35","author":"G Chang","year":"2012","unstructured":"Chang G, Wiggins GC, Xia D et al (2012) Comparison of a 28-channel receive array coil and quadrature volume coil for morphologic imaging and T2 mapping of knee cartilage at 7T. J Magn Reson Imaging 35:441\u2013448. https:\/\/doi.org\/10.1002\/jmri.23506","journal-title":"J Magn Reson Imaging"},{"key":"394_CR35","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1002\/jmri.24757","volume":"42","author":"SJ Matzat","year":"2015","unstructured":"Matzat SJ, McWalter EJ, Kogan F, Chen W, Gold GE (2015) T2 Relaxation time quantitation differs between pulse sequences in articular cartilage. J Magn Reson Imaging 42:105\u2013113. https:\/\/doi.org\/10.1002\/jmri.24757","journal-title":"J Magn Reson Imaging"},{"key":"394_CR36","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1002\/jmri.20689","volume":"24","author":"CA McKenzie","year":"2006","unstructured":"McKenzie CA, Williams A, Prasad PV, Burstein D (2006) Three-dimensional delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5T and 3.0T. J Magn Reson Imaging 24:928\u2013933. https:\/\/doi.org\/10.1002\/jmri.20689","journal-title":"J Magn Reson Imaging"},{"key":"394_CR37","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1136\/ard.58.1.27","volume":"58","author":"DE Shepherd","year":"1999","unstructured":"Shepherd DE, Seedhom BB (1999) Thickness of human articular cartilage in joints of the lower limb. Ann Rheum Dis 58:27\u201334. https:\/\/doi.org\/10.1136\/ard.58.1.27","journal-title":"Ann Rheum Dis"},{"key":"394_CR38","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1148\/radiology.214.1.r00ja15259","volume":"214","author":"TJ Mosher","year":"2000","unstructured":"Mosher TJ, Dardzinski BJ, Smith MB (2000) Human articular cartilage: influence of aging and early symptomatic degeneration on the spatial variation of T2\u2013preliminary findings at 3 T. Radiology 214:259\u2013266. https:\/\/doi.org\/10.1148\/radiology.214.1.r00ja15259","journal-title":"Radiology"},{"key":"394_CR39","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.joca.2007.06.003","volume":"16","author":"T Nishii","year":"2008","unstructured":"Nishii T, Tanaka H, Sugano N, Sakai T, Hananouchi T, Yoshikawa H (2008) Evaluation of cartilage matrix disorders by T2 relaxation time in patients with hip dysplasia. Osteoarthritis Cartilage 16:227\u2013233. https:\/\/doi.org\/10.1016\/j.joca.2007.06.003","journal-title":"Osteoarthritis Cartilage"},{"key":"394_CR40","doi-asserted-by":"publisher","first-page":"2022","DOI":"10.1016\/j.joca.2017.01.013","volume":"25","author":"H Shao","year":"2017","unstructured":"Shao H, Pauli C, Li S et al (2017) Magic angle effect plays a major role in both T1rho and T2 relaxation in articular cartilage. Osteoarthritis Cartilage 25:2022\u20132030. https:\/\/doi.org\/10.1016\/j.joca.2017.01.013","journal-title":"Osteoarthritis Cartilage"},{"key":"394_CR41","doi-asserted-by":"publisher","first-page":"665","DOI":"10.2214\/ajr.177.3.1770665","volume":"177","author":"TJ Mosher","year":"2001","unstructured":"Mosher TJ, Smith H, Dardzinski BJ, Schmithorst VJ, Smith MB (2001) MR imaging and T2 mapping of femoral cartilage: in vivo determination of the magic angle effect. AJR Am J Roentgenol 177:665\u2013669. https:\/\/doi.org\/10.2214\/ajr.177.3.1770665","journal-title":"AJR Am J Roentgenol"},{"key":"394_CR42","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1007\/s00256-012-1511-5","volume":"42","author":"S Balamoody","year":"2013","unstructured":"Balamoody S, Williams TG, Wolstenholme C et al (2013) Magnetic resonance transverse relaxation time T2 of knee cartilage in osteoarthritis at 3-T: a cross-sectional multicentre, multivendor reproducibility study. Skeletal Radiol 42:511\u2013520. https:\/\/doi.org\/10.1007\/s00256-012-1511-5","journal-title":"Skeletal Radiol"},{"key":"394_CR43","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.joca.2013.01.006","volume":"21","author":"BJ Dardzinski","year":"2013","unstructured":"Dardzinski BJ, Schneider E (2013) Radiofrequency (RF) coil impacts the value and reproducibility of cartilage spin-spin (T2) relaxation time measurements. Osteoarthritis Cartilage 21:710\u2013720. https:\/\/doi.org\/10.1016\/j.joca.2013.01.006","journal-title":"Osteoarthritis Cartilage"},{"key":"394_CR44","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1016\/j.joca.2020.07.005","volume":"28","author":"J Kim","year":"2020","unstructured":"Kim J, Mamoto K, Lartey R et al (2020) Multi-vendor multi-site T(1rho) and T(2) quantification of knee cartilage. Osteoarthritis Cartilage 28:1539\u20131550. https:\/\/doi.org\/10.1016\/j.joca.2020.07.005","journal-title":"Osteoarthritis Cartilage"},{"key":"394_CR45","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1016\/j.mri.2008.02.017","volume":"26","author":"A Pai","year":"2008","unstructured":"Pai A, Li X, Majumdar S (2008) A comparative study at 3 T of sequence dependence of T2 quantitation in the knee. Magn Reson Imaging 26:1215\u20131220. https:\/\/doi.org\/10.1016\/j.mri.2008.02.017","journal-title":"Magn Reson Imaging"},{"key":"394_CR46","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1148\/radiol.2021204587","volume":"301","author":"M Chalian","year":"2021","unstructured":"Chalian M, Li X, Guermazi A et al (2021) The QIBA Profile for MRI-based Compositional Imaging of Knee Cartilage. Radiology 301:423\u2013432. https:\/\/doi.org\/10.1148\/radiol.2021204587","journal-title":"Radiology"},{"key":"394_CR47","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.221531","volume":"308","author":"D Hayashi","year":"2023","unstructured":"Hayashi D, Roemer FW, Tol JL et al (2023) Emerging quantitative imaging techniques in sports medicine. Radiology 308:e221531. https:\/\/doi.org\/10.1148\/radiol.221531","journal-title":"Radiology"}],"updated-by":[{"DOI":"10.1186\/s41747-024-00449-x","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2024,3,16]],"date-time":"2024-03-16T00:00:00Z","timestamp":1710547200000}}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-023-00394-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-023-00394-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-023-00394-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T10:03:14Z","timestamp":1710410594000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-023-00394-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,14]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["394"],"URL":"https:\/\/doi.org\/10.1186\/s41747-023-00394-1","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,14]]},"assertion":[{"value":"14 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 March 2024","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s41747-024-00449-x","URL":"https:\/\/doi.org\/10.1186\/s41747-024-00449-x","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This single-center study was approved by the local institutional review boards of the Friedrich-Alexander University Erlangen-N\u00fcrnberg (163_13 B) and the University of Rostock (A 2018\u20130126). The study was performed in accordance with the Declaration of Helsinki. Written informed consent was obtained by every participant.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"FWR is the Chief Medical Officer and a shareholder of BICL, LLC. FWR is also a consultant to the California Institute for Biomedical Research (Calibr) and Gr\u00fcnenthal GmbH. The other authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"80"}}