{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:20:42Z","timestamp":1792790442578,"version":"4.5.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T00:00:00Z","timestamp":1704326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T00:00:00Z","timestamp":1704326400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Canon Medical Research USA"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Recent advancements in diagnostic CT detector technology have made it possible to resolve anatomical features smaller than 20 LP\/cm, referred to as ultra-high-resolution (UHR) CT. Subtle biological motions that did not affect standard-resolution (SR) CT may not be neglected in UHR. This study aimed to quantify the cardiac-induced motion of the pancreas and simulate its impact on the image quality of UHR-CT. We measured the displacement of the head of the pancreas in three healthy volunteers using Displacement Encoding with Stimulated Echoes (DENSE) MRI. The results were used to simulate SR- and UHR-CT acquisitions affected by pancreatic motion.<\/jats:p><jats:p>We found pancreatic displacement in the 0.24\u20131.59\u00a0mm range during one cardiac cycle across the subjects. The greatest displacement was observed in the anterior\u2013posterior direction. The time to peak displacement varied across subjects. Both SR and UHR images showed reduced image quality, as measured by radial modulation transfer function, due to cardiac-induced motion, but the motion artifacts caused more severe degradation in UHR acquisitions. Our investigation of cardiac-induced pancreatic displacement reveals its potential to degrade both standard and UHR-CT scans. To fully utilize the improvement in spatial resolution offered by UHR-CT, the effects of cardiac-induced motion in the abdomen need to be understood and corrected.<\/jats:p><jats:p><jats:bold>Relevance statement\u00a0<\/jats:bold>Advancements in CT detector technology have enhanced CT scanner spatial resolution to approximately 100\u00a0\u00b5m. Consequently, previously ignored biological motions such as the cardiac-induced motion of the pancreas now demand attention to fully utilize this improved resolution.<\/jats:p>\n                <jats:p><jats:bold>Graphical Abstract<\/jats:bold><\/jats:p>","DOI":"10.1186\/s41747-023-00401-5","type":"journal-article","created":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T01:02:18Z","timestamp":1704330138000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Cardiac-induced motion of the pancreas and its effect on image quality of ultrahigh-resolution CT"],"prefix":"10.1186","volume":"8","author":[{"given":"Thomas Wesley","family":"Holmes","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhou","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Thompson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John N.","family":"Oshinski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7149-5424","authenticated-orcid":false,"given":"Amir","family":"Pourmorteza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,4]]},"reference":[{"key":"401_CR1","doi-asserted-by":"publisher","first-page":"8579","DOI":"10.1007\/s00330-022-08933-x","volume":"32","author":"LP Liu","year":"2022","unstructured":"Liu LP, Shapira N, Chen AA et al (2022) First-generation clinical dual-source photon-counting CT: ultra-low-dose quantitative spectral imaging. Eur Radiol 32:8579\u20138587. https:\/\/doi.org\/10.1007\/s00330-022-08933-x","journal-title":"Eur Radiol"},{"key":"401_CR2","doi-asserted-by":"publisher","first-page":"e210053","DOI":"10.1148\/ryct.2021210053","volume":"3","author":"J Latina","year":"2021","unstructured":"Latina J, Shabani M, Kapoor K et al (2021) Ultra-high-resolution coronary CT angiography for assessment of patients with severe coronary artery calcification: initial experience. Radiol Cardiothorac Imaging 3:e210053. https:\/\/doi.org\/10.1148\/ryct.2021210053","journal-title":"Radiol Cardiothorac Imaging"},{"key":"401_CR3","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D (2018) Photon-counting CT: technical principles and clinical prospects. Radiology 289:293\u2013312. https:\/\/doi.org\/10.1148\/radiol.2018172656","journal-title":"Radiology"},{"key":"401_CR4","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1097\/RLI.0000000000000463","volume":"53","author":"A Pourmorteza","year":"2018","unstructured":"Pourmorteza A, Symons R, Henning A, Ulzheimer S, Bluemke DA (2018) Dose efficiency of quarter-millimeter photon-counting computed tomography: first-in-human results. Invest Radiol 53:365\u2013372. https:\/\/doi.org\/10.1097\/RLI.0000000000000463","journal-title":"Invest Radiol"},{"key":"401_CR5","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1148\/radiol.211780","volume":"303","author":"SA Si-Mohamed","year":"2022","unstructured":"Si-Mohamed SA, Boccalini S, Lacombe H et al (2022) Coronary CT angiography with photon-counting CT: first-in-human results. Radiology 303:303\u2013313. https:\/\/doi.org\/10.1148\/radiol.211780","journal-title":"Radiology"},{"key":"401_CR6","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s41747-023-00333-0","volume":"7","author":"E Verelst","year":"2023","unstructured":"Verelst E, Buls N, De Mey J et al (2023) Stent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT. Eur Radiol Exp 7:23. https:\/\/doi.org\/10.1186\/s41747-023-00333-0","journal-title":"Eur Radiol Exp"},{"key":"401_CR7","doi-asserted-by":"publisher","first-page":"016001","DOI":"10.1117\/1.JMI.10.1.016001","volume":"10","author":"JF Marsh Jr","year":"2023","unstructured":"Marsh JF Jr, Vercnocke AJ, Rajendran K et al (2023) Measurement of enhanced vasa vasorum density in a porcine carotid model using photon counting detector CT. J Med Imaging (Bellingham) 10:016001. https:\/\/doi.org\/10.1117\/1.JMI.10.1.016001","journal-title":"J Med Imaging (Bellingham)"},{"key":"401_CR8","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1148\/radiol.2020192791","volume":"298","author":"AC Kwan","year":"2021","unstructured":"Kwan AC, Pourmorteza A, Stutman D, Bluemke DA, Lima JAC (2021) Next-generation hardware advances in CT: cardiac applications. Radiology 298:3\u201317. https:\/\/doi.org\/10.1148\/radiol.2020192791","journal-title":"Radiology"},{"key":"401_CR9","doi-asserted-by":"publisher","first-page":"3636","DOI":"10.1038\/s41598-023-30786-7","volume":"13","author":"Y Matsumoto","year":"2023","unstructured":"Matsumoto Y, Fujioka C, Yokomachi K et al (2023) Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT. Sci Rep 13:3636. https:\/\/doi.org\/10.1038\/s41598-023-30786-7","journal-title":"Sci Rep"},{"key":"401_CR10","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1148\/radiol.2021203036","volume":"301","author":"MS Eppelheimer","year":"2021","unstructured":"Eppelheimer MS, Nwotchouang BST, Heidari Pahlavian S et al (2021) Cerebellar and brainstem displacement measured with DENSE MRI in Chiari malformation following posterior fossa decompression surgery. Radiology 301:187\u2013194. https:\/\/doi.org\/10.1148\/radiol.2021203036","journal-title":"Radiology"},{"key":"401_CR11","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1148\/radiol.2303021213","volume":"230","author":"D Kim","year":"2004","unstructured":"Kim D, Gilson WD, Kramer CM, Epstein FH (2004) Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: development and initial evaluation. Radiology 230:862\u2013871. https:\/\/doi.org\/10.1148\/radiol.2303021213","journal-title":"Radiology"},{"key":"401_CR12","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1002\/mrm.28490","volume":"85","author":"BST Nwotchouang","year":"2021","unstructured":"Nwotchouang BST, Eppelheimer MS, Biswas D et al (2021) Accuracy of cardiac-induced brain motion measurement using displacement-encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI): a phantom study. Magn Reson Med 85:1237\u20131247. https:\/\/doi.org\/10.1002\/mrm.28490","journal-title":"Magn Reson Med"},{"key":"401_CR13","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1097\/MPA.0b013e318237457f","volume":"41","author":"AB Syed","year":"2012","unstructured":"Syed AB, Mahal RS, Schumm LP, Dachman AH (2012) Pancreas size and volume on computed tomography in normal adults. Pancreas 41:589\u2013595. https:\/\/doi.org\/10.1097\/MPA.0b013e318237457f","journal-title":"Pancreas"},{"key":"401_CR14","doi-asserted-by":"publisher","first-page":"25129","DOI":"10.1364\/OE.24.025129","volume":"24","author":"W van Aarle","year":"2016","unstructured":"van Aarle W, Palenstijn WJ, Cant J et al (2016) Fast and flexible X-ray tomography using the ASTRA toolbox. Opt Express 24:25129\u201325147. https:\/\/doi.org\/10.1364\/OE.24.025129","journal-title":"Opt Express"},{"key":"401_CR15","doi-asserted-by":"publisher","first-page":"051907","DOI":"10.1118\/1.4800795","volume":"40","author":"SN Friedman","year":"2013","unstructured":"Friedman SN, Fung GS, Siewerdsen JH, Tsui BM (2013) A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom. Med Phys 40:051907. https:\/\/doi.org\/10.1118\/1.4800795","journal-title":"Med Phys"},{"key":"401_CR16","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1148\/radiology.185.3.1438741","volume":"185","author":"DR Enzmann","year":"1992","unstructured":"Enzmann DR, Pelc NJ (1992) Brain motion: measurement with phase-contrast MR imaging. Radiology 185:653\u2013660. https:\/\/doi.org\/10.1148\/radiology.185.3.1438741","journal-title":"Radiology"},{"key":"401_CR17","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1007\/s10439-020-02695-7","volume":"49","author":"BST Nwotchouang","year":"2021","unstructured":"Nwotchouang BST, Eppelheimer MS, Pahlavian SH et al (2021) Regional brain tissue displacement and strain is elevated in subjects with Chiari malformation type I compared to healthy controls: a study using DENSE MRI. Ann Biomed Eng 49:1462\u20131476. https:\/\/doi.org\/10.1007\/s10439-020-02695-7","journal-title":"Ann Biomed Eng"},{"key":"401_CR18","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.1016\/j.athoracsur.2013.06.037","volume":"96","author":"K Karatolios","year":"2013","unstructured":"Karatolios K, Wittek A, Nwe TH et al (2013) Method for aortic wall strain measurement with three-dimensional ultrasound speckle tracking and fitted finite element analysis. Ann Thorac Surg 96:1664\u20131671. https:\/\/doi.org\/10.1016\/j.athoracsur.2013.06.037","journal-title":"Ann Thorac Surg"},{"key":"401_CR19","doi-asserted-by":"publisher","first-page":"2760","DOI":"10.1002\/mp.14789","volume":"48","author":"AM Hernandez","year":"2021","unstructured":"Hernandez AM, Wu P, Mahesh M, Siewerdsen JH, Boone JM (2021) Location and direction dependence in the 3D MTF for a high-resolution CT system. Med Phys 48:2760\u20132771. https:\/\/doi.org\/10.1002\/mp.14789","journal-title":"Med Phys"},{"key":"401_CR20","doi-asserted-by":"publisher","first-page":"1428","DOI":"10.1002\/mp.16124","volume":"50","author":"Z Ahmed","year":"2023","unstructured":"Ahmed Z, Campeau D, Gong H et al (2023) High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT. Med Phys 50:1428\u20131435. https:\/\/doi.org\/10.1002\/mp.16124","journal-title":"Med Phys"},{"key":"401_CR21","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1245\/s10434-021-10662-2","volume":"29","author":"W Zhao","year":"2022","unstructured":"Zhao W, Liu S, Cong L, Zhao Y (2022) Imaging features for predicting high-grade dysplasia or malignancy in branch duct type intraductal papillary mucinous neoplasm of the pancreas: a systematic review and meta-analysis. Ann Surg Oncol 29:1297\u20131312. https:\/\/doi.org\/10.1245\/s10434-021-10662-2","journal-title":"Ann Surg Oncol"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-023-00401-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-023-00401-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-023-00401-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T01:03:13Z","timestamp":1704330193000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-023-00401-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,4]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["401"],"URL":"https:\/\/doi.org\/10.1186\/s41747-023-00401-5","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,4]]},"assertion":[{"value":"14 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This HIPAA-compliant study was approved by the institutional review board at Emory University and all subjects provided written informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All subjects provided written informed consent for their data to be used in publications.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"ZY and RT are employees of Canon Medical Research USA. AP has an active sponsored research agreement with Canon Medical Research USA. Authors who are not employees of or consultants for Canon had control of the inclusion and analysis of data. The other authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"4"}}