{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T12:47:22Z","timestamp":1769518042665,"version":"3.49.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,8,28]],"date-time":"2024-08-28T00:00:00Z","timestamp":1724803200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,28]],"date-time":"2024-08-28T00:00:00Z","timestamp":1724803200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:sec>\n                <jats:title>Abstract<\/jats:title>\n                <jats:p>Electromagnetic tracking of endovascular instruments has the potential to substantially decrease radiation exposure of patients and personnel. In this study, we evaluated the <jats:italic>in vivo<\/jats:italic> accuracy of a vessel-based method to register preoperative computed tomography angiography (CTA) images to physical coordinates using an electromagnetically tracked guidewire. Centerlines of the aortoiliac arteries were extracted from preoperative CTA acquired from five swine. Intravascular positions were obtained from an electromagnetically tracked guidewire. An iterative-closest-point algorithm registered the position data to the preoperative image centerlines. To evaluate the registration accuracy, a guidewire was placed inside the superior mesenteric, left and right renal arteries under fluoroscopic guidance. Position data was acquired with electromagnetic tracking as the guidewire was pulled into the aorta. The resulting measured positions were compared to the corresponding ostia manually identified in the CTA images after applying the registration. The three-dimensional (3D) Euclidean distances were calculated between each corresponding ostial point, and the root mean square (RMS) was calculated for each registration. The median 3D RMS for all registrations was 4.82\u2009mm, with an interquartile range of 3.53\u20136.14\u2009mm. A vessel-based registration of CTA images to vascular anatomy is possible with acceptable accuracy and encourages further clinical testing.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Relevance statement<\/jats:title>\n                <jats:p>This study shows that the centerline algorithm can be used to register preoperative CTA images to vascular anatomy, with the potential to further reduce ionizing radiation exposure during vascular procedures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Key Points<\/jats:title>\n                <jats:p><jats:list list-type=\"bullet\">\n                  <jats:list-item>\n                    <jats:p>Preoperative images can be used to guide the procedure without ionizing intraoperative imaging.<\/jats:p>\n                  <\/jats:list-item>\n                  <jats:list-item>\n                    <jats:p>Preoperative imaging can be the only imaging modality used for guidance of vascular procedures.<\/jats:p>\n                  <\/jats:list-item>\n                  <jats:list-item>\n                    <jats:p>No need to use external fiducial markers to register\/match images and spatial anatomy.<\/jats:p>\n                  <\/jats:list-item>\n                  <jats:list-item>\n                    <jats:p>Acceptable accuracy can be achieved for navigation in a preclinical setting.<\/jats:p>\n                  <\/jats:list-item>\n                <\/jats:list><\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Graphical Abstract<\/jats:title>\n                \n              <\/jats:sec>","DOI":"10.1186\/s41747-024-00499-1","type":"journal-article","created":{"date-parts":[[2024,8,28]],"date-time":"2024-08-28T09:03:55Z","timestamp":1724835835000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Vessel-based CTA-image to spatial anatomy registration using tracked catheter position data: preclinical evaluation of in vivo accuracy"],"prefix":"10.1186","volume":"8","author":[{"given":"Geir Arne","family":"Tangen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Petter","family":"Aadahl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toril A. N.","family":"Hernes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4899-0248","authenticated-orcid":false,"given":"Frode","family":"Manstad-Hulaas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,8,28]]},"reference":[{"key":"499_CR1","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.ejvs.2015.01.014","volume":"50","author":"A Hertault","year":"2015","unstructured":"Hertault A, Maurel B, Midulla M et al (2015) Editor\u2019s Choice\u2014Minimizing radiation exposure during endovascular procedures: basic knowledge, literature review, and reporting standards. Eur J Vasc Endovasc Surg 50:21\u201336. https:\/\/doi.org\/10.1016\/j.ejvs.2015.01.014","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"499_CR2","doi-asserted-by":"publisher","first-page":"5768","DOI":"10.1118\/1.4747343","volume":"39","author":"GC Kagadis","year":"2012","unstructured":"Kagadis GC, Katsanos K, Karnabatidis D, Loudos G, Nikiforidis GC, Hendee WR (2012) Emerging technologies for image guidance and device navigation in interventional radiology. Med Phys 39:5768\u20135781. https:\/\/doi.org\/10.1118\/1.4747343","journal-title":"Med Phys"},{"key":"499_CR3","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1177\/1526602817708196","volume":"4","author":"SR Goudeketting","year":"2017","unstructured":"Goudeketting SR, Heinen SGH, \u00dcnl\u00fc \u00c7 et al (2017) Pros and cons of 3D image fusion in endovascular aortic repair: a systematic review and meta-analysis. J Endovasc Ther 4:595\u2013603. https:\/\/doi.org\/10.1177\/1526602817708196","journal-title":"J Endovasc Ther"},{"key":"499_CR4","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1109\/tpami.1987.4767965","volume":"9","author":"KS Arun","year":"1987","unstructured":"Arun KS, Huang TS, Blostein SD (1987) Least-squares fitting of two 3-D point sets. IEEE Trans Pattern Anal Mach Intell 9:698\u2013700. https:\/\/doi.org\/10.1109\/tpami.1987.4767965","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"499_CR5","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1177\/1526602820960444","volume":"28","author":"SAN Doelare","year":"2021","unstructured":"Doelare SAN, Smorenburg SPM, van Schaik TG et al (2021) Image fusion during standard and complex endovascular aortic repair, to fuse or not to fuse? A meta-analysis and additional data from a single-center retrospective cohort. J Endovasc Ther 28:78\u201392. https:\/\/doi.org\/10.1177\/1526602820960444","journal-title":"J Endovasc Ther"},{"key":"499_CR6","doi-asserted-by":"publisher","first-page":"S523","DOI":"10.1016\/j.jvir.2009.04.059","volume":"20","author":"MJ Wallace","year":"2009","unstructured":"Wallace MJ, Kuo MD, Glaiberman C, Binkert CA, Orth RC, Soules G (2009) Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol 20:S523\u2013S537. https:\/\/doi.org\/10.1016\/j.jvir.2009.04.059","journal-title":"J Vasc Interv Radiol"},{"key":"499_CR7","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1016\/j.ejvs.2013.12.022","volume":"47","author":"AM Sailer","year":"2014","unstructured":"Sailer AM, de Haan MW, Peppelenbosch AG, Jacobs MJ, Wildberger JE, Schurink GWH (2014) CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg 47:349\u2013356. https:\/\/doi.org\/10.1016\/j.ejvs.2013.12.022","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"499_CR8","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1177\/1526602815605325","volume":"22","author":"AM Sailer","year":"2015","unstructured":"Sailer AM, Wagemann JM (2015) Quantification of respiratory movement of the aorta and side branches. J Endovasc Ther 22:905\u2013911. https:\/\/doi.org\/10.1177\/1526602815605325","journal-title":"J Endovasc Ther"},{"key":"499_CR9","doi-asserted-by":"publisher","first-page":"3945","DOI":"10.21037\/qims-20-1077","volume":"11","author":"MM Jansen","year":"2021","unstructured":"Jansen MM, van der Stelt M, Smorenburg SPM, Slump CH, van Herwaarden JA, Hazenberg CEVB (2021) Target vessel displacement during fenestrated and branched endovascular aortic repair and its implications for the role of traditional computed tomography angiography roadmaps. Quant Imaging Med Surg 11:3945\u20133955. https:\/\/doi.org\/10.21037\/qims-20-1077","journal-title":"Quant Imaging Med Surg"},{"key":"499_CR10","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ejvs.2013.10.001","volume":"47","author":"S Condino","year":"2014","unstructured":"Condino S, Calabr\u00f2 EM, Alberti A et al (2014) Simultaneous tracking of catheters and guidewires: comparison to standard fluoroscopic guidance for arterial cannulation. Eur J Vasc Endovasc Surg 47:53\u201360. https:\/\/doi.org\/10.1016\/j.ejvs.2013.10.001","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"499_CR11","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1080\/13645706.2019.1575240","volume":"28","author":"E Nypan","year":"2019","unstructured":"Nypan E, Tangen GA, Manstad-Hulaas F, Brekken R (2019) Vessel-based rigid registration for endovascular therapy of the abdominal aorta. Minim Invasive Ther Allied Technol 28:127\u2013133. https:\/\/doi.org\/10.1080\/13645706.2019.1575240","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"499_CR12","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1016\/j.ejvs.2012.03.007","volume":"43","author":"A de Lambert","year":"2012","unstructured":"de Lambert A, Esneault S, Lucas A, Haigron P, Cinquin P, Magne JL (2012) Electromagnetic tracking for registration and navigation in endovascular aneurysm repair: a phantom study. Eur J Vasc Endovasc Surg 43:684\u2013689. https:\/\/doi.org\/10.1016\/j.ejvs.2012.03.007","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"499_CR13","doi-asserted-by":"publisher","first-page":"041903","DOI":"10.1118\/1.4866884","volume":"41","author":"EF Hofstad","year":"2014","unstructured":"Hofstad EF, Sorger H, Leira HO, Amundsen T, Lang\u00f8 T (2014) Automatic registration of CT images to patient during the initial phase of bronchoscopy: a clinical pilot study. Med Phys 41:041903\u2013041912. https:\/\/doi.org\/10.1118\/1.4866884","journal-title":"Med Phys"},{"key":"499_CR14","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","volume":"31","author":"PA Yushkevich","year":"2006","unstructured":"Yushkevich PA, Piven J, Hazlett HC et al (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31:1116\u20131128. https:\/\/doi.org\/10.1016\/j.neuroimage.2006.01.015","journal-title":"Neuroimage"},{"key":"499_CR15","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1007\/s11517-008-0420-1","volume":"46","author":"L Antiga","year":"2008","unstructured":"Antiga L, Piccinelli M, Botti L, Ene-Iordache B, Remuzzi A, Steinman DA (2008) An image-based modeling framework for patient-specific computational hemodynamics. Med Bio Eng Comput 46:1097\u20131112. https:\/\/doi.org\/10.1007\/s11517-008-0420-1","journal-title":"Med Bio Eng Comput"},{"key":"499_CR16","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1007\/s11548-015-1292-0","volume":"11","author":"C Askeland","year":"2016","unstructured":"Askeland C, Solberg OV, Bakeng JBL et al (2016) CustusX: an open-source research platform for image-guided therapy. Int J Comput Assist Radiol Surg 11:505\u2013519. https:\/\/doi.org\/10.1007\/s11548-015-1292-0","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"499_CR17","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1109\/34.121791","volume":"14","author":"PJ Besl","year":"1992","unstructured":"Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14:239\u2013256. https:\/\/doi.org\/10.1109\/34.121791","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"499_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fninf.2014.00013\/abstract","volume":"8","author":"M McCormick","year":"2014","unstructured":"McCormick M, Liu X, Jomier J, Marion C, Ibanez L (2014) ITK: enabling reproducible research and open science. Front Neuroinform 8:1\u201311. https:\/\/doi.org\/10.3389\/fninf.2014.00013\/abstract","journal-title":"Front Neuroinform"},{"key":"499_CR19","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1583\/10-3301.1","volume":"18","author":"F Manstad-Hulaas","year":"2011","unstructured":"Manstad-Hulaas F, Tangen GA, Gruionu LG, Aadahl P, Hernes TAN (2011) Three-dimensional endovascular navigation with electromagnetic tracking: ex vivo and in vivo accuracy. J Endovasc Ther 18:230\u2013240. https:\/\/doi.org\/10.1583\/10-3301.1","journal-title":"J Endovasc Ther"},{"key":"499_CR20","doi-asserted-by":"publisher","first-page":"2145","DOI":"10.1002\/mp.14825","volume":"48","author":"OV Ivashchenko","year":"2021","unstructured":"Ivashchenko OV, Kuhlmann KFD, van Veen R et al (2021) CBCT-based navigation system for open liver surgery: accurate guidance toward mobile and deformable targets with a semi-rigid organ approximation and electromagnetic tracking of the liver. Med Phys 48:2145\u20132159. https:\/\/doi.org\/10.1002\/mp.14825","journal-title":"Med Phys"},{"key":"499_CR21","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1016\/j.media.2007.04.002","volume":"11","author":"I Reinertsen","year":"2007","unstructured":"Reinertsen I, Descoteaux M, Siddiqi K, Collins DL (2007) Validation of vessel-based registration for correction of brain shift. Med Image Anal 11:374\u2013388. https:\/\/doi.org\/10.1016\/j.media.2007.04.002","journal-title":"Med Image Anal"},{"key":"499_CR22","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1109\/tvcg.2012.310","volume":"19","author":"GKL Tam","year":"2012","unstructured":"Tam GKL, Cheng Z-Q, Lai Y-K et al (2012) Registration of 3D point clouds and meshes: a survey from rigid to nonrigid. IEEE Trans Vis Comput Graph 19:1199\u20131217. https:\/\/doi.org\/10.1109\/tvcg.2012.310","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"499_CR23","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.1007\/s11548-019-02059-0","volume":"14","author":"S J\u00e4ckle","year":"2019","unstructured":"J\u00e4ckle S, Eixmann T, Schulz-Hildebrandt H, H\u00fcttmann G, P\u00e4tz T (2019) Fiber optical shape sensing of flexible instruments for endovascular navigation. Int J Comput Assist Radiol Surg 14:2137\u20132145. https:\/\/doi.org\/10.1007\/s11548-019-02059-0","journal-title":"Int J Comput Assist Radiol Surg"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-024-00499-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-024-00499-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-024-00499-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,28]],"date-time":"2024-08-28T09:11:08Z","timestamp":1724836268000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-024-00499-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,28]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["499"],"URL":"https:\/\/doi.org\/10.1186\/s41747-024-00499-1","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,28]]},"assertion":[{"value":"13 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Institutional Animal Care and Use Committee of March 3, 2017, approved the study (17\/28188-1), and all animals were treated according to the Guide for the Care and Use of Laboratory Animals.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"GAT is affiliated with SINTEF Digital. The remaining authors have no financial or non-financial competing interests to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"99"}}