{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T06:37:34Z","timestamp":1787899054570,"version":"build-2784847793"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T00:00:00Z","timestamp":1738108800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T00:00:00Z","timestamp":1738108800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Minimizing radiation exposure is crucial in monitoring adolescent idiopathic scoliosis (AIS). Generative adversarial networks (GANs) have emerged as valuable tools being able to generate high-quality synthetic images. This study explores the use of GANs to generate synthetic sagittal radiographs from coronal views in AIS patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A dataset of 3,935 AIS patients who underwent spine and pelvis radiographic examinations using the EOS system, which simultaneously acquires coronal and sagittal images, was analyzed. The dataset was divided into training-set (85%,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20093,356) and test-set (15%,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009579). GAN model was trained to generate sagittal images from coronal views, with real sagittal views as reference standard. To assess accuracy, 100 subjects from the test-set were randomly selected for manual measurement of lumbar lordosis (LL), sacral slope (SS), pelvic incidence (PI), and sagittal vertical axis (SVA) by two radiologists in both synthetic and real images.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Sixty-nine synthetic images were considered assessable. The intraclass correlation coefficient ranged 0.93\u20130.99 for measurements in real images, and from 0.83 to 0.88 for synthetic images. Correlations between parameters of real and synthetic images were 0.52 (LL), 0.17 (SS), 0.18 (PI), and 0.74 (SVA). Measurement errors showed minimal correlation with scoliosis severity. Mean\u2009\u00b1\u2009standard deviation absolute errors were 7\u2009\u00b1\u20097\u00b0 (LL), 9\u2009\u00b1\u20097\u00b0 (SS), 9\u2009\u00b1\u20098\u00b0 (PI), and 1.1\u2009\u00b1\u20090.8\u2009cm (SVA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>While the model generates sagittal images visually consistent with reference images, their quality is not sufficient for clinical parameter assessment, except for promising results in SVA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Relevance statement<\/jats:title>\n                    <jats:p>AI can generate synthetic sagittal radiographs from coronal views to reduce radiation exposure in monitoring adolescent idiopathic scoliosis (AIS). However, while these synthetic images appear visually consistent with real ones, their quality remains insufficient for accurate clinical assessment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>AI can be exploited to generate synthetic sagittal radiographs from coronal views.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Dataset of 3,935 subjects was used to train and test AI-model; spinal parameters from synthetic and real images were compared.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Synthetic images were visually consistent with real ones, but quality was generally insufficient for accurate clinical assessment.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Graphical Abstract<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-025-00553-6","type":"journal-article","created":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T13:14:04Z","timestamp":1738156444000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Feasibility of generating sagittal radiographs from coronal views using GAN-based deep learning framework in adolescent idiopathic scoliosis"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3312-1565","authenticated-orcid":false,"given":"Tito","family":"Bassani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Cina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio","family":"Galbusera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Cazzato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Elena","family":"Pellegrino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico","family":"Albano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca Maria","family":"Sconfienza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,29]]},"reference":[{"key":"553_CR1","doi-asserted-by":"publisher","first-page":"1527","DOI":"10.1016\/S0140-6736(08)60658-3","volume":"371","author":"SL Weinstein","year":"2008","unstructured":"Weinstein SL, Dolan LA, Cheng JC, Danielsson A, Morcuende JA (2008) Adolescent idiopathic scoliosis. Lancet 371:1527\u20131537. https:\/\/doi.org\/10.1016\/S0140-6736(08)60658-3","journal-title":"Lancet"},{"key":"553_CR2","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.paed.2009.11.009","volume":"20","author":"C Nnadi","year":"2010","unstructured":"Nnadi C, Fairbank J (2010) Scoliosis: a review. Paediatrics Child Health 20:215\u2013220. https:\/\/doi.org\/10.1016\/j.paed.2009.11.009","journal-title":"Paediatrics Child Health"},{"key":"553_CR3","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1007\/s00256-013-1600-0","volume":"42","author":"TJ Dietrich","year":"2013","unstructured":"Dietrich TJ, Pfirrmann CW, Schwab A, Pankalla K, Buck FM (2013) Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography. Skelet Radiol 42:959\u2013967. https:\/\/doi.org\/10.1007\/s00256-013-1600-0","journal-title":"Skelet Radiol"},{"key":"553_CR4","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1016\/j.spinee.2012.10.002","volume":"12","author":"S Somoskeoy","year":"2012","unstructured":"Somoskeoy S, Tunyogi-Csapo M, Bogyo C, Illes T (2012) Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D\/3D imaging system. Spine J 12:1052\u20131059. https:\/\/doi.org\/10.1016\/j.spinee.2012.10.002","journal-title":"Spine J"},{"key":"553_CR5","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1007\/s00264-012-1512-y","volume":"36","author":"T Illes","year":"2012","unstructured":"Illes T, Somoskeoy S (2012) The EOS imaging system and its uses in daily orthopaedic practice. Int Orthop 36:1325\u20131331. https:\/\/doi.org\/10.1007\/s00264-012-1512-y","journal-title":"Int Orthop"},{"key":"553_CR6","doi-asserted-by":"publisher","unstructured":"Negrini S, Donzelli S, Aulisa AG et al (2018) 2016 SOSORT guidelines: Orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth. Scoliosis Spinal Disord 13:3\u20138. https:\/\/doi.org\/10.1186\/s13013-017-0145-8. eCollection 2018","DOI":"10.1186\/s13013-017-0145-8"},{"key":"553_CR7","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1007\/s11547-024-01832-9","volume":"129","author":"R Tomaiuolo","year":"2024","unstructured":"Tomaiuolo R, Banfi G, Messina C, Albano D, Gitto S, Sconfienza LM (2024) Health technology assessment in musculoskeletal radiology: the case study of EOSedge\u2122. Radiol Med 129:1076\u20131085. https:\/\/doi.org\/10.1007\/s11547-024-01832-9","journal-title":"Radiol Med"},{"key":"553_CR8","doi-asserted-by":"publisher","DOI":"10.1002\/jsp2.1044","volume":"2","author":"F Galbusera","year":"2019","unstructured":"Galbusera F, Casaroli G, Bassani T (2019) Artificial intelligence and machine learning in spine research. JOR Spine 2:e1044. https:\/\/doi.org\/10.1002\/jsp2.1044","journal-title":"JOR Spine"},{"key":"553_CR9","doi-asserted-by":"publisher","first-page":"2057","DOI":"10.1007\/s00586-022-07176-0","volume":"31","author":"AL Hornung","year":"2022","unstructured":"Hornung AL, Hornung CM, Mallow GM et al (2022) Artificial intelligence in spine care: current applications and future utility. Eur Spine J 31:2057\u20132081. https:\/\/doi.org\/10.1007\/s00586-022-07176-0","journal-title":"Eur Spine J"},{"key":"553_CR10","doi-asserted-by":"publisher","DOI":"10.3389\/fradi.2021.781868","volume":"1","author":"S Wang","year":"2021","unstructured":"Wang S, Cao G, Wang Y et al (2021) Review and prospect: Artificial intelligence in advanced medical imaging. Front Radiol 1:781868. https:\/\/doi.org\/10.3389\/fradi.2021.781868","journal-title":"Front Radiol"},{"key":"553_CR11","doi-asserted-by":"publisher","DOI":"10.1093\/bjrai\/ubae007","volume":"1","author":"E Sizikova","year":"2024","unstructured":"Sizikova E, Badal A, Delfino JG et al (2024) Synthetic data in radiological imaging: current state and future outlook. BJR Artif Intell 1:ubae007. https:\/\/doi.org\/10.1093\/bjrai\/ubae007","journal-title":"BJR Artif Intell"},{"key":"553_CR12","doi-asserted-by":"publisher","first-page":"959","DOI":"10.3348\/kjr.2024.0392","volume":"25","author":"HK Jung","year":"2024","unstructured":"Jung HK, Kim K, Park JE, Kim N (2024) Image-based generative artificial intelligence in radiology: comprehensive updates. Korean J Radiol 25:959\u2013981. https:\/\/doi.org\/10.3348\/kjr.2024.0392","journal-title":"Korean J Radiol"},{"key":"553_CR13","doi-asserted-by":"publisher","first-page":"10.1088\/1361","DOI":"10.1088\/1361-6560\/acba74","volume":"68","author":"J Chen","year":"2023","unstructured":"Chen J, Chen S, Wee L, Dekker A, Bermejo I (2023) Deep learning based unpaired image-to-image translation applications for medical physics: a systematic review. Phys Med Biol. https:\/\/doi.org\/10.1088\/1361-6560\/acba74","journal-title":"Phys Med Biol"},{"key":"553_CR14","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.232471","volume":"312","author":"LR Koetzier","year":"2024","unstructured":"Koetzier LR, Wu J, Mastrodicasa D et al (2024) Generating synthetic data for medical imaging. Radiology 312:e232471. https:\/\/doi.org\/10.1148\/radiol.232471","journal-title":"Radiology"},{"key":"553_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2021.104763","volume":"136","author":"A Abu-Srhan","year":"2021","unstructured":"Abu-Srhan A, Almallahi I, Abushariah MAM, Mahafza W, Al-Kadi OS (2021) Paired-unpaired unsupervised attention guided GAN with transfer learning for bidirectional brain MR-CT synthesis. Comput Biol Med 136:104763. https:\/\/doi.org\/10.1016\/j.compbiomed.2021.104763","journal-title":"Comput Biol Med"},{"key":"553_CR16","doi-asserted-by":"publisher","first-page":"2538","DOI":"10.1002\/mp.16847","volume":"51","author":"S Pan","year":"2024","unstructured":"Pan S, Abouei E, Wynne J et al (2024) Synthetic CT generation from MRI using 3D transformer-based denoising diffusion model. Med Phys 51:2538\u20132548. https:\/\/doi.org\/10.1002\/mp.16847","journal-title":"Med Phys"},{"key":"553_CR17","unstructured":"Xie T, Cao C, Cui Z et al (2023) Brain PET synthesis from MRI using joint probability distribution of diffusion model at ultrahigh fields. https:\/\/arxiv.org\/abs\/2211.08901"},{"key":"553_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14499","volume":"25","author":"MA Bahloul","year":"2024","unstructured":"Bahloul MA, Jabeen S, Benoumhani S, Alsaleh HA, Belkhatir Z, Al-Wabil A (2024) Advancements in synthetic CT generation from MRI: a review of techniques, and trends in radiation therapy planning. J Appl Clin Med Phys 25:e14499. https:\/\/doi.org\/10.1002\/acm2.14499","journal-title":"J Appl Clin Med Phys"},{"key":"553_CR19","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2024.1383773","volume":"15","author":"AS Fard","year":"2024","unstructured":"Fard AS, Reutens DC, Ramsay SC, Goodman SJ, Ghosh S, Vegh V (2024) Image synthesis of interictal SPECT from MRI and PET using machine learning. Front Neurol 15:1383773. https:\/\/doi.org\/10.3389\/fneur.2024.1383773","journal-title":"Front Neurol"},{"key":"553_CR20","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2021.646013","volume":"15","author":"W Lin","year":"2021","unstructured":"Lin W, Lin W, Chen G et al (2021) Bidirectional mapping of brain MRI and PET with 3D reversible GAN for the diagnosis of Alzheimer\u2019s disease. Front Neurosci 15:646013. https:\/\/doi.org\/10.3389\/fnins.2021.646013","journal-title":"Front Neurosci"},{"key":"553_CR21","doi-asserted-by":"publisher","unstructured":"Liu X, Xing F, Fakhri GE, Woo J (2021) A unified conditional disentanglement framework for multimodal brain mr image translation. Proc IEEE Int Symp Biomed Imaging 2021. https:\/\/doi.org\/10.1109\/isbi48211.2021.9433897","DOI":"10.1109\/isbi48211.2021.9433897"},{"key":"553_CR22","doi-asserted-by":"publisher","first-page":"35","DOI":"10.5603\/RPOR.a2021.0005","volume":"26","author":"D Kawahara","year":"2021","unstructured":"Kawahara D, Nagata Y (2021) T1-weighted and T2-weighted MRI image synthesis with convolutional generative adversarial networks. Rep Pract Oncol Radiother 26:35\u201342. https:\/\/doi.org\/10.5603\/RPOR.a2021.0005","journal-title":"Rep Pract Oncol Radiother"},{"key":"553_CR23","doi-asserted-by":"publisher","first-page":"53","DOI":"10.3389\/fbioe.2018.00053","volume":"6","author":"F Galbusera","year":"2018","unstructured":"Galbusera F, Niemeyer F, Seyfried M et al (2018) Exploring the potential of generative adversarial networks for synthesizing radiological images of the spine to be used in in silico trials. Front Bioeng Biotechnol 6:53. https:\/\/doi.org\/10.3389\/fbioe.2018.00053","journal-title":"Front Bioeng Biotechnol"},{"key":"553_CR24","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s41747-018-0060-7","volume":"2","author":"F Galbusera","year":"2018","unstructured":"Galbusera F, Bassani T, Casaroli G et al (2018) Generative models: an upcoming innovation in musculoskeletal radiology? A preliminary test in spine imaging. Eur Radiol Exp 2:29\u20137. https:\/\/doi.org\/10.1186\/s41747-018-0060-7","journal-title":"Eur Radiol Exp"},{"key":"553_CR25","doi-asserted-by":"publisher","first-page":"530","DOI":"10.3390\/diagnostics12020530","volume":"12","author":"K Hong","year":"2022","unstructured":"Hong K, Cho Y, Kang CH et al (2022) Lumbar spine computed tomography to magnetic resonance imaging synthesis using generative adversarial network: visual turing test. Diagnostics (Basel) 12:530. https:\/\/doi.org\/10.3390\/diagnostics12020530","journal-title":"Diagnostics"},{"key":"553_CR26","doi-asserted-by":"publisher","first-page":"1602","DOI":"10.1016\/j.spinee.2023.06.399","volume":"23","author":"M Roberts","year":"2023","unstructured":"Roberts M, Hinton G, Wells AJ et al (2023) Imaging evaluation of a proposed 3D generative model for MRI to CT translation in the lumbar spine. Spine J 23:1602\u20131612. https:\/\/doi.org\/10.1016\/j.spinee.2023.06.399","journal-title":"Spine J"},{"key":"553_CR27","doi-asserted-by":"crossref","unstructured":"Singh NK, Raza K (2021) Medical image generation using generative adversarial networks: A review. In: Patgiri R, Biswas A, Roy P (eds). Health informatics: a computational perspective in healthcare. Springer Singapore, Singapore, pp. 77\u201396","DOI":"10.1007\/978-981-15-9735-0_5"},{"key":"553_CR28","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.inffus.2022.10.017","volume":"91","author":"T Zhou","year":"2023","unstructured":"Zhou T, Li Q, Lu H, Cheng Q, Zhang X (2023) GAN review: models and medical image fusion applications. Inf Fusion 91:134\u2013148. https:\/\/doi.org\/10.1016\/j.inffus.2022.10.017","journal-title":"Inf Fusion"},{"key":"553_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2019.101684","volume":"79","author":"K Armanious","year":"2020","unstructured":"Armanious K, Jiang C, Fischer M et al (2020) MedGAN: medical image translation using GANs. Comput Med Imaging Graph 79:101684. https:\/\/doi.org\/10.1016\/j.compmedimag.2019.101684","journal-title":"Comput Med Imaging Graph"},{"key":"553_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102846","volume":"88","author":"A Kazerouni","year":"2023","unstructured":"Kazerouni A, Aghdam EK, Heidari M et al (2023) Diffusion models in medical imaging: a comprehensive survey. Med Image Anal 88:102846. https:\/\/doi.org\/10.1016\/j.media.2023.102846","journal-title":"Med Image Anal"},{"key":"553_CR31","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.3390\/bioengineering10111258","volume":"10","author":"ALY Hung","year":"2023","unstructured":"Hung ALY, Zhao K, Zheng H et al (2023) Med-cDiff: conditional medical image generation with diffusion models. Bioengineering (Basel) 10:1258. https:\/\/doi.org\/10.3390\/bioengineering10111258","journal-title":"Bioeng"},{"key":"553_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2024.103300","volume":"98","author":"Y Zhou","year":"2024","unstructured":"Zhou Y, Chen T, Hou J et al (2024) Cascaded multi-path shortcut diffusion model for medical image translation. Med Image Anal 98:103300. https:\/\/doi.org\/10.1016\/j.media.2024.103300","journal-title":"Med Image Anal"},{"key":"553_CR33","unstructured":"Rais K, Amroune M, Benmachiche A, Haouam MY (2024) Exploring variational autoencoders for medical image generation: a comprehensive study. https:\/\/arxiv.org\/abs\/2411.07348"},{"key":"553_CR34","doi-asserted-by":"crossref","unstructured":"Ehrhardt J, Wilms M (2022) Chapter 8\u2014autoencoders and variational autoencoders in medical image analysis. In: Burgos N, Svoboda D (eds). Biomedical image synthesis and simulation. Academic Press, pp. 129\u2013162","DOI":"10.1016\/B978-0-12-824349-7.00015-3"},{"key":"553_CR35","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102802","volume":"88","author":"F Shamshad","year":"2023","unstructured":"Shamshad F, Khan S, Zamir SW et al (2023) Transformers in medical imaging: a survey. Med Image Anal 88:102802. https:\/\/doi.org\/10.1016\/j.media.2023.102802","journal-title":"Med Image Anal"},{"key":"553_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102762","volume":"85","author":"J Li","year":"2023","unstructured":"Li J, Chen J, Tang Y, Wang C, Landman BA, Zhou SK (2023) Transforming medical imaging with transformers? A comparative review of key properties, current progresses, and future perspectives. Med Image Anal 85:102762. https:\/\/doi.org\/10.1016\/j.media.2023.102762","journal-title":"Med Image Anal"},{"key":"553_CR37","doi-asserted-by":"publisher","first-page":"1756","DOI":"10.3390\/diagnostics14161756","volume":"14","author":"JT Yoon","year":"2024","unstructured":"Yoon JT, Lee KM, Oh J, Kim H, Jeong JW (2024) Insights and considerations in development and performance evaluation of generative adversarial networks (GANs): what radiologists need to know. Diagnostics (Basel) 14:1756. https:\/\/doi.org\/10.3390\/diagnostics14161756","journal-title":"Diagnostics"},{"key":"553_CR38","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/s12938-024-01280-6","volume":"23","author":"S Abbasi","year":"2024","unstructured":"Abbasi S, Lan H, Choupan J, Sheikh-Bahaei N, Pandey G, Varghese B (2024) Deep learning for the harmonization of structural MRI scans: a survey. Biomed Eng Online 23:90\u201396. https:\/\/doi.org\/10.1186\/s12938-024-01280-6","journal-title":"Biomed Eng Online"},{"key":"553_CR39","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1016\/j.jacr.2019.05.040","volume":"16","author":"BL Vey","year":"2019","unstructured":"Vey BL, Gichoya JW, Prater A, Hawkins CM (2019) The role of generative adversarial networks in radiation reduction and artifact correction in medical imaging. J Am Coll Radiol 16:1273\u20131278. https:\/\/doi.org\/10.1016\/j.jacr.2019.05.040","journal-title":"J Am Coll Radiol"},{"key":"553_CR40","doi-asserted-by":"publisher","first-page":"821","DOI":"10.21037\/atm-20-6325","volume":"9","author":"K Koshino","year":"2021","unstructured":"Koshino K, Werner RA, Pomper MG et al (2021) Narrative review of generative adversarial networks in medical and molecular imaging. Ann Transl Med 9:821\u20136325. https:\/\/doi.org\/10.21037\/atm-20-6325","journal-title":"Ann Transl Med"},{"key":"553_CR41","doi-asserted-by":"publisher","unstructured":"Han C, Hayashi H, Rundo L et al (2018) GAN-based synthetic brain MR image generation. 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018):734\u2013738. https:\/\/doi.org\/10.1109\/ISBI.2018.8363678","DOI":"10.1109\/ISBI.2018.8363678"},{"key":"553_CR42","unstructured":"Isola P, Zhu J, Zhou T, Efros AA (2018) Image-to-image translation with conditional adversarial networks. https:\/\/arxiv.org\/abs\/1611.07004"},{"key":"553_CR43","unstructured":"Abadi M, Agarwal A, Barham P et al (2016) TensorFlow: Large-scale machine learning on heterogeneous distributed systems. https:\/\/arxiv.org\/abs\/1603.04467"},{"key":"553_CR44","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012","journal-title":"J Chiropr Med"},{"key":"553_CR45","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1097\/01.brs.0000160840.51621.6b","volume":"30","author":"NR Dang","year":"2005","unstructured":"Dang NR, Moreau MJ, Hill DL, Mahood JK, Raso J (2005) Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the spinal deformity study group\u2019s AIS radiographic measurement manual. Spine (Phila Pa 1976) 30:1064\u20131069. https:\/\/doi.org\/10.1097\/01.brs.0000160840.51621.6b","journal-title":"Spine"},{"key":"553_CR46","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1007\/s00586-008-0755-1","volume":"17","author":"JR Dimar 2nd","year":"2008","unstructured":"Dimar JR 2nd, Carreon LY, Labelle H et al (2008) Intra- and inter-observer reliability of determining radiographic sagittal parameters of the spine and pelvis using a manual and a computer-assisted methods. Eur Spine J 17:1373\u20131379. https:\/\/doi.org\/10.1007\/s00586-008-0755-1","journal-title":"Eur Spine J"},{"key":"553_CR47","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1097\/01.bsd.0000128345.32521.43","volume":"18","author":"E Berthonnaud","year":"2005","unstructured":"Berthonnaud E, Labelle H, Roussouly P, Grimard G, Vaz G, Dimnet J (2005) A variability study of computerized sagittal spinopelvic radiologic measurements of trunk balance. J Spinal Disord Tech 18:66\u201371. https:\/\/doi.org\/10.1097\/01.bsd.0000128345.32521.43","journal-title":"J Spinal Disord Tech"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00553-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00553-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00553-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T13:14:08Z","timestamp":1738156448000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-025-00553-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,29]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["553"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00553-6","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,29]]},"assertion":[{"value":"28 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study, based on anonymized data, received approval from the Local Ethics Committee of San Raffaele Hospital, Milan, Italy (protocol code: RETRORAD; registry number: 61\/int\/2017).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"FG and LMS are members of the Scientific Editorial Board (section: musculoskeletal) for\n                      European Radiology Experimental\n                      . As such, they did not participate in the selection nor review processes for this article. The remaining authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11"}}